검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 40

        1.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Numerous studies have attempted to predict the energy output of solar-powered vehicles based on different parameters such as road conditions, driver characteristics, and weather. However, since these studies were conducted on stationary vehicles, they are limited in their accuracy when applied to driving vehicles. This study aimed to improve the accuracy of electric power prediction for a solar-powered bus by applying a technique that improves energy efficiency without affecting driving performance. A comparative analysis of power generation and solar irradiance data was conducted for the bus driven on different roads to forecast its power generation, and a high-accuracy power generation prediction equation was derived. A comparison with actual test results revealed that a power generation forecast accuracy of at least 90% was achieved, validating the equation used for forecasting. With this power generation prediction process, it is possible to forecast the amount of energy generated in advance when a solar bus is operated in a specific area.
        4,000원
        2.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 연동온실의 골조로 인한 내부 광 분포를 검토 하기 위하여 위치별(중앙부 및 측면부) 일사량을 실측하고, 오 전(08:30-12:30)과 오후(12:35-16:30)로 시간대를 구분 하여 일사량, 광 투과율 및 일 적산일사량을 분석하였다. 또한 토마토의 생육 및 수확량을 위치별로 비교하였다. 오전일 때 중앙부와 측면부의 일사량은 각각 275.2W·m-2, 314.9W·m-2 이고, 오후일 때는 각각 278.1W·m-2, 313.9W·m-2로 측면부 보다 중앙부가 오전은 12.6%, 오후는 11.4% 낮았고, 광 투과 율과 일 적산일사량도 중앙부가 낮게 나타났다. 생육 특성에 있어서는 첫 번째 조사의 엽장과 엽폭을 제외하고는 조사 종 료일까지 유의미한 차이가 없었다. 토마토의 최종 주당 평균 수확량은 재배 위치에 따라 중앙부 4,828g, 측면부 4,851g으 로 유의미한 차이는 없었고, 중앙부가 0.5% 적게 나타났다. 토 마토의 광보상점은 60W·m-2이고 광포화점은 281W·m-2로 중앙부의 시간대별 일사량은 광보상점보다는 높고, 광포화점 보다는 낮으나 그 차이가 크지 않아 온실 내 위치에 따른 생육 및 수확량의 차이가 미미한 것으로 판단하였다. 향후 이 검토 결과를 포함하여 온실을 설계할 때 광 환경을 고려한 설계를위해 온실의 설치 방향, 위치 및 지붕 경사도 등에 따른 온실 내 광 분포 분석이 필요하다.
        4,000원
        3.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        딸기 수경재배 시 일사비례제어를 이용하여 생육단계별 적 정 누적일사량 기준을 설정하고자 수행하였다. 급액 방법은 외부 일사량을 기준으로 일정 누적 일사량에 도달하면 급액 하였고 누적 일사량 기준은 150, 200J·cm-2과 생육단계에 따 라 200J·cm-2에서 150J·cm-2로 변경하는 처리를 두었다. 타이 머 제어는 대조구로 설정하였다. 월별 평균 급액 횟수는 누적 일사량이 많은 3월에 150 J·cm-2과 생육단계별(150J·cm-2) 처 리구가 5.6회, 누적일사량이 적은 12월에 200J·cm-2과 생육 단계별(200J·cm-2) 처리구가 2.7회, 타이머는 3.6-3.8회였 다. 수분이용효율은 주당 총 급액량이 적었던 타이머 처리구 가 19.8g·L-1로 일사제어 처리구에 비해 낮았다. 일사제어에 따른 생육 및 과실 특성은 차이가 없었다. 생육단계별 처리구 가 총 상품과 수량은 주당 328g, 상품과율 85.3%로 가장 높았 다. 딸기 수경재배 시 일사비례 급액제어 방식은 재배기간 동 안 동일한 누적일사량 기준보다 생육단계별로 누적일사량을 조절하는 것이 과실의 수량 향상에 도움이 되었다.
