검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 51

        1.
        2024.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The operating parameters considered in this study include evaporating and condensing temperature, degree of subcooling and degree of superheating. in R744-R717 cascade refrigeration system and R744 two-stage compression refrigeration system with the range of low temperature -50℃∼-30℃. The coefficient of performance(COP) of R744-R717 cascade refrigeration system is about 16∼20% greater than that of R744 two-stage compression refrigeration system in the range of evaporation temperature of -50℃∼-30℃. R744 two-stage compression refrigeration system is unstable because its coefficient of performance changes significantly depending on the evaporating temperature and total compression work, and compression efficiency decreases. In this case, not efficient for long-term use. Whereas R744-R717 R744-R717 is a cascade refrigeration system using eco-friendly refrigerants. And this system is a high-efficiency refrigeration system that performs well even under various operating conditions. This is why it can be configured by selecting a refrigerant suitable for the high temperature side and the low temperature side.
        4,000원
        2.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 중공사형 이산화탄소 분리막 모듈을 사용하여 수소개질기 배가스로부터 이산화탄소 포집을 목적 으로 한 분리막 공정 최적화 연구를 진행하였다. 랩스케일의 소형 분리막 모듈을 사용하여 혼합기체를 대상으로 이산화탄소 순도 90% 및 회수율 90%을 달성하는 2단 공정 조건을 도출하였다. 막 면적이 정해진 모듈의 분리막 공정에서는 스테이지-컷, 주입부 및 투과부 압력에 따라서 포집 순도 및 회수율이 모두 다르게 나타나기 때문에 운전 조건에 대한 최적화가 필수적이 다. 본 연구에서는 다양한 운전 조건에서 1단 분리막에서 보이는 공정 포집 효율의 한계를 확인하고, 높은 순도와 회수율을 동시에 달성하기 위한 2단 회수 공정을 최적화하였다.
        4,000원
        3.
        2023.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Gymnocalycium mihanovichii has been an important export item of Korean flower industry for a long time. Although there is a high demand for grafted cactus from overseas, its production for export is limited. In this study, the growth and marketable yield characteristics of Gymnocalycium mihanovichii ‘I-Hong’ were compared between soil culture and ebb-and-flow hydroponic system with single- or double-tier bench. As a result, hydroponic methods with single-tier bench resulted in higher fresh weight and glove diameter compared to other cultivation methods. In the ebb-and-flow hydroponic system, hydroponic system with double-tier bench of grafted cactus traits has a lower growth rate than other cultivations. However, the hydroponic system with double-tier bench of grafted cactus significantly increased the yield. In conclusion, the yield from hydroponic system with double-tier bench was better than soil cultivation method. Although there were some differences in color depending on the cultivation method, it was considered that there was no difference in appearance of Gymnocalycium mihanovichii ‘I-Hong’. Our results suggest the cultivation methods to overcome production constraints, expand their exports, and improve the value-added characteristics of grafted cactus.
        4,000원
        4.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a two-stage electrostatic precipitator (ESP) was developed using a novel automatic dry cleaning device to reduce the ultrafine particles in subway stations. Collection efficiency was evaluated with a pilot scale ESP (1.2m× 1.2m) and the scale of the test duct was half of the subway air handling unit. The maximum collection efficiency for 0.3 μm particles was 96.9%. In addition, we studied a method of automatic dry cleaning for maintenance of the ESP. The cleaning efficiency was analyzed according to the cleaning flow rate for each particle loading amount to achieve a recovery rate over 90%. In addition, we derived the equation to estimate the reduction in collection efficiency according to the particle loading amount. It was confirmed that the performance of the contaminated ESP was restored to the initial state by the automatic dry cleaning in this study and that the electrical energy consumption was 5 times lower compared to utilizing conventional water cleaning.
