검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 39

        21.
        2004.08 구독 인증기관 무료, 개인회원 유료
        Earthquake resistant design was introduced to Korea in 1988 for tall buildings, in 1992 for highway bridges and even earlier than that for nuclear power plants. The apartments designed by large unit housing planning was constructed by tunnel form method for the construction convenient in 1980. As a results, many structures without any seismic resistance capacity were built during the 80’s. In this paper, to improve the seismic capacity in wall-slab joint, experiments which improve and retrofit a seismic capacity by steel reinforcing, unequal angle bracing, carbon sheet attachment are carried out. These methods also are economic and simple in mitigating seismic hazard, improving earthquake-resistance performance, and reducing the risk level of building occupants. Consequently these methods were confirmed its effectiveness in improving the seismic performance were confirmed its effectiveness.
        4,000원
        22.
        2001.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        면진기술은 주로 저층 구조물의 내진설계에서 적용되는 방법으로 건물과 기초사이에 면진장치를 설치하여 상부로 전달되는 지진하중을 효과적으로 감소시킨다. 그러나 이 방법은 중.고층 구조물에 그대로 적용하기에는 여러 가지 기술적 문제가 따르므로, 구보물의 중간층 일부를 분리시켜 상부로 전달되는 지진력을 감소시킬 수 있을 것이다. 본 노문에서는 저층 뿐만 아니라, 중.고층 정형구조물의 주상복합건물과 같은 비정형 구조물에 대하여 구조물의 중간층 일부를 비선형 면진장치로 면진시키고 그 효과를 분석하였다. 이러한 중간층 면진 구조물의 경우, 고정기초 구조물에 비하여 적은 층간변위나 층전단력이 발생하였으며, 특히 주상복합건물에서 상당한 효과를 볼 수 있었다.
        4,000원
        23.
        2019.11 KCI 등재 서비스 종료(열람 제한)
        본 논문은 비내진 상세를 갖는 철근콘크리트 골조 및 필로티 건물의 보강방법으로 높은 연성을 갖는 ECC를 적용한 PC 벽판을 내진 보강요소로 사용하고자 하였다. PC 벽판의 형상비 및 설치 위치를 변수로 RC 골조에 대한 반복가력실험을 실시하여 내진성능을 평가하였다. 실험결과 PC 벽판을 보강함에 따라 기존 RC 골조의 내력 증진, 강도저하 방지, 강성증진 및 에너지 소산능력 향상에 효과적인 것으로 나타났다. 실험결과를 근거로 비내진 상세를 갖는 골조의 강도 증진을 위하여 ECC PC 벽판을 골조의 중앙에 설치하고 연성증진을 위하여 세장한 벽판을 골조의 양측면에서 설치할 것을 제안한다.
        24.
        2019.01 KCI 등재 서비스 종료(열람 제한)
        세계적으로 지진과 같은 자연재해로 인한 대규모 피해가 증가하고 있다. 다양한 연구를 통하여 건물에 대한 내진성능은 확보되었으나, 비구조요소의 내진성능 확보 미흡으로 인하여 인명 피해 및 경제적 손실이 발생하고 있다. 비구조요소는 구조물에 설치되는 위치가 다양하고, 구조물의 위치에 따라 발생하는 진동특성이 다르므로 구조물의 위치별 응답스펙트럼이 필요하다. 또한 구조물의 형식과 구조물이 설치되는 위치에 따라 구조물에 발생하는 응답스펙트럼이 다르게 발생한다. 따라서 응답스펙트럼의 선정이 중요하므로 비구조요소에 작용하는 응답스펙트럼을 도출할 수 있는 명확한 방법이 필요하다. 본 논문에서는 응답스펙트럼을 도출하는 방법을 제안하였으며, 제안한 방법으로 국내에서 발생 가능한 지반응답스펙트럼과 구조시스템을 선정하여 구조해석을 수행하였다. 또한, 간단한 수식으로 응답스펙트럼을 도출하는 방법을 제안함으로서, 비구조요소의 내진시험에 필요한 응답스펙트럼을 생성할 수 있도록 하였다.
        25.
