High-rise buildings are equipped with TMD (Tuned Mass Damper), a vibration control device that ensure the stability and usability of the building. In this study, the seismic response control performance was evaluated by selecting the design variables of the TMD based on the installation location of the twisted irregular building. To this end, we selected analysis models of 60, 80, and 100 floors with a twist angle of 1 degree per floor, and performed time history analysis by applying historical seismic loads and resonant harmonic loads. The total mass ratio of TMDs was set to 1.0%, and the distributed installation locations of TMDs were selected through mode analysis. The analysis results showed that the top-floor displacement responses of all analysis models increased, but the maximum story drift ratio decreased. In order to secure the seismic response control performance by distributed installation of TMDs in twisted irregular buildings, it is judged that the mass ratio distribution of TMDs will act as a key variable.
Dynamic responses of nuclear power plant structure subjected to earthquake loads should be carefully investigated for safety. Because nuclear power plant structure are usually constructed by material of reinforced concrete, the aging deterioration of R.C. have no small effect on structural behavior of nuclear power plant structure. Therefore, aging deterioration of R.C. nuclear power plant structure should be considered for exact prediction of seismic responses of the structure. In this study, a machine learning model for seismic response prediction of nuclear power plant structure was developed by considering aging deterioration. The OPR-1000 was selected as an example structure for numerical simulation. The OPR-1000 was originally designated as the Korean Standard Nuclear Power Plant (KSNP), and was re-designated as the OPR-1000 in 2005 for foreign sales. 500 artificial ground motions were generated based on site characteristics of Korea. Elastic modulus, damping ratio, poisson’s ratio and density were selected to consider material property variation due to aging deterioration. Six machine learning algorithms such as, Decision Tree (DT), Random Forest (RF), Support Vector Machine (SVM), K-Nearest Neighbor (KNN), Artificial Neural Networks (ANN), eXtreme Gradient Boosting (XGBoost), were used t o construct seispic response prediction model. 13 intensity measures and 4 material properties were used input parameters of the training database. Performance evaluation was performed using metrics like root mean square error, mean square error, mean absolute error, and coefficient of determination. The optimization of hyperparameters was achieved through k-fold cross-validation and grid search techniques. The analysis results show that neural networks present good prediction performance considering aging deterioration.
Phayathonzu temple in Myanmar was made of masonry bricks, and so it was vulnerable to lateral load such as earthquake. Especially, it has many difficulties in structural modeling and dynamic analysis because the discontinuous characteristics of masonry structure should be considered. So, it is necessary to provide the seismic performance evaluation technology through the inelastic dynamic modeling and analysis under earthquake loads for the safety security of masonry brick temple. Therefore, this study analyzes the seismic behavior characteristics and evaluates the seismic performance for the 479 structure with many cracks and deformations. Through the evaluation results, we found out the structural weak parts on earthquake loads.
본 연구에서는 수소 자원의 활용도가 높아짐에 따라 수소 저장 용기의 내진 성능을 평가하기 위해 수소 저장 시설을 방문하여 현장 조사를 수행하였다. 외관 조사 중, 수조 저장 용기의 지지부에서 부식이 진행됨을 확인하였고, 이에 대한 대책안 으로 내부식성 재료인 CFRP로 대체하여 성능을 평가, 검증하였다. 이를 위해 현장 조사 결과를 바탕으로 상용 유한요소해석 프 로그램인 ABAQUS를 사용하였으며, 해석 결과 CFRP로 제작된 수소 저장 용기의 지지부는 강재 대비 약 12배 이상 뛰어난 성 능을 보였다. Hashin Damage Criteria를 기반으로 CFRP 지지부의 안전성 검토를 수행한 결과 최대 손상 지수가 0.065로 확인되 었다. 기초부 콘크리트의 경우, 쪼갬 및 휨 인장 응력에 대한 안전성을 검토하였으며, 허용 강도 대비 7~36%의 안전도를 보였 다. 이를 근거로 CFRP를 수소 저장 용기의 지지부에 적용하는 것은 합리적이며, 뛰어난 경제성을 보인다. 다만, 이러한 결과는 수치 해석에 의하므로 실규모 지진동 모사 시험을 통해 해석 모델의 신뢰성을 보충할 필요가 있다.