        4,000원
        4.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        우리나라 딸기 재배는 시설 재배로 이루어지고 있으며, 대부분 농가의 급액 관리는 재배자의 경험을 토대로 타이머 제어 방식으로 이루어지고 있다. 타이머 급액 방법은 재배 환경, 작물의 생육 단계, 배지 수분 함량 등을 고려하기 어려워 작물을 최적 수준으로 관리하지 못하고, 급액 관리의 정확성이 결여되는 문제점이 있다. 적산 일사량과 배지 수분함량을 이용한 급액 방법은 작물의 생육 상태에 따라 정밀하게 양액을 공급하는 친환경적인 방법이다. 본 연구는 코이어배지를 이용 한 딸기 수경재배에서 적산일사량과 배지 수분함량을 이용한 복합 급액 제어와 타이머 제어 급액 방법을 비교하고 복합 급액 제어 시 최적의 적산 일사량 기준을 설정하고자 수행하였다. 적산일사량 급액 방법은 외부 일사량을 기준으로 100, 150, 250J∙cm -2에 도달하면 자동으로 급액하며 배지 수분함 량이 60% 미만이면 강제 급액하고, 1회 급액량은 50mL로 공급하였다. 타이머 제어는 대조구로 설정하였다. 급액을 개시 하는 적산 일사량 기준이 작을수록 일일급액량이 많았으며 100J∙cm -2 기준 급액 시 급액량은 250J∙cm -2 처리구 대비 46% 많았다. 지상부 생체중과 건물중 모두 복합 급액 제어 방법이 타이머 제어보다 높았으며, 100, 150J∙cm -2 처리구에서 지상부 생체중이 높았고 100J∙cm -2 처리구에서 건물중이 유의하게 높은 값을 나타냈다. 수량 또한 타이머 제어 방법보다 복합 제어 방법에서 유의하게 높았으며 적산 일사량 기준이 작을수록 초기 수량이 증가하였다. 평균 과중은 타이머 제어 급액 시 가장 낮았다. 본 연구 결과 딸기의 정밀 급액 관리를 위하여 적산 일사량과 배지 수분 함량 센서를 이용한 복합 제어 활용 가능성을 확인하였다.
        4,000원
        5.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기상청 일사관측소 관측환경 분석을 위하여 수치표고모델(DEM)과 태양복사모델을 이용하여 주변지형에 의한 차폐와 하늘시계요소(SVF) 및 일사량을 산출하였다. 지형고도자료(10 m 해상도)를 통해 관측소를 중심으로 주변 25 km내의 지형들을 이용하여 스카이라인과 SVF를 계산하였다. 또한, 일사관측소별 산출된 천기도와 스카이라인을 중첩하여 지형에 의한 차폐를 분석하였다. 특히 인천 관측소는 주변지형의 차폐가 적었고 청송군과 추풍령 관측소는 주변 지형에 의한 차폐가 큰 관측소로 나타났다. 태양복사모델을 이용하여 동일 조건에서 지형 특성에 따른 일사량을 산출하여 지형에 의한 기여도를 분석하였다. 연누적 일사량 계산결과, 청송군 관측소의 경우 수평면 일사량과 비교하였을 때 직달일사량은 12.0% 이상 차폐되었고 산란일사량은 5.6% 그리고 전천일사량은 4.7% 감소하였다. 평균 일누적 일사량을 기준으로 편차를 분석하였을 때 0.3% 이상 전천일사량이 감소되는 지점은 6개 관측소였다. 42개 관측소 중 8소는 관측소의 이전 또는 관측장비의 이동설치가 시급한 것으로 분석되었고 1/2 이상(24소)의 관측소는 일사관측환경에 대한 검토가 필요한 것으로 분석되었다. DEM자료는 관측소 주변의 인공구조물과 식생 등이 포함되지 않기 때문에 더 상세한 관측환경분석이 요구된다.
        4,900원
        6.
        2017.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구에서는 지표 관측 자료와 위성 자료 그리고 GWNU 단층 복사 모델을 이용하여 맑은 상태의 전천 일사 량을 계산하였으며, 전운량에 따라 관측 및 모델의 일사량 값을 비교 분석하였다. 연구 자료는 2012년 강릉원주대학교 복사 관측소의 전천 일사량, 기온, 기압, 습도, 에어로졸 등의 관측 자료와 OMI 센서의 오존전량 자료 그리고 구름의 유무 및 전운량을 판단하기 위하여 자동 전운량 장비인 Skyview 자료를 이용하였다. 전운량이 0 할인 맑은 날의 경우 관측 값과 모델 값이 0.98로 높은 상관계수를 나타내었으나 RMSE가 36.62Wm−2로 비교적 높게 나타났다. 이는 Skyview 장비가 얇은 구름이나 박무 및 연무 등의 기상상태를 판단하지 못하였기 때문이다. 흐린 날의 경우 구름의 영 향을 보정하기 위해 전운량과 두 값의 차에 대한 비율을 이용한 회귀식을 복사 모델에 적용하였으며, 장비의 오탐지를 제외한 경우 상관계수가 0.92로 높은 상관성을 보였으나 RMSE가 99.50 Wm−2으로 높은 값을 보였다. 더 정확한 분석 을 위해서는 직달 성분의 차폐 유무 및 구름 광학 두께를 포함한 다양한 구름 요소의 추가적인 분석이 요구된다. 이 연구결과는 분 또는 시간에 따른 일사량을 산출하여 일사량이 관측되지 않는 지역에서 유용하게 사용될 수 있다.
