검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 12

        1.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a two-stage electrostatic precipitator (ESP) was developed using a novel automatic dry cleaning device to reduce the ultrafine particles in subway stations. Collection efficiency was evaluated with a pilot scale ESP (1.2m× 1.2m) and the scale of the test duct was half of the subway air handling unit. The maximum collection efficiency for 0.3 μm particles was 96.9%. In addition, we studied a method of automatic dry cleaning for maintenance of the ESP. The cleaning efficiency was analyzed according to the cleaning flow rate for each particle loading amount to achieve a recovery rate over 90%. In addition, we derived the equation to estimate the reduction in collection efficiency according to the particle loading amount. It was confirmed that the performance of the contaminated ESP was restored to the initial state by the automatic dry cleaning in this study and that the electrical energy consumption was 5 times lower compared to utilizing conventional water cleaning.
        4,200원
        2.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 강화되는 황산화물 및 입자상물질의 배출규제를 만족시키기 위한 후처리장치로 습식전기집진기에 대한 실험적 연구를 수행하였다. 실험을 위해 선박용 중유(HFO, 황함유량 약 2.1%)를 연료로 사용하는 선박용 4행정 디젤엔진(STX-MAN B&W)을 활용 하였으며, 연돌에 설치된 습식전기집진기 입/출구에서 측정을 실시하였다. 미세먼지 측정을 위해서는 광학식 계측기(OPA-102) 및 중량농 도측정방식(Method 5 Isokinetic Train)을 이용하였으며, 황산화물 계측을 위해서는 FT-IR(DX-4000)을 사용하였다. 엔진부하는 50%, 75%, 100%로 변화시키면서 실험을 실시하였다. 실험 결과로, 엔진부하가 50%에서 100%로 변화함에 따라 미세먼지 저감 효율은 모든 부하 조건에서 94~98% 정도의 높은 저감 효율을 나타내었다. 추가적으로 습식전기집진기 퀜칭존에서 배기가스의 온도를 낮추는 과정 중 세정액에 의한 이산화황(SO2) 저감을 확인할 수 있었으며, 저감율은 엔진부하에 따라 55%~81%로 확인되었다.
        4,000원
        3.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        전 세계 90 %의 인구가 WHO의 연평균 미세먼지 노출 기준(10 ㎍/㎥)을 초과한 공기를 흡입하고 있다. 전 세계적으로 육상뿐 만 아니라 해양에서 발생하는 질소산화물에 대한 규제를 통해 2차 오염물질, 초미세먼지 저감에 대해 노력하고 있으며 국내에서는 선박에서 미세먼지 발생의 주요한 원인인 황 함유량 저감과 환경친화적 선박의 개발 및 보급 등을 통해 깨끗한 해양환경 조성을 위한 노력을 하고 있다. 디젤엔진 유해 배출가스 저감을 위한 기술 중 압력 손실이 적고 높은 집진 효율 및 NOx의 제거와 유지 관리의 장점이 많은 전기 집진기의 수요와 중요성이 증가하고 있다. 본 연구는 총톤수 999톤급 선박의 2,427 kW 선박용 디젤엔진의 미세먼지 저감을 목적으로 개발된 전기 집진기를 예지보전단계에서 고장모드영향분석을 통해 장비 품질을 높여 선박 내에서의 내구연한을 높이고자 위험 우선순위 도출하였다. 위험 우선순위는 고장모드 241(poor dust capture efficiency)이 RPN 180으로 가장 높았다. Collecting electrode 에서 가장 많은 고위험 고장모드를 검출하여 집중관리 부품으로 관리해야 할 필요가 있었으며 원인으로 진동과 핀 풀림으로 인한 유 격 불량이 가장 많이 검출되었다. 핀 풀림 역시 근본적으로는 선체 또는 장비에서 발생하는 진동이 원인이 되어 발생할 수 있는 사항이기 때문에 핀 풀림이 발생하는 개소에 보완이 필요하겠다.
