Salinity is a major problem affecting crop production worldwide because it reduces yield and limits the expansion of cultivation. This study investigated the effect of irrigation water of different salinity levels on the growth and flowering characteristics of lily ‘Woori Tower’ and ‘Siberia’ cultivars. In both ‘Woori Tower’ and ‘Siberia’, the sprouting rate decreased and the sprout was delayed with increased irrigation water salinity. Plant height, leaf length, and leaf width decreased by 44.7%, 18.8%, and 20% in ‘Woori Tower’, respectively, and 50.7%, 36.4%, and 40% in ‘Siberia’, respectively at 0.5% NaCl compared to the control. Day to leaf yellowing was about 8 days earlier in ‘Woori Tower’ and 51 days earlier in ‘Siberia’ at 0.5% NaCl. SPAD decreased by 21.7% in ‘Woori Tower’ and 53.5% in ‘Siberia’ at 0.5% NaCl. In ‘Woori Tower’, flower height decreased by 9.6% at 0.5% NaCl, and the flower width and pedicel length gradually decreased as the salt concentration increased. Days to the flowering of ‘Woori Tower’ increased up to 3.5 days, as the salt concentration increased. The bulb characteristics of ‘Woori Tower’ also decreased. As the salt concentration increased, the Na+ and Cl- contents of the leaves of ‘Woori Tower’ and ‘Siberia’ increased, while the contents of K+, Mg2+ and Ca2+, decreased.
본 논문에서는 한국의 서남해상에 건설예정인 해상풍력발전타워의 지지구조물로 고려되고 있는 세발구조와 자켓구조의 선박충 돌 거동을 비선형동적해석을 통하여 비교‧분석하였다. 이 구조물은 3MW용량의 풍력타워를 지지하기 위하여 설계되었다. 두 지지구 조는 쉘요소를 이용하여 비선형 거동을 고려할 수 있도록 모델링하였고, 발전기를 포함하는 상부의 타워구조물은 탄성재료를 이용하 여 보요소와 집중질량으로 모델링하였다. 전체 질량은 세발구조가 자켓구조에 비하여 약 1.66배 정도였다. 바지선과 상선을 충돌선박 으로 선정하여 모델링하였다. 조수차의 조건을 고려하여 충돌선박의 충돌위치를 평균해수면의 상하로 3.5m변동하는 것으로 고려하 였다. 또한 각 선박의 최소충돌속도(=2.6m/s)에서의 충돌에너지를 각각 4배까지 증가시키면서 충돌거동을 산정하였다. 해석결과 지 지구조 충돌부위의 강성이 클수록 선박의 소성에너지 소산량이 상대적으로 증가하였다. 충돌조건에 따라 풍력타워의 변형은 진동에 서 붕괴까지 발생하였다. 세발구조가 자켓구조에 비하여 큰 충돌저항력을 보였다. 이는 중앙부에 강성이 집중된 구조적 특성과 상대 적으로 많은 강재의 사용량에 기인한 것으로 판단된다.
타워형 집광태양열발전의 핵심요소인 헬리오스타트는 경량화를 통한 설비비 저감이 매우 중요한다. 반사판 면적 16m2의 기 존 헬리오스타트 대비 샌드위치 패널을 사용하여 무게를 50% 경량화한 헬리오스타트의 풍하중 평가를 수행하였다. 반사판이 수직, 45 도 경사인 경우에 대해 전산유체역학 해석을 하여 반사판에 작용하는 풍압을 산정하고 구조해석을 수행하여 최대응력의 발생부위 및 반사판의 변위에 의한 반사각도의 이격을 계산하였다. 45도 경사진 반사판이 바람이 불어오는 반대편으로 향한 경우가 바람을 마주보 는 배치보다 최대 풍하중이 더 크게 나타났으며, 반사판 풍하측으로의 유동박리에 의한 후류의 발달도 반사판의 배치에 따라 매우 상 이한 형태를 보였다. 경량화 모델의 경우 반사판 구동을 위한 기어의 배치를 변경하여 핵심 지지체인 기둥의 강성을 확보할 필요가 있 음을 확인하였다.
As the size of the wind turbine tower becomes larger and larger, research on assembled wind turbine tower that is advantageous for transportation and installation is continuing. Large wind turbine tower require door openings for maintenance. The opening of the tower has an irregular cross section, and an excessive stress is generated due to the door opening. The result is structural damage to the tower and many accidents. In this research, stress analysis was performed on a model with internal stiffener to prevent excessive stress. The stress was investigated around the openings where the tower was resonant and excessive stressed, and the shape of the openings was optimized. Through optimization, we confirmed that the maximum stress was reduced by about 6% with respect to the initial value.