This paper describes the seismic performance evaluation of reinforced concrete bridge columns under constant and varying axial forces. For this purpose, nine identical circular reinforced concrete columns were designed seismically by KIBSE (2021) and KCI (2021). A comparison of lateral forces with theoretical strength shows that the safety factor for columns under varying axial forces is less marginal than those under constant axial forces. In addition, columns under varying axial forces exhibit significant fluctuations in the hysteretic response due to continuously varying axial forces. This is particularly prominent when many varying axial force cycles within a specific lateral loading cycle increase. Moreover, the displacement ductility of columns under varying axial forces does not meet the code-specified required ductility in the range of varying axial forces. All varying axial forces affect columns' strength, stiffness, and displacement ductility. Therefore, axial force variation needs to be considered in the lateral strength evaluation of reinforced concrete bridge columns.
For fast-built and safe precast concrete (PC) construction, the dry mechanical splicing method is a critical technique that enables a self-sustaining system (SSS) during construction with no temporary support and minimizes onsite jobs. However, due to limited experimental evidence, traditional wet splicing methods are still dominantly adopted in the domestic precast industry. For PC beam-column connections, the current design code requires achieving emulative connection performances and corresponding structural integrity to be comparable with typical reinforced concrete (RC) systems with monolithic connections. To this end, this study conducted the standard material tests on mechanical splices to check their satisfactory performance as the Type 2 mechanical splice specified in the ACI 318 code. Two PC beam-column connection specimens with dry mechanical splices and an RC control specimen as the special moment frame were subsequently fabricated and tested under lateral reversed cyclic loadings. Test results showed that the seismic performances of all the PC specimens were fully comparable to the RC specimen in terms of strength, stiffness, energy dissipation, drift capacity, and failure mode, and their hysteresis responses showed a mitigated pinching effect compared to the control RC specimen. The seismic performances of the PC and RC specimens were evaluated quantitatively based on the ACI 374 report, and it appeared that all the test specimens fully satisfied the seismic performance criteria as a code-compliant special moment frame system.
현장에 적용하는 콘크리트 강도가 증가함에 따라 초고성능 콘크리트의 적용 분야가 넓어지고 있다. 초고성능 콘크리 트에는 강섬유를 일반적으로 사용하고 있지만, 이를 대체하기 위해 다양한 섬유를 연구에 적용하고 있다. 대표적으로 슈퍼섬유 라고 알려진 아라미드 섬유가 있다. 본 연구에서는 초고성능 콘크리트의 특성이 구조물 보수보강 및 내진보강에 적용하기에 적 합하다고 판단하여, 슈퍼섬유 중 하나인 파라아리미드 섬유와 조합한 복합섬유를 혼입한 초고성능 콘크리트를 보-기둥 접합부에 내진보강재로 활용하여 특성을 분석하였다. 초고성능 콘크리트의 내진보강 효과를 확인하였으며 내진상세를 적용한 실험체와 유사한 거동을 확인하였다. 초고성능 콘크리트의 높은 강도로 인해 기존 콘크리트가 파괴되는 양상이 나타나 초고성능 콘크리 트의 보수보강 효과를 모두 발휘하지 못하고 있어 추가 연구를 통해 최적의 보강단면을 설정한다면 내진보강재료로 활용할 수 있을 것으로 판단된다.
