검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 211

        21.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The objective of this study is to present a practical application method for measuring the setting time of concrete in the field, considering different concrete blending and curing environments. METHODS : In the experimental environment of the concrete setting experiment, a mold was made in the laboratory, and the curing temperature was performed at laboratory room temperature (20-25 ℃), heater (30 ℃), and dryer (40 ℃). In the field, the experimental method was performed in summer and autumn, setting experiments on penetration resistance, ultrasonic pulse velocity, and semi-calorimeter. RESULTS : The result of the concrete setting time experiment was that the early setting time was achieved in the combination of filash and slag when the concrete was mixed, and the setting time in the curing environment was the same as the early setting time in the field. The setting time measurement method shows the correlation of the high crystal coefficient at UPV with 0.99 based on PR and the good ratio of 92 % to 107 % on average. In addition, the semi-calorimeter shows a good crystal coefficient of 0.96 to 0.99 and a good setting time of 88 % to 101 % on average. CONCLUSIONS : The analysis of the setting time of the concrete shows that the curing temperature is more affected than the mixture, and it is considered that the UPV test, which evaluates the reliability of the degree of purification, is easy to sampie among the three methods.
        4,000원
        26.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : For high driving performance and service life of cement concrete pavement, construction quality must be secured. The construction quality is to be measured after pavement construction, but in this case, it is difficult to improve construction quality. Therefore, it is necessary to develop a method for measuring and correcting the profile of the pavement and subbase so that the construction quality can be monitored immediately after construction. METHODS : The device that can measure the construction quality of cement concrete pavement has been developed. Through the experiment simulating the field situation, the profile of the pavement and subbase was measured and calibration method was developed. RESULTS : In the measured profile, an outlier by the sensor and noise by the sensor and vibration were measured, and a step-like profile was measured differently from the acture one. To remove outliers, the boxplot outlier removal method was applied by overlapping each data group. The noise were removed by a low pass filtering. And, it was calibrated to a profile similar to the acture one through the sampling interval adjustment and the weighted moving average method. CONCLUSIONS : The method that can measure and calibrate the profile that is almost identical to the actual one has been developed. Accordingly, it is expected that the performance of the pavement can be improved by accurately monitoring the construction quality immediately after construction.
        4,200원
        27.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study develops a new device system for measuring a slope of object with non-adhesive, non-contact and non-face-to-face, namely Inclinometer Slope Laser Measuring (ISLM), that is applicable in the field. This system includes cradle, laser, camera, and computer and the filming and is performed after laser projection at programmed intervals. After measuring the amount of displacement converted to numerical values, these values can then be transferred to the office using the selected data transmission method. The obtained results from the test carried out to verify the reliability of the ISLM system indicated that the ISLM system can measure with accurately level of 0.1mm/Pixel at 1m distance and when increasing the camera resolution, the precision might increase proportionally. Therefore, the proposed measure system may widely apply on-site for various constructions, especially, in the case of object with very high surface temperature where exhibits difficulty to directly measure the adjacent structures. However, due to the sensitive reaction to the illuminance, this method can be applied with caution at times of large changes in illuminance, such as at dawn and at dusk.
        4,000원
        28.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to industrial development, the importance of GD&T tolerance is growing day by day. Roundness measurement means the size deviated from the ideal circle. Roundness evaluation methods include LSCI, MZCI, MCCI, and MICI. In this experiment, measurement deviations according to roundness measurement methods such as radius method, diameter method, and three-point method were studied using the same roundness specimen. The measurement method was measured 20 times each by the measurer, and the average value and dispersion of each data obtained through the experiment were confirmed. Through the experiment, it was confirmed that the diameter method, the three-point method, and the radius method were measured and spread out in the order of magnitude. In addition, the interrelationship according to each measurement method was confirmed using the experimental design method. The test statistic value (P) was greater than 0.05 through hypothesis testing, and the null hypothesis was rejected and the alternative hypothesis was adopted in the experiment.
        4,000원
        29.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        High-strength low-alloy (HSLA) steels show excellent toughness when trace amounts of transition elements are added. In steels, prior austenite grain size (PAGS), which is often determined by the number of added elements, is a critical factor in determining the mechanical properties of the material. In this study, we used two etching methods to measure and compare the PAGS of specimens with bainitic HSLA steels having different Nb contents These two methods were nital etching and picric acid etching. Both methods confirmed that the sample with high Nb content exhibited smaller PAGS than its low Nb counterpart because of Nb’s ability to hinder austenite recrystallization at high temperatures. Although both etching approaches are beneficial to PAGS estimation, the picric acid etching method has the advantage of enabling observation of the interface containing Nb precipitate. By contrast, the nital etching method has the advantage of a very short etching time (5 s) in determining the PAGS, with the picric acid etching method being considerably longer (5 h).
