검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 35

        1.
        2023.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Conventional aquaculture faces declining productivity, shifting to recirculating aquaculture system (RAS), known for minimizing water usage and maintaining consistent water temperatures for year-round fish growth. Rainbow trout (Oncorhynchus mykiss), a globally important cold-water species and the third most farmed fish in inland waters of Korea, valued for its fecundity and rapid growth. Dissolved oxygen, an important environmental factor affecting fish production and economics, highlights the need for smart aquaculture practices. Since 2018, the rise of intelligent aquaculture platforms, incorporating information and communications technology (ICT), emphasizes the essential role of RAS implementation. This eight-week study aimed to determine the optimal dissolved oxygen concentration for rainbow trout in RAS, utilizing a device for continuous monitoring, control and record. Dissolved oxygen concentrations were set at 5-6 mg/L, 9-10 mg/L, 14-15 mg/L and 17-18 mg/L. The growth rate significantly decreased at 5-6 mg/L, with no significant differences in other experimental groups. In hematological analysis, growth hormone (GH) was significantly highest at 5-6 mg/L, followed by 9-10 mg/L while Insulin-like growth factor-1 (IGF-1) was significantly lowest at 5-6 mg/L. In conclusion, the optimal dissolved oxygen concentration for rainbow trout in RAS is approximately 9-10 mg/L. Higher concentrations do not contribute to further growth or profitability.
        4,300원
        2.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 진해만의 DO 농도 재현을 목표로 LSTM 모형의 최적 매개변수 조건과 예측변수를 선별하기 위한 Case study를 진행하였다. 모형 매개변수 Case study 결과, 가장 적은 Hidden node와 Epoch인 Hidden node=10, Epoch=100에서 가장 낮은 정확도를 보였다. 이는 모형이 과소적합(Underfitting) 상태인 것으로 판단된다. Hidden node=80, Epoch=1200에서 R2 값은 0.99로 가장 높은 정확도를 보였다. 예 측변수 Case study 결과, 1개의 환경변수만을 예측변수로 사용한 Step 1에서 수온을 예측변수로 했을 때 저층 DO 농도 재현의 R2 값은 0.81 로 가장 높은 정확도를 보였다. 이후 2개의 환경변수를 사용한 Step 2에서는 수온과 SiO2를 예측변수로 했을 때 R2 값은 0.92로 수온만 사 용했을 때보다 정확도가 급격히 증가하였다. 이는 저층 DO 농도와 SiO2 농도간의 높은 상관성(=0.70)에 기인한 것으로 판단된다. 상기 결과로부터 진해만의 DO 농도 재현에 적합한 LSTM 모형의 매개변수와 예측변수를 찾을 수 있었다.
        4,000원
        3.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 인공지능기법을 이용하여 진동만의 용존산소량 예측을 하였다. 관측자료에 존재하는 결측 구간을 보간하기 위해 양방향재귀신경망(BRITS, Bidirectional Recurrent Imputation for Time Series) 딥러닝 알고리즘을 이용하였고, 대표적 시계열 예측 선형모델인 ARIMA(Auto-Regressive Integrated Moving Average)과 비선형모델 중 가장 많이 이용되고 있는 LSTM(Long Short-Term Memory) 모델을 이용 하여 진동만의 용존산소량을 예측하고 그 성능을 평가했다. 결측 구간 보정 실험은 표층에서 높은 정확도로 보정이 가능했으나, 저층에서는 그 정확도가 낮았으며, 중층에서는 실험조건에 따라 정확도가 불안정하게 나타났다. 실험조건에 따라 정확도가 불안정하게 나타났다. 결과로부터 LSTM 모델이 중층과 저층에서 ARIMA 모델보다 우세한 정확도를 보였으나, 표층에서는 ARIMA모델의 정확도가 약간 높은 것으로 나타났다.
