검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 93

        1.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to experimentally analyze the seismic performance of beam-column specimens with vertical irregular, which were reinforced with RHS (Replaceable steel haunch system). a steel haunch system. To evaluate the seismic performance of the RHS, three specimens were manufactured and subjected to cycle loading tests. Retrofitted specimens have different beam-upper column stiffness ratio as a variable. The stiffness ratio of beam-upper column were considered to be 1.2 and 0.84. As a result of the test, the specimen reinforced with RHS showed improved maximum load and effective stiffness, and energy dissipation capacity compared to the non-retrofitted specimen with same beam-upper column stiffness ratio. The specimen with 0.84 beam-upper column stiffness ratio showed improved performance than the specimen with 12.
        4,000원
        2.
        2023.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The column-tree type steel beam-column connections are commonly used in East Asian countries, including Korea. The welding detail between the stub beam and column is similar to the WUF-W connection; thus, it can be expected to have sufficient seismic performance. However, previous experimental studies indicate that premature slip occurs at the friction joints between the stub and link beams. In this study, for the accurate seismic performance evaluation of column-tree type moment connections, a moment-slip model was proposed by investigating the previous test results. As a result, it was found that the initial slip occurred at about 25% of the design slip moment strength, and the amount of slip was about 0.15%. Also, by comparing the analysis results from models with and without the slip element, the influence of slip on the performance of overall beam-column connections was examined. As the panel zone became weaker, the contribution of slip on overall deformation became greater, and the shear demand for the panel zone was reduced.
        4,000원
        3.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The effect of the laser beam diameter on the microstructure and hardness of 17-4 PH stainless steel manufactured via the directed energy deposition process is investigated. The pore size and area fraction are much lower using a laser beam diameter of 1.0 mm compared with those observed using a laser beam diameter of 1.8 mm. Additionally, using a relatively larger beam diameter results in pores in the form of incomplete melting. Martensite and retained austenite are observed under both conditions. A smaller width of the weld track and overlapping area are observed in the sample fabricated with a 1.0 mm beam diameter. This difference appears to be mainly caused by the energy density based on the variation in the beam diameter. The sample prepared with a beam diameter of 1.0 mm had a higher hardness near the substrate than that prepared with a 1.8 mm beam diameter, which may be influenced by the degree of melt mixing between the 17-4 PH metal powder and carbon steel substrate.
        4,000원
        6.
        2020.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 H-Beam 부재에 TRM(Total Reinforced Member)공법의 적용을 통한 부재의 구조성능개선에 대하여 분석하였다. TRM공법은 가교의 성능개선을 위해 적용되는 여러 공법 중 프리스트레스 도입을 통해서 H-Beam 부재의 구조성능을 개선하는 공법이다. 우선 본 연구에서는 해석적인 시뮬레이션을 통해서 TRM공법의 적용 가능성을 확인하였다. 1차적으로 수치 해석을 통해서 프리스트레스 도입을 위한 선행하중을 결정하고, 순수 H-Beam 부재와 L형 강재가 용접된 부재 그리고 TRM공법이 적용된 3가지의 부재에 대한 구조성능 변화를 해석을 통해서 확인하였다. 그리고 해석적인 결과의 검증 및 공법의 현장적용 가능성을 평가하기 위하여 순수 H-Beam 부재와 TRM공법이 적용된 2가지의 부재에 대한 3점 굽힘 시험을 수행하였다. 실험을 통하여 TRM공법이 적용된 부재에서 순수 H-Beam 부재대비 하부 플랜지의 발생응력 및 최대처짐이 각각 20.60%, 16.87% 감소 하는 결과를 확인하였다.
        4,000원
        7.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        U-flanged truss beam is composed of u-shaped upper steel flange, lower steel plate of 8mm or more thickness, and connecting lattice bars. Upper flange and lower plate are connected by the diagonal lattice bars welded on the upper and lower sides. In this study, the details of delayed buckling of lattice members were developed through reinforcement of the end section, in order to improve structural capacity of U-flanged Truss Steel Beam. To verify the effects of these details, the simple beam experiment was conducted. The maximum capacity of all the specimens were determined by the buckling of the lattice. The vertical reinforced details of the ends with steel plates, rather than the details reinforced with steel bars, are confirmed to be a valid method for enhancing the structural capacity of the U-flanged Truss beam. In addition, U-flanged Truss Steel Beam with reinforced endings with steel plates can exhibit sufficient capacity of the lattice buckling by the formulae according to Korean Building Code (KBC, 2016) and Eurocode 3.
