Due to seismically deficient details, existing reinforced concrete structures have low lateral resistance capacities. Since these building structures suffer an increase in axial loads to the main structural element due to the green retrofit (e.g., energy equipment/device, roof garden) for CO2 reduction and vertical extension, building capacities are reduced. This paper proposes a machine-learning-based methodology for allowable ranges of axial loading ratio to reinforced concrete columns using simple structural details. The methodology consists of a two-step procedure: (1) a machine-learning-based failure detection model and (2) column damage limits proposed by previous researchers. To demonstrate this proposed method, the existing building structure built in the 1990s was selected, and the allowable range for the target structure was computed for exterior and interior columns.
In South Korea, over 400,000 Non-building Structures are inadequately managed and exposed to potential risks due to insufficient inspection systems, leading to an increase in accidents and significant losses of life and property. Therefore, it is crucial for users to conduct proactive self-inspections to identify and mitigate potential hazards. This study reclassified Non-building Structures into four main categories by analyzing their structural characteristics and associated risks through statistical analysis. Among these, retaining walls, which account for the largest proportion, were systematically analyzed to identify common damage patterns. Based on this analysis, self-inspection checklists were developed for both non-experts and experts. The proposed process involves an initial visual inspection using a simple non-expert checklist, followed by a more detailed expert-level inspection if any anomalies are detected. The reliability of this process was validated through approximately 120 validation processes.
국내 지진 발생의 빈도는 점차 증가하는 추세에 있으며, 포항지진(5.4 규모)은 진앙지와 주민 거주지가 가까워 피해 가 심각했는데 건물의 외장재가 떨어져 차량 등에 2차 피해가 발생하여 건물 외장재 안전에 대한 우려가 커지고 있는 실정이 다. 따라서 본 연구에서는 비구조 요소 중 커튼월의 동적 내진성능평가 규격에 대한 세계 각 국의 규준을 고찰하고 이 중에서 가장 널리 통용되는 AAMA501. 6-18에 따라 그 동적 내진성능을 평가하고자 한다. 또한, 본 연구에서 수행한 3축 동적 지진파 대응 가능 커튼월 시스템 실험을 통해 지진에 대한 2차 피해 방지를 위한 내진 커튼월 설계시공지침 개발에 기초적 자료로 제 공하고자 한다.
최근 현장작업을 최소화할 수 있는 PC(Precast Concrete) 건축공법의 적용이 급속하게 활성화되고 있다. 그러나 PC 공법은 시공 중, 특히 부재간 일체화 이전에 구조적 성능을 발휘하기 어렵고 완공 후에도 접합부의 일체성을 확보하기 어려워 연쇄붕괴에 취약하다. PC 건축물에서는 다양한 PC 부재간 접합 상세가 존재하며, 국내외 구조/시공 상세가 현격히 다르다. 그러나 국내 PC 시스템의 시스템 과 상세 특성을 반영한 연쇄붕괴에 대한 연구는 매우 미비하다. 따라서, 본 연구에서는 국내에서 주로 사용하는 PC 구조시스템과 접 합부 구조/시공 상세를 조사 분석하였다. 이를 기반으로 국내에서 사용되는 전형적인 PC 시스템의 유형을 설정하고 상기 PC 시스템 의 연쇄붕괴방지성능을 평가하기 위하여 비선형 유한요소해석을 수행하였다. 해석결과를 바탕으로 국내에서 주로 사용된 PC 구조시 스템의 연쇄붕괴방지 성능을 평가하고 구조설계시 고려사항을 제안하였다.