All structures can not be perfect due to geometric or material initial imperfections. Initial imperfections are an important factor in determining the buckling mode and are known to be important factors in evaluating the actual buckling strength. The DNV-RP-C202 design standard limits the longitudinal stiffener spacing. However, the criteria for the stiffener spacing presented in DNV-RP-C202 is a guideline derived from the curved panel theory of perfect cross-sectional shape without initial imperfections. In this study, considering geometric initial imperfections, the transition point of stiffener spacing where longitudinal stiffeners affect the buckling strength of reinforced steel wind turbine tower is analyzed using finite element analysis program. The results of finite element analysis compared with theoretical results based on the perfect shape. As a result, a more reasonable stiffener spacing considering the initial imperfections was suggested.
Wind tower structure has relatively simple shape compared to other structures, but due to its characteristics, various and irregular environmental loads are applied. These loads cause vibrations at tower, and can cause failure of the structure if over vibration occurs. Vibration occurred at structures is gradually exhausted by damping of the structures, and if high damping is ensured, the failure of the structure due to over vibration can be prevented. In this study, the vibration reduction effects are to be analyzed through FEM analysis by examining the top displacement, bottom moment, and bottom fatigue damage of the structure depending on damping ratio of the wind tower structure.
Recently, for efficiency increase of the wind turbine tower, turbine has been enlarged and installation location has been transferring to offshore. The importance of the support structure is emphasized when a wind turbine tower is installed on offshore. The support structure is influenced not only by the system operating loads but also by various marine condition loads. Accurate and safe design is essential because the connection between the support structure and the wind tower can be relatively fragile. In particular, the type of foundation pile and sleeve grout connection were adapted from DNV, API, and ISO that are typically used for wind towers, and they have been continuously studied by many researchers. However, the experimental results by researchers are different from the design equations, and it needs to modify the formula according to connection properties and material. Therefore, this study investigates the design equation presented in existing design criteria and the results of research conducted by existing researchers, and analyzes ultimate strength and failure modes.
This study investigates dynamic characteristics of a 2MW wind turbine structure by long-term response monitoring with accelerometers, tiltmeter and strain gauges. The object wind turbine structure is located in Jeju Island, Korea. The natural frequency and damping ratio were evaluated by least-square frequency domain decomposition and random decrement technique using acceleration response data. As a result, it was found that natural frequencies with 1st, 2nd and 3rd modes, and blade passing frequencies with 1P, 2P and 3P were clearly showed from power spectral densities of acceleration reponses. Furthermore, 1st model frequencies were almost constant with increase in standard deviations of acceleration responses. Another notable observation was that when standard deviations of acceleration responses were small, damping ratios showed to diverge. However, when standard deviations of acceleration responses had large values, damping ratios were converged to about 0.5%.
Cylindrical steel shell sections have been applied in various engineering fields particularly in recent installations of wind turbine towers. Hence, many researchers are interested in studying cylindrical steel shell structures. However, studies on the effect of the presence or absence of openings are insufficient. Thus, the design criteria for the opening as well as the behavior of wind turbine tower are not clearly presented. Therefore, this study examines the ultimate strength and the behavior of wind tower in consideration of openings, presence of stiffeners, changes in opening width, and thickness variation of stiffeners. ABAQUS, a universal finite element analysis program, was used in to conduct this research. Finally, the results of this study can be a reference for the design and production of wind towers with openings.
As the size of the wind power becomes larger, the development of the assembly type wind power which is advantageous in transportation and installation is active. This advantage comes from the economic point of view, and the stiffener is applied to the inner side, so that the safety is high. Large wind power require door openings for maintenance. The door opening has an irregular cross-section, and an excessive stress active due to the door opening. In this paper, the stresses occurring around the door opening was analyzed. As a result, small stress values were appeared in the tower, as the number of stiffeners were increased. Also, stress values were decreased a little in the tower as the opening shape become to ellipse was closer.
Construction sites have gradually become bigger and bigger according to Korea economic growth. Also use of tower crane and other heavy equipment has been increased. The increased use of heavy equipment like tower crane is leading to fatality incident. This study will verify hazards to influence tower crane incident through structural and positive verification and find which hazard influence incident risk. The result of this study is as follows. First, while there is a significant difference between safety managers and tower crane operators for working environment, safety management, personal manage among risk factors, we can not find any evidence on the difference in perception of tower crane incident risk between them. Second, task manage risk and personal manage risk has a significant positive effect on perception of tower crane incident risk. Third, while site environment risk has a significant positive moderating effect of task type between risk factors and perception of tower crane incident risk, personal environment risk has a significant negative moderating effect between them.