        4,300원
        7.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Comparing some special words and phrases usage from Qing Hua Bamboo Inscriptions Vol. 1 to 5, we discover that special forms of words are suspected. Their writings don’t not belong to the normal characters at the Warring States period, on the contrary, they can only be found on the Shang Dynasty Oracle, Chou bronze in ancient china, and Li-Shu (隸書), Kai-Shu (楷書) after Han dynasty separately. We doubt that writings of Qing Hua Bamboo were fake by nowadays people.
        7,800원
        8.
        2016.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Shelter that communication equipment and on-equipment material are mounted on is transported by airplane, vehicle and has a function such as waterproof and shielding EMI. Maintaining proper inside temperature of shelter is important in order to operate equipment. Accordingly proper cooling capacity of cooling equipment which installed on the shelter is important for equipment and operator. To calculate proper cooling capacity, There are some considerations such as environmental factors and equipment in the shelter. In Korea solar irradiation and outdoor temperature is difference in accordance with geological characteristic. Also electric equipment mounted on the shelter is increased by development of technology. But the capacity of air conditioner is not changed thus there is a problem about operating equipment. In this paper, Compare cooling capacity of shelter when using air conditioner that is not enough cooling capacity and calculate proper cooling capacity to consider geological solar irradiation and outdoor temperature.
        4,000원
        9.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        비순환식 고형배지경에서 배액이 토양과 지하수 오염을 발생시키는 문제를 해결하고자 그동안 연구된 데이터를 바탕으로 배액 최소화 재배방식을 확립을 위해 본 연구는 토마토 코이어 수경재배농가 시설에서 FDR 센서, 적산일사량 센서 및 타이머를 이용하여 토마토를 재배하며 급배액량, 생육 및 생산량을 비교하였다. 정식 후 88일까지 일일 식물체당 평균 급액량은 처리구에 따른 큰 차이가 없었다. 하지만 정식 후 88일 이후 107일 까지 TIMER, FDR, IR 제어구 각각의 일일 식물체당 평균 급액량은 IR(2125mL) > TIMER(2063mL) > FDR(1983mL) 수준이었고 108일부터 120일 까지는 IR(2000mL) > TIMER(1664mL) > FDR(1500mL) 수준 이었다. 배액률은 TIMER 제어구의 경우 5~12%, FDR 센서 제어구의 경우 0~7%, IR 제어구의 경우 12~19% 수준으로 IR > TIMER > FDR 순이었다. 정식 후 88일 이후부터는 FDR과 IR 제어구가 급액량에 상이한 결과를 보였는데, 이는 재배 후기 즉, 5월 20일 이후 (정식 후 94일) 누적일사량의 증가로, IR 제어구에서는 급액이 증가된 반면 FDR 센서 처리구는 적심 이후 30일이 경과된 6월 2일경부터 IR 제어구 보다 일일 급액량이 평균 500mL 적게 공급된 결과이다. 식물체 생육 및 상품과 수량도 급액방식에 따른 통계적 유의차는 없었지만, 당도는 FDR 처리구에서 TIMER 처리구에 비해 약 11%, IR 처리구에 비해 약 18% 높았다.
        4,000원
        10.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Solar power is being spotlighted recently as a new energy source due to environmental problems and applications of solar power to curved structures are increasing. Solar panels installed on curved surfaces have different efficiencies depending on its position and the efficient positioning of solar panels plays a critical role in the design of solar power generation systems. In this study, the changing characteristics of solar irradiance were analyzed for hemispherical dome with a large curvature and the positioning of solar panels that can efficiently utilize solar energy was investigated. With an icosahedron-based hemispherical dome consisting of triangular elements as target model, a program for calculating solar irradiance using a normal vector of the solar module on each face was developed. Furthermore, the change of solar irradiance according to the sun’s path was analyzed by time and season, and its effects on shades were also examined. From the analysis results, the effective positioning could be determined on the basis of the efficiency of the solar panels installed on the dome surfaces on solar irradiance.