        4,000원
        8.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper discusses the influence of transverse reinforcement spacing and support width of concrete wide beam on shear performance. In order to evaluate the shear performance, a total of thirteen specimens were constructed and tested. The transverse reinforcement spacing, the number of legs and support width were considered as variables. From the test results, the shear strength equation of concrete wide beam is proposed for prediction of shear strength of concrete wide beam to consider the transverse reinforcement spacing and support width. It is shown that the proposed equation is able to predict shear strength reasonably well for concrete wide beam.
        4,000원
        9.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        U-flanged truss beam is composed of u-shaped upper steel flange, lower steel plate of 8mm or more thickness, and connecting lattice bars. Upper flange and lower plate are connected by the diagonal lattice bars welded on the upper and lower sides. In this study the structural experiments on the U-flanged truss beams with various shapes of upper flange were performed, and the flexural and shear capacities of U-flanged truss beam in the construction stage were evaluated. The principal test parameters were the shape of upper flange and the alignment space of diagonal lattice bars. In all the test specimens, the peak loads were determined by the buckling of lattice bar regardless of the upper flange shape. The test results have shown that the buckling of lattice bar is very important design factor and there is no need to reinforce the basic u-shaped upper flange. However, the early lattice buckling occurred in the truss beam with upper steel bars because of the insufficient strength and stiffness of upper chord, and the reinforcement in the upper chord is necessary. The formulae of Eurocode 3 (2005) have presented more exact evaluations of lattice buckling load than those of KBC 2016.
        4,000원
        11.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As an alternative to coupling beam in shear wall system, application of the damper which can dissipate energy is increasing. In this study, lintel beam type steel damper which is simple to construct and change depending on design load was proposed. Cyclic loading test was conducted to compare reinforced concrete coupling beam and lintel beam type steel damper. The test results showed that lintel beam type steel damper has higher initial stiffness and energy dissipation capacity than reinforced concrete coupling beam.
        4,000원
        12.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When reinforcing an existing reinforced concrete beam-column building with a precast concrete panel, special connection between the PC member and the RC member is required to solve the time dependent deformation of the RC member and to receive the large shear forces. The aim of this study is to obtain the shear strength of upper connection between the existing RC beam-column and infilled PC wall panels in experimentally and theoretically. Thus, the static shear loading tests were conducted on the 6 specimens with the plate connection. Shear failure was resulted from the weakest portion of interior PC panel, exterior RC, and the connection, when the PC portion which located at the center of specimen was pulled upward from the bottom. T he experimental result was compared with analytical result from ACI 318M-14 Chapter 17 for the shear strength of post-installed anchor and PCI Handbook 7th edition 6.8 Structural Steel Corbel (PCI Design Handbook 7th edition, 2010) for the strength of cast-in H-beam. The analytical and experimental results show final failure at the same location. The failure loading of experiment showed larger than average 6% to that of the analysis.
        4,500원
        13.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents the resizing method of columns and beams that considers column-to-beam strength ratios to simultaneously control the initial stiffness and ductility of steel moment frames. The proposed method minimizes the top-floor displacement of a structure while satisfying the constraint conditions with respect to the total structural weight and column-to-beam strength ratios. The design variable considered in this method is the sectional area of structural members, and the sequential quadratic programming(SQP) technique is used to obtain optimal results from the problem formulation. The unit load method is applied to determine the displacement participation factor of each member for the top floor lateral displacement; based on this, the sectional area of each member undergoes a resizing process to minimize the top-floor lateral displacement. Resizing members by using the displacement participation factor of each member leads to increasing the initial stiffness of the structure. Additionally, the proposed method enables the ductility control of a structure by adjusting the column-to-beam strength ratio. The applicability of the proposed optimal drift design method is validated by applying it to the steel moment frame example. As a result, it is confirmed that the initial stiffness and ductility could be controlled by the proposed method without the repetitive structural analysis and the increment of structural weights.
        4,000원
        14.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 철골모멘트골조의 보-힌지 붕괴모드를 유도하는 최적 내진설계기법을 제안한다. 이는 유전자알고리즘을 사용하며, 기둥의 소성힌지 발생을 억제하는 제약조건을 설정하여 보-힌지 붕괴모드를 유도한다. 제안하는 기법은 구조물량를 최소화하고 에너지소산능력을 최대화하는 목적함수를 사용한다. 제안하는 기법은 9층 철골모멘트골조 예제 적용을 통해 검증한다. 예제 적용을 통해 철골모멘트골조의 보-힌지 붕괴모드를 유도하기 위해 요구되는 기둥-보 강도비를 평가한다. 패널존에 대한 3가지 모델링 기법을 각각 적용하여 모델링 조건에 따른 휨강도비 영향이 추가적으로 검토된다.
