        41.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the need for asset management(AM) plan introduction to reduce increasing O&M cost with aging water facilities is on the rise. Therefore, asset inventory classification is necessary as the first step for AM plan construction. In this study, all assets of YW water treatment plant(WTP) were classified as 5 steps. In addition, specific code name was given to each asset which can increase compatibility in constructing the AM programs among WTPs. In the future, codes for attribute and status of asset will be allocated, which can facilitate proper AM operation.
        4,000원
        42.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A fire sprinkler system is very important to extinguish fire in the building. The sprinkler system initiates sprinkler discharge if the detection system identifies a developing fire and opens the pre-action valve. However, pre-action fire sprinkler systems mainly installed in the underground parking lot at the apartment complex do not properly operate at fire if the connection type of fire sprinkler systems does not properly installed and operated. This study identified the relationship between fire dispersion & damage and the connection type of water supply in the sprinkler system from many fire cases at the apartment complex in South Korea. In addition, this study also identified the water supply differences and characteristics between South Korea and foreign countries. The main purpose of this study is also to improve the water connection types in the sprinkler system that can reduce the potential failures of pre-action valve operation through electrical signal system. The study also suggests the improvement plan for water connection types in pre-action fire sprinkler system that can minimize potential failure of pre-action fire sprinkler system. The suggestions for revising the fire safe standard in South Korea includes letting the water supply pipe of sprinkler system water inlet connect to the second side of pre-action valve and the water flow device that can minimize potential failure of sprinkler system.
        4,000원
        43.
        2015.11 구독 인증기관·개인회원 무료
        지하수를 식수원으로 활용하고 있는 대부분의 소규모 마을상수도 시설에서 방사성물질 발현에 대한 문제가 지속적으로 재기됨에 따라, 2015년 수질감시기준에 우라늄 항목이 추가되었다. 효과적인 우라늄 처리를 위하여, 마을상수도 시설에 NF 및 RO를 이용한 처리공정의 적용이 증가하고 있으나, 적용된 분리막의 효율적인 관리방법이 미흡한 현실이다. 전문적인 운영관리인원이 부족한 현실에서 안정적인 RO공정의 운영을 위한 방안으로 분리막의 세척방안 마련이 필요하다. 이를 위하여 본 연구에서는 RO공정을 마을상수도에 도입시키고 운영하며, 발생되는 RO 분리막 오염의 효과적인 제어방법을 도출코자 하였다. 효율적인 세척방법으로 산/염기의 순차적 세척방법이 도출되었으며, 약 93%의 분리막 세척효과를 확인하였다.
        44.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Korea's modern waterworks began with construction of DDukdo water treatment plant in 1908 and has been growing rapidly along with the country’s economic development. As a result, water supply rates have reached 98.5% based on 2013. Despite multilateral efforts for high-quality water supply, such as introduction of advanced water treatment process, expansion of waterworks infrastructure and so on, distrust for drinking tap water has been continuing and domestic consumption rate of tap water is in around 5% level and extremely poor comparing to advanced countries such as the United States(56%), Japan(52%), etc. Recently, the water management has been facing the new phase due to water environmental degradation caused by climate change, aging facilities, etc. Therefore, K-water has converted water management paradigm from the "clean and safe water" to the "healthy water“ and been pushing the Smart Water City(SWC) Pilot Project in order to develop and spread new water supply models for consumers to believe and drink tap water through systematic water quality and quantity management combining ICT in the whole water supply process. The SWC pilot projects in Pa-ju city and Go-ryeong county were an opportunity to check the likelihood of the "smart water management" as the answer to future water management. It is needed to examine the necessity of smart water management introduction and nationwide SWC expansion in order to improve water welfare for people and resolve domestic & foreign water problems.