        4,000원
        30.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : This study suggests an estimated texture depth (ETD) equation for concrete pavements, applicable to highway pavement texture, and the measurement method of mean profile depth (MPD) in a longitudinal texture. METHODS : First, we proposed the most suitable ETD equation through the correlation between ETD data and the measured mean texture depth (MTD) data. Second, we suggested a novel MPD measurement method, by checking the error of the ETD data and measured MTD data by the measurement method. RESULTS : The ETD equation presented by Fisco and Plati was considered the most appropriate for the transverse texture. In addition, the correlation between ETD and the measured MTD was good in the longitudinal measurement method. The ETD equation of Fisco and Plati is suitable for longitudinal texture, and the MPD measurement method obtained good results when applied to transverse measurements. To verify the novel measurement method, we confirmed the correlation between the SR and MPD data using a novel method. The correlation for the novel measurement method is 0.7. CONCLUSIONS : Accordingly, the ETD equation presented in the existing literature has a good correlation between ETD data and the measured MTD data, but it did not reflect longitudinal texture data. Therefore, we assumed the ETD equation produced in this study, and suggested the transverse measurement method in the longitudinal texture.
        4,000원
        31.
        2021.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        대표적인 연성변형구조인 습곡에서 습곡축의 자세는 3차원 습곡구조의 발달양상뿐만 아니라 변형 당시의 최대 수평주응력 방향에 대한 정보를 수집하는데 중요한 역할을 한다. 이러한 이유로 습곡축의 자세를 파악하는 것은 매우 중요하나 습곡축이 노출되는 경우가 흔하지 않기 때문에 습곡과 관련된 구조요소들을 이용한 다양한 방법들이 제시되고 이용되어 왔다. 따라서 이러한 다양한 측정방법에 대해 간략히 소개하고, 이들 방법들에 대한 신뢰성을 평가하기 위하여 같은 습곡에 대해 다른 측정법을 사용하여 측정한 습곡축들을 비교분석 하였다. 이를 위해 습곡구조가 잘 발달해 있는 충북 단양지역 조선누층군의 석회암층들과 평안누층군의 만항층에 걸쳐 6곳의 노두에서 습곡구조의 습곡축 자세를 측정하고 비교하였다. 비교결과 다른 방법에 의해 측정된 것들도 대부분 서로 잘 일치하는 양상을 보여 다양한 측정방법들의 실제 활용이 가능함을 보여주었다. 또한 단양지역의 습곡구조는 서북서 방향의 습곡축을 가지는 한 곳을 제외한 나머지 노두에서 모두 북-북북동 내지 북동 방향의 습곡축을 보였으며, 이는 서북서-동남동 내지 북서-남동 방향 의 최대수평주응력 환경에서 만들어진 습곡들로 판단된다. 서북서 방향의 습곡축은 다른 시기의 습곡작용을 지시하는 것으로 보이며, 북-북북동 방향의 습곡축을 가지는 습곡구조와 북동 방향의 습곡축을 가지는 습곡구조 사이의 주향 차이는 하나의 습곡작용에서 습곡구조의 규모에 따라 다소 차이가 생긴 것으로 해석하였으나, 증거를 확인하는 추가적인 연구가 필요할 것으로 사료된다.
        4,000원
        33.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : In this paper, the measurement criteria was determined by assessing the factors influencing the measurement of bending resonance frequency which is not specified in KS F 2437. METHODS : The durability evaluation analysis of concrete beam specimens was performed immediately after freezing and thawing processes. It is primarily aiming at improving the repeatability and reproducibility of measurement results by providing measurement criteria for various measurement factors that can occur during the collection of resonance frequency data. An independent concrete durability test (KS F 2456) was executed with the proposed measurement protocol for evaluation. RESULTS : A measurement protocol was proposed to determine the transverse resonance frequency of concrete beam specimens. CONCLUSIONS : It was concluded that the proposed measurement protocol may be used for the concrete durability test; where the resonance frequency could be stably collected.
        4,000원
        34.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : In this study, the flatness of a sidewalk surface was evaluated by measuring the vibration acceleration experienced by wheelchair users passing the sidewalk using a walking measure. The objective of this study is to derive a linear equation for converting the vibration acceleration of a sidewalk surface measured using a walking measure into vibration acceleration of a wheelchair. METHODS : To this end, field measurements were obtained. Twenty sites with different sidewalk surface materials were selected to measure the vibration accelerations of the walking measure and wheelchair. A regression analysis was conducted with the measured root mean square value of the vibration acceleration, and a linear equation expressing the walking measure and wheelchair vibration acceleration was derived. RESULTS : The regression analysis was conducted by inputting the vibration acceleration of the wheelchair into the Y-axis and that of the walking measure into the X-axis. Thus, a linear equation between the walking measure and wheelchair acceleration could be derived. Further, linear equations could be derived and applied based on the situation using various standard walking measures and wheelchairs. These equations could be used to convert the vibration acceleration of the walking measure into that of the wheelchair. Substituting the converted vibration acceleration into the comfort level specified in ISO 2631-1 was expected to indicate the flatness of the sidewalk. CONCLUSIONS : This study confirmed that a linear equation for the two vibration accelerations could be derived by measuring the vibration accelerations of the walking measure and wheelchairs of 20 different sites. The vibration acceleration measured using the walking measure could be converted into that of the wheelchair using this linear equation. In addition, the flatness of the sidewalk could be evaluated by measuring the vibration acceleration of the walking measure using this linear equation.
