        801.
        2013.04 서비스 종료(열람 제한)
        This experimental study was performed to investigate the effect of the aspect ratios and volume contents of hooked steel fiber for flexural tensile strength of SFRC with compressive strength of 60MPa. The notched steel fiber reinforced concrete beams with different aspect ratios and fiber volume content were tested under 3-point bending. and the flexural tensile strength, and CMOD were obtained from the experimental data. The result showed that the strength and ductility of SFRC were generally increse as the content of steel fiber was incresed.
        802.
        2013.04 서비스 종료(열람 제한)
        It is reported that alkalinity of concrete decreases inter-laminar shear strength of FRP rebar. This could be more significant on thermally damaged FRP rebar. In this study, accelerated ISS test was conducted on FRP specimens previously exposed to temperature of 270℃ for 60 days. For 60 days, the ISS of thermally damaged FRP rebar was not significant
        803.
        2013.04 서비스 종료(열람 제한)
        Five specimens were planned and conducted the experimental study in order to understand flexural performance of the pre-stressing hybrid FRP panel. As the result of test, The reinforced specimen with hybrid FRP panel and the pre-stressing specimen show the structural behavior comparison with the non-reinforced specimen
        804.
        2013.04 서비스 종료(열람 제한)
        Concrete has been widely used due to its high performance per price ratio. However, its durability is highly depended on the temperature, so it requires reinforcement on concrete structures. In this study, a long-term behavior analysis was conducted on a concrete strengthened by FRP tested on the freeze-thawing time increases, freeze-thaw evaluation. The result from this study revealed that as the frequency of freeze-thaw cycle increases, the flexural strength decreases, and the reinforcement effect, in turn, decreased. On the other hand, as the frequency increases, detachment at the binding site occurred due to the decreased durability of concrete
        805.
        2013.04 서비스 종료(열람 제한)
        The research measured cracks by visualizing them through mechano- luminescence(ML) paint. By applying M-L paint on the surface of the specimen and using the 3-point bending test. Through the results of this research, we confirmed the crack propagation speed by section and the mechanical correlation such as between loads and cracks and between deflection and cracks, which means this research was quite successful in analyzing the characteristics of cracks.
        806.
        2013.04 서비스 종료(열람 제한)
        In this paper, the utilization of PZT’s dual piezoelectric effects (i.e., dynamic strain and electro-mechanical (E/M) impedance responses) for damage detection in beam-type structures are presented. In order to achieve the objective, the following approaches are implemented. First, global vibration-based and local impedance-based methods to detect the location of damage are presented. Then, the vibration-based and impedance-based damage detection methods using the dual piezoelectric responses are evaluated from experiments on a lab-scaled beam.
        807.
        2013.03 KCI 등재 서비스 종료(열람 제한)
        보 구조물의 안전성을 평가하기 위해서, 해당 부재의 구조적 상태를 보여주는 보여줄 수 있는 변형률을 기반으로 한 모니터링 시스템이 이용되고 있다. 하지만 최대 변형률과 같은 부재의 상태를 대표할 수 있는 변형률이 발생하는 정확한 위치에 센서를 설치하지 않은 한, 계측된 변형률을 토대로 합리적인 평가를 할 수 있게 하는 추가적인 프로세스가 필요하다. 이에 따라 본 연구는 변형률계에 의해 계측된 이산데이터를 이용하여 강재 보 구조물의 변형률 분포를 추정하는 기법을 제안한다. 본 기법에서는 보 구조물에 작용하는 하중을 미지의 하중으로 가정하였기 때문에, 실제 적용성을 향상 시켰다. 최종적인 변형률 분포는 회귀 분석을 통해서 함수 형태로 주어진다. 본 기법을 이용한 추정 성능을 검증하기 위해서 분포하중, 집중하중, 모멘트가 동시에 작용하는 강재 보 구조물의 휨 실험을 수행하였다. 실험을 통해 추정 변형률의 값을 직접 계측한 값과 비교해 본 결과, 임의의 위치에서도 절대 오차 2.32με 이내로 변형률을 추정할 수 있었으며, 전체 변형률 분포는 3.32% 이내의 상대오차로 얻을 수 있었다. 따라서 강재 보 모니터링 시스템에 효과적으로 적용할 수 있을 것으로 기대된다.