        4,000원
        45.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The function failure of present major facilities is likely to lead to failure of related systems and/or whole facilities, increasing the necessity for protection of infrastructures, main structures, and major industrial facilities. In addition, safe and efficient management for urban infrastructure (waterworks and sewerage facilities, electricity, telecommunications, roads, etc) installed in the basement or on large cities grounds at various public areas is required. Recently in response to this demand, efforts for vitalizing asset management are being made such as enacting related laws and developing asset management system in the U.S., Australia, Europe and other advanced countries with the concept for a new maintenance. In our county, identifying maintenance system problems such as aging and rapid increasing of existing infrastructures and decision-making about updating maintenance is required for systematic and organizational maintenance. In this study, by comparing and observing the LOS(Level of Service) of each countries’ waterworks and risk-based LOS, we suggest the direction of future urban water infrastructure management systems for more effective management.
        4,500원
        46.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Optimal design of the water supply pipe network aims to minimize construction cost while satisfying the required hydraulic constraints such as the minimum and maximum pressures, and velocity. Since considering one single design factor (i.e., cost) is very vulnerable for including future conditions and cannot satisfy operator’s needs, various design factors should be considered. Hence, this study presents three kinds of design factors (i.e., minimizing construction cost, maximizing reliability, and surplus head) to perform multi-objective optimization design. Harmony Search (HS) Algorithm is used as an optimization technique. As well-known benchmark networks, Hanoi network and Gyeonggi-do P city real world network are used to verify the applicability of the proposed model. In addition, the proposed multi-objective model is also applied to a real water distribution networks and the optimization results were statistically analyzed. The results of the optimal design for the benchmark and real networks indicated much better performance compared to those of existing designs and the other approach (i.e., Genetic Algorithm) in terms of cost and reliability, cost, and surplus head. As a result, this study is expected to contribute for the efficient design of water distribution networks.
        4,200원
        47.
        2015.05 구독 인증기관·개인회원 무료
        우리나라는 물 자원이 풍부하지는 않으나 수처리 시설 및 기술의 발달, 정부의 먹는 물 공급정책에 따라 상수도 보급률이 매우 높다. 그러나 2013년 상수도 통계에 따라면 아직도 농․어촌을 중심으로 상수도 보급률은 66 %수준에 그치고 있고 이런 지역은 지하수 등 자연으로부터 공급되는 물을 사용하고 있다. 지하수의 경우 매우 유용하고 우수한 수자원이지만 지질의 영향이나 농축산업의 영향으로 인해 우라늄과 같은 자연방사성 물질, 질산성 질소 등의 물질에 오염되어 있다. 이에 오염된 물질에 대한 적정한 제거기술을 도입하여 상수도 미보급 지역의 안전한 먹는 물 공급을 위한 정부 차원의 시범연구와 지원사업이 진행되고 있다. 본 발표에서는 정부와 기업이 함께 진행하고 있는 안전한 먹는 물 공급을 위한 시범 사업을 소개하고자 한다.
        48.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To improve stability of the water resources that were seriously affected by climate change and various environmental effects and to supply the clean water always, continuous efforts are essential. Provision of measures with respect of hardware is basically essential to improve the water resources stability due to the topographic characteristic in Korea. However, building a new dam becomes gradually very difficult because of a hardship in selecting right places, opposition forces such as environment and local residents, negative publicity for large civil engineering projects, and so on. The present study, therefore, proposes the Blue dam as an alternative for securing the water resources of a new concept considering domestic conditions. To evaluate the effect of the Blue dam, the Hec-ResSim model is used and the probabilistic discharge flow rate is applied. As a result, when Dam Yeongcheon is applied as a study area, securing water resources of 14 million tons are predicted be secured and the flood control of 15.4 million tons is expected, in comparison with operation of the existing dam only. Consequently, Blue dams are supposed to carry out the function of securing water resources, controling flood, maintaining eco-environmental instream flow, generating hydroelectric power, and providing spaces for recreational activities.