여러 센서를 이용한 구조물의 구조 응답을 모니터링하는 사례가 증가하고 있다. 그러나 비용과 관리 문제로 인해 제한된 센서만이 구조물에 설치되어 일부의 구조 응답만을 수집하는 경우가 대부분이다. 이는 구조물의 전체 거동을 분석하는데 장애요소로 작용하게 된다. 따라서 제한된 센서를 이용해 센서가 설치되지 않은 위치에서의 응답을 신뢰할 수 있는 수준으로 예측하는 기술이 필요하다. 본 연구에서는 제한된 정보를 이용해 저층 건물 구조물의 지진 응답을 예측하는 해석적 연구를 수행한다. 활용 가능한 응답 정보는 1층과 최상층의 가속도 응답만을 사용할 수 있다고 가정한다. 두 정보를 이용하면 구조물의 1차 고유진동수를 얻을 수 있다. 1층 가속도 정보는 구조물의 가력 정보로 활용한다. 최상층의 가속도이력응답에 대한 오차와 대상 구조물의 1차 고유진동수 오차를 최소화하는 구조물의 질량과 강성 정보를 유전자알고리즘을 이용해 예측하는 기법을 제시한다. 제약조건은 고려하지 않는다. 탐색공간을 의미하는 설계변수의 범위를 결정하기 위해 인공신경망 기반의 파라미터 예측기법을 제시한다. 또한 유전자알고리즘을 통해 얻게 되는 해를 개선시키기 위해 앞서 언급한 인공신경망을 활용한다. 제시한 기법을 검증하기 위해 5층 구조물 예제를 사용한다.
The damage detection method using the extended Kalman filter(EKF) technique has been continuously used since EKF can estimation the responses of the damaged building structure and the stiffness of the structure. However, in the use of EKF, the requirement of setting the initial paramters P, Q, and R has caused the divergence and instability of the state vector, and various researches have been conducted to determine theses parameters. In this paper, adaptive extended Kalman filter(AEKF) method is proposed to solve the problem of setting the values of P, Q, and R, which are important parameters determining the convergence performance of the EKF state vector. By using the AEKF method proposed in this study, the P, Q, and R parameters are updated every k steps. The proposed algorithm is applied for the estimation of stiffness and the damage detection of 3-DOF problem. Based of the verification, it can be found that the selection process for the values of P, Q, and R can improve the convergence performance of EKF.
This study examines the seismic failure of RC low-rise building structures having irregularities at the ground story during the 15 November 2017 Pohang, Korea, earthquake, Mw = 5.4, which is the second strongest since the government began monitoring them in 1978 in South Korea. Some 2,000 private houses were damaged or destroyed in this earthquake. Particularly, serious damage to the piloti story of RC low-rise residential building structures of fewer than five stories was observed within 3 km of the epicenter with brittle shear failure of columns and walls due to severe torsional behavior. Buildings below six stories constructed before 2005 did not have to comply with seismic design requirements, so confinement detailing of columns and walls also led to inadequate performance. However, some buildings constructed after 2005 were damaged at the flexible side of the piloti story due to the high torsional irregularity. Based on these results, this study focuses on the problems of the seismic torsion design approach in current building codes.
In this paper, it is covered in detail the process of generating structural alternatives with geometry change and its optimization by StrAuto. The main roof structure of the Exhibition Center is modelled parametrically and the optimal alt is derived by observing volume changes according to geometry change of main roof truss. Existing studies performed optimization process through sections and properties due to the limitations of shape change, but this study have meaning of performing the optimization with geometry changes which is the most critical skills of StrAuto. By the process of securing a sufficient margin by geometry changes and reducing volume with the optimization of sections, despite of a partial optimization of large space structure, it could be reduced by 11.7% of the total volume.
For earthquake loss estimation of building structures in Gangnam-Gu district in Seoul, three scenario earthquakes were selected by comparison of the response spectra of these scenario earthquakes with the design spectrum in Korean Building Code (KBC 2009), and then direct losses of the building structures in the Gangnam-Gu district under each scenario earthquake are estimated. The following conclusions are drawn from the results of damage and loss in the second scenario earthquake, which has a magnitude = 6.5 and epicentral distance =15 km: (1) The ratio of building stocks undergoing the extensive and complete damage level is 40.0% of the total. (2) The amount of direct economic losses appears approximately 19 trillion won, which is 1.2% of the national GDP of Korea. (3) About 25% of high-rise (over 10-story) RC building wall structures, were inflicted with the damage exceeding moderate level, when compared to 60% of low-rise building structures. (4) From the economical view point, the main loss, approximately 50%, was caused by the damage in the high-rise RC wall building structures.
