        검색결과 246

        101.
        2007.03 구독 인증기관 무료, 개인회원 유료
        The behavior of the Tuned Liquid Damper (TLD) which has been widely used for mitigating structural vibration is generally modeled by linear wave theory and its vibration control performance is evaluated using Tuned Mass Damper (TMD) analogy. However, some previous studies showed that the properties of the TLD such as natural frequency and damping ratio were dependent on the excitation amplitude. In this study, the dynamic nonlinear characteristics of the TLD are investigated by shaking table test with varying excitation amplitude. In case of harmonic excitation experimentation, the damping ratio, natural frequency, and effective mass are obtained through envelope curves overlap of time-history curve from measured base shear and analogy base shear using simulation a freedom of simple degree modeling. In the white noise experimentation, the parameters obtained through curve-fitting of the transfer function from the table acceleration to the base shear.
        4,000원
        102.
        2006.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는, 동조액체감쇠기(이하 TLD)만을 실험적 부분구조로 이용하여 TLD가 설치된 건축구조물의 지진 응답 제어효과를 평가하기 위한 실시간 하이브리드 실험법을 제안하고 진동대 실험을 통해 실험적으로 규명한다. 제안된 실험법에서, TLD가 설치된 전체구조물은 상부의 TLD와 하부의 구조물 부분으로 각각 실험적 그리고 수치해석적 부분구조로 나누어진다. 이때 부분구조 사이의 경계면에서 작용하는 하중 또는, TLD에 의한 제어력은 진동대에 설치된 전단형 로드셀에 의해 계측되며 진동대는, 계측된 경계면에서의 제어력이 상부에 작용하고 또한 동시에 기초에 지진하중이 작용하는 수치해석적 부분구조로부터 계산된 응답으로, 상부에 설치된 TLD를 가진하게 된다. 제안된 실험법에 의한 결과와 TLD와 건물모델 모두를 제작하여 실험하는 기존의 방법에 의한 실험 결과들은 서로 잘 일치하며, 이로써 본 논문에서 제안된 실험법을 이용하여 TLD의 제어성능을 손쉽게 평가 할 수 있음을 알 수 있다.
        4,000원
        105.
        2006.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        강제 진동 실험은 구조물의 수학적 모델과 실제 모델의 상관관계를 입증하여 구조물의 성능을 정확히 평가하기 위해 중요하기 때문에, 동적 및 정적 가진 실험을 통해 구조물의 내진성능을 평가하는 다양한 기법이 사용되고 있다. 본 논문에서는 복합 질량형 감쇠기(Hybrid Mass Damper, HMD)를 이용하여 지진하중을 모사하는 실물크기 철골조 구조물의 강제진동실험이 수행되었다. ANSYS를 사용하여 구조물의 유한요소 해석모델을 구축하였고, 강제진동 실험을 통해 얻은 계측데이터를 사용하여 이 해석모델을 갱신하였다. 의사 지진 가진 실험은 HMD에 의해 유도된 층응답이 실험을 통해 갱신된 유한요소모델을 사용한 수치해석 응답과 일치함을 보여준다.
        4,300원
        106.
        2006.09 구독 인증기관 무료, 개인회원 유료
        In recently, the method estimated construction's defeat using the infrared thermography was prefer to method of new repair and estimate as a good point that simple of application and save labor, what is more economic than other techniques and can reduce need time. The purpose of this study is to develope the technique to measure the corrosion of reinforcing bars using the infrared thermal photography graphic data. In this page, the former final purpose establishment that galvanic corrosion method of reinforced bars and infrared thermography system, and studied trend of thermography and photography graphic data by parameters of corrosion of specimens, atmosphere temperature, concrete cover depth etc.
        4,000원
        107.
        2006.09 구독 인증기관 무료, 개인회원 유료
        In this study, numerical analysis of TMD to estimate optimal-design-parameter is investigated using actual excitation, and evaluated by comparing results of numerical analysis and optimal-design-parameter was devised by Soong. It assumed between 1~2 seconds the 1st mode natural period of an aged apartment which has 10~15 stories and then investigated optimal-design-parameter of actual excitation for evaluate optimal frequency ratio and damping ratio according to local site condition. At this time mass ratio was 1% and range of tuned frequency ratio was 0.8Hz to 1.2Hz at intervals of 0.01Hz, and optimal damping ratio was 1% to 14% at intervals of 0.002%. It estimated Optimal-design-parameter was evaluated by numerical analysis according to peak and RMS displacement, acceleration respectively local site. And the result of evaluated respond performance parameter respectively a period was shown low numerical-value than optimal-design-parameter was devised by Soong what is more peak acceleration indicated performance difference of 20% over
        4,000원
        108.