        4,000원
        4.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to determine the location of average concentration and distribution status of dissolved oxygen in the rectangular aeration tank of the sewage treatment plant was analyzed and the difference of dissolved oxygen concentration was remarkable at each location. Compared with the computational fluid dynamics analysis, it was found that the results were consistent with the measurement results by showing the difference of dissolved oxygen concentration between the locations. Based on the measured data, the representative location of dissolved oxygen in aeration tank was selected by using statistical analysis method and the representative location was expressed in three-dimensional coordinates(LWH : 25%, 50%, 33%) from flow direction and left wall. Also the difference between the dissolved oxygen concentration at the actual measurement location and the average concentration value of the entire aeration tank was founded, and the equations for calibrating the automatic measurement data considering the actual measurement location were calculated.
        4,000원
        5.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        미더덕의 집단폐사가 주로 발생하는 여름철 고수온 및 빈산소에 의한 생물학적 지표를 찾아 대량폐사 원인 구명을 위한 기초자료로 활용하기 위하여 수온상승 및 용존산소농도 감소에 따른 미더덕의 생존율, 생리적 반 응 및 조직학적 변화 등을 조사하였다. 수온상승에 따른 생존율은 수온 23􀆆C에서 63.3%, 26􀆆C 에서 56.6%였으며, 수온 29􀆆C에서 노출 6일째 모두 사 망하여 노출 6일 동안의 반수치사 수온은(6day-LT50)은 24.58􀆆C (19.48~35.48􀆆C)였다. 용존산소 농도 감소에 따 른 생존율은 노출 11일째 용존산소농도 4.0 mg L-1에서 20%였으며, 2.0 mg L-1에서는 모두 사망하였고, 반수치사 용존산소 농도 (11day-LC50)는 3.88 mg L-1 (3.29~4.57 mg L-1)였다. 산소소비율과 암모니아질소 배설률은 임계 수온 및 임계용존산소 농도이하에서 감소하였다. 수온 상승 및 용존산소 농도 감소에 따른 미더덕의 새낭, 소화관 및 피낭의 병리조직학적 결과는 각 기관을 구성하고 있는 상피세포층의 증식, 응축 및 괴사, 식세포 및 혈구침윤, 섬모탈락, 근섬유 변성 등의 변성이 공통적 으로 관찰되었다. 미더덕은 수온 24􀆆C 이상, 용존산소 3.8 mg L-1 이하에서 조직학적 병변, 대사율 감소 등으로 환 경변화에 매우 민감한 생물이므로 여름철에 양성되고 있는 미더덕의 양식장관리에 세심한 관리가 요구된다.
        4,000원
        6.
        2013.12 구독 인증기관 무료, 개인회원 유료
        The distribution of dissolved oxygen (DO) and its variability in Chunsu Bay were studied. Monthly hydrographic survey and realtime monitoring for water quality conditions were carried out in study area. Vertical distribution of DO shows the formation of hypoxia in the bottom water in the vicinity of the artificial dyke and net cage aquaculture site in summer. Annual mean of DO was 8.4 mg/l, with minimum monthly mean of 6.9 mg/l in July and maximum of 11.2 mg/l in March. Temporal variation of DO at bottom water around the net cage aquaculture site shows pronounced oscillatory characteristics with range of 0.5~7.0 mg/l. Coherency analyses between the tidal range and DO concentration shows that variation of DO is significantly coherent with tidal range at semi-diurnal period with 1~3.5 hours phase-lags. A simple DO budget model was set up to account for the formation of the extreme hypoxic conditions in Chunsu Bay. The governing equation is based on the mass-balance for kinetic process with simplified parameter of source and sink terms of DO. the source term is represented by replenishment through the vertical and horizontal diffusion and mixing. the sink terms comprise function of sediment oxygen demand (SOD) and carbonaceous biochemical oxygen demand (CBOD). The result of numerical solution indicates the dominant role of SOD as the overriding factor against the oxygen supply.
