        1.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, as there are many cases of fires occurring due to the failure or inoperability of the thermostat of electronic products, the purpose is to test and analyze the risks and probabilities through fire cases and reproduction experiments, and suggest countermeasures. Among electronic products, water purifiers are composed of a refrigerant system with a compressor to make cold water, a heating device to make hot water, and an electric device used as an energy source. Due to the nature of the water purifier manufacturing, these devices are subject to a lot of moisture and dust. etc. exist in large quantities and use electrical energy, so there is a possibility of fire due to short circuit in the wire, electrical abnormal overheating (tracking phenomenon) in the thermostat, electronic board, starting relay, etc., and overheating of the heating device (Band Heater). there is. Therefore, in order to prevent fires from these devices, a system to remove foreign substances inside the water purifier is necessary, the use of heat-resistant (fire-resistant) wires for electrical devices is essential, and the use of non-combustible materials (semi-combustible materials) for each part is necessary to prevent fire. The risk must be eliminated through prevention and combustion expansion prevention devices.
        4,000원
        2.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        필로티 공간은 일반적인 건축부재와 달리 부재가 외기와 접해 있고 실내에서 발생 가능한 화재와 가연물의 종류 및 배치 등이 달라 다양한 화재의 위험으로부터 노출되어 있다. 필로티 구조는 기둥으로만 이루어진 사방이 트인 구조로 인해 화 재가 발생할 경우 화재피해를 입은 기둥은 강도 및 강성이 저감되고 부재의 저항성이 저하되므로 단시간 안에 온도가 상승하여 구조체에 영향을 미친다. 이러한 문제점이 발생한다면 건축물 파손으로 인해 피난로를 차단당하여 많은 인명피해가 일어날 것 으로 사료된다. 본 연구에서는 다가구주택의 필로티 공간에서 화재 발생으로 인해 철근콘크리트 기둥에 미치는 화재영향을 확 인하고자, 기둥 국부화재실험을 통해 보강재에 따른 RC 기둥의 온도분포 및 파괴양상을 검토하였다.
        4,000원
        5.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        필로티 공간을 주차장으로 활용할 경우 차량 화재에 대한 위험성이 발생한다. 한 대의 차량에서 화재가 발생하게 되 면 차량 간의 거리가 밀접하므로 주차되어있는 여러 대의 차량에 화재가 빠르게 전이되며 차량의 높은 열방출율과 온도로 인해 폭발 위험성이 있다. 이러한 화재에 취약한 필로티 구조 특성으로 인해 짧은 시간 동안 주차공간이 화염에 휩싸이게 되며 화재 가 확대되어 주변 건물까지 화재 위험이 발생할 수 있다. 본 연구에서는 필로티 주차공간 실화재 실험을 통해 화염의 성장크기 와 전파속도에 따라 필로티 기둥의 미치는 영향을 분석하였으며, 화재에 노출된 CN준불연 및 CFRP 보강 필로티 기둥의 내화 및 연소성능을 평가하고자 한다.
        4,000원
        7.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        육상 및 해상에서의 화재 사고는 심각한 인명피해를 발생시키며 특히 해양 플랜트 및 선박의 특성 상 밀폐공간으로 인한 질식 사고 사망률이 육상보다 현저히 높다. 이러한 질식사고를 예방하기 위하여 화재에서 발생하는 유독가스를 외부로 배출할 수 있는 환기용 팬의 설치가 필수적이나, 해양화재의 규모를 고려하였을 때 대형 환기용 팬의 설치는 해양 구조물 특성상 용이하지 않다. 따라서 본 연구 에서는 DC 전기장을 인가하여 화재 유독가스를 제어하는 새로운 개념의 소방기술을 개발하고자 한다. 화재 발생 시 대부분의 화염은 화학 이온화로 인해 양전하와 음전하를 다수 함유하고 있고, 이때 전기장을 인가하게 되면 로렌츠 힘에 의해 “이온풍”이 발생하게 된다. 이러한 이온풍을 활용하여 일반건축물과 선박의 단열재로 많이 사용되는 종이와 스티로폼을 연소하여 발생되는 화재연기를 인위적으로 제어하는 실험적 연구를 수행하였다. 실험 결과, ± 5 kV 이상의 직류전압을 인가하였을 때 화재연기를 인위적으로 제어할 수 있었고, 양전압 보다 음전압을 인가하였을 때 상대적으로 효과적인 제어가 가능하였다.