        4,200원
        5.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        밀러 사이클은 흡입밸브 닫힘 시기 조정을 통해 압축비를 줄임으로써 NOx의 저감과 연료소비율 개선이 동시에 가능하다는 점 (밀러 효과)에서 디젤엔진에 매우 활발하게 채택되어지고 있다. 밀러 사이클은 흡입 밸브를 BDC 이전에 닫는 Early 밀러 방식과 BDC 이 후에 닫는 Late 밀러 방식으로 나눌 수 있다. 저속에서는 체적효율의 증가를 꾀할 수 있는 Late Miller가 유리한 반면, 중속, 고속에서는 IVC 이후 BDC 까지의 피스톤 하강 과정의 흡기의 팽창에 따른 내부 온도 감소 효과 높은 Early 밀러가 유리하다. 따라서 Early 밀러와 Late 밀러의 효과를 고려하여 운전 조건에 적합한 밀러 구현 방법을 채택할 필요가 있다. 본 연구에서는 4행정 엔진을 대상으로 2단 과급 시스 템의 적용하고 흡·배기 밸브 오버랩(valve overlap)의 감소를 통해 밀러 효과를 강화하는 과정과 밸브 조정 기구를 통한 밸브 조건의 변화 가 밀러 효과에 미치는 영향을 고찰하였다. 결과적으로 2단과급과 밀러사이클, 밸브 오버랩 감소와 흡입밸브 리프트 증가를 통해 연료소 비율과 최고연소온도 감소의 효과를 확인하였다.
        4,000원
        7.
        2018.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 2단 베드 벤치 시스템에서 딸기를 재배하는 동안 상단베드에 의한 차광으로 광량 부족한 하단 베드에서 자란 딸기의 생산량 및 과일 품질에 LED 보광의 영향을 확인하기 위한 것이다. 딸기 전용상 토로 충진된 2단 베드 벤치에 2015년 10월부터 2016년 1월까지 점적 관수로 딸기를 재배하였다. LED 광이 처리되지 않은 상단과 하단 베드를 대조구로 이용하였고, LED 광 처리를 위해서 오전 10시부터 오후 4시까지 하 단 베드에 각각 청색, 적색, 그리고 청색과 적색을 혼합 한 LED 광을 100μmol·m-2·s-1의 광량으로 보광 하였다. 딸기의 수확량에 있어서, 하단 베드의 청색 LED 보광된 처리에서 자란 딸기는 하단 부분 대조구와 비교하여 유의하게 증가되었으며, 상단 베드 대조구에서 자란 딸기 생산량의 90% 수준까지 증가되었다. 청색 및 혼합 LED와 상단베드에서 생육된 딸기 과일의 유리당 함량은 적색 LED와 하단 베드 부위 대조구에 비하여 높았다. 안토시아닌의 함량은 자연 광을 많이 받는 상단 베드에서 생육된 딸기 과일이 가장 높았지만, 하단베드 처리만을 비교하할 때, LED를 보광한 모든 딸기과일이 보광하지 않은 하단 부분의 대구조의 딸기 과일보다 높았다. 따라서 딸기 2단 베드 재배 시 하단 베드에 청색 LED 보광이 생산 증대 및 품질 향상에 유리할 것으로 판단된다.
        4,000원
        9.
        2016.11 구독 인증기관·개인회원 무료
        수처리에 있어 막여과 기술은 안전한 처리수질의 보장, 시스템의 집약화 및 자동화 등의 장점으로 인해 활발히 도입되고 있다. 하지만 핵심 기자재인 막 모듈의 설계나 전체 정수처리 공정의 안정성 부분에 대해서는 아직 기술개발의 여지가 남아 있다. 본 연구에서는 막여과 공정의 연속 운전에 있어서 막오염을 완화시키기 위한 목적으로 수행하는 물리적인 역세척의 효율 향상과 더불어 이 때 발생하는 역세배출수를 막 모듈 외부로 원활히 배출할 수 있도록 한 가압식 막여과 기술과, 이 때 발생한 가압식 막여과 배출수를 이중 구조로 구획된 침지 막조 이용하여 원활히 처리할 수 있는 침지식 막여과 기술을 결합하여 기존 기술에 비해 고회수율의 달성은 물론, 집약적이고 실용적인 2단 막여과 정수처리 시스템을 개발하고자 하였다.