        4,000원
        49.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        It is expected that the temperature in Pyeongyang will be similar to that (16.6℃) in Seogwipo in the late 21st century, and most of South Korea will enter the subtropical climate due to climate change. Change in the precipitation pattern like the range of fluctuation caused by climate change will lead to expanded uncertainty in securing reliable water supply, along with a serious impact on demands for living and industrial water due to change in the volume and period of river outflow. As industrial water for production activities is estimated based on the contract quantity, it is difficult to apply rationalization of water usage and incentives in water recycling. Therefore many companies are making efforts in complying with the effluent standard while spending few resources on such rationalization and recycling. This study researched water risk management over 115 Korean companies by 28 questions in 4 categories. Through the research, this study aims to understand water risk management levels and seek response plans.
        5,500원
        50.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, a System Dynamics(SD) computer simulation model has been developed to assess the effects of developing and providing an alternate water source. A water service index was also developed to estimate the level of overall customer satisfaction on water supply service. Data from the Busan water supply service and the Korea Development Institute regarding the Nak Dong river bank storage development were utilized during the modeling processes. Some important indicators of the system under study were analyzed by the simulations of development of the alternate water source for Busan. The developed SD model and the water service index can be further utilized as a tool that can assess the extent and timing of an additional service improvement project.
        4,000원
        51.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 관로내의 민물담치 및 유생의 생물량을 효 과적 조절하기 위해서 수행되었다. 부착방지 및 생물량 조절방법은 기존에 사용되고 있는 염소처리법이 추천될 수 있었다. 민물담치의 산란기간은 수온 16~17􀆆C 범위 에 해당하는 5월~11월 초순 동안으로 추정되었다. 유생 을 조절하기 위해서는 이 기간에 염소처리를 하는 것이 적합하나, 기존에 부착하고 있는 치패와 성패가 동시에 고려되어야 하므로 연중 지속적으로 이루어져야 할 것 으로 판단된다. 산란이 시작되는 시기에서 각이 형성되 기 전인 유생기와 성패의 생물량 조절을 위해 0.5~1.0 ppm 범위의 염소농도로 처리하는 것이 적합하다. 민물 담치의 부착증식을 경감 또는 해결하기 위해서는 우선 적으로 국내 실정에 적합한 기술의 선정이 시급하였다. 또한 수온과 유생의 모니터링이 지속적으로 이루어져야 할 것으로 판단되며 유생 모니터링 방법 구축 및 염소 처리 효과분석에 대한 사후모니터링이 필요한 것으로 사료되어진다.
        4,000원
        52.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For introducing the groundwater quality assessment using background concentration of groundwater, several methods had been studied to estimate the background concentration of groundwater and to suggest the background concentration of study area. Some methods such as Box whisker plot, Percentile and Cumulative probability distribution had been adopted to estimate background concentration, and it was evaluated that the Cumulative probability distribution method presents more reasonable background concentration because it can consider the data distribution. So we estimated the background concentration of study area using cumulative probability distribution method. We suggested the background concentration for each hydrogeology respectively in case hydrogeological water quality similarity is very low.
        4,600원
        53.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Decentralized water supply systems, treating the water in users’vicinity, cutting down the distribution system, utilizing the alternative water resources(rainwater harvesting, water reclamation and reuse and so on.) and saving energy and other resources, could be categorized into POU(Point-Of-Use), POE(Point-Of-Entry) and community small scale system. From the literature review, we could thought that decentralized water supply system and hybrid system(integrating centralized and decentralized water supply system within urban water management) might have strengthening comparative advantages to centralized system with respect to: (1) water security, (2) sustainability, (3) economical affordability. Even though it is difficult to derive and quantify direct benefit advantages from decentralized and hybrid system in comparison with centralized system, (1) operational cost reduction, (2) assurance for safe and stability water supply and (3) greenhouse gas reduction can be expected from successful establishment of the former.