        4,000원
        36.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to improve the noise measurement method of noise sources and the corresponding noise reduction measures during each manufacturing process closest to the workers in the large and hige power machine. To this end, the noise generated in the large and high power machine was measured and analyzed, and the frequency characteristics of noise sources and the causes of noise were identified. The noise map was used to predict the noise reduction effect. Moreover, it is expected that this will ultimately contribute to the reduction of human risks caused by the noise of the large and high power machine.
        4,000원
        37.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Several analytical measurement techniques have been developed over the years for ammonia (NH3). However, the field monitoring of NH3 still remains a significant challenge owing to the wide range of possible environmental conditions and NH3 concentration. In this regard, it is imperative to ensure the quality control of techniques to measure the NH3 emission levels reliably. A present study was conducted to compare the five analytical methods for the measurement of atmospheric NH3 via validation tests under laboratory and field conditions. The analytical instruments applied in the present study were based on wet chemistry, gas detection tube, electrochemical sensor, photoacoustic spectroscopy, and cavity ring-down spectroscopy. The reproducibility and linearity of all the analyzed methods were observed to be high with the relative standard deviation and coefficient of determination (R2) being 10% and > 0.9, respectively. In the case of wet chemistry and high NH3 concentration, the measured NH3 results were found to be close to the actual standard gas levels. Response times of electrochemical sensor showed faster from the instruments utilized more than one year and the high NH3 concentrations. In the field tests, NH3 concentration showed higher in the manure storage tank compared with the pig-pen. In both cases, the NH3 concentration levels measured by gas detection tube were found to be quite different from that of wet chemistry. It was proposed that such differences in NH3 concentration could arise due to the inherent instrumental characteristics and the variations in air velocity during sampling/measurement. The periodic instrumental maintenance, verification, replicate analyses, and suitable consideration of environmental factors should be considered for a more reliable measurement of NH3 concentration under real field conditions.
        4,300원
        39.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to provision the standard method for ensuring the reliability of measuring indoor air quality in public transportation. The objective is to determine the difference in the measured concentration values according to various conditions. These variables include measurement conditions, measurement equipment, measurement points, and measurement time. The value differences are determined by measuring the PM10 and CO2 concentration of subways, and express buses and trains, which are targets of indoor air quality management. The concentration of CO2 was measured by the NDIR method and that of PM10 was measured by the gravimetric method and light-scattering method. Statistically, the results of the concentration comparison according to the measurement points of the public transportation modes were not significantly different (p > 0.05), and it is deemed that the concentration is not affected by the measurement points. In terms of the concentration analysis results according to the measurement method, there was a difference of the concentration between the gravimetric and light scattering method. In the case of the light scattering method, the concentration differed depending on whether it was corrected with standard particles in the laboratory environment.
        4,200원
        40.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The concentrations of volatile organic compounds (VOCs) and odor-inducing substances were measured using selected ion flow tube mass spectrometers (SIFT-MS) and a drone equipped with an air quality monitoring system. SIFT-MS can continuously measure the concentration of VOCs and odor-inducing substances in realtime without any pre-treating steps for the sample. The vehicle with SIFT-MS was used for real-time measurement of VOC concentration at the site boundaries of pollution sources. It is possible to directly analyze VOCs concentration generated at the outlets by capturing air from the pollution sources with a drone. VOCs concentrations of nine spots from Banwol National Industrial Complex were measured by a vehicle equipped with SIFT-MS and were compared with the background concentration measured inside the Metropolitan Air Quality Management Office. In three out of the nine spots, the concentration of toluene, xylene, hydrogen sulfide, and methyl ethyl ketone was shown to be much higher than the background concentration. The VOCs concentrations obtained using drones for high-concentration suspected areas showed similar tendencies as those measured using the vehicle with SIFTMS at the site boundary. We showed that if both the drone and real-time air quality monitoring equipment are used to measure VOCs concentration, it is possible to identify the pollutant sources at the industrial complex quickly and efficiently check sites with high concentrations of VOCs.
        4,000원
        1 2 3 4 5