        10.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        메탄을 순도 95% 이상으로 분리, 회수하기 위하여 메탄에 대한 분리특성이 우수한 폴리설폰 중공사 분리막 모듈 을 2단으로 연결하고 재순환 흐름을 이용하여 회수율을 90% 이상으로 유지할 수 있도록 공정을 설계하였다. 이렇게 설계된 2단 공정을 통한 메탄 분리 거동 특성을 이론적으로 예측하기 위하여 Compaq Visual Fortran 6.6 소프트웨어를 이용하여 수 치 해석하였다. 개발한 프로그램을 사용하여 수치 해석을 수행한 결과 공정 변수에 따라 최종 메탄의 농도 변화에 미치는 영향을 고찰할 수 있었다. 공급 기체 압력과 분리막 길이와 공급측 메탄 농도 증가, 유량이 감소함에 따라 최종 생산물 내 메탄 농도 증가를 관찰할 수 있었으며, 메탄의 회수율은 감소함을 알 수 있었다.
        4,000원
        11.
        2016.06 구독 인증기관 무료, 개인회원 유료
        α-Amylase 및 protease 활성을 동시에 가지는 1-B-12 균주를 된장으로부터 분리하였다. 16S rRNA 유전자 염기서열 분석결과, Bacillus licheniformis로 동정되어 B. licheniformis 1-B-12 균주로 명명하였다. 효소활성 측면에서 현미(50%), 미강(30%) 및 대두(20%)의 조합이 최적의 기질 조합 조건으로 확인되었다. 기능성이 부가된 효소식품을 제조하기 위하여 Lactobacillus casei GW140 균주를 도입하였는데, B. licheniformis 1-B-12 균주와의 혼합배양 조건은 2단발효(B. licheniformis 1-B-12 접종 > 24 h 발효 > L. casei GW140 접종 > 12 h 추가 발효)가 적합한 것으로 나타났다. 이러한 최적 조건으로 생산된 효소식품을 동결건조하여 25℃에서 보관하였을 때 시험 마지막 날인 45일까지 효소의 활성이 유지되었다.
        3,000원
        12.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study has implemented an experiment in which hydrogen sulfide was removed by establishing a two-stage packed tower effector filled with nutritious medium and also filling a tower that was immobilized in ceramic media after isolating and identifying the sulfur oxidizing bacteria from a sewage treatment plant. As a result, strains isolated from the sewage treatment plant were found to be similar, including Bacillus fusiformis, Bacillus anthracis sp., Paenibacillus sp., Serratia marcescens sp., Bacillus thuringiensis. The effector that immobilized isolated strains in the ceramic media achieved an approximately 90% removal rate of hydrogen sulfide, while the sterilized ceramic media not immobilized with isolated strains showed a removal rate of about 65%. In addition, the removal rate of hydrogen sulfide in the primary media packing effector immobilized with sulfur oxidizing bacteria was about 92%, while the secondary effector filled with medium had a hydrogen sulfide removal rate near 100%. In addition, 90% efficiency of removal was shown in conditions of EBCT 60s in the experiment that investigated removal rate of hydrogen sulfide according to residence-time, while the efficiency was rapidly reduced up to 45% in conditions of EBCT 30s. On the other hand, when operating for an extended period time while increasing the concentration of injected hydrogen sulfide, the amount of sulfate was increased from 2 mg/L to 12.7 mg/L, and pH was rapidly reduced to 2.7.
        4,000원
        13.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study has implemented an experiment in which hydrogen sulfide was removed by establishing a two-stage packed tower effector filled with nutritious medium and also filling a tower that was immobilized in ceramic media after isolating and identifying the sulfur oxidizing bacteria from a sewage treatment plant. As a result, strains isolated from the sewage treatment plant were found to be similar, including Bacillus fusiformis, Bacillus anthracis sp., Paenibacillus sp., Serratia marcescens sp., Bacillus thuringiensis. The effector that immobilized isolated strains in the ceramic media achieved an approximately 90% removal rate of hydrogen sulfide, while the sterilized ceramic media not immobilized with isolated strains showed a removal rate of about 65%. In addition, the removal rate of hydrogen sulfide in the primary media packing effector immobilized with sulfur oxidizing bacteria was about 92%, while the secondary effector filled with medium had a hydrogen sulfide removal rate near 100%. In addition, 90% efficiency of removal was shown in conditions of EBCT 60s in the experiment that investigated removal rate of hydrogen sulfide according to residence-time, while the efficiency was rapidly reduced up to 45% in conditions of EBCT 30s. On the other hand, when operating for an extended period time while increasing the concentration of injected hydrogen sulfide, the amount of sulfate was increased from 2 mg/L to 12.7 mg/L, and pH was rapidly reduced to 2.7.
