검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 22

        1.
        2023.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Benthic attached diatoms (BADs), a major primary producer in lotic stream and river ecosystems are micro-sized organisms and require a highly magnified microscopic technique in the observation work. Thus, it is often not easy to ensure accuracy and precision in both qualitative and quantitative analyses. This study proposed a new technique applicable to improve quality control of aquatic ecosystem monitoring and assessment using BADs. In order to meet the purpose of quality control, we developed a permanent mounting slide technique which can be used for both qualitative and quantitative analyses simultaneously. We designed specimens with the combination of grid on both cover and slide glasses and compared their efficiency. As a result of observation and counting of BADs, the slide glass designed with the color-lined grid showed the highest efficiency compared to other test conditions. We expect that the method developed in this study could be effectively used to analyze BADs and contributed to improve the quality control in aquatic ecosystem health monitoring and assessment.
        4,200원
        3.
        2019.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to increase the production efficiency of the ship and shorten the production cycle, it is important to evaluate the accuracy of the ship components efficiently during the drying cycle. The accuracy control of the block is important for shortening the ship process, reducing the cost, and improving the accuracy of the ship. Some systems have been developed and used mainly in large shipyards, but in some cases, they are measured and managed using conventional measuring instruments such as tape measure and beam, optical instruments as optical equipment, In order to perform accuracy control, these tools and equipment as well as equipment for recording measurement data and paper drawings for measuring the measurement position are inevitably combined. The measured results are managed by the accuracy control system through manual input or recording device. In this case, the measurement result is influenced by the work environment and the skill level of the worker. Also, in the measurement result management side, there are a human error about the lack of the measurement result creation, the lack of the management sheet management, And costs are lost in terms of efficiency due to consumption. The purpose of this study is to improve the working environment in the existing accuracy management process by using the augmented reality technology to visualize the measurement information on the actual block and to obtain the measurement information And a smart management system based on augmented reality that can effectively manage the accuracy management data through interworking with measurement equipment. We confirmed the applicability of the proposed system to the accuracy control through the prototype implementation.
        4,000원
        5.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        According as radiation therapy technique develops, standardization of radiation therapy has been complicated by the plan QA(Quality Assurance). However, plan QA tools are two type, OADT (opposite accumulation dose tool) and 3DADT (3 dimensional accumulation dose tool). OADT is not applied to evaluation of beam path. Therefore tolerance error of beam path will establish measurement value at OADT. Plan is six beam path, five irradiation field at each beam path. And beam path error is 0 degree, 0.2 degree, 0.4 degree, 0.6 degree, 0.6 degree, 0.8 degree. Plan QA accomplishes at OADT, 3DADT. The more path error increases, the more plan QA error increases. Tolerance error of OADT path is 0.357 using tolerance error of conventional plan QA. Henceforth plan QA using OADT will include beam path error. In addition, It will increase reliability through precise and various plan technique.
        4,000원
        6.
        2014.02 구독 인증기관 무료, 개인회원 유료
        Quality management system(QMS) made by international standard organization(ISO) for the testing and analysis bodies is increasingly required when countries trade their goods according to global trade regulations. This paper mentioned how to build the quality management system on domestic environmental measurement institutions and international trends on global environmental market. A conformity assessment system corresponded with the global standard and regulations has sharply been on the rise in all industrial fields as well as the environmental markets. Accordingly we should construct an appropriate QMS operation to promote analysis precision and spreading to all industrial sectors in order to survive on rapidly changing the current tendency of the times. Through this way, we can have global competitiveness. Especially, the settlement of a systematic and scientific quality assurance system is the key subject from the environmental analytical bodies to every societal industrial institutions.
        4,200원
        7.
        2012.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Microbial parameters of indoor air containing systematic, random, and accidental error were analyzed statistically by the water quality control guidelines to suggest a guideline of indoor air. Samples were collected from 20 subway stations of Seoul Metropolitan City. Systematic errors resulted from sampling devices were checked and removed by using same devices and flow rate check. Another source of systematic error resulted from different testing personals were assessed and qualified by proficiency test. Increase of replicate sample numbers could minimize random errors and use of geometric mean instead of arithmetic mean gave more statically reliable representative values for microbial parameters. Considerations for the culture media, colony counting results with incubation time, and statement of supplemented statistical data were also suggested.
        4,200원
        10.
        2010.04 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using quality assurance (QA) and quality control (QC) of diagnostic X-ray units. The surveys for QA/QC, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The QA/QC included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. As a result, 44.44% of reproducibility of dose exposure was proper, 81. 25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test.