강진에 대한 다양한 비선형 거동을 하는 부재요소들로 이루어진 교량시스템의 현재까지의 일반적인 지진취약도 평가방법은 부재- 수준에서 평가하는 것이다. 본 연구의 목적 부재-수준의 지진취약도 평가결과로부터 구조시스템을 대표하는 시스템-수준의 지진취 약도 평가방법을 개발하는 것이다. 교량의 지진 거동을 일반적으로 교축방향과 교축직각방향으로 구분하기 때문에 본 연구에서도 시 스템-수준 지진취약도를 두 방향에 대하여 구분해 평가하였다. 길이 방향에 대한 부재-수준의 지진취약도평가는 교각, 교량받침, 충 돌, 교대, 낙교에 대하여 수행하였다. 교축직각 방향에 대해서는 충돌, 교대, 낙교의 손상이 영향을 주지 않으므로 부재-수준의 지진취 약도평가는 교각과 교량받침에 대하여만 수행하였다. 다양한 구조부재의 비선형모델을 이용한 지진해석은 OpenSEES 프로그램을 사용하여 수행하였다. 시스템-수준의 지진취약도는 부재-수준 사이의 손상이 직렬연결이라고 가정하고 평가하였다. 교각의 손상이 다른 부재-수준의 손상보다 시스템-수준의 지진취약도에 지배적인 영향을 주는 것을 알 수 있었다. 다시 말하면 가장 취약한 부재-수 준의 지진취약도가 시스템-수준의 지진취약도에 가장 지배적인 영향을 주는 것을 의미한다.
2017년 지진에서 다수의 필로티형 건물에 손상이 발생함에 따라 필로티형 건물의 내진성능 평가의 중요성이 대두되 었다. BST면의 활용과 검증은 여러 연구자들에 의해 이미 수행되었다. BST면을 활용하여 필로티형 건물의 횡저항성능을 파악 할 수 있다면, 필로티형 건물의 초기 계획 또는 내진보강 계획 시 횡력저항 시스템을 배치하는데 도움이 될 것이다. 이에 본 연 구에서는 필로티형 건물에 BST면의 적용가능성을 파악한 후, 실제 지진피해를 입은 필로티형 건물의 보강 전과 후의 BST면을 비교하여 횡저항성능을 파악하였다. 그 결과 손상된 필로티형 건물을 보강함에 있어 보강된 평면의 BST면과 밑면 전단력에 대 한 비틀림 모멘트의 비를 기울기로 하는 거동 분석을 통해 필로티형 건물의 횡저항성능을 파악함으로써 보다 효과적인 보강방 안을 제시할 수 있었다.
This study presents a dry precast concrete (PC) beam-column connection, and its target seismic performance level is set to be emulative to the reinforced concrete (RC) intermediate moment resisting frame system specified in ACI 318 and ASCE 7. The key features include self-sustaining ability during construction with the dry mechanical splicing method, enabling emulative connection performances and better constructability. Test specimens with code-compliant seismic details were fabricated and tested under reversed cyclic loading, which included a PC beam-column connection specimen with dry connections and an RC control specimen. The test results showed that all the specimens failed in a similar failure mode due to plastic deformations in beam members, while the hysteretic response curve of the PC specimen showed comparable and emulative performances compared to the RC specimen. Seismic performance evaluation was quantitatively addressed, and on this basis, it confirmed that the presented system can fully satisfy all the required performance for the intermediate RC moment resisting frame.
In this paper, seismic performance evaluation was carried out for eight circular reinforced concrete columns designed seismically by KRTA[1]and KCI[8]. Primary design parameters for such columns included many longitudinal reinforcements, yield strength of reinforcements, the vertical spacing of spirals, aspect ratio, and axial force ratio. The test results showed that all the columns exhibited stable hysteretic and inelastic responses. Based on the test results, drift ratios corresponding to each damage state, such as initial yielding, initial cover spalling, initial core concrete crushing, buckling, and fracture of longitudinal reinforcement and final spalled region, were evaluated. Then, those ratios were compared with widely accepted damage limit states. The comparison revealed that the existing damage states were considerably conservative. This implies that additional research is required for the damage limit states of such columns designed seismically by current Korean design codes.