        4,600원
        54.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The water distribution system should be invariably operated on continuous pattern for 24 hours a day. Occasionally, it is not practically possible to operate for 24 hours due to water shortage or financial constraints. Therefore an intermittent water supply is unavoidable in water shortage area and developing countries.But the intermittent water supply can introduce large pressure forces and rapid fluid accelerations into a water supply network. These disturbances may result in new pipe failure, leakage and secondary contamination.This paper proposed an improvement methodology to prevent the disturbances by intermittent water supply. For the study, the hydraulic variation of intermittent flow in water distribution system was measured and analyzed in the field by comparing with simulation of hydraulic model. Installations of control valves such as, pressure reducing and sustaining and air valves were employed for pressure and flow control. The effectiveness of the methods are presented by comparing hydraulic conditions before and after introducing the proposed solutions.
        4,200원
        55.
        2013.06 구독 인증기관 무료, 개인회원 유료
        This study analyzed agricultural water distribution systems for the utilization of water demand-oriented water supply systems. Three major TM/TC(telemeter/telecontrol) districts of agricultural water management were selected for analyzing the characteristics of the water distribution systems. In addition, the characteristics of the water supply systems for general water supply zones based on irrigation facilities were also investigated, along with the case of special water management during the drought season. As a result, high annual and monthly variations were observed for the water supply facilities, including the reservoirs and pumping stations. In particular, these variations were more obvious during the drought season, depending on the type of facility. The operations of the pumping stations and weirs were more sensitive to the stream levels than the reservoirs, and the smaller reservoirs were influenced more than the larger reservoirs. Therefore, a water-demand-oriented water supply system should consider the existing general practices of water management in the agricultural sector, and focus on achieving a laborsaving system rather than water conservation in the case of reservoirs. Equal water distribution from the start to the end point of irrigation channels could be an effective solution for managing pumping stations.
        4,000원
        57.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The flow rate analysis for sanitary fixtures has been studied to determine the water supply piping system and size. The study has been carried out to analyze for a various water supply pressure and piping size theoretically. Also, the study has been carried out to analyze for a various water supply piping system experimentally. The water supply pressure is varied from 0.01MPa to 0.07MPa, and the piping size is varied from 6mm to 15mm. The water supply piping systems are one-to-one, all-loop-type, and bathroom-loop-type water supply piping system. The results indicate that the piping size is able to supply water fully in case of smaller than 15mm if the water supply pressure keep an necessary minimum pressure. And the gap of flow rate is very little for the various water supply piping systems
        4,000원
        59.
        2008.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 시험은 펄라이트 배지에서 적산일사량에 따른 급액이 장미 'Cardinal'의 생육에 미치는 영향을 고찰하기 위하여 수행하였다. 배지내의 pH는 6.0에서 6.1사이로 안정적이었고 EC는 급액보다는 배액에서 높게 나타났는데 후기로 갈수록 높아지는 경향이었다. 무기 성분은 비순환식 C. Sonneveld처방 기준으로 보면 인산과 칼리, 마그네슘이 집적됨을 알 수 있었는데, 특히 칼리와 마그네슘은 각각 기준량 195ppm, 18보다 집적됨을 알 수 있었다. 배지의 배액율은 전체적으로는 일사량이 많으면 높아지는 경향이었다. 장미 수액은 오전 9시 경부터 12시까지 흐름이 있었는데, 10시 30분에서 11시 사이에 273g·hr-1이었는데 일사량에 비례하여 수액흐름이 증가하지는 않았다. 양액소모량은 250W·hr-1에서는 50m1구에서 212.8ml로 많았는데 수량도 154.6본/10a로 많아 양액소모량이 수량에 영향을 미치는 것을 알 수 있었다. 펄라이트 배지에서 양액공급량은 11월부터 3월에 200W·hr-1에서 50ml를 1일 6~10회 급액하고 일사량이 많을 때는 250W·hr-1에서 30ml를 1일 22~30회 급액하는 것이 좋을 것으로 생각된다.
        4,000원