The concentrations of volatile organic compounds (VOCs) and odor-inducing substances were measured using selected ion flow tube mass spectrometers (SIFT-MS) and a drone equipped with an air quality monitoring system. SIFT-MS can continuously measure the concentration of VOCs and odor-inducing substances in realtime without any pre-treating steps for the sample. The vehicle with SIFT-MS was used for real-time measurement of VOC concentration at the site boundaries of pollution sources. It is possible to directly analyze VOCs concentration generated at the outlets by capturing air from the pollution sources with a drone. VOCs concentrations of nine spots from Banwol National Industrial Complex were measured by a vehicle equipped with SIFT-MS and were compared with the background concentration measured inside the Metropolitan Air Quality Management Office. In three out of the nine spots, the concentration of toluene, xylene, hydrogen sulfide, and methyl ethyl ketone was shown to be much higher than the background concentration. The VOCs concentrations obtained using drones for high-concentration suspected areas showed similar tendencies as those measured using the vehicle with SIFTMS at the site boundary. We showed that if both the drone and real-time air quality monitoring equipment are used to measure VOCs concentration, it is possible to identify the pollutant sources at the industrial complex quickly and efficiently check sites with high concentrations of VOCs.
In this study, leachate treatment facility (outlet, facility inside) and landfill sections (vent systems, landfill surface)of nine landfills is being buried in korea were studied emission characteristics of odor compounds. Air dilutionvalue in ventpipes of landfill section was generally highest and was more 3 times higher than emission standard(air dilution value of facilities outlet : 500) in Daejeon, Tongyeong, and Busan landfill. Outlet of leachate treatmentfacilities in Tongyeong and Daegu landfill, in case, was higher respectively 20 times, 6 times than other landfills,commonly show that a large contribution to the odor of hydrogen sulfide. In case of ordor emission rate, ammoniaand hydrogen sulfide were surveyed to comprise a high rate for odor emission rate. Odor emissions based onlandfill scale, large landfill (Sudokwon) and small landfills (Yeosu, Chuncheon, Chungju) is low in odor emissionsper unit area, whereas medium landfill (Busan, Daejeon, Daegu) was estimated to be high odor emissions. In caseof large landfill, leachate treatment facilities is management in good condition and discharged odor emission oflandfill sections was low into ambient air. In case of small landfill, decay gases and leachate is few. Thereforeodor emissions is fewer than estimated medium landfill. In case of medium landfill, management condition ofleachate treatment facility was in poor and landfill sections was under not stabilization stage. Thus, mediumlandfills was identified that needs to be intensive care.
This study evaluated the concentration(OU/m3) of a complex odor being discharged from tire, feedstuff, bakery, paper, casting and painting manufacturing process, correlation between odor concentration(OU/m3) and the odor sensor was investigated. 4 type(A, B, C, D) gas sensors of metal oxide compounds are used in this study. Each odor sample of manufacturing process is diluted with odorless air and diluted odor samples were prepared for five different concentrations. Correlation results(R) of odor sample of tire, feedstuff, bakery, paper manufacturing process ware 0.86~0.99, and odor sample of casting, painting manufacturing process ware more than 0.93. Thus the odor concentration(OU/m3) evaluation by odor sensor was to determine the possible. In particular odor sensor B and D are likely to be effective for evaluation of odor concentration. However, odor samples before evaluation is needed the calibration process depending on the field odor sample to field apply.
The objectives of this investigation are as follows: 1) To sort out places of businesses that have to do with the discharge of offensive odor 2) To find out what generates offensive odor 3) To check the current status regarding offensive odor. The investigation is held through complete enumeration of approximately two thousand businesses concerning the SihwaㆍBanwol Industrial Complex. The local residents have directly visited related businesses and performed the following investigations: 1) General status check 2) Area source 3) Point source The investigation of offensive odor is utilized by direct olfactory method in six levels. Through this method, the followings have been established as DB: Degree of offensive odor, type of odor, preventive facility status, etc. The major characteristic of this investigation is that local residents have directly visited individual businesses and checked the status of offensive odor, which opens up a possibility of mutual settlement for the reduction of offensive odor between businesses and local residents. Businesses and local residents can share a common understanding and this means a great deal. Furthermore, it is widely expected that the investigation data can be utilized as a source for presuming the origin of offensive odor in case of civil petition.