        4,000원
        14.
        2015.11 구독 인증기관·개인회원 무료
        폴리설폰 분리막을 이용한 바이오 메탄 가스 농축 특성을 수치 해석적 방법으로 분석하였다. Compaq Visual Fortran 6.6 소프트웨어를 사용하여 분리막 모듈 2단 공정을 수치 해석하였다. 전산 모사 결과 다음과 같은 결과들을 얻을 수 있었다. 공급측 압력이 높고 분리막 면적이 넓고 공급 유량이 적고 공급 기체 내 메탄 몰분율이 낮을수록 메탄의 순도는 높아지고 회수율은 감소함을 알 수 있었다. 주어진 전형적인 메탄 공급 농도 0.5 몰분율 조건에서는 2단 공정으로는 메탄 순도 95%와 메탄 회수율 95%를 얻기 어려우므로 이와같은 목적을 충족시키기 위해서는 3단 공정으로 구성하거나 공급 기체 내의 메탄 순도를 어느 수준 높일 필요가 있을 것으로 판단된다.
        15.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 딸기의 2단 고설베드재배가 끝난 여름철 동안 수박재배 시, 베드 위치와 재식밀도가 수박의 과실 품질에 미치는 영향을 구명하고자 하였다. 고설 베드상자는 길이 102cm, 폭 22cm, 높이 13cm의 규격이고, 배지는 코코피트(coir)를 사용하였다. 수박은 베드 위치 및 재식밀도에 따라 베드상단 1주(A), 베드 상하단 각 1주로 상단(B) 및 하단(C), 상하단 각2주로 상단 2주(D), 하단 2주(E)로 정식 처리하였다. 수박은 2012년 5월 8일에 2단 고설베드에 정식하여 양액과 점적관수로 재배하였고 7월 25일에 수확되었다. 수박의 품질을 비교하고자, 과실 무게와 크기를 조사하였고, 과육 내 비타민 C, 플라보노이드, 페놀화합물, 당도 및 산도 등의 기능성 화합물을 분석하였다. 과실의 외관 품질인 과고, 과폭 및 과중은 A처리가 다른 처리에 비하여 가장 높았다. 특히 과중은 A, B, C, D, E처리 순으로 무거웠다. 식물체의 초장이나 엽수는 유의적 차이가 없었으나 줄기 직경과 엽면적은 A처리가 유의하게 컸다. 수박 과육 내플라보노이드, 항산화 활성 및 산도는 처리 간에 유의적 차이가 없었다. 한편 당도는 A, B 및 D 처리에서 유의하게 높게 나타났다. 또한 페놀화합물 함량은 A처리가 가장 높았다. 이상의 결과로 보아 대과의 수박 생산을 위해서는 A처리, 소과의 수박 생산에는 D와 E의 처리가 유리할 것으로 판단되었다.
        4,000원
        16.
        2014.02 구독 인증기관 무료, 개인회원 유료
        The performance of spray vale using three nozzles has been investigated experimentally. Experimental apparatus is composed of the steam line and water line. Capacity 20kW electric heaters were used to produce the 1l0oC steam. The 300C water was produced using a water bath. Water outlet temperature is measured for each model to evaluate the performance of the nozzle.
        4,000원
        17.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, cycle performance analysis of two-stage compression and two-stage expansion refrigeration system using Natural refrigerants is presented to offer the basic design data for the operating parameters of the system. Alternative natural refrigerant R290(Propane), R600(Butane), R717(Ammonia), R1270(Propylene) for freon refrigerant R22 were used working fluids in this study. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, and mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of two-stage compression and two-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ration of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and two-stage expansion refrigeration system using alternative nreon refrigerants have an effect on COP of this system.