        808.
        2013.01 KCI 등재 서비스 종료(열람 제한)
        연결보를 가진 전단벽 시스템은 벽체의 개별 강성을 합산한 것보다 훨씬 큰 강성을 확보할 수 있기 때문에 효율적인 횡력저항시스템으로서 40층 이하의 중 고층 건물에 널리 적용되고 있다. 일반적으로 사용되는 철근콘크리트 연결보는 철근배근이 복잡해 시공성이 저하되고, 철골연결보의 경우에는 과도한 스티프너의 사용으로 인해 경제성이 저하된다는 단점을 가지고 있다. 따라서, 이 연구에서는 철근콘크리트와 철골부재를 합성하여 시공성 및 경제성을 개선하고 단면크기를 줄일 수 있는 불연속웨브가 적용된 프리스트레스트 합성연결보를 개발하였다. 개발한 프리스트레스트 합성 연결보의 구조적인 성능을 검증하기 위해서 전단철근비를 주요 변수로 두 개의 실험체를 제작하여 반복하중실험을 수행하였으며, 실험결과는 제안된 연결보의 내진성능을 검증하였다.
        809.
        2012.11 서비스 종료(열람 제한)
        In the current study, reinforced concrete (RC) composite beams made with precast HPFC has been manufactured in order to improve bending and shear performances of the RC beams. The construction process of the precast column system was also developed in order to apply in the field construction of official building structures.
        810.
        2012.11 서비스 종료(열람 제한)
        In this study, experimental research was carried out to improve and evaluate the seismic performance of reinforced concrete beam-column joint using carbon fiber sheets in existing reinforced concrete building. Test result shows that retrofitting specimen(LBCJ-CS1, CS2) designed by the improvement of seismic performance of reinforced concrete beam-column joints load-carrying capacities were increased 1.26~1.35 times in comparison with the standard specimen.
        811.
        2012.11 서비스 종료(열람 제한)
        Reinforced concrete coupled shear wall systems in medium and high-rise construction, where RC beams couple two or more RC walls have been frequently used. The objective of this study is to investigate seismic performance of coupling beam with headed bar.
        812.
        2012.11 서비스 종료(열람 제한)
        The results presented in this paper also provide a summary of an experimental investigation, in which reinforced concrete beams were strengthened with carbon fiber sheets and subjected to fatigue loading. The comparison shoes that the analytical modal provides reasonably accurate prediction of deflections. Although carbon fiber composites were used for the evaluation, the modal is also applicable to other types of fibers.
        813.
        2012.11 서비스 종료(열람 제한)
        The coupling beams provide transfer of vertical forces between adjacent shear walls in coupled shear wall system, which creates a frame-like coupling action that resists lots of the total overturning moment induced by the wind load or seismic load. The purpose of this study is to investigate the strain characteristics performance of coupling beams with headed bar.
        814.
        2012.11 서비스 종료(열람 제한)
        In this study, a reduction in inter-laminar shear strength of FRP reinforcing bars, which is domestically produced, subjected to high temperatures was investigated. The inter-laminar shear tests were conducted on the rebar specimens conditioned in a chamber for specified times at high temperatures. The exposure temperatures were 100℃∼300℃, The exposure time were 0.5 hours to 4 hours. It was found that the critical temperature was for both GFRP and CFRP reinforcing bars, 270℃. Based on the results, a linear equation for evaluation of the effect of exposure time is proposed.
        815.
        2012.11 서비스 종료(열람 제한)
        A strain compatibility method is based on the strain compatibility approach proposed by AISC (American Institute of Steel Construction, Inc.). The strain compatibility method assumes a linear strain of all the members. After that, set up the equilibrium equations of the state of stress in each component for calculating the location of the neutral axis of the cross-section in the presence. In this study, the reinforced concrete simple beam is analyzed by strain compatibility method for calculating the neutral axis and the bending moment. And then, a variation of neutral axis of the reinforced concrete simple beam is measured.
        816.
        2012.11 서비스 종료(열람 제한)
        Since the loads acting on a buildings cannot be precisely expected or measured, rational evaluation on structural health is in difficulties. From this reason, a numerical approach for evaluation process is presented for the displacement evaluation of continuous beams in this study. A modified curve fitting in which boundary conditions are considered and its application to continuous beam with 2 span are dealt with.