        4,300원
        11.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 일조시간과 강수량 자료를 이용하여 다중회귀 방법을 통해 일사량을 추정하였다. 연구에 사용된 자료 들은 강릉지역에 위치한 강원지방기상청(105 관측소, 1980-2007)과 신강원지방기상청(104 관측소, 2009-2014) 그리고 강릉원주대학교(GWNU 관측소, 2013-2014)이며, 105 관측소 자료를 통해 산출된 회귀식을 104 관측소와 GWNU 관측 소에 적용하여 비교분석하였다. 먼저, 일조시간만을 이용하였을 때 104 관측소는 기존 연구들과 유사한 상관계수(0.96) 와 표준오차(1.16 MJ m−2 )가 나타났고, GWNU 관측소에서는 높은 상관계수(0.99)와 낮은 표준오차(0.57 MJ m−2 )로 분석 되었다. 그리고 일조시간과 강수량 자료를 104 관측소에 적용하였을 때 상관계수 0.96과 표준오차 0.99 MJ m−2로 일조 시간만을 적용했을 때보다 표준오차가 감소되었다. 일조시간만을 이용한 방법보다 강수량이 추가된 방법은 관측 일사량 과 편차의 극값이 −26.6%(2010년 3월)에서 −31.0%(2011년 2월)로 증가되었다. 이는 강수량이 5월과 7-9월에 집중되어 나타나 이외의 월에서 추정식의 계수가 음으로 계산되었기 때문으로 분석된다. 따라서 한반도와 같이 강수량이 여름철 에 집중되는 지역에서는 월평균 강수량을 일사량 추정에 이용할 때 주의를 기울여야 할 것이다.
        4,200원
        12.
        2013.06 KCI 등재 구독 인증기관·개인회원 무료
        경범죄처벌법은 형사실체법의 일종으로서 범죄와 그에 대한 형벌을 규정하고 있다. 즉 경범죄처벌법은 경범죄로 취급되는 일련의 행위를 규정하고, 그에 대한 형벌로서 본래 ‘10만원 이하의 벌금, 구류 또는 과료’ 등의 형벌을 부과할 수 있도록 규정하고 있다(경범죄처벌법 제3조). 경범죄처벌법이 경범죄행위에 대해 통고처분에 의한 범칙금 납부로 사안을 종결할 수 있도록 규정한 것은 행위의 불법성과 책임이 상대적으로 가볍다는 점과 국민편의를 도모하는 차원이 반영된 것으로 보인다. 그렇다면 ‘통고처분에 대한 범칙금’ 납부는 -비록 명칭과 부과절차 등이 통상적인 공판절차가 아니라고 하더라도- 해당 처분의 근원은 형벌에 대한 규정이며, 통고처분의 대상이 된 행위 역시 경미‘범죄’이다. 시민의 소박한 관점에서 본다면 통고처분에 의해 범칙금을 납부한 자는 자신의 범칙행위에 대한 문제가 마무리된 것으로 신뢰하였을 것이다. 법치국가원리는 신뢰보호를 한 내용으로 하고, 일사부재리는 신뢰보호의 일종이다. 경범죄처벌법도 헌법상 일사부재리의 원칙을 동법 제8조 제3항 등에서 명시하여 재차 확인하고 있다. 경범죄처벌법은 통고처분에 의한 범칙금으로 규율해서는 안 되는 경우의 하나로 ‘피해자가 있는 행위’를 한 경우를 명시하고 있다. 그런데 피해자가 있음에도 불구하고 수사기관의 초동수사 미진 등으로 통고처분에 의해 사건을 마무리한 경우의 처리가 실제로 대법원판례에서 보는 것처럼 문제되고 있다. 생각건대 초동수사를 담당하는 경찰관은 개별 사건의 사실관계를 애초에 면밀하게 조사하였어야 하고 경범죄처벌법 등 관련 법률을 적용함에 있어서 신중하게 접근하여야 한다. 수사를 담당하는 국가기관이 애초에 법률을 정확히 해석하여 적용하지 못한 경우에 그에 대한 책임을 시민에서 전가하는 것은 국가기관의 책무와 위상에 어울리지 않는 것이라고 여겨진다. 그렇다면 통고처분에 의해 범칙금을 납부한 자에 대해서는 면소판결을 내리는 것이 일사부재리의 원칙과 법치국가원리에 부합하는 결론이 아닐까 한다.