        2018.01 KCI 등재 서비스 종료(열람 제한)
        2016년 경주지진 이후로 국내에서도 본격적으로 건축물의 지진대책 강구가 시급한 시점에서 국내에 널리 보급되어 있는 R/C 건축 물의 효율적인 내진성능 평가 및 내진보강을 포함한 내진대책을 위한 기초적인 자료를 얻고자, 2016년 경주지진에서 지진피해를 받은 R/C 저 층 학교건축물(M학교)을 대상으로 지진피해도구분판정법을 이용하여 잔존내진성능과 지진피해정도를 평가함과 동시에, 부재수준의 비선형 동적해석을 수행하여 지진피해정도와의 상관관계를 검토하였다. 지진피해도구분판정에 의한 손상도-I로 분류된 기둥은 2개, 손상도-Ⅱ가 1 개, 손상도-III으로 분류된 기둥이 3개로 각각 평가되어, 최종적으로 평가한 내진성능잔존율(R)은 88.2%로 피해분류는 소규모 피해로 판정되 었으며, 또한 비선형동적해석 결과 1층 X방향의 최대응답을 나타낸 기둥의 휨변위는 0.7 mm, 전단변위는 6 mm로 전단균열은 발생하였지만, 전단파괴는 발생하지 않았다. 경주지진에서 지진피해를 입은 M학교의 지진피해가 1층의 X방향에 집중되어 있다는 사실, 휨균열보다는 전단 균열이 발생하였다는 사실을 고려한다면 본 연구에서 수행한 비선형동적해석 결과는 2016년 경주지진에서 지진피해를 받은 M학교의 지진피 해상황을 잘 반영하고 있다고 사료되며, 국내 기존 저층 R/C 건축물의 효율적인 내진성능 평가 및 내진보강을 포함한 내진대책을 위한 기초적 인 자료로서 활용가능하다고 사료된다.
        26.
        2017.05 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 국내 비내진상세 조적채움벽 RC 골조의 동적거동 및 손상모드를 파악하기 위하여 실규모 크기의 비내진상세 RC 골 조와 조적채움벽 RC 골조를 대상으로 진동대 실험을 실시하여 응답 및 거동 특성을 비교 평가하였다. 진동대 실험 결과, 순수 RC 골조는 기둥 상하부 휨균열 및 접합부 전단균열이 심화되어 최종 파괴되었다. 조적채움벽 RC 골조의 경우 골조의 손상은 비교적 작았으며 조적벽체의 중앙 부의 슬라이딩 균열 및 대각 전단 균열 손상이 크게 발생하였다. 조적채움벽 RC 골조는 순수 RC 골조에 비하여 초기상태의 공진주기가 짧아졌 으며 최종 가진시에서 최대변위응답은 약 62% 감소하였다. 본 연구에서 적용한 조적채움벽은 비내진 상세를 가지는 RC 골조의 강성을 약 1.6 배, 최대 강도를 약 2.2배 증가시키는 데 기여하는 것으로 분석되었다.
        27.
        2017.05 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 국내 비내진상세 조적채움벽 RC 골조의 내진성능을 파악하기 위하여 실규모 크기의 비내진상세 조적채움벽 RC 골 조를 대상으로 정적실험을 실시하였으며, 기존 비내진상세 RC 골조 의 정적 실험결과와의 비교·분석을 통하여 조적채움벽체가 RC 골조의 내 진성능에 미치는 영향에 대하여 평가하였다. 실험 결과. 조적채움벽 RC 골조 실험체는 조적채움벽체에 의한 압축력으로 기둥, 보 , 접합부 등 골조 전체에 균열 등의 손상이 발생하였으며, 접합부 전단균열이 벌어지고 철근이 노출되면서 취성 파괴되었다. 한편, 조적체움벽 RC 골조 실 험체의 수평하중과 층간변형각 관계는 벽체 슬라이딩 균열, 기둥 균열 등으로 강성이 저하되었으며, 철근 항복이후 최대 내력에 도달하고 접합 부 균열의 확대, 철근 노출 등으로 내력이 최대 내력의 40% 정도로 저하되었다. 조적채움벽체로 인하여 기둥 상·하단 및 접합부에만 집중되던 손상이 기둥, 보, 접합부 등 골조 전체에 분산되어 발생하였으며, 기둥의 전단균열이 아닌 접합부의 전단균열의 확대로 최종 파괴되었다. 또한, 조적채움벽체로 인하여 RC 골조의 강성은 12.42배, 내력은 3.63배 증가한 반면에, 강성 증가에 따라 최대 내력 시의 층간변형각은 0.18배, 파괴 시의 변형은 절반 이하로 감소하였다.