        817.
        2012.10 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 우리나라 실정에 부합되는 실용적인 원지 지진해일 예경보 체계 구축을 위해 미국과 우리나라의 지진해일 예경보 체계 현황을 파악하고, 2011년 동일본 지진해일 당시의 대처상황을 분석하였다. 우리나라 해안 지역에 영향을 미치는 원지 지진해일의 발생원 및 전파 특성을 고려하고, 지진탐지 및 수치모의 수행 능력과 가용 전문인력 등을 고려한 효율적인 원지 지진해일 예경보 체계 구축 방안을 제안하였다.
        818.
        2012.09 KCI 등재 서비스 종료(열람 제한)
        이 연구에서는 순환굵은골재를 사용한 철근콘크리트 보의 휨거동을 평가한다. 이를 위하여 골재의 종류와 흡수율이 서로 다른 3개의 실험체를 제작하였다. 모든 실험체는 4점 가력을 받도록 계획하였으며, 전단의 영향이 크도록 전단경간비를 2.5로 계획하였다. 실험체의 모멘트-곡률 관계를 예측하기 위하여 인장증강효과를 고려한 비선형 휨해석을 수행하였으며, 실험체의 전체 거동을 평가하기 위하여 전단의 영향을 고려할 수 있는 비선형 유한요소해석을 수행하였다. 실험결과, 흡수율 6%의 순환굵은골재를 사용한 실험체의 휨강도와 균열특성은 천연골재를 사용한 실험체와 서로 유사함을 확인할 수 있었다. 그리고 실험결과와 해석결과를 비교한 결과, 기존 해석방법을 이용하여 순환굵은골재를 사용한 철근콘크리트 보의 거동을 타당하게 예측할 수 있음을 확인할 수 있었다.
        819.
        2012.09 KCI 등재 서비스 종료(열람 제한)
        이 연구에서는 철강 공정에서 발생되는 전기로 산화슬래그 골재를 사용한 철근콘크리트 보의 전단 성능을 평가하였다. 이를 위하여 총 6개의 단순지지형 실험체를 제작하여 전단실험을 수행하였다. 주요 실험변수는 골재의 종류와 전단철근의 유무로 하였다. 실험체는 전단경간비가 2.5, 폭 200mm, 유효깊이가 300mm인 직사각형 단면으로 4점가력을 받도록 계획하였다. 기존 강도식을 사용하여 실험체의 전단강도를 예측하였으며, 전단해석모델을 사용한 유한요소해석을 수행하여 전기로 산화슬래그 골재를 사용한 실험체의 전단거동을 예측하였다. 실험결과로부터, 전기로 산화슬래그 골재를 사용한 실험체의 전단 성능은 천연골재를 사용한 실험체와 서로 유사한 것을 확인할 수 있었다.
        820.
        2012.08 KCI 등재 서비스 종료(열람 제한)
        일반적으로 수계의 용수공급능력을 평가하기 위해서는 수요량을 단계적으로 증가시키며 용수부족 여부를 검토하고 그 결과에 따라 수요량을 조정하는 시행착오법을 사용한다. 이것은 시뮬레이션 모형 뿐 아니라 최적화 모형의 경우에서도 마찬가지다. 그러나 이 같은 시행착오법은 수차례의 최적화를 반복하는 번거로움을 수반한다. 이에 본 연구에서는 물 부족이 발생하지 않은 최대 용수공급능력을 보다 쉽게 찾을 수 있도록 2단계의 목표계획기반 최적화 모형을 제시하였다. 즉, 제 1단계에서는 제시된 모형을 유입량 정보가 정확하다는 가정아래 최대 용수공급능력을 산정한다. 그리고 제 2단계에서는 실제 용수공급 상황에서는 미래 유입량에 대한 정보가 없는 점을 고려하여 최대 갈수기간에 한해 실시간 모의운영을 통하여 용수공급능력을 산정한다. 이 방법을 다기능 보가 신설되어 기존 수문환경과 차이점을 보이는 금강 수계에 적용하고, 완전한 정보가 있는 경우와 그렇지 않은 경우의 결과를 비교함으로써 유입량 정보가 용수공급능력에 미치는 영향을 이해하고 평가할 수 있었다.