검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 83

        21.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Seismic isolation systems have typically been used in the form of base seams in mid-rise and low-rise buildings. In the case of high-rise buildings, it is difficult to apply the base isolation. In this study, the seismic response was analyzed by changing the installation position of the seismic isolation device in 3D high - rise model. To do this, we used 30-story and 40-story 3D buildings as example structures. Historic earthquakes such as Mexico (1985), Northridge (1994) and Rome Frieta (1989) were applied as earthquake loads. The installation position of the isolation device was changed from floor to floor to floor. The maximum deformation of the seismic isolation system was analyzed and the maximum interlaminar strain and maximum absolute acceleration were analyzed by comparing the LB model with seismic isolation device and the Fixed model, which is the base model without seismic isolation device. If an isolation device is installed on the lower layer, it is most effective in response reduction, but since the structure may become unstable, it is effective to apply it to an effective high-level part. Therefore, engineers must consider both structural efficiency and safety when designing a mid-level isolation system for high-rise buildings.
        4,000원
        22.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the concept of an outrigger damper system with a damper added to the existing outrigger system has been developed and applied for dynamic response control of high-rise buildings. However, the study on the structural characteristics and design method of Outrigger damper system is in the early stages. In this study, a 50 story high - rise building was designed and an outrigger damper system with viscoelastic damper was applied for wind response control. The time history analysis was performed by using the kaimal spectrum to create an artificial wind load for a total of 1,000 seconds at 0.1 second intervals. Analysis of the top horizontal maximum displacement response and acceleration response shows that outrigger damper systems are up to 28.33% and 49.26% more effective than conventional outrigger systems, respectively. Also, it is confirmed that the increase of damping ratio of dampers is effective for dynamic response control. However, since increasing the damping capacity increases the economic burden, it is necessary to select the appropriate stiffness and damping value of the outrigger damper system.
        4,000원
        23.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Base isolation system is generally used for low-rise buildings. For high-rise buildings subjected to earthquake loads, a mid-story isolation system was proposed and applied to practical engineering. In this study, seismic responses of high-rise buildings considering the installation story of the mid-story isolation system were evaluated. To do this, the 20-story and 30-story building were used as example structures. Historical earthquakes such as Kobe (1995), Northridge (1994) and Loma Prieta (1989) earthquakes were employed applied as earthquake excitations. The installation location of the mid-story isolation system was changed from the bottom of the 1st floor to the bottom of the top floor. The seismic responses of the example building were investigated by changing the location of the isolation layer. Based on the analytical results, when the seismic isolation system is applied, story drift ratio and acceleration response are reduced compared to the case without the isolation system. When the isolation layer is located on the lower part of the building, it is most effective. However, in that case, the possibility that the structure is unstable increases. Therefore, an engineer should consider both structural efficiency and safety when a mid-story isolation system for a high-rise building is designed.
        4,000원
        24.
        2017.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the trend is emerging a variety of irregular tall buildings. It is important to design the building for lateral load according to this trend. Fluid Structure Interaction(FSI) simulation can be performed to understand the vibrations of the structure against dynamic wind loads. In order to make the physical characteristics of the actual structure and the analytical model the same, we studied core inserting equivalent stiffness modeling method. As a result of this analysis, the stiffness of the structure can be set similar to that of the two axes of the structure, and turbulence can be reproduced through the acceleration tendency.
        4,000원
        25.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The demand for skyscrapers is increasing worldwide. Until now, various lateral resistance structures have been used for lateral displacement control of high-rise buildings. An outrigger damper system has been introduced recently to improve lateral dynamic response control performance further. However, a study of outrigger damper system is yet to be sufficiently investigated. In this study, time history analysis was performed to investigate the control performance of an outrigger damper system of high-rise building under eccentric loading. To do this, an actual scale 3-dimensional tall building model with an outrigger damper system was prepared. The control performance of the outrigger damper system was evaluated by varying stiffness and damping values. On the top floor torsional angle response to the earthquake load, was greatly affected by damping value. And the displacement response was affected greatly by the stiffness value and damping value of damper system. In conclusion, it is necessary to select the proper damping and stiffness values of the outrigger damper system.
        4,000원
        26.
        2016.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study is to apply performance-based seismic design to high-rise apartment buildings in Korean considering collapse prevention level. The possible issues during its application were studied and the suggestions were made based on the findings from the performance-based seismic design of a building with typical residential multi-unit layout. The lateral-force-resisting system of the building is ordinary shear walls system with a code exception of height limit. In order to allow the exception, the serviceability and the stability of the ordinary shear wall structure need to be evaluated to confirm that it has the equivalent performance as the one designed under the Korean Building Code 2009. The structure was evaluated whether it satisfied its performance objectives to withstand Service Level and Maximum Considered Earthquake.