        28.
        2017.04 서비스 종료(열람 제한)
        In this study, the shake table test of the damaged reinforced concrete frame was carried out and the damage and dynamic response characteristics were evaluated. The static lateral-cyclic test for the specimen was followed by the dynamic test. As a result of the shake table test, damage was concentrated on existing cracks and the maximum inter-story drift ratio was calculated as 1.94% at the final excitation step.
        29.
        2015.11 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 내진설계 이전에 지어진 학교 건물을 대상으로 내진보강효과를 알아보기 위하여 벽체로 지지되는 강재이력형 감쇠 장치를 설치하여 기존 비내진 설계된 보강 RC골조 실험결과와 비교 분석하였다. 실험결과, 비내진 설계된 실험체는 좌․우측 기둥의 상․하부에 피해가 집중되면서 급격한 강도저하와 함께 취성적인 전단파괴의 양상을 나타낸 반면, 더블 I형 감쇠장치를 보강한 실험체는 감쇠장치 보강으 로 강도 및 강성의 증가와 함께 탄소성 거동을 보이면서 에너지 흡수 능력이 큰 타원형의 이력특성을 나타내었다. 또한, 두 실험체의 강성저하 를 비교한 결과 더블 I형 감쇠장치를 보강한 실험체가 강성저하를 방지하는데도 효과적임을 알 수 있었다. 에너지소산능력도 더블 I형 감쇠장 치를 보강한 실험체가 비보강 실험체에 비해 약 3.5배의 향상된 결과를 나타내었다. 이러한 에너지소산능력의 증진은 내력과 변형 능력의 증진 에 따른 결과라고 사료된다.
        30.
        2015.10 서비스 종료(열람 제한)
        This paper describes the effect of steel frame on seismic performance of non-ductile reinforced concrete (RC) frame. To achieve the this objective, RC frames were made based on existing school building constructed in 1980s. Test results indicated that RC frame retrofitted with steel frame was improved the seismic performance than conventional RC frame.
        31.
        2015.04 서비스 종료(열람 제한)
        Recent earthquake of incidence is increasing. The purpose of this study was to investigate the strain characteristics of bare frame with non-seismic details. The experimental investigation consisted of a cyclic load tests on 1/3-scale models of one story-one bay bare reinforced concrete frame.
        32.
        2015.04 서비스 종료(열람 제한)
        In this study, Long-period component seismic wave is determined to a large damage of the non-structural material as compared to the structure damage when it is input to high-rise buildings, which allows to perform a vibration table test, was evaluated for damage or loss of the non-structural material.
        33.
        2014.10 서비스 종료(열람 제한)
        The objectives of this research are to compute performance point using capacity spectrum analysis, and to use structural damage states classification and damage state criteria through interstory drift angle presented in HAZUS. Seismic fragility curve is drawn by seismic fragility parameter and predict damage probability about non seismic reinforced concrete buildings according to building shapes.
        34.
        2014.10 서비스 종료(열람 제한)
        Estimation of damage probability of buildings under a future earthquake is an essential issue to reduce the seismic damage. In this study, capacity spectrum method is applied to develop seismic fragility curve of low-rise non seismic reinforced concrete building under peak ground acceleration.
        35.