        4,200원
        7.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 멍게 대량폐사의 주요 현상으로 나타나고 있는 물렁증 발생의 원인을 찾기 위하여 저산소의 영향에 의한 물렁증 발생, 생존률, 대사율 및 병리조직학적 변화를 분석하였다. 용존산소의 감소에 따른 멍게의 생존률은 용존산소 농도 2 mg L-1에서 노출 4일째 모두 폐사하였으며, 3 mg L-1에서는 노출 5일째 50%를 나타내어 5days-LC50은 3.55 mg L-1 (1.86~4.96 mg L-1)로 나타났다. 그러나 저산소에 노출된 기간 동안 물렁증 발생은 관찰되지 않았다. 산소소비율은 대조구와 비교하여 용존산소 농도 5 mg L-1 이하에서 유의하게 감소하여 저산소에 노출되면 일정기간 호흡률을 조절하는 것으로 추정된다. 저산소에 의한 멍게의 새낭, 소화선 및 피낭의 병리조직학적인 변화는 각 기관을 구성하고 있는 상피세포층의 괴사, 혈구세포의 침윤, 세포핵 응축 및 변형 등이 관찰되었다. 형태적인 변화는 피낭이 쪼글어들어 부피가 작아지고 내부 기관은 탈색되고 아가미와 간췌장의 괴사가 관찰되었다.
        4,000원
        9.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        빈산소 수괴는 산소 부족뿐만 아니라, 용존산소의 결핍에 따른 혐기 상태에서 생성된 황화수소와 암모니아 등 유독가스가 어 패류를 직접 폐사시키거나, 저서생물 군집의 출현종과 개체 수에도 심각한 영향을 마친다. 본 연구에서는 빈산소 수괴가 발생한 해역의 저층 해수를 펌핑하여, 액체산소를 용해시켜 용존산소 농도를 20 mg/L 이상으로 상승시킨 해수를 다시 저층으로 주입하는 장치를 개발하여 그 효능을 검토하였다. 이 장치를 이용하여 해수를 3.6 m2/min 용량으로 저층에 주입하면서 액체산소를 분당 4.8~26.3 L 범위로 공급할 때, 단시간에 해수 중 용존산소 농도는 7~25 mg/L로 상승하였다. 이때 공급한 액체산소는 해수 중에 90% 이상 용해되는 것으로 나타났다 본 장치는 산소를 용해시키기 위한 별도의 탱크가 필요 없고, 해수를 수면위로 퍼 올리는 높이가 낮아도 되므로 적은 동력을 이용하여 높은 효율로 고농도의 산소를 저층에 공급할 수 있는 것으로 나타났다. 그러므로 본 장치는 연안 및 호소의 저층 빈산소 수괴 발생을 저감시킬 수 있어 빈산소 수괴 발생으로 인한 양식피해를 저감시킬 수 있을 것으로 기대된다.
        4,000원
        11.
        2009.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        주요 엽채류 7종의 주년 안정생산을 위한 담액수경 재배 시 양액의 순환주기가 양액의 용존산소 농도, 엽채류의 생육, 그리고 식물영양소의 함량에 미치는 효과를 검토한 결과, 양액을 1일 10분 순환 처리구는 정식 13일 후 용존산소 농도가 급격하게 떨어지고 17일 후에는 2.8mg L-1, 20일 후에는 최저 1.5mg L-1까지 낮아졌다. 처리 20일 후 7가지 엽채류의 생체중은 1일 10분 처리구에서는 대조구인 10분 순환/110분 정지 처리구에 비해 0~24% 범위에서 낮아졌으며, 10분 순환/10분 정지 처리구에서는 -2~34% 증가하였다. 양액의 순환주기가 짧을수록 식물체 엽내 P의 함량이 증가하였으며, 식물체의 C/N율과 비타민 C 함량은 감소하였다. 이상의 결과, 담액수경 엽채류의 안정적인 생육과 식물영영소의 흡수를 위해서 2시간에 10분 정도의 양액 순환 처리가 효율적이었다.
