검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6,697

        2361.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: Current theories for composite structures are too difficult for design engineers for construction. The purpose of this paper is to demonstrate to the practicing engineers, how to apply the advanced composite materials theory to the road structures. METHODS: Some laminate orientations have decreasing values of D16, B16, D26 and B26 stiffnesses as the ply number increases. The plate aspect ratio considered is from 1 to 5. In order to study the effect of Mx on the equilibrium equations, two cases are considered. Mx term is considered or neglected. RESULTS: Most of the road structures have high aspect ratios, for such cases further simplification is possible by neglecting the effect of the longitudinal moment terms. CONCLUSIONS: Most of the road structures have plate aspect ratios higher than 2. It is concluded that, for all boundary conditions, neglecting the longitudinal moment(Mx) terms is acceptable if the aspect ratio (a/b) is equal to or higher than 2. This conclusion gives good guide line for design of the road structures.
        4,000원
        2364.
        2013.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        알로에의 최소공정개발 연구의 일환으로 DIS(dewatering & impregnation soaking) 공정에 미치는 온도의 효과를 조사하였다. 삼투탈수는 분자량 4000의 PEG을 삼투제로 하여 이의 40%(w/v) 용액에 두께 0.5 cm의 알로에 잎 슬라이스를 넣고 간헐적으로 교반하면서 2시간 동안 수행하였다. 서로 다른 침지온도(25-55oC)가 DIS의 성능(수분소실 및 고형분 획득)에 미치는 영향을 현미경관찰에 의한 세포조직 구조의 경시변화를 모니터링하면서 조사, 비교되었고, 동역학적으로 분석하였다. 고온(55oC) 처리에서는 저온(25 and 35oC)에서보다 더 높은 수분소실을 보였으나 세포조직의 파괴를 동반하였다. 또, 품질지표값으로서의 glucomannan 함량은 세포조직구조를 잘 유지하였던 침지온도 35oC에서 얻어졌다. 얻어진 시료의 실온건조제품을 재수화시켜 조사하고 동역학적으로 해석한 결과, 재수화 동역학은 Peleg 및 Weibull 모델로 잘 설명할 수 있었다. DIS 제품은 DIS 처리하지 않은 제품에 비해 세포구조 및 재수화성질의 향상을 주어 적정온도하에서 DIS 처리함으로써 최소공정의 알로에 제품을 얻을 수 있음을 확인하였다.
        4,000원
        2371.
        2013.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 제주도 동백동산 상록활엽수림의 식생구조 특성을 파악하기 위하여 20m×20m 조사구 20개를 설정하고 식생조사를 실시하였다. TWINSPAN과 DCA ordination, 평균상대우점치를 분석한 결과 종가시나무-구실잣밤나무-감탕나무(동백나무)군집, 종가시나무-구실잣밤나무-동백나무군집, 종가시나무-동백나무군집, 종가시나무-동백나무-곰솔군집, 곰솔-종가시나무군집 등 총 5개 군집으로 분류되었다. 동백동산 암괴기반에 분포하는 상록활엽수림 지역은 교목층에서 구실잣밤나무와 종가시나무가 우점하고 하층에 동백나무가 우점하는 식생구조이었고 일정 토심을 유지하는 지역은 교목층에서 곰솔이 우점하였다. 곰솔군집은 동백동산이 제주도기념물로 지정되기 이전 훼손된 지역 중 일부 토심이 유지되는 지역에 식재한 것으로 추정되었다. 동백동산은 구실잣밤나무와 종가시나무가 우점하는 식생과 곰솔이 우점하는 식생 모두 향후 종가시나무-동백나무 군집으로의 천이가 예상되었다. Shannon의 종다양도지수는 상록활엽수군집에서는 1.0268~1.0717이었고 곰솔군집이 1.2102로 가장 높았다. 상록활엽수 10종의 상재도가 80% 이상이었으나 향후 교목층을 형성할 수 있는 구실잣밤나무와 생달나무는 출현빈도와 우점도가 낮았다. 고령의 동백나무가 모든 조사구에서 출현했는데 과거 숲이 훼손될 시에도 신성시 여겨져 보호되어 왔기 때문으로 판단되었다. 동백동산은 기존의 제주도 상록활엽수림과는 다른 식생구조를 보여 천이방향을 예측하기 어려운 상태이었고 과거 훼손 영향으로 다른 상록활엽수림과 다른 식생구조와 천이경향을 일부 보이고 있었다. 따라서 동백동산은 지속적 관찰이 요구되며, 식생이 안정될 수 있는 기간이 흐른 뒤에 천이방향과 군집특성을 규명하여야 할 것으로 판단되었다.
        4,300원
        2372.
        2013.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 자유낙하 하는 쐐기형 구조물의 슬래밍 충격압력 및 유동특성을 알아보고자 실험을 수행하였다. 유동장의 계측은 2-프레임 그레이레벨 상호상관 PIV 기법을 이용하였으며, 자유낙하 하는 구조물의 충격압력은 압력 계측장비인 Dewetron System을 이용하였다. 모델과 자유수면간 이루는 각도는 15˚, 25˚, 35˚ 및 45˚를 적용하였으며 중량과 자유낙하의 높이에 대해서 다양성을 주어 실험하였다. 속도장은 접수보다 이수에서 빠른 유동특성을 나타냈으며, 접수에서 보다 이수에서 시간이 더 소요됨을 보였으며, 모델 하부에서의 충격압력은 모델의 45도에서 보다, 입수각이 작은 15도와 P1 지점에서 높게 나타났다.
        4,000원
        2373.