        4,000원
        8.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed ignition probability about Lithium-polymer batteries of what variously were being produced wearable devices recently. The study analyzed ignition probability by PCM(Protection Circuit Module) operating state and overcharged, over-discharged, exposed to high temperatures of Lithium polymer batteries, analyzing wearable devices on the market. Then it classified experimental results to implement analysis comparison about weight, X-ray imaging, battery decomposition. With these experiments, the study analyzed combustion-possibility and fire patterns. These statistics will be used to measure and verify the cause of a fire when identify wearable devices using Lithium-polymer batteries.
        4,000원
        9.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper recognizes the risk of ignition of air fryer (machine that can cook fried dishes with hot air without oil) that is far exceeding the sales rate of microwave ovens, which is necessary to modern household kitchen, and identifies fire risk through the operation principle of the process of heat transfer, and the main structure of the machine. The fire test that we conducted is to observe the risk of ignition of the machine due to the damage to the safety system and the possibility of igniting oil paper along with food, to experiment with the possibility of ignition due to blockage of the exhaust due to obstacles, and accumulation of oil stains on the hot wire, and to present the method of fire control and devise countermeasures.
        4,000원
        10.
        2011.11 구독 인증기관 무료, 개인회원 유료
        Development of the economy and the growing income of people interested in the leisure and health has been focused. Past the town common wells and groundwater around the water, but health is a priority these days to solve the drinking water directly from tap water, but most people work from home, through the water purifier has been resolved. Depending on seasonal changes and personal taste of coffee, if you can enjoy a snack and water purifier is a restaurant, lounge, public areas and focusing on the rapid spread of the fire, water purifier as compared to the total number of fires increased by 0.03% per year trend on, but the washrooms fire and fire-related research data and case studies with analysis of the exact cause lack of proper preventive measures are insufficient reality. In this study, focusing on electrical energy using a water cooler to understand the structure and principles of fire, the fire revealed the mechanism is vulnerable to the consideration of factors, the exact cause of the fire investigation and the Assistant, manufacturing defects, and to contribute to fire prevention review should.
        6,400원
        11.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This is to show some basic data for introducing both circulated aggregate and recycled powder producing waste concrete. Standard-mixing design for 24MPa has been basically used and added and replaced normal aggregate with recycled powder made of waste concrete. In addition, polycarboxylate high-range water reducing agent has been used because recycled powder is missing adhesive strength and it is not compare with cement's adhesive strength. Compressive strength with powder mixture of 2%, 4%, 6%, 8%, and 10% has been decreased down to 80% of normal concrete material strength without recycled powder mixture. 200℃, 400℃ and 600℃ heated concrete were compressively tested in order to find out concrete strength resistant to high temperature. heat capacity was also tested, based on the expectancy of its low conductivity. In addition, thermal conduction test was tested in order to find out concrete insulation. According to this test, when concrete was tested by fire resistance, it using the circulation aggregate was same resulted by concrete using the natural aggregate. also, recycle powder was not effecting insulation performance. but it is fit to standard on concrete insulation of building law.
        4,000원
        12.
        2010.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, in circumstantial situation it is recommended positively to utilize of EIFS(Exterior Insulating and Finishing System) as energy policy for economizing energy. But internal EPS insulators of EIFS are exterior panel of high fire risk, because of constituting of flammable materials to be fragile in fire. In this study, fire risk is assessed by experiment Con Calorimeter test and SBI(Single Burning Item) test. As the result of experiment, Con Calorimeter tests do not reach to capability standard of internal incombustible grade, and are assessed as low grade in SBI incombustible grade. Because EIPS is exterior material in buildings with high fire risk in spite of good efficiency, it is required rapidly to take measures to meet situation through various studies(for instance, adjusting law regulation, etc.) in the future.