        14.
        2012.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        몽골의 태양-기상자원지도는 위성자료 및 재분석 자료를 이용하여 개발되었다. 태양복사량은 단층 태양복사모델을 이용하였으며 입력자료는 SRTM, MODIS, OMI, MTSAT-1R 등의 위성관측자료와 전구모델의 재분석자료를 이용하였다. 계산된 결과는 NCEP/NCAR 재분석 DSWRF 자료를 이용하여 계산된 일사량을 검증하였다. 몽골은 서부의 산악지역과 중남부의 사막 및 반사막지대로 이루어져 있으며 대륙 내부에 위치하여 강수량이 적고 맑은 날이 많아 동일 위도상의 다른 지역과 비교하여 높은 일사량이 나타난다. 서부 산악지역은 고도가 높아 태양에너지가 많이 도달되는 곳임에도 불구하고 일사량이 낮게 나타난다. 그 이유는 산악지역에 존재하는 연중 적설이 위성자료의 구름탐지 알고리즘에서 구름으로 오탐지 되기 때문이다. 따라서 청천지수뿐만 아니라 일사량 또한 낮게 계산된다. 남부지역은 상대적으로 높은 가강수량과 에어로솔 광학두께가 나타났으나 다른 지역에 비해 위도가 낮고 청천지수가 높아 일사량이 높게 나타나는 것으로 분석된다. 계산된 월 누적 일사량은 547.59 MJ로써 전 지점에서 약 2.89 MJ로 높게 계산되었으며 상관성은 0.99였고 평방근오차(Root Mean Square Error; RMSE)는 6.17 MJ 이었다. 월별 통계 값을 계산하였을 때 상관성이 가장 높은 월은 10월로 0.94였고 3월은 0.62로 가장 낮게 나타났다.
        4,000원
        15.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        순환식 수경재배에서 배액의 EC, 부피, 관수량은 재사용 양액의 혼합비율을 결정하는 중요한 요소 중 하나이다. 적산 일사량 제어법으로 관수할 경우 일일 관수량의 예측은 곤란하며 일반적으로 고정된 혼합비율을 사용한다. 이 경우 새 양액이 고정적으로 투입되어 양분의 조정 효과가 기대되지만, 때때로 배액의 강제배출을 필요로 한다. 본 연구는 적산 일사량 제어법으로 관수하는 순환식 수경재배 조건에서 배액의 혼합비를 고정한 처리구(FR)와 정해진 혼합 용량 내에서 배액의 부피와 EC에 따라 혼합비를 변경하는 처리구(MR)의 재사용 양액 내 양분 조정효과를 비교하여 양수분 이용효율이 높은 혼합방식의 규명에 기여하고자 수행하였다. 배액의 농도 변화를 비교하기 위한 대조구로는 비순환식 수경재배 처리구(OP)를 구성하였다. FR처리구의 배액 혼합 비율은 배액의 희석 EC를 각각1.0, 2.0dS·m-1로 설정하여 혼합처리를 적용하였다. MR 처리구의 경우는 혼합 용량을 1회 관수량을 기준으로 배액의 EC와 부피에 따라 혼합비율이 변경되도록 하였다. 배액의 누적 현상은 FR 1.0 처리구에서 관찰되었으며, FR 2.0과 MR 처리구에서는 배액 누적현상이 나타나지는 않았으나 MR 처리구의 배액 저장량이 FR 2.0 처리구에 비해서 낮게 나타났다. 배액과 재사용 양액 내 Mg2+:K+:Ca2+와 SO2-4:NO-3:PO3-4의 당량 농도 간 비율 변화는 FR, MR 처리구에서 초기비율 대비 비교적 좁은 변화 범위를 나타냈다.
        4,000원
        16.
        2011.09 구독 인증기관 무료, 개인회원 유료
        This study fouces on the electricity generation of B1PV system in the super-tall buildings. To improve the efficiency of the B1PV system, solar irradiance and air temperature should be taken into consideration. This study does research on, one of two main parameters, the solar irracliance in the super high-rise buildings. According to the measurement of solar irracliance, it increased with altitude. It is, particularly, more obviously in the super-tall buildings than others. Subsequently, to make an accurate B1PV elecrticity generation prediction,it is necessary to anaiyze the solar irracliance distribution on the super-taII building's facade which is a prerequisite for optimal B1PV system design.