        4,000원
        18.
        2013.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        현재 분리막 여과 공정은 정수처리에서 많은 관심을 받고 있다. 하지만, 분리막의 효율적인 운영을 위하여 '혼화/응집(/침전)' 등의 전처리 시설 설치로 인한 부지면적 및 비용증가와 5~10%의 배출수 문제가 추가적으로 발생한다. 그래서 본 연구에서는 전처리 공정 없이 지표수(한강)에 대하여 가압식 PVDF 분리막[(주)에코니티]으로 운전하여 성능을 검토하였으며 그 결과 1년 동안 화학적 세정 없이 여과 flux가 1~2.4 m/d (at 25℃)로 운전되었고, 유입원수의 탁도와 상관없이 분리막 처리수의 탁도는 0.05 NTU 이하로 안정되게 유지되었다. 또한, 회수율 제고를 위하여 1개월 동안 가압식 배출수(역세수 + 배수)를 침지식 PE 분리막[(주)에코니티]으로 연계하여 2단 막여과 운영을 한 결과 전체 공정 회수율을 99.5%까지 증가시킬 수 있었다.
        4,000원
        19.
        2012.09 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Particle collection efficiency and air cleaning capacity were tested for the two-stage electrostatic precipitator for use in indoor air cleaning systems. A wire-plate type ionizer was used as a particle charger and a dielectric film consisted of polypropylene (or polyethylene) coated metals and zigzagged metal electrodes was used as a particle collector in the electrostatic precipitator. Both particle collection efficiency and air cleaning capacity increased as increasing the applied voltage on the charger and the collector, and furthermore, as increasing the collector film width (i.e. collection area). Air cleaning capacities estimated by the product of particle collection efficiency and air flow rate were quite well consistent with the experimental ones with a proportional constant of 0.964. Ozone concentrations emitted from the charger at the applied voltages of 5.0 and 5.2 kV were less than 0.05 ppm, indoor ozone standards of UL 867-2002, KS C 9314 and SPS-KACA002-132. For the air flow rate of 11.7 m3/min, the applied floor area of 48.2 m2 could be obtained when 5.2 kV and 6.0 kV were applied on the ionizer and the collector, respectively and the collector of two 15 mm polyethylene dielectric films was used.
        4,600원
        20.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 프리지아 구근수확 시기를 달리하였을 때 2단구가 형성되지 않으면서 구근을 장기간 보관할 수 있는 온도 및 기간 등 저장방법을 찾고자 실시하였다. 프리지아 구근 수확시기는 절화 직후와 절화 후 45일 2처리로 실시하였다. 구근 저장온도는 5, 10, 15, 20, 30οC, 저장기간은 20, 40, 60, 80, 100일 등 각각 5 처리를 두었다. 2단구는 구근의 생장점 부위에 싹이 맹아하지 않고 작은 자구가 발생하는 형태적인 변화를 말하는 것으로 저장 중 온도가 맞지 않을 경우 나타 난다. 시험결과를 보면 절화 후 바로 구근을 수확 할 경우 이본느 품종은 30οC로 80일 이상, 샤이니골드는 20οC에서 100일 이상, 30οC는 60일 이상 정식 전에 저장하면 정식 이후 2단구가 회피되었다. 절화 45일 후에 구근을 수확 할 경우에는 이본느와 샤이니골드 두 품종 모두 정식 전에 20οC에서 100일 이상, 30οC 는 40일 이상 보관하면 정식 이후 2단구 발생이 억제 되었다. 절화 직후 구근을 수확한 처리에서 구근을 30οC로 100일 저장 후 정식한 결과 샤이니골드와 이 본느 품종의 맹아소요일수는 각각 34일과 31일로 나 타나 한달 이상소요 되었지만, 절화 45일 후에 수확한 구근은 같은 처리에서 두 품종 모두 맹아소요일수가 7 일로 나타나 절화 45일 후에 수확한 구근의 휴면이 빨리 타파되는 것으로 밝혀졌다.
        4,000원
        1 2 3