        4,000원
        15.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 유공형 강판의 횡방향 보강간격에 따른 넓은 보의 전단성능을 실험적으로 평가하기 위하여 횡방향 전단보강 간격과 넓은 보의 유효깊이를 변수로 고려하였다. 시험체는 총 8개로 유공형 강판으로 전단보강한 시험체가 5개, 무보강 시험체가 3개이다. 균열 및 파괴유형, 변형률과 하중-변위 곡선을 분석하였다. 유공형 전단보강재의 전단강도 기여분을 분석하고, 횡방향 전단보강의 최대간격을 제안하였다. 횡방향 전단보강 개수가 2개인 시험체에 비해 3개인 시험체에서 전단강도가 크게 나타났으며 유효깊이가 증가할수록 전단강도가 크게 나타났다.
        4,000원
        16.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper shows the simplified equation to predict the ultimate moment capacity and corresponding rod stress in reinforced concrete beam with external post-tensioning rods. Because the stress of external post-tensioning rod depends on the beam deflection, the previous analytical model for post-tensioned beams requires a tedious iteration process. Also, the stress equations in ACI code or other researchers’ models are suitable only for internal tendons in concrete beams. In this study, given the lack of analytical approaches to predict the nominal stress of the external unbonded rod, a simple and robust equation has been proposed for externally post-tensioned concrete beams. It is concluded that the proposed equation predicted the stress of external steel rods in post-tensioned concrete beams reasonably well.
        4,000원
        17.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        건물의 경우, 용도 변경에 따른 중력하중 변화, 시공 단계에 따라 중력하중 변화 등이 구조물 시스템에 영향을 미친다. 따라서, 본 연구에서는 시스템 식별 변수 설정에 있어 기존에 강성만을 변수로 설정한 방법에 추가적으로 질량을 변수로 설정하여 시스템을 식별하는 기법을 제안한다. 계측한 동특성과 FE모델에서 추출한 동특성 간의 차이를 최소화하여 변수를 탐색하게 된다. 최소화 기법으로 변형 유전 알고리즘을 적용하였다. 보다 전역적 해탐색을 위해 변형 유전 알고리즘은 더 넓은해 탐색 공간에서 해를 찾는다. 철골 보 구조물의 시뮬레이션을 통해 본 연구가 제시한 기법을 검증하였고 변형 유전 알고리즘과 기존의 단순 유전 알고리즘의 성능을 비교하였다. 또한, 강성 식별만을 수행한 기존 연구의 방법과 본 연구가 제시한 기법간의 차이를 비교하였다.
        4,000원
        18.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In recent years, the construction of high-rise buildings are promoted. According to these, there are many needs about new technologies to strengthen the building performance and high-strength steel is regarded as one of these for promoting building performance. In Korea, high-strength steels which stress are over 600MPa are on market and in aborad, super high-strength steels over 1000MPa are developing and they expected to promote the building performance. But there are still doubts about applying high-strength steel members because of size effect and worry of brittle fracture. In this reports, we propose results of performance and analysis tests for use with general steel. We propose the characteristic of high-strength steels first and next the results of performance test to show they satisfy the performance that designers expect. And last, we compare the results of test and analysis for acquire the alanysis reliability in non-linear analysis with high-strength steels.
        4,000원
        19.
        2012.04 구독 인증기관·개인회원 무료
        The purpose of this study is to analyze flexural strengthening capacity of steel structures using composite materials through the experiment. Until now, A Flexural capacity reinforcing method of steel beams has been used by steel plate appending. The conventional method due to the increase in weight of the reinforcement reduces operation efficiency and welding process cause discomfort which due to the interference of other process. But, the specific gravity of AFRP(Aramid Fiber Reinforced Plastic) strip used as reinforcement in this study is less approximately 20% than steel(SS400) and tensile strength of AFRP is s higher approximately 4 times than steel(SS400). In overseas, CFRP(Carbon Fiber Reinforced Plastic) was used with civil steel structures but, it is difficult to find examples of applying AFRP. In this paper, A experiments were carried out as a variable(development length and thickness of AFRP and CFRP) for flexural strengthening of steel structures.
        20.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recent cross-country competition and Chinese steel industry because of the emerging steel industry in Korea is a very difficult situation. Therefore, the steel industry in order to overcome this difficult market environment, the quality, cost competitiveness, enhance customer service levels and enhance international competitiveness through is needed. In this study, the purpose of strengthening the competitiveness of steel companies in order and hit the recovery of raw materials have been developed to optimize the model, developed before and after the results were analyzed. In addition, when applied to other products in order to minimize risk and optimize cutting trial stage of development details of the model is presented in detail. Therefore, the developed model was applied to order the recovery of raw materials hits and significantly improved production planning time has been shortened dramatically. In the present study the contents of other products when properly applied and the competitiveness of companies to improve customer service levels are expected to be helpful.
        4,200원
        1 2 3 4 5