        4,000원
        11.
        2007.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, QA/QC (quality control/quality assurance) data of reduced sulfur compounds from several institutes were obtained and compared based on the Korean standard method for off-odor. From the results, attempts were made to optimize the analytical conditions and improve the measurement reliability of reduced sulfur compounds analyses from detailed CF/TD and GC/PFPD information. Analysis results (minimum detection limit, precision, recovery rate) of reduced sulfur compounds based on the each analytical condition corresponded with the Korean standard methods for off-odor. Therefore, we expect that we could execute the exact analysis if we use the analytical condition of CF/TD and GC/PFPD in this study
        4,000원
        12.
        2005.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        콘택트렌즈 단백칠 침전물의 양은 착용하는 콘택트렌즈의 재질과 사용하는 관리용 액의 종류에 따라서 크게 다를 수 있다. 따라서 본 연구에서는 인공눈물을 이용한 m vitro 방법으로 Group 1, Group III, Group IV 의 소프트콘택트렌즈에 단백질 침전물 을 오염시킨 후 계면활성세척액과 다목적용액을 사용하여 콘택트렌즈뜰 세척하고 콘 택트렌즈에 남아있는 단백질을 Bradford 법으로 처리하여 다음과 같은 결과륜 얻었다. 세척 후 남아있는 단백질 침전물은 Group IV 렌즈가 Group 1 렌즈보다 16 레 이상 많았으며, 모든 재질의 렌즈에서 계면활성서l 척액은 다목적용액보다 세척효과가 우수힌 것으로 나타나 다목적용액으로 Group IV 렌즈틀 세착한 경우에는 계떤활성세척액으로 Group 1 렌즈플 세착한 경우보다 단백칠 침전물이 30 배 이상 증가하였다 그러나 실리 콘하이드로젤렌즈의 경우 비이온성, 이온성 재질에서 모두 단백질 침전불이 잘 부착되 지 않았으며 반복오염에 의해서도 침전물이 적게 부착되는 것으로 나타났다 따라서 단백질 침전물의 양은 렌즈의 재잘과 표면처리방법과 판리용액에 의해 영 향을 받는 것으로 사료된다.
        4,000원
        14.
        2020.08 KCI 등재 서비스 종료(열람 제한)
        This study presented problems and improvements in the quality control of an air monitoring network, using Gyeongnam as an example. 1) The effective utilization rate of the air monitoring was 95%, which showed good management, but the maximum of 2% was indicated by zero or detection limit among measurement data. 2) In the equivalence evaluation of PM2.5, the slope and intercept satisfy the evaluation criteria; however, 1% of the PM2.5/PM10 ratios were outliers. 3) All air monitoring stations meet the quality control standards; however, the management status is added to the quality inspection, management system is unified and the related budget is expanded, and systematic commission management is required.
        15.
        2019.02 KCI 등재 서비스 종료(열람 제한)
        최근 도입된 FFF 빔을 활용하는 방사선치료는 flattening filter에서 비롯되는 빔의 감쇠를 막을 수 있어 치료효율을 높일 수 있지만, 불균일한 단면적 선량분포에 대하여 정확한 정도관리가 구축되어 있지 않은 실정이다. 이에 본 연구에서는 광도전체 물질 HgI2 기반의 곡면 선량계를 제작하였으며, 성능을 검증하기 위하여 6 MV 광자에너지에서 재현성 및 선형성을 평가하였다. 또한 곡면 계측의 유용성을 나타내기 위하여 아크릴 필터를 적용한 FFF beam에서 평면 기판과 곡면 기판 상에서 계측되는 신호를 비교하였다. 그 결과 Unit cell 선량계의 재현성은 SE 0.613%, 선형성은 R-sq 0.9999로 나타났으며, line array 곡면 선량계의 유용성 평가는 평면 기판에서 23.337%, 곡면 기판에서 12.264%로 11.073%p 감소된 신호 차이를 보였 다.
        16.