        2013.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 언어네트워크분석을 이용하여 야외지질학습에서 학생들의 퇴적암에 대한 개념 구조 변화를 알아보기 위한 것이다. 이를 위하여 고등학생 15명을 대상으로 퇴적암에 대한 정의, 분류, 생성과정 및 특징을 묻는 개방형 문항을 개발하였으며, 이 텍스트 자료를 언어네트워크분석법을 통해 분석하였다. 그 결과 첫째, 야외지질학습을 통해 학생들의 퇴적암에 대한 개념 구조는 사전에 비해 사후에 크게 확장되었다. 둘째, 학생들의 개념 구조를 구성하는 하위 클러스터는 서로 긴밀하게 연결되어 있는 '작은 세상 네트워크'를 형성하였다. 셋째, 학생들의 개념 구조의 규모는 수개월이 지난 후 감소하였지만, 하위 클러스터의 연결 상태는 그대로 유지하고 있었다.
        4,600원
        2374.
        2013.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this research, the flow and forced convective heat transfer analysis of HEV battery pack were investigated numerically regarding the different shapes of the inlet, outlet, and battery case. The velocity ,pressure, and temperature distribution of the fluid at the inlet part of the battery module were numerically calculated for the optimum design of the battery pack for three different inlet shapes of the battery module. In addition, the local battery temperature for height and width and convective heat transfer coefficient of the air inside the battery pack were numerically obtained. Ultimately, the circle shape of the inlet and outlet were determined for the energy-effective shape of the battery pack.
        4,000원
        2375.
        2013.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the vibrational characteristic of electronic solenoid structure for vehicle is analyzed by using ADAMS as commercial multi-body dynamics analysis program. This study model is made with CATIA V5R18 as 3D computer-aided design program and analyzed with rigid body mode in ADAMS. To fulfill the vibration analysis, the result value of solenoid structure is suggested.
        4,000원
        2376.
        2013.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        면진장치는 상부구조물의 지진력을 감소시키는데 크게 기여하지만, 고감쇠고무 적층받침에 사용되는 고무재료는 시간이 경과함에 따라 열화되어 상부구조물의 동특성과 기기들의 지진응답에 영향을 줄 수 있다. 따라서 면진장치의 경년열화를 고려한 구조물의 지진응답을 분석하는 연구가 필요하다. 본 연구에서는 기존 문헌을 통하여 분석된 고무의 경년열화 특성을 사용하여 면진장치를 모델링하였다. 면진된 원전의 지진응답을 평가하기 위하여 격납건물과 보조건물을 대상 구조물로 선정하고, 진동수 성분이 다양한 입력지진동을 사용하여 구조물의 고유진동수, 최대지진응답, 층응답스펙트럼을 시간의 경과에 따라 분석하였다. 해석결과에 의하면 면진장치의 경년열화에 의하여 지진응답이 소폭 증가하였으며, 면진장치가 설치된 후 20년까지 지진응답의 증가율이 크게 나타나므로 이 기간에 상세한 검사가 시행되어야 할 것이다.
        4,000원
        2377.
        2013.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 주파수 선택적 투과막(FSS)이 결합된 복합재료 구조에서 구성 재료 간의 열팽창계수 차이로 잔류응력이 발생하므로 이로 인한 층간분리나 FSS의 손상 등 구조적인 파손 가능성과 잔류응력으로 인하여 변형된 FSS가 전파투과특성에 미치는 영향에 대하여 연구하였다. FSS는 단위요소의 종류, 설계변수, 배열에 따라 전파특성이 다르게 나타나므로, PSO 알고리즘을 이용하여 다이폴이 목표주파수에서 투과특성을 갖도록 설계하고 그 설계치수를 다른 N-pole 종류 단위요소(Tripole, Cross dipole, Jerusalem cross)에 적용하여, 복합재료 구조에 발생하는 잔류응력과 그로인한 구조적 손상과 전파특성을 영향성을 관찰하고 FSS패턴과 복합재료의 적층 변화에 따라 비교하였다.
        4,000원
        2378.
        2013.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Structures in a nuclear power system are designed to be elastic even under an earthquake excitation. However a structural component such as an isolator shows inelastic behavior inherently. For the seismic assessment of nonlinear structures, response history analysis should be performed. In this study, the response of base isolation system was analyzed by response history analysis for the seismic performance assessment. Firstly, several seismic assessment criteria for a nuclear power plant structure were reviewed for the nonlinear response history analysis. Based on these criteria, the spectrum matched ground motion generation method modifying a seed earthquake ground motion time history was adjusted. Using these spectrum matched accelerograms, the distribution of displacement responses of the simplified base isolation system was evaluated. The resulting seismic responses excited by the modified ground motion time histories and the synthesized time history generated by stochastic approach were compared. And the response analysis of the base isolation system considering the different intensities in each orthogonal direction was performed.
        4,000원
        2379.
        2013.04 구독 인증기관 무료, 개인회원 유료
        4,000원
        2380.
        2013.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        An application of the EQS (Eradi Quake System) bearings to a short period building structure and the structure earthquake responses according to the design parameters of the EQS are studied by the ICT Center case study. The features of the EQS application to seismic isolated building structures are investigated, and the design procedure to determine the yield load and the secondary stiffness of the EQS is also studied. A computational analysis is performed to confirm the applicability of the EQS to the building structure and the earthquake responses according to the design parameters. The ICT Center in Indonesia is adopted as an application case of the EQS. The application of the EQS is found to extend the fundamental period of the ICT Center. Three types of EQS with different yield loads and secondary stiffness are designed and applied in the earthquake response analyses. The analysis results show the response of the structure with respect to the design parameters and which type of EQS is suitable for the ICT Center.
        4,000원