강진은 적절한 내진 설계 기술이 적용되지 않으면 건물 붕괴로 인하여 극심한 피해가 발생할 수 있다. 이를 해결할 수 있는 면진 기술은 구조물과 지반 사이에 베어링 장치를 적용하여 지진 에너지를 흡수하고 건물에 전달되는 진동을 감쇠한 다. 본 연구는 고무 마찰 베어링 장치의 구조물 적용성을 검증하고 지진으로부터 안전성을 확보하기 위하여 고무 마찰 베어링 프레임 구조물에 대한 수치해석을 수행하였다. 수치해석 결과로써 최대 지붕 가속도와 총 밑면 전단력이 감소되어 내진 성능을 확인하였다. 또한, 최대 층간 변위 및 최대 잔류 층간 변위에 대한 분석 결과로 프레임 구조물을 경제적 복구 수준의 결과를 도 출하여 고무 마찰 베어링 장치의 우수한 내진 성능을 확인하였다.
Tuned mass damper (TMD) is widely used to reduce dynamic responses of structures subjected to earthquake loads. A smart tuned mass damper (STMD) was proposed to increase control performance of a traditional passive TMD. A lot of research was conducted to investigate the control performance of a STMD based on analytical method. Experimental study of evaluation of control performance of a STMD was not widely conducted to date. Therefore, seismic response reduction capacity of a STMD was experimentally investigated in this study. For this purpose, a STMD was manufactured using an MR (magnetorheological) damper. A simple structure presenting dynamic characteristics of spacial roof structure was made as a test structure. A STMD was made to control vertical responses of the test structure. Two artificial ground motions and a resonance harmonic load were selected as experimental seismic excitations. Shaking table test was conducted to evaluate control performance of a STMD. Control algorithms are one of main factors affect control performance of a STMD. In this study, a groundhook algorithm that is a traditional semi-active control algorithm was selected. And fuzzy logic controller (FLC) was used to control a STMD. The FLC was optimized by multi-objective genetic algorithm. The experimental results presented that the TMD can effectively reduce seismic responses of the example structures subjected to various excitations. It was also experimentally shown that the STMD can more effectively reduce seismic responses of the example structures conpared to the passive TMD.
New buildings have been designed using different seismic design standards that have been revised. However, the seismic performance of existing buildings is evaluated through the same performance evaluation guidelines. Existing buildings may not satisfy the performance targets suggested in the current guidelines, but there are practical limitations to discriminating the existing buildings with poor seismic performance through a full investigation. In this regard, to classify buildings with poor seismic performance according to the applied standard, this study aimed to evaluate performance-based investigation of the seismic design proposals of buildings with different design standards. The target buildings were set as RC ordinary moment frames for office occupancy. Changes in seismic design criteria by period were analyzed, and the design spectrum changes of reinforced concrete ordinary moment resisting frames were compared to analyze the seismic load acting on the building during design. The seismic design plan was derived through structural analysis of the target model, compared the member force and cross-sectional performance, and a preliminary evaluation of the seismic performance was performed to analyze the performance level through DCR. As a result of the seismic performance analysis through the derived design, the reinforced concrete ordinary moment frame design based on AIK 2000 has an insufficient seismic performance level, so buildings built before 2005 are likely to need seismic reinforcement.
The precast-buckling restrained braces(PC-BRB) reinforced with engineering plastics that can compensate for the disadvantages in the manufacturing process of the existing buckling restrained brace. In this study, to examine the applicability of PC-BRB to actual structures, example structures similar to school facilities were selected and the reinforcement effect was analyzed analytically according to the damping design procedure of PC-BRB. Load-displacement curve through the incremental loading test appeared similar to the bilinear curve. Applying test result, Analytical model of PC-BRB model was constructed and applied to the example structure. As a result of the analysis, the PC-BRB showed stable hysteresis behavior without lowering the strength, and the inter story drift ratio and the shear force were reduced due to the damping effect. In addition, the reduction ratio of the shear force was similar to the reduction ratio assumed when designing the damping device.