In this study, we investigated the characteristics of Volatile Organic Compounds(VOCs) emission from painting and printing facilities in the Pyeongdong industrial complex in Gwangju. In addition, the objective was to understand the distribution characteristics of VOCs in the ambient air in industrial complexes affected by painting and printing facilities. The painting facility mainly emitted toluene, acetone, butyl acetate, 4-methyl-2-pentanone, ethyl acetate, 1-butanol, methyl ethyl ketone, m,p-xylene, o-xylene, 4-ethyltoluene, ethylbenzene, 3-ethyltoluene, and 1,2,4-trimethylbenzene. The main emission components in printing facilities were methyl ketone, ethyl acetate, acetone, 2-propanol, toluene, heptane, and butyl acetate. Ethyl acetate, toluene, 2-butanone, acetone, butyl acetate, 2-propanol, xylenes, and 4-methyl-2-pentanone were detected in the ambient air of the Pyeongdong industrial complex, consistent with the VOCs emitted by painting and printing facilities. The average concentration of seasonal TVOCs followed an order of winter > fall > spring > summer, whereas the concentrations of daytime and nighttime TVOCs were generally higher at night than those during the day, and the wind speed was greater during the day than it was at night. Based on a factor analysis of VOCs in the ambient air of Pyeongdong industrial complex, it is considered that organic solvents used in coating, printing, and electronics manufacturing facilities, as well as diesel vehicle emissions played a major role.
In order to clarify the contribution rate of PM concentration due to regional emission distribution, Brute force analysis were carried out using numerical estimated PM data from WRF-CMAQ. The emission from Kyeongki region including Seoul metropolitan is the largest contribution of PM concentration than that from other regions except for emission of trans-country and source itself. Contribution rate of self emission is also the largest at Kyeongki region and its rate reach on over 95 %. And the rate at Gangwon region also higher than any region due to synoptic wind pattern. Due to synoptic wind direction at high PM episode, pollutants at downwind area along from west to east and from north to south tends to mix intensively and its composition is also complicated. Although the uncertainty of initial concentration of PM, the contribution of regional PM concentration tend to depend on the meteorological condition including intensity of synoptic and mesoscale wind and PM emission pattern over upwind region.
It will be necessary to make proper management plans to preserve the air quality in good level for the public. In order to make these plans, source information and detail emission inventories of the city and near industrial areas should be given. However, lack of the source measurements data makes us more difficult to complete the source inventory. VOC source inventory could be utilized for the feasibility study to estimate the contribution of VOC sources presenting to the receptor such as residential area. It may give policy maker an idea how to control the air quality, and improve their social environment in the area. This study shows data that measured VOCs concentrations from the local industrial areas in Jeonju during from May 2005 to January 2006. The samples were collected from the near sources in 7 major factories in the industrial park as well as 5 general sources in near city Jeonju area to elucidate the abundances of speciated VOCs and their spacial and temporal distributions depending on source bases. Industrial sources are as follows; chemical, food, paper, wood, metal, non-metal (glass), and painting (coating) industries. The 5 general sources are sampled from tunnel, gasoline gas station, dry cleaning shop, printing (copy) shop, and road pavement working place in urban area. To understand the near source effect at receptor, samples from the 2 receptor sites (one is at center of the industrial complex and the other site is at distance residential area downwind from the center) were collected and analyzed for the comparison to source concentration. The mass contributions of the speciated VOC to total mass of VOCs measured from the different sources and ambient (2 receptors) were presented and discussed.
The purpose of this study was to develop the preliminary source fingerprints of volatile organic compounds (VOC). The source categories studied were vehicles, gasoline vapor, gasoline storage tank, coating, dry cleaning and road covering. The source samples were collected using 6L electro-polished stainless steel canisters for about 20 seconds. From this study, the main component emitted from VOC sources in Korea was toluene. The toluene proportion for road covering, vehicles, coating and gasoline vapor were 35, 18, 16 and 5%, respectively. The C2-C5 alkane and alkene compounds were mainly emitted from vehicles, gasoline vapor and gasoline storage tank. The main compounds of coating were m/p-xylene(34%), toluene(16%), 1,2,4-TMB(10%) and o-xylene(9%), which are aromatic hydrocarbons. In the case of dry cleaning, nonane(41%), 1,2,4-TMB (22%) and 1,3,5-TMB(13%) were mainly emitted.
A case of air pollution study of estimation of emission rate for source to railroad rolling stock and emissive character about is unusual. Recent emission rate of railroad rolling stock was estimated with emission factor of EPA in three region(Seoul, Incheon, and Gyeonggido). But this EPA factor could be incorrect because Korea and America have a different railroad environment in the variety of fuel and character of railroad rolling stock. In this study, emission rate of each line, car and region(district) with emission factor of Korean case(National Railroad Administration, 1997) was estimated. In Busan Metropolitan City, railroad rolling stocks were divided accoding to, each line, car and service. Particularly, the idle fuel rate omitted in the preceding study was included in calculation fuel rate. Total emission rate of Busan Metropolitan City was 887.41t/year. Each emission rates of Kyeongbu line, Donghaenambu line, Gaya line, Uam line, Bujeon line, and idle was 489.15t, 196.46t, 33.94t, 12.66t, 6.47t, and 148.72t, respectively.