        2013.11 KCI 등재 서비스 종료(열람 제한)
        5층 이하 비내진상세를 가지는 철근콘크리트 건축물의 지진시 긴급 위험도 평가를 위한 부재의 정량적 손상도 평가 기준을 제시하기 위하여 실대형 크기의 철근콘크리트 1층 1경간 골조 실험체의 정적실험을 실시하였다. 실험결과, 실험체는 기둥의 휨항복후 전단파괴에 의하여 파괴되었으며, 기둥과 접합부에 균열, 압괴 등의 손상이 발생한 반면, 보에는 균열 등의 손상이 거의 발생하지 않았다. 이와 같이 비내진 상세를 가지며 휨항복후 전단파괴하는 철근콘크리트 기둥의 손상도를 5단계로 분류하고 손상단계별 한계상태를 평가하기 위한 정량적 기준으로서 지진시 상대적으로 측정이 용이한 잔류 층간변형각과 잔류 균열폭을 이용하였다. 손상한계상태의 잔류 층간변형각 및 잔류 균열폭은 실험결과에 따른 손상한계상태의 최대 층간변형각과의 관계에 의하여 결정하였으며, 한계 최대 층간변형각은 실험결과에 의한 부재의 하중-변형 관계 및 손상발생 현황을 바탕으로 결정하였다. 한계 잔류 층간변형각은 해당 최대 층간변형각에 의한 잔류 층간변형각 중의 최대값 이상이 되도록 하였으며, 한계 잔류 균열폭은 해당 최대 층간변형각에 의한 잔류 전단균열폭의 최소값 및 잔류 휨균열폭의 평균값으로 결정하였다. 한편, 본 논문을 통하여 제시한 손상한계상태의 잔류 층간변형각과 잔류 균열폭은 지진으로 동일한 부재 변형이 발생할 경우 내진설계가 실시된 부재를 대상으로 하는 국외 손상도 평가 기준에 의한 값보다 작은 것으로 나타났다.
        36.
        2013.10 서비스 종료(열람 제한)
        This study carried out a series of seismic tests to elucidate the difference of movements between two buildings with or without masonry infilled wall in reinforced concrete frames which have no quake proof plan. Both of the experimental buildings showed irreversible deformity at low drift ratio of 0.6%. The strength and stiffness of the building with masonry infilled wall were higher than those of the building without masonry infilled wall, while the ductility of the former being lower than that of the latter. Thus it led to more brittle tendency of the former.
        37.
        2013.10 서비스 종료(열람 제한)
        To evaluate the aramid sheet and metallic damper strengthening effect of non-seismic detailed RC frame FE program, which is ABAQUS, analysis is used. Used material model of concrete, steel, rebar and aramid are concrete damaged plasticity model, steel plasticity model, perfectly plasticity model and linear fracture model, respectively. From step by step lateral load increment, the stress and crack distribution of frame and elements can be properly simulate by FE analysis.
        38.
        2013.10 서비스 종료(열람 제한)
        The purpose of this paper is to verify the seismic strengthening effect of R/C buildings strengthened with the Carbon Fiber Composite Cable (CFCC) In this study, a three-story R/C building that constructed in the 1980s was selected, and its seismic performance before and after strengthening was evaluated based on the nonlinear dynamic analyses of members levels. The result indicated that the seismic strengthening effect of the proposed CFCC method was verified in terms of both strength and ductility demands, compared to the building before strengthening.
        39.
        2011.02 서비스 종료(열람 제한)
        최근 세계 곳곳에서 대규모 지진이 발생하여 건축물 붕괴에 따른 피해가 속출함에 따라 지진에 대비하기 위해 기존 건축물의 내진 성능을 보강방안에 대한 관심이 높아지고 있다. 그러나 현재 우리나라의 경우, 교육생활의 터전임과 동시에 가구 재난 발생 시 지역주민들의 응급피난장소인 학교 건축물조차 내진설계가 제대로 이루어져 있지 않고 있어, 지진 발생 시 막대한 피해가 예상된다. 현 상황을 극복하기 위해 기존 노후화 학교 건축물의 내진성능을 향상시키기 위한 적절한 보강방안이 제시되어야한다. 본 논문에서는 범용해석프로그램을 통해 기존 노후화 학교 건축물에 대한 비선형정적해석에 결과에 따른 내진보강 후 비선형 시간이력해석을 실시하여 지진하중에 의한 구조물의 비선형 거동을 규명하고 내진 보강 효과를 검증하고자 한다.
        1 2