        4,000원
        17.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 남한지역의 시 공간 태양복사 분포를 분석하는 것이다. 2000년 1월부터 2007년 8월 까지 1분 간격으로 저장된 기상청 관할 22개 관측소의 전천일사 관측자료를 이용하였다. 수집한 일사량 관측자료는 시간에 대하여 변화하는 일사계 감도정수에 대한 불확실성을 제거하기 위하여 비교관측 결과와 태양복사 모델을 이용하여 보정을 하였다. 보정을 수행하기 위하여 강릉대학교 전천일사계를 22개 관측소의 일사계와 2007년 8월 동안 비교 관측을 하였다. 과거자료는 맑은 날에 대하여 태양복사 모형을 이용하여 시간에 대해 감소하는 일사계의 감도정수를 토대로 보정하였다. 모든 지점 및 모든 기간에 대한 평균은 13.31 MJ/day이며 보정을 통하여 13.75 MJ/day가 되어 0.44 MJ/day의 차이가 나타났다. 보정된 자료로 계절평균 및 연평균 태양복사 분포를 계산하였으며 전운량, 오존전량, 에어로솔 광학 두께, 지표면 알베도, 가강수량과 관계성을 분석하였다. 가장 큰 영향을 미치는 전운량 자료를 보정된 자료와 비교한 결과 과거(원시)자료보다 일관성이 더 높게 나타났다.
        5,200원
        18.
        2010.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        토마토를 대상으로 암면과 코이어를 사용한 자루재배에서 일사량제어와 배액전극제어법의 급액제어 능력을 실험한 결과, 배지 종류에 관계없이 일사량제어법에 비해 배액전극제어법에서 배지함수량과 배액량이 안정 적이었다. 총수확량과 상품과량은 배액전극제어법에서 많았으며, 동일한 급액제어 처리 안에서는 배지간 차이는 없었다. 당도는 급액제어 방법의 차이보다는 배지의 종류에 영향을 많이 받았다. 배액전극제어법은 펄라이트뿐만 아니라 암면과 코이어배지에서도 범용적으로 일사량제어법에 비해 유리한 것으로 나타났다.
        4,000원
        19.
        2008.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 시험은 펄라이트 배지에서 적산일사량에 따른 급액이 장미 'Cardinal'의 생육에 미치는 영향을 고찰하기 위하여 수행하였다. 배지내의 pH는 6.0에서 6.1사이로 안정적이었고 EC는 급액보다는 배액에서 높게 나타났는데 후기로 갈수록 높아지는 경향이었다. 무기 성분은 비순환식 C. Sonneveld처방 기준으로 보면 인산과 칼리, 마그네슘이 집적됨을 알 수 있었는데, 특히 칼리와 마그네슘은 각각 기준량 195ppm, 18보다 집적됨을 알 수 있었다. 배지의 배액율은 전체적으로는 일사량이 많으면 높아지는 경향이었다. 장미 수액은 오전 9시 경부터 12시까지 흐름이 있었는데, 10시 30분에서 11시 사이에 273g·hr-1이었는데 일사량에 비례하여 수액흐름이 증가하지는 않았다. 양액소모량은 250W·hr-1에서는 50m1구에서 212.8ml로 많았는데 수량도 154.6본/10a로 많아 양액소모량이 수량에 영향을 미치는 것을 알 수 있었다. 펄라이트 배지에서 양액공급량은 11월부터 3월에 200W·hr-1에서 50ml를 1일 6~10회 급액하고 일사량이 많을 때는 250W·hr-1에서 30ml를 1일 22~30회 급액하는 것이 좋을 것으로 생각된다.
        4,000원
        20.
        2005.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        계절별로 EC를 달리하여 처리한 결과, EC농도는 급액보다 배액이 높았고 EC를 높게 급액하면 급배액간의 농도차가 많았으며 pH는 급액 EC가 높을수록 배액의 pH가 낮았다. 장미품질은 절화장, 경경, 엽수, 화고, 화폭과 같은 장미의 품질에는 차이가 없었다. 수량은 4월과 5월에 EC 1.3으로 공급한 처리에서 6% 정도 많았고, 6, 7, 8월에는 EC 1.0으로 공급한 처리에서 10%정도 많았다. 또한 9월과 10월에는 EC 1.0과 1.3으로 공급한 처리에서 수량이 10%정도 많았다. 전체적으로는 EC를 봄에는 1.3,여름에는 1.0, 가을에 1.3, 그리고 겨울에 1.64로 조절한 (B)처리가 수량이 가장 많았다.
        4,000원
        1 2