        4,000원
        13.
        2008.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to distinguish the causes of broken glass on doors or windows when it is originally kept among the remains on the floor in fire site - whether it was broken due to heating or outer power-through test and characteristics of the broken plane including the pattern on the plane. Addition to it, the study tries to find characteristics to judge the point and direction of breakdown through the analysis of glass broken by outer power. With two assumed causes - a) breakdown due to heating and b) breakdown due to outer power-3 pieces of glass plates (30cm×30cm×5mm) were tested for each case, getting the results as following: First, for the glass broken due to the change of temperature, the broken plane is of slow and smooth curve without any pattern. Second, for the glass broken due to outer power, with the impact point as the center, the glass shows breakdown of radial type and the side shows breakdown of near-perpendicular type. The far the broken piece is from the impact point, the bigger the size is. The broken piece at the impact point is of long triangle type and the two long planes of the triangle shows semi-arc with the center of breakdown point and the other plane shows opposite pattern. Third, when glass that is damaged by outer power is heated, damaged forms and side patterns of the glass that is damaged by outer power are heated and disappeared.
        4,000원
        14.
        2008.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This Study is to analyze the characteristics of arson fire under fire dynamics to protect people and property from arson fire which has been radically increased with the development of the Korean economy. Assembly and merchandise purposes such as theater, retail, and exhibition has been performed as the arson fire study. The experiment for this study is based on the analysis of the characteristic for its own combustion process and smoke spread when arson fire occurs. This study presents the analysis through comparing the condition of setting fire using liquid fuel such as thinner on purpose to the condition of setting fire naturally depending on each occupancy.
        4,500원
        16.
        2016.05 KCI 등재 서비스 종료(열람 제한)
        콘크리트는 내화재료로서 우수한 성능을 발휘하지만 화재가 지속됨에 따른 재료특성 변화 또는 성능저하의 위험을 갖는다. 이 연 구는 실물모형 철근 콘크리트 (RC) 보를 활용하여 비재하 화재 실험을 수행하여 화재노출 전후의 콘크리트 및 보강철근의 재료특성을 실험적 으로 분석한 연구이다. 화재실험에 사용된 보는 길이 4 m의 RC 보로서 KS F 2257 화재실험 규격에 따라 시험 체를 제작 및 화재실험을 수행하 였다. 화원의 가력은 ISO 834의 표준화재 곡선을 사용하였으며 보 가열부에서의 온도를 계측하고자 하면 및 측면에 열전대를 설치하였다. 실 험결과, 화재에 노출된 화재 코어 공시체의 경우 약 11 MPa로 약 66%의 강도저하가 발생하였다. 화재에 직접 노출된 철근의 경우 노출되지 않 은 철근에 비해 약 17%에 해당하는 75 MPa의 항복강도 저하를 나타낸 것으로 분석되었다. 철근의 경우 콘크리트라는 내화피복에 의하여 보호 되어 약 4시간의 화재 실험에서도 온도는 한계온도의 최댓값인 649°C를 크게 상회하지 않는 것으로 나타났다.
        17.