        2006.09 구독 인증기관 무료, 개인회원 유료
        In this study, the vibration control performance of Tuned Liquid Damper(TLD) with nonlinear properties is investigate by a with shaking table test according to large excitation. Until recently, TLDs has been investigated by behavior of liquid using equivalent TMD analogy and liner wave theory. The properties of TLDs assumed immutable but became generally known as a matter of fact TLDs behavior has a nonlinear properties that change the TLDs characteristics according to excitation. It was measured base shear and wave height in water tank at 0.01g to 0.06g as 0.01g intercals and tuned 0.6Hz, 0.8Hz. The result of shaking table test showed trend decreased amplification ratio of base shear and wave height as more increased peak accelearation of vibration, what is more jump frequency that dependent excitation dimension.
        4,000원
        112.
        2006.02 구독 인증기관 무료, 개인회원 유료
        In this study, in order to investigate the effectiveness of tuned liquid damper (TLD) for the seismic performance enhancement of the existing reinforced concrete (RC) apartment structure which is not seismically designed, shaking table test was conducted for the small scale five story RC structure with TLD. TLD model was constructed to have the frequency tuned to the first modal frequency of the structure, 2% mass ratio of the first modal mass, and 0.08 liquid depth ratio. White noise with 0.2~5Hz frequency bandwidth and harmonic load tests were performed using the shaking table at Korea Institute of Machinery and Materials, and the displacement and absolute acceleration of each floor were measured. Test results indicate that more than 30% seismic responses reduction can be achieved using TLD for RC structure under white noise and harmonic load.
        4,000원
        113.
        2006.02 구독 인증기관 무료, 개인회원 유료
        The apartment structures built using tunnel form method in 1980's, are vulnerable to lateral loads since wall elements don't exist in longitudinal direction and especially they were not seismically designed. In this study, in order to evaluate the seismic performance of those apartment structures, nonlinear analysis was performed and static test was conducted using small scale partial specimen. Both shear and moment should be considered for the structure subject to lateral load. Most existing methods, however, consider only shear force in test specimen because it is difficult to realize the actual moment distribution of the practical structure, and furthermore axial force is often neglected. This study propose a testing method which can realize similar moment and axial force distribution of a specimen to that of the practical structure by controlling the lateral loading condition. Numerical analysis was performed using moment-curvature curve considering stiffness degrading parameter, ductility-based strength and energy dissipation. The result of this study shows that only 15~20% difference exist between analysis and test, which confirms that the performance of wall elements in a non-seismically designed wall type reinforced concrete apartment can be accurately evaluated.
        4,000원
        114.
        2006.02 구독 인증기관 무료, 개인회원 유료
        The seismically design of building has objects to minimize in judge of people by preventing brittle fracture and to guarantee serviceability of building. But I come to the conclusion that the seismically design is not easy to use, even though we recently use it applyed with shear wall-type evaluation method, because we don't know how to estimate seismic performance of existing reinforced concrete wall-type apartment and evaluation method of wall-type apartment. so in this study, we conduct analysis program by using MIDAS-Gen & MIDAS-SDS, structure analysis program, after conducting a preliminary evaluation about research apartment by seismic performance evaluation method of existing safety & Technology corporation. In addition we show the problem when research apartment is applied with shear wall-type evaluation method that is estimate and grade of seismic performance level by capacity spectrum method.
        4,000원
        115.