        2018.10 KCI 등재 서비스 종료(열람 제한)
        PET와 PET/CT의 검사 영상품질관리를 위해서는 F-18 방사능측정기의 정도관리가 필요하다. Ge-68/Ga-68 Rod Sources을 선원을 이용하여 의료기관에서 사용하고 있는 5종류의 방사능측정기의 방사능 측정의 정확도와 정밀도를 확인하였다. CRC-15R, CRC-15 PET, CRC-712M, CRC-15 베타 및 CRC-25PET에 대한 측정값과 기준값 사이의 방사능 양에 따른 상관관계는 0.99999 (P <0.0001)로 매우 높은 선형성을 보였다. 정확도 테스트에서 CRC-15R, CRC-15 PET, CRC-712M, CRC-15 베타 및 CRC-25PET 모델은 각각 -3.232 %, -1.342%, -2.815 %, -2.913 % 및 -3.089 %를 이었다. 국내와 국제기준인 정확도 ±10%, 정밀도 ±5% 이내로 기준을 만족하였고 반감기가 짧은 F-18에 비하여 경제성 있고 비교적 긴 기간 동안 안정적으로 정도관리가 가능하다는 것을 확인하였다.
        17.
        2016.12 KCI 등재 서비스 종료(열람 제한)
        최근 다엽콜리메이터를 부착한 선형가속기를 이용한 방사선수술의 빈도가 점차 높아지고 있다. 이러한 정교한 방사선 수술은 소조사면 내에 고선량의 방사선이 집중적으로 조사되기 때문에 체계적이고 정확한 정도관리가 필수적이다. 본 연구는 PIB(Particle in Binder) 방식 중 침전법을 이용하여 400 ㎛ 두께의 요오드화납(PbI2)과 요오드화수은(HgI2) 광도전체 센서 시편를 제작하였다. 제작된 시편의 전기적 특성은 암전류, 출력전류, 응답특성 및 선형성을 평가하였다. 평가 결과, HgI2 가 우수한 신호발생량과 선형성을 보였다. 끝으로, 두께에 따른 HgI2 센서의 신호반응 특성 결과, 400 ㎛ 두께에서 신호발생효율이 가장 높았고, ±2.5 % 이내의 우수한 재현성을 보였다.
        19.
        2014.04 KCI 등재 서비스 종료(열람 제한)
        국내 진단용 방사선 발생장치는 3년 주기로 시행되는 정기적인 정도관리 검사에 앞서 일별, 주별, 월별, 분기 반기별로 시행하는 수시 정도 관리에 대한 항목 및 규정이 명확하게 지정되어 있지 않다. 미국과 유럽 등의 선진국에서는 정도 관리 항목에 대해 검사를 수행하는 검사자를 구분하여 국가 기관에 보고하도록 되어 있으므로 체계적인 검사 수행과 더불어 검토가 가능하다. 그러므로 의료 장비의 현대화가 이루어지는 시점에서 국외의 주기별 정도관리 시스템을 국내 진단용 방사선 발생 장치에 적합하도록 도입하여 정도관리 항목과 기준의 재정립이 반드시 필요하다. 이에 본 논문에서는 진단용 방사선 발생장치 중 가장 빈번히 사용되고 있는 일반 X선 촬영 장치의 3년 정기점검 사이에 주기적인 수시 정도 관리 검사 항목과 방법 및 기준 수립을 위해 미국, 캐나다 등의 국외 문헌 조사 및 국제 전자 기술 위원회(International Electro-technical Commission, IEC)의 규정 항목과 비교하였다. 이를 바탕으로 국내 수시 정도관리 항목 신설 시 필요한 검사 항목 및 기준 설정을 위한 기초 자료로 제시하고자 하였다.
        20.
        2009.03 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 지식공유와 지식관리시스템에 관한 이론과 선행연구를 통하여 해운 항만 공공부문과 해운기업을 대상으로 지식관리시스템 사용과 지식공유 의도에 영향을 주는 요인들을 추출하여 그 요인들의 상호 영향관계를 살펴보았다. 총 7개의 가설을 검증한 결과, 먼저 지식공유 의도의 영향요인들 중에서 최고 경영층의 지원, 자기 가치감, 신뢰가 지식공유 의도에 영향을 미치는 것으로 확인되었고, 또한 보상제도와 지식관리시스템의 사용과 관계, 지식공유 의도와 지식관리시스템 사용과의 관계 통계적으로 유의한 결과로 나타났다. 본 연구 결과는 앞으로 지식관리시스템 사용과 관련된 연구에 있어서 지식공유 의도의 영향력에 대학 실증적 근거로 제시될 수 있을 것이다. 또한 지식관리 시스템을 도입 사용하고 있는 기업의 실무자들에게 현재 자신들의 지식관리시스템 사용 현황을 재진단하고 문제점을 짚어봄으로써 향후 지식관리시스템을 통한 지식공유를 촉진하기 위한 방안을 모색하는데 기초 자료로 활용될 수 있을 것이다.
        1 2