본 연구에서는 풍하중을 받는 건물에 설치된 다중거동 복합 감쇠장치(MHD)의 성능을 평가하고, MHD 예비설계 절차를 제안하였다. MHD에 의해 증가된 등가감쇠비와 그에 따른 건축구조기준에 근거한 응답저감계수를 예상한 후, 풍하중 스펙트럼에 의해 생성된 풍하중을 사용하여 20층 철골구조물에 대한 시간이력 해석을 수행하였다. 해석결과를 통해 얻어진 층변위 및 층간변위 평균 응답 감소율은 각각 0.585 및 0.525로, 이는 제안한 예비설계과정에서 추정된 응답감소계수 0.6과 거의 동일한 수치임을 확인하였다. 이로부터 제안된 방법을 사용하여 MHD의 제어효과를 효과적으로 평가할 수 있음을 확인하였다.
Observations of the damages to high-rise reinforced concrete (RC) wall building structures caused by by recent earthquakes in Chile (Mw 8.8, February 2010) and New Zealand (February 2011, ML 6.3) have generally exceeded expectations. Firstly, this study estimated the seismic damage levels of 15-story RC box-type wall building structures using the analytical models calibrated by the results of a shaking table test on a 1:5 scale 10-story RC box-type wall building model. Then, the seismic fragility analysis of the prototype model was conducted by using the SAC/FEMA method and the incremental dynamic analysis (IDA). To compensate for the uncertainties and variability of ground motion and its impacts on the prototype model, in the SAC/FEMA method, a total of 61 ground motion records were selected from 20 earthquakes, with a magnitude ranging from 5.9 to 8.8 and an epicentral distance ranging from 5 to 105km. In the IDA, a total of 11 ground motion records were used based on the uniform hazard response spectrum representing a return period of 2,475 years. As a result, the probabilities that the limits of the serviceability, damage control, and collapse prevention would be exceeded were as follows: from the SAC/FEMA method: 79%, 0.3%, and 0%, respectively; and from the IDA: 57%, 1.7%, and 0%, respectively.
일반적으로 건축물의 구조해석과 설계에 있어 작업효율을 확보하기 위하여 상부구조물과 하부구조물을 별도로 모델링하여 해석 및 설계를 진행하는 분리해석 방법을 사용한다. 하지만, 상기 분리해석을 사용할 경우, 상부구조물의 고정지점과 변형된 기초구조물과는 실제 연결된 지점에서 변위차가 발생하여 구조해석의 기본요건인 변형적합성 조건을 만족하지 못하게 되고 상부구조-하부구조의 상호작용을 고려하지 못하기 때문에 실제와는 다른 구조해석 및 설계결과를 초래할 수 있다. 본 연구에서는 초고층 철골구조물을 대상으로 구조물의 부등침하 등에 큰 영향을 미치는 상재(常載)하중에 대한 분리해석과 일체해석의 해석결과 차이를 비교 분석하였다. 분석결과에 따르면 분리해석방법을 사용할 경우, 상부구조물의 구조해석에 있어 기초의 변형을 고려하지 못하기 때문에 부재력을 과소평가할 수 있고 이로인해 비안전측 설계결과를 가지고 올 수 있다. 하부 기초구조물을 분리해석으로 해석하였을 경우, 상부구조물의 강성을 고려하지 못하기 때문에 기초의 부등침하 과대평가, 부재력의 과대/과소 평가를 초래할 수 있어 비경제적이고 불안전한 설계결과를 가져올 수 있다. 특히, 기초의 변형이 상부구조물에 큰 영향을 미칠 수 있는 건축구조물, 지반의 강성이 작아서 기초에 큰 변형이 예상되는 건축물, 지반조건이 불균질하여 부등침하가 예상되는 건축구조물 등에는 분리해석을 지양해야 할 것이다.