최근 신재생 에너지 중 하나인 풍력발전에 대한 관심이 증가하고 있다. 풍력발전은 토지구입비, 소음문제에 자유로운 해상풍력으로 추세가 옮겨가고 있으며 이를 위한 연구개발이 전 세계적으로 활발히 이루어지고 있다. 그러나 해상에 위치한 풍력발전을 위한 설계기준은 국내, 국외 모두 없는 실정이다. 이 점을 고려하여 국내, 국외의 구조설계기준인 도로교 설계기준, 항만 및 어항 설계기준, DNV OS를 참고하여 다중 파일기초 콘크리트 지지구조물(MCF)의 내진해석을 수행하여 결과를 비교하였다. 또한 시간에 의한 효과를 확인하기 위하여 시간이력 해석 또한 수행되었다. 부가질량법(Added-mass method)을 사용하여 물과 구조의 상호작용을 고려하였고 물의 유무에 따라 구조물의 반응을 비교하였다.
It is very important to calculate natural frequency of the observatory tower correctly because it is keenly affected by wind response vibration due to its large slenderness ratio, weight and small damping ratio. Additionally, suggestion equation of natural frequency being used in the design phase has considerable difference between actual measured value thereby making it inappropriate to be used in the serviceability design of the observatory tower. Therefore, this paper conducted an ambient vibration measuring on 10 observatory towers through mobile-phone application thereby calculating the natural frequency and comparing the result with the domestic and foreign standards and that of the eigen-value analysis. This paper suggested approximate equation of the natural frequency of the observatory tower; T=0.0266H. The square of the corelation coefficient is 0.940, which is high.
The initial production scale of wind tower is very few. But recently, the production scale of wind tower structure has increased gradually because it maximizes the efficiency in green energy. Many researchers are studying the wind tower, but there is no study about the difference of allowable buckling stress of the wind tower with and without opening. Guideline of codes and standards are very limited when designing a wind tower with an opening. It is also rarely that a study considers the design of the wind tower to be a tubular shell with or without an opening. ABAQUS, a general purpose finite element program, which provides safety evaluation and economical standards for the design and behavior of the wind tower considering the effect of opening was used in the study. Finally, results from this study can serve as reference for structural engineers, manufacturers and further studies of wind turbine when designing a tubular shell wind tower with an opening.
The study conducted statistical analysis of survey on the 239 workers participating in national Tower Crane installation/dismantlement in order to identify work environment and health hazard exposure of Tower Crane workers. Consequently for work related safety status of Tower Crane workers, the number of installation/dismantlement work was the highest at 15-20 times per month, and safety equipments were not arranged at work and they felt highly anxious when boarding on the Tower Crane. Furthermore, it is found that they feel anxious working in the influence of the weather, noise, vibration, wind, the sun ray, and structure characteristic. They have very low satisfaction in the insecureness of workplace and the work environment, and recognizes that their work affect highly on the health. 81.6% of workers have experienced accident at work, the cause of accidents were mainly due to poor work environment, and the health abnormality they have experienced were mostly fatigue and concentration reduction. For job stress, job demand and conflict in relationship were the highest sections. Total 66.5% of workers complained of musculoskeletal disorder related subjective symptom, and back pain patients were the highest of all groups.
Recently, wind power has received attention as one of remarkable renewable energy resources, and worldwide researches about wind power are actively being proceeded. Wind turbine tower has a major role for safety in the wind turbine systems. It is necessary for design tower structure to consider various environmental conditions. Earthquake, as one of the such environmental loads, is ground motion that applied to bottom of the tower structure and has a possibility of critical effect to the wind tower structure. There are various ways for seismic analysis, but design specifications that are in use do not suggest detailed method for seismic analysis. In this study, seismic responses are analyzed through different ways and the adequacy of seismic design methods is examined.
This study analyzes buckling in the lower segment of a tubular steel shell that exhibits the characteristics of a 3MW wind tower with opening and reinforcement. Analytical method using parametric equations based on Eurocode 3 - Design of Steel Structures and numerical method of finite element are used to analyze the critical meridional buckling stress. ABAQUS, a finite element program, is used for the numerical method analysis. Four different cases of tubular steel tower is modeled: without door opening and without reinforcement; with door opening and without reinforcement; without door opening and with reinforcement; and with door opening and with reinforcement. Using the ABAQUS, a linear buckling analysis is done for all cases to recognize five of its buckling mode shapes and its corresponding eigenvalues. Mode shapes from the previous analysis are considered in performing the non-linear analysis using Static Riks. Buckling capacity and its trends in the localized area near the opening is investigated, tabulated and shown in illustrative charts. Moreover, comparison is made between the parametric and finite element analyses.