        2014.09 KCI 등재 서비스 종료(열람 제한)
        최근 도로터널은 비용절감 및 자연보호를 위하여 설계 및 시공이 증가되고 있는 추세이며, 이 때문에 반밀폐 구조인 터널내의 화재에 대비하여 화재 발생 시 신속히 감지할 수 있는 연구가 활발히 진행 중이다. 그 중에서도 광섬유 센서를 이용한 화재 감지법은 대역폭이 넓기 때문에 전송속도가 빠르고, 빛을 매개체로 하여 전기적인 간섭을 받지 않아 전송 도중에 정보 손실이 거의 없을 뿐만 아니라 노이즈 또한 적은 장점을 가지고 있어 이에 따른 연구와 현장 적용이 이루어지고 있다. 이와 관련하여 본 논문에서는 형상기억합금과 광케이블을 이용하여 실시간으로 화재 발생위치를 정확하게 감지할 수 있는 화재 감지 시스템을 개발하였다. 개발된 방법의 검증을 위하여 실내에서 온도변화에 따른 광 손실량 측정 실험을 수행하였으며, 거리 및 온도 등의 외부환경이 다른 지하공동구에 test bed를 설치하여 화재 모의실험을 수행하였다. 실험 결과 본 연구에서 개발한 화재감지시스템은 실시간으로 장거리 구간의 화재를 감지할 수 있는 것으로 나타났다.
        18.
        2014.02 서비스 종료(열람 제한)
        샌드위치패널은 시공상의 용이함과 비용대비 높은 단열효과를 가지는 장점으로 공장 및 창고등 많은 분야에서 시공이 이루어지고 있다. 하지만 지난 안성 냉동창고 화재사고에서 볼 수 있는 가연성 패널이 가지는 화재확산 위험성이 상존하고 있어 대형 화재사고의 주범으로 지목되고 있으며, 소방활동을 하는 일선 소방관들에게 큰 위해 요인으로 작용하고 있다. 본 연구에서는 이러한 샌드위치패널의 화재위험성을 평가하기 위하여 가연성 패널과 글라스울 패널의 비교실험을 실시 하였다. 실험을 위하여 ISO 9705에서 제시된 구획실을 구성하였으며 내부에는 목재크립을 적재하여 화재를 모사하였다. 실험결과 가연성 패널의 경우 화재발생 후 약 2분후에 플래쉬오버가 발생하여 붕괴가 진행되었으며, 내부 최대온도는 976℃로 고온으로 측정되었다. 따라서 현재의 시편크기의 시험에서는 평가하기 어려운 구조적 안정성등 종합적인 화재 안전 평가를 위한 실규모의 화재 성능 평가법(KS F ISO 9705등)의 도입이 적극 검토되어야 할 것으로 평가된다.
        19.
        2014.02 서비스 종료(열람 제한)
        최근 초장대 교량, 초고층 빌딩 등 토목 및 건축 분야에서 초고강도 콘크리트에 대한 수요가 날로 증가추세에 있다. 특히 초고층 건축물 건립에 따른 고강도 콘크리트 사용이 증가함에 따라 화재시 폭렬현상 등 내화성능 저하에 대한 대책마련의 일환으로 설계기준강도 50MPa 이상의 고강도 콘크리트에 대하여 내화성능관리기준을 법령으로 제정하여 시행하고 있다. 이에 따라 고강도 콘크리트의 내화성능 확보를 위한 연구가 다수 진행되었지만, 100 MPa 이상의 초고강도 콘크리트에 관한 연구는 거의 전무한 실정이다. 초고강도 콘크리트의 경우 내부 조직이 고강도 콘크리트에 비해 훨씬 더 치밀하여 고강도 콘크리트에 적용되는 일반적인 내화 방안으로는 화재시 내부 수증기의 배출이 어렵다. 뿐만 아니라, 화재시 또는 화재후의 구조적 성능에도 일반적인 고강도 콘크리트와는 다른 양상을 나타낼 수 있어 이에 관한 연구가 필요하다. 따라서 본 연구에서는 화재 상황 하에서 초고강도 콘크리트 기둥이 소정의 하중을 지지할 수 있는 구조 성능의 확보 방안을 모색하고자 하였다.
        20.
        2014.02 서비스 종료(열람 제한)
        건축물에서의 성능기반 화재안전 설계를 위해서는 우선적으로 구획 내에서의 화재성장 및 크기를 예측하고 이 결과를 통하여 연기제어 및 피난 활동 등을 평가할 수 있다. 따라서 본 연구에서는 실규모의 구획 화재실험을 통해 구획 공간에서의 화재성장 및 크기를 예측하고자 하였다.