현재 국내에서 생산되는 구조용 강재의 강도는 크게 5가지로 구분할 수 있다. 경제적인 구조설계를 하기 위하여 적절한 강도의 선정이 우선적으로 요구되는데 현재는 이와 관련된 기존 자료가 충분치 않은 상태이다. 최근, 국내에서 항복강도가 650MPa인 고강도 강재가 개발되어 구조용 강재의 강도 범위가 더 커졌기 때문에 부재 종류별 강재의 선택에 따른 경제성의 차이도 더 커졌을 것으로 예상된다. 본 논문에서는 경제적인 구조설계에 도움이 되도록, 항복강도 235MPa, 325MPa 및 650MPa 강재를 다양한 구조부재에 적용함으로서, 고강도 강재 적용에 따른 부재 종류별 경제성을 분석하였다.
An application of the EQS (Eradi Quake System) bearings to a short period building structure and the structure earthquake responses according to the design parameters of the EQS are studied by the ICT Center case study. The features of the EQS application to seismic isolated building structures are investigated, and the design procedure to determine the yield load and the secondary stiffness of the EQS is also studied. A computational analysis is performed to confirm the applicability of the EQS to the building structure and the earthquake responses according to the design parameters. The ICT Center in Indonesia is adopted as an application case of the EQS. The application of the EQS is found to extend the fundamental period of the ICT Center. Three types of EQS with different yield loads and secondary stiffness are designed and applied in the earthquake response analyses. The analysis results show the response of the structure with respect to the design parameters and which type of EQS is suitable for the ICT Center.
Recent projects for transferring Public Office buildings and estimation of appropriate construction expense are highly important for both government and construction firms. Moreover, estimation and management of construction expense can be regarded as extremely important duties for effective execution of a national budget as nation’s finance is invested in the Public office building projects progressed by the government. To progress one project for Public office building, not only the organization demanding the project but also an investment screening organization, a budget-managing organization, a feasibility assessment institution and many other related organizations participate in the project and a lot of decisions arisen from the project operation are made on the basis of construction expenses calculated for relevant stages. And estimation of rational construction expense is also critical for designers in order to create design within the fixed budget simultaneously with securing the quality and efficiency of structures to the maximum. Therefore this research suggested an improvement process to analyze problems in current construction expense management process and to administer the construction expenses effectively.
본 연구에서는 풍진동 제어 기술의 하나로 현재 대부분의 초고층 건축물에 적용되고 있는 아웃리거 시스템에 댐퍼를 설치한 아웃리거 댐퍼 시스템에 대하여 수치해석모델과 상용 구조해석프로그램을 사용한 모델을 사용하여 최적설계 및 변수연구를 수행하였다. 먼저 아웃리거 댐퍼의 거동 특성을 반영하도록 상태방정식을 사용한 단자유도 수치 모델을 설계하였고 상용 구조해석 프로그램을 사용해서 최적설계를 위한 다자유도모델을 설계하였다. 강성이 고려되지 않고 오직 댐퍼의 감쇠에 의한 최적 위치는 최상층인 것으로 나타났지만 중간 이상의 층에서는 댐퍼의 높이에 따른 성능 변화가 크지 않기 때문에 강성과 감쇠가 복합적으로 운동에 참여하는 실제 구조물의 경우 최적의 위치가 최상층이 아닌 다른 층에 존재한다. 아웃리거 댐퍼시스템은 기존 일반적인 아웃리거 시스템과 비교할 때 가속도 응답을 줄이는데 있어 매우 효과적인 것을 확인하였다.
In this study, a shear wall-slab damper system for seismic retrofitting of existing low-rise school buildings was proposed. The proposed system is to control the earthquake-induced vibration of the existing building structures using the energy dissipation effect of hysteretic damper inserted between the extended shear wall and existing moment frame. The numerical analyses were performed to investigate the vibration control efficiency of the shear wall-slab damper system and to identify the range of optimal yielding strength of the slab damper. In addition, variation of shear force of the extended shear wall with regard to the yield strength of the dampers in a range from 10 to 100 percent of the maximum base shear force of the retrofitted structure was investigated. The numerical analyses results showed that the maximum displacement of the structures with the slab damper whose yield strength is equal to 20 percent of the maximum base shear. On top of that, the slab damper system reduced the shear force of the shear wall by about 50 percent in comparison with the existing frame-shear wall system with rigid diaphragm slabs.