        4,000원
        4.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A single-stage electrostatic precipitator (ESP) was evaluated in terms of its performance in removing dust in subway tunnels. A wire-to-plate type ESP was tested in a small-scale wind tunnel. The effects of wire-to-wire spacing (2040 mm) and the material connecting wire-to-wire on the performance of ESP were investigated, with varying applied voltage and airflow velocity. A narrower wire-to-wire spacing showed higher collection efficiency at the same applied voltage. Lower electrical resistivity of material connecting wire to wire was more effective. Ozone generation in subway tunnel applications was insignificant.
        4,000원
        5.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we numerically analyzed flow and particle transport near the electrostatic precipitator in the tunnel according to train runs. When there was no train running, flow field was formed by a precipitator. Flow emitted from precipitator blocks the path along the tunnel, and therefore most contaminated air passes through the precipitator and can be cleaned. On the other hand, flow pattern during the train run was affected by train induced wind. A strong straight flow was generated at the front of train, and back flow was formed in the opposite line. When a train runs upward only (train start from suction section to blow section), the subway train transports contaminated particles along the tunnel. For downward train runs only case, the cleaned air reentered the contaminated section with train wind. Both train runs case showed combined flow and particle concentration pattern of both single train runs.
        4,000원
        6.
        2012.09 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Particle collection efficiency and air cleaning capacity were tested for the two-stage electrostatic precipitator for use in indoor air cleaning systems. A wire-plate type ionizer was used as a particle charger and a dielectric film consisted of polypropylene (or polyethylene) coated metals and zigzagged metal electrodes was used as a particle collector in the electrostatic precipitator. Both particle collection efficiency and air cleaning capacity increased as increasing the applied voltage on the charger and the collector, and furthermore, as increasing the collector film width (i.e. collection area). Air cleaning capacities estimated by the product of particle collection efficiency and air flow rate were quite well consistent with the experimental ones with a proportional constant of 0.964. Ozone concentrations emitted from the charger at the applied voltages of 5.0 and 5.2 kV were less than 0.05 ppm, indoor ozone standards of UL 867-2002, KS C 9314 and SPS-KACA002-132. For the air flow rate of 11.7 m3/min, the applied floor area of 48.2 m2 could be obtained when 5.2 kV and 6.0 kV were applied on the ionizer and the collector, respectively and the collector of two 15 mm polyethylene dielectric films was used.
        4,600원
        7.
        2006.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Numerical analysis was conducted to characterize the particle charging quantities in the charging cell of a 2-stage parallel-plate electrostatic precipitator with respect to particle size. The numerical method took into consideration of particle charging rate equations and particle equations of motion, allowing the locally varying non-uniform electric field and ion number concentration along the particle trajectory. The charging rate model developed by Lawless (1996) was used in the present study. According to the present study, the numerical results showed good agreement with the available experimental data.
        4,000원
        8.
        2004.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Abstract Dielectric barrier discharge (DBD) in air, which has been established for the production of large quantities of ozone, is more recently being applied to a wider range of aftertreatment processes for HAPs (hazardous air pollutants). Although DBD has high electron density and energy, its potential use as precharging nano and submicron sized particles, is not known. In this work, we measured V‐I (voltage‐current) characteristics of DBD and estimated the collection efficiency of particles with bimodal distribution by DBD type 2‐stage ESP (electrostatic precipitator). To examine the particle collection with various applied voltage waveforms of DBD, nano size particles of NaCl (20∼100 nm) and DOS (50∼800 nm) were generated by an electrical tube furnace and an atomizer, respectively. Particle collection efficiencies of all the cases increased with increase of DBD electric power that the results corresponded to product of V by I whose magnitudes were the largest in triangular voltage waveform.
        4,200원
        9.