        2005.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적 : 본 연구는 국내에서 많이 사용되고 있는 표준화된 인지 검사 도구인 한국판 간이 정신상태 판별검사(MMSE-K)와 알렌 인지 수준 판별 검사(ACLS)를 정상노인을 대상으로 일반적인 특성을 비교하고 수행점수간의 상관관계를 구하여 타당도를 알아보았다. 연구방법 : 2005년 9월 20일부터 11월 8일까지 원주 지역사회 노인복지과에 등록된 노인 중(60~89세) 평가를 허락한 정상노인 50명을 대상으로 MMSE-K와 ACLS에 능숙한 작업치료사가 ACLS와 MMSE-K를 각각 평가하였다. 결과 : ACLS와 연령과는 역상관관계를(r=-.417), 학력과는 정적상관관계(r=.359)를 나타내었으며 유의하였다. MMSE-K의 수행결과 연령과는 역상관관계를, 학력과는 정적상관관계를 보였으며, ACLS와 MMSE-K의 수행점수는 두 검사도구간의 유의한 정적상관관계( r=.439)를 보였다. 결론 : 본 연구의 결과를 통하여 ACLS는 MMSE-K와 유의한 정적 상관관계를 가진 도구로 확인되었으며 인지기능수준이 떨어지는 노인 및 환자를 대상으로 인지평가시 유용하게 사용할 수 있을 것이다.
        4,000원
        116.
        2005.08 구독 인증기관 무료, 개인회원 유료
        Recently, earthquakes occur over 30 times a year in Korea. In addition, earthquakes originating from the neighborhood countries were sensed in Korea and caused serious human casualties and economic loss. In Japan, U.S.A., New Zealand and etc., forces seismic design of building structures to prevent seismic damage. In Korea, seismic design has been applied to building structures with a scale larger than defined in the building code since 1988. However, serious seismic damages are expected for wall-type apartment buildings, which were designed before 1988 without application of seismic design. Therefore, appropriate seismic retrofitting methods that are economical and easy to construct are required for such buildings. In this study, seismic retrofitting methods using steel plates or sections are developed for the wall-type apartment buildings. Proposed retrofitting methods improve lateral stiffness of the wall-slab system without excessive increment of loads on base structure. The effect of retrofitting using plates, T-sections and H-sections was examined experimentally for wall-slap system test models. In the experiment, the performance of the joint and slab of the test models was improved and the retrofitting effect was proved to be excellent.
        4,000원
        117.
        2005.08 구독 인증기관 무료, 개인회원 유료
        Earthquake resistance design has been developed many countries like Japan, USA, Mexico, New Zealand etc., which countries have experienced many earthquakes. Nowadays, earthquake resistance design has come into worldwide use. In Korea, the seismic design regulations have been established since 1988 in order to minimize the economic losses. Recently performance based design method has been adopted as a new Earthquake resistance design method. These regulations, however, are targeted for newly constructed buildings, In Korea, there are no regulations for existing buildings that built before 1988. So, we need to prepare the regulations that evaluate the seismic performance, furthermore proper retrofitting design guideline needs to be proposed when remodeling old buildings. This study was performed that many existing apartments is being a Remodeling object when considering the present condition of existing apartment and the problerns of cost and environment in the future plan. When Remodeling construction is reviewed by former the Seismic Performance Evaluation Method, generating problems is evaluation by using Push-over. According to this, it provides the appropriate method of calculating the Seismic Performance Index.
        4,000원
        118.
        2005.08 구독 인증기관 무료, 개인회원 유료
        Recent building structures are superior in its ability but they are light and flexible, and so have problems of habitability induced by building vibration. In general, the problem of vertical vibration is not considered in structural design. However, in terms of serviceability for inhabitants in buildings, the estimation of vertical vibration in design stage is important. Characteristics of vertical vibration is changed by modeling method of beam-column joint. To check the characteristics of vertical vibration, many tests and analyses were conducted on constructing building in Seoul. Results of tests and analyses were compared using transfer function. As a results, to check the vertical vibration characteristics, the cramp ratio of beam-column joint must be considered and reduced to 50% ~ 60% in structural design.
        4,000원
        119.
        2005.08 구독 인증기관 무료, 개인회원 유료
        This paper proposes substructuring method using experimental model of only upper MDOF structure and verifies its applicability to shaking table test. The structure considered in the test is a five-stoty shear type building model which is divided into two parts, of which one is lower three floors for a numerical substructure and the other is upper two floors for a experinlental substructure. The experimental substructure is excited by the shaking table and the acceleration data for the input of shaking table is obtained numerically from lower numerical part. For implementation of the proposed substructuring method, a controller of the shaking table is designed reflecting experimental model. In comparison with acceleration responses, which are measured from experinlental part of 3rd, 4th, and 5th floor and are numerically calculated from the original five-stoty structure, it is observed that the experimental results match well with the numerical results in both time and frequency domain.
        4,000원