        4,000원
        13.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        비다공성 중공사막 접촉기를 이용하여 수용액 내 용존 산소의 농도를 조절하고자 하였으며, 용존 산소의 농도를 전산모사를 통하여 예측하였다. 공급 기체와 공급 수용액이 같은 방향으로 흐르는 병류 흐름 시스템에 대한 분리막 접촉기 공정 지배 미분 방정식을 5차 Runge-Kutta-Verner 법으로 해석하였다. Compaq Visual Fortran 6.6 소프트웨어로 용존 산소농도 예측 프로그램을 개발하였다. 개발된 프로그램을 사용하여 수치해석을 수행한 결과, 분리막 수가 16,000개로 일정하며 공급기체의 유속이 0.536 mol/sec이고 압력이 486 kPa이며 공급 수용액의 유속이 16.69 mol/sec이고 산소의 몰분율이 0.995으로 유지된 상태에서, 분리막의 길이가 0.4에서 1.2m로 증가함에 따라 용존 산소는 30에서 64 ppm으로 증가하였음을 알 수 있었다. 분리막의 길이가 0.4 m일 때 공급수용액의 유속이 9.26에서 26.85 mol/sec로 증가함에 따라 용존 산소가 40에서 20 ppm으로 감소함을 알 수 있었다. 또한 공급 기체 압력이 298에서 847 kPa으로 증가함에 따라 용존 산소는 33에서 69 ppm으로 증가함을 알 수 있었다.
        4,000원
        16.
        2001.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        1997년 2월부터 1998년 7월까지 총 33회에 걸쳐 시화호내 11개 정점에서 배수갑문 개·폐에 따른 용존산소와 pH의 변화를 파악하였다. 해수유입이 없었던 1997년 3월부터 1997년 5월까지의 용존산소 분포는 대부분의 수층에서 10mg/l이상을 보이고 l1m 이하의 수심에서 5mg/l 이하를 나타냈다. 1997년 6월에 수심 6m 이하에서 무산소층이 나타났다. 강우기동안 배수만 실시했을 경우, 무산소층이 수심 8m에서 6m 이하로 증가하였다. 또한 해수유입 직후의 시화호 내에 잔존하는 무산소층이 해수에 포함된 용존산소를 급격히 소모시키는 특징을 나타냈다. 이러한 현상은 pH7.8∼8.2의 해수와 pH7.4이하의 저층수가 만나게 되어 산화작용을 촉진시켰기 때문인 것으로 해석된다. 해수유입이 크게 증가된 1998년 1월에는 전 수층의 용존산소가 10mg/l 이상을 나타냈다. 결론적으로 시화호 배수갑문 운용에 따른 수질개선을 위해서는 여름철에는 염분약층이 생성되지 않도록 해수의 유출량과 유입량을 늘리는 것이 효과적일 것으로 판단된다.
        4,500원
        17.
        2001.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        4,000원
        18.
        2000.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        4,000원
        20.
        1997.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The in situ observations and the seawater analyses were conducted in July and August, 1996 for the purpose of describing the characteristics of organic pollution, dissolved oxygen distributions, and the evaluation of water quality in Mokpo harbour. The vertical density distribution of water column was found to be in stable structure with higher water temperature and lower salinity on surface layer at ebb tide in summer. In July, dissolved oxygen was shown to be oversaturated on surface and bottom layers, while in August, which was shown to be oversaturated on surface layer, and to be unsaturated on bottom layer as 68∼93% of saturation percentage. Dissolved oxygen of bottom layer in August was evaluated to be under the regular grades, based on Korean standards of seawater quality. In view of COD, the seawater quality of Mokpo harbour in summer was evaluated to be deteriorated due to organic wastes and graded to be the third class, and TSS of Mokpo harbour in summer was graded to be the second class, based on Korean standards of seawater quality. In particular, COD of surface layer in August was found to be under the regular grades. It is, therefore, necessary to take measures for the control of pollution loads and the proper management of seawater quality in Mokpo harbour. The distribution patterns of DO, COD, VSS and Chlorophyll-a on surface layer along the downstream center line from inner harbour to harbour entrance were similar to one another at ebb tide in August.
        4,200원
        1 2