        2016.11 서비스 종료(열람 제한)
        염색가공 공정 중 텐터 후처리 과정은 섬유에 다양한 기능성을 부여하기 위해 화학약품 처리 후 건열에 의한 섬유의 셋팅을 하는 단계로 건조에 필요한 고온의 열원이 필요로 한다. 고온의 열원에 의해 기계작동을 위한 윤활유가 증발되면서 유증기(Oil-mist)형태와 각종 첨가제에서 증발된 오염성분이 함께 배출되게 된다. 또한 열원 에너지 특성상 150~160℃ 고온의 폐열이 상당량 발생한다. 염색가공 산업의 에너지 비용은 제품가격의 상승을 가져오고 있으며 이에 따른 저인금 개발도상국간의 경쟁력 저하를 발생시키고 있어 배기되는 폐열을 회수/재이용을 하는 시스템 도입이 시급한 과제이다. 기존 텐터후단에서 발생되는 폐열을 회수하기 위한 연구사례가 있지만 배기가스 중 함유된 분진 및 폐유로 인한 열교환 모듈의 폐쇄에 따른 열교환 효율 미비로 성공적인 상용화 모델이 없는 실정이다. 이를 해결하고자 섬유업종 텐터 후단에서 발생되는 고온의 배기가스를 전단 열교환식 스크라바와 건식전기집진 기술을 접목하여 폐열 회수와 동시에 악취유발물질인 폐유를 회수하고 회수 된 폐유는 정제연료유로써 재활용 가능성을 평가하였다. 본 연구를 위해 400CMM 규모의 열교환 스크라바 건식전기집진 시설을 부산에 위치한 ‘D’사의 염색가공업체에 설치하여 폐열에너지 회수량, 폐유 회수량, 회수된 폐유의 총발열량등을 평가 하였다. 평가 기술 적용대상 업체는 합섬 섬유(폴리에스테르)원료로 해포, 염색, 가공 등의 공정을 거쳐 염색된 화학섬유를 제품으로 생산하는 염색 가공업체로 360 m3 용량의 텐터 1대를 보유 하고 있다. 기존 개발된 건식전기집진시설의 낙모와 폐유로 인한 집진모듈의 오염으로 인한 관리 어려움을 개선하기 위한 열교환식 스크라바를 적용 하여 부산 염색공단내 보급화에 성공하였다. 운전 성능 평가 결과 회수되는 폐유는 0.032 L/m3・hr으로 평균 수분량 8.1~8.2%의 양질의 폐유를 회수 하였으며 발열량은 100,444 kcal/kg으로 B-C유 발열량과 유사 하였다. 배기가스에서 회수된 폐열(에너지)회수량은 평균 발생량 대비 67%인 16 kcal/m3・hr이며 암모니아와 톨루엔의 제거효율 70%이상의 우수한 결과를 나타냈다.
        10.
        2001.10 KCI 등재 서비스 종료(열람 제한)
        The main purpose of this study was to investigate the characteristics of cylindrical electrostatic precipitator with centrifugal effect in viewpoints of pressure drop and collection efficiency, experimentally. The experiment was carried out for the analysis of current-voltage, pressure drop and collection efficiency with various experimental parameters such as the applied voltage, inlet velocity, inlet size and inlet type(upper and bottom), etc. In the results, the pressure drops were estimated as 27∼54, 34∼63㎜H2O for inlet size 15㎜×3O㎜ and 30㎜×60㎜, respectively. The collection efficiencies were shown over 99% with the small inlet size(15㎜×30㎜) for the applied voltage 40㎸, inlet velocity(15∼21m/s), and 51∼89% with the large inlet size(30㎜×60㎜). Moreover, in the applied voltage 0㎸ and inlet size 15㎜×30㎜, the collection efficiency induced by centrifugal force was represented as about 35% with inlet velocity 15∼21m/s.
        11.
        1998.08 KCI 등재 서비스 종료(열람 제한)
        This study has been carried out to investigate Electrostatic Precipitator`s(ESP) performance enhancement and removal efficiency of fine particle according to (NH_4)_2SO_4 injection rate. The following conclusions are derived from the these test results : 1)For plant condition cases, according to the variation of concentration agent [(NH_4)_2SO_4] - 10ppm, 20ppm, 30ppm, 40ppm - ESP`s collection efficiency was increased to 97.74%, 98.95%, 99.04%, 99.47%, when inlet dust loading was 2g/㎥. And when inlet dust loading was 3g/㎥, that was increased to 98.19%, 99.16%, 99.23%, 99.58%. 2)It is seen from this experiments that the increasing 30ppm concentration of (NH_4)_2SO_4 increase the collection efficiency and fine particle emission control.