연층을 가지는 건축물들의 피해사례가 관측됨에 따라 기존 건축물 내진성능평가시 수직비정형의 고려가 중요해졌다. 하지만 기존 방법은 수직비정형을 충분히 반영하기 어렵기 때문에 수직비정형을 가지는 건축물에 대해 내진성능을 과소 혹은 과대평가할 여지가 있다. 본 연구는 강성기반 연층비(Soft Story Ratio, SSR)를 이용해 수직비정형 건축물의 내진성능평가 기법을 개발하는데 목적이 있다. SSR은 변위에 대한 요구량과 능력의 비율을 나타내고, 강성차이에 의한 수직비정형을 고려하여 건축물의 변위집중 비율을 의미하는 파라미터다. 1층 기둥을 변수로 하는 필로티 건축물 네 개를 대상으로 개발한 내진성능평가 기법을 기존의 내진성능평가 기법과 비교하였다. 기존 기법은 수직비정형이 극대화되는 모델에 대해 내진성능을 과대평가하는 경우가 발생하였다. 반면 제안된 기법은 모든 모델에 대해서 상세평가의 결과와 동일했다. 따라서 제안하는 내진성능평가 기법은 수직비정형이 극대화되는 필로티 건축물에서 기존의 방법보다 정밀하게 내진성능평가 결과를 제공할 수 있다고 사료된다.
내진설계규정이 정립되기 전에 시공된 콘크리트 교각의 경우 횡철근을 겹침이음하거나 최소한의 배근으로 최적화를 유도하였다. 따라서 지진하중 발생 시 지진에너지를 소산할 수 있는 에너지 감쇠의 효과가 기존 교각들에는 미흡한 실정이다. 본 논문은 반복하중을 받는 원형콘크리트 교각 외부에 강판, GFRP, CFRP 보강을 적용한 경우, 교각의 지진대응 성능 향상도를 정량적으로 평가하였다. 범용유한요소해석프로그램인 ABAQUS의 다양한 3차원 요소를 적용하여 교각 구조물을 모델링하였으며,하중은 교각 상부에 횡방향 동적하중과 교각 전체 자중이 고려되었다. 하중-변위 곡선, 응력-변형률 곡선, 연성도, 에너지 흡수 능력(연성도), 손상도를 고려하여 보강에 따른 교각의 내진성능 향상도를 비교분석하였다. 비보강 콘크리트 교각의 경우 연성도는 78%로 취성파괴 구조물이었으나, 강판보강의 경우 91.0%, GFRP보강의 경우 91.9%, CFRP보강의 경우 92.0%이다. 세 가지 보강의 종류를 비교한 결과 강도, 연성도, 손상도 모두에 있어서 CFRP보강의 경우가 가장 큰 증진 효과를 보이고 있다.
최근 국내 지진 발생 빈도 및 강도가 증가함에 따라 지진 발생시 건물 주요 구조부에 대해서는 내진설계 및 내진 구조기술이 적용되어 지진에 대비하고 있으나, 비구조 요소인 커튼월과 창호에 대해서는 내진에 대비한 충분한 고려가 이루어지지 못하고 있다. 본 연구에서는 동적 내진성능 기준을 만족할 수 있는 커튼월을 개발하기 위해 동적 지진파 인가 시 커튼월이 파손 없이 대응 가능한 지진 변위 대응 패스너를 적용하여 동적 내진성능실험을 통해 이를 규명하고자 한다. 동적 내진성능실험을 수행한 결과, 본 연구에서 제시한 3축 이동형 패스너를 활용한 커튼월이 실제 지진파에 대응 가능하다는 것을 확인할 수 있었다.
A new lighting support structure composing of two-way wires and pulley, a pulley-type wireway system, was developed to improve the seismic performance of a ceiling type lighting equipment. This study verifies the seismic performance of the pulley-type wireway system using a numerical approach. A theoretical model fitted to the physical features of the newly-developed system was proposed, and it was utilized to compute a frictional coefficient between the wire and pulley sections under tension forces. The frictional coefficient was implemented to a finite element model representing the pulley-type wireway system. Using the numerical model, the seismic responses of the pulley-type wireway system were compared to those of the existing lighting support structure, a one-way wire system. The addition of the pulley component resulted in the increasement of energy absorption capacity as well as friction effect and showed in significant reduction in maximum displacement and oscillation after the peak responses. Thus, the newly-developed wireway system can minimize earthquake-induced vibration and damage on electric equipment.