        4,000원
        27.
        2016.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Observations of the damages to high-rise reinforced concrete (RC) wall building structures caused by by recent earthquakes in Chile (Mw 8.8, February 2010) and New Zealand (February 2011, ML 6.3) have generally exceeded expectations. Firstly, this study estimated the seismic damage levels of 15-story RC box-type wall building structures using the analytical models calibrated by the results of a shaking table test on a 1:5 scale 10-story RC box-type wall building model. Then, the seismic fragility analysis of the prototype model was conducted by using the SAC/FEMA method and the incremental dynamic analysis (IDA). To compensate for the uncertainties and variability of ground motion and its impacts on the prototype model, in the SAC/FEMA method, a total of 61 ground motion records were selected from 20 earthquakes, with a magnitude ranging from 5.9 to 8.8 and an epicentral distance ranging from 5 to 105km. In the IDA, a total of 11 ground motion records were used based on the uniform hazard response spectrum representing a return period of 2,475 years. As a result, the probabilities that the limits of the serviceability, damage control, and collapse prevention would be exceeded were as follows: from the SAC/FEMA method: 79%, 0.3%, and 0%, respectively; and from the IDA: 57%, 1.7%, and 0%, respectively.
        4,000원
        28.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Since the 1980s, the number of large space buildings in Korea has consistently been increasing due to large scale international competitions such as the Olympics and the World Cup, demands for environmental improvement, and development of structural systems. Due to these reasons, this paper conducted a comparative analysis on terrorism risk factors of large space structure and skyscrapers in Korea. The results suggest that the total risk level of high-rise and large space structure was "medium level risk" and that the terrorism risk level for large space structure was as high as that for high-rise buildings. As it relates to the risk levels depending on scenarios, terrorism risks to large space structure were higher than high-rise buildings in the "internal explosion" and "internal intrusion" categories. And the results of analyzing explosion-related scenarios except for CBR suggest that terrorism risks to large space structure were highest when it comes to Internal-Explosive followed by Internal-Intrusion and Explosive-Zone I; and the results showed a regular pattern. On the other hand, in the case of high-rise buildings, terrorism risks were highest in Internal-Explosive followed by Explosive-Zone I and Explosive-Zone II; and the results showed an irregular pattern.
        4,000원
        29.
        2015.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Response spectra of a building are made with a SDOF system taking into account a first mode shape, even though higher modes may affect on the dynamic responses of a high-rise building. A soft soil layer under a building also affects on the responses of a building. In this study, seismic responses of a MDOF system were investigated to examine the effects of higher modes on the response of a tall building by comparing them with those of a SDOF system including the kinematic interaction effect. Study was performed using a pseudo 3D finite element program with seven bedrock earthquake records downloaded from the PEER database. Effects of higher modes on the seismic responses of a tall building were investigated for base shear force and base moment of a MDOF system including story shear forces and story moments. Study results show that higher modes of a MDOF system contribute to a reduction of base shear force up to 1/4-1/5 of KBC and base moment. The effect of higher modes is more significant on the base shear force than on the base moment. Maximum story shear force and moment occurred at the top part of a building rather than at a base in the cases of tall buildings differently from short buildings, and higher modes of a tall building affected on the base forces making them almost constant at the base. A soft soil layer also affects some on the base shear force of a high-rise building independently on the soft soil type, but a soft soil effect is prominent on the base moment.
        4,000원
        30.
        2015.04 구독 인증기관 무료, 개인회원 유료
        Everyday many casualties have been occurred in the buildings. the design of the fire safety of buildings is based on the regulations. Otherwise, the secure for fire safety performance has not been designed in the practical aspects. These problems are caused by the incentive effects. From the perspectives of building owners, they do not have the incentives for direct investment on the safety plan of fire-rescue. So, it is necessary to force the laws and regulations on them. In addition, a special evacuation stairs of the apartment with the ventilation equipment is not being secure at all. Instead, an installation of special evacuation stairs in/outside the open window inside ancillary rooms should be reviewed.
        4,000원
        31.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        High rising of the buildings offers a number of risk factors than ever before with regard to fire prevention. Especially in the construction site of high-rise buildings, people waste golden-time during the evacuation because temporary fire fighting facilities are not installed and transferred to a large fire because of fire suppression failure. In this study, the researcher derives the problems of fire protection in high-rise buildings construction sites and proposed the measures in such the legal aspects as fireᆞ building construction code and etc. There are the legal improvements such as orders of construction suspension in the problems of fire safety, appointing fire safety manager, temporary fire protection installation standards, enhancing penalty provisions regarding the use of fire, operating self fire brigade, confirming on-site after completing fire-protection facalities, establishment or strengthening special fire-protection investigations
        4,300원
        32.
        2015.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        근래 국내 초고층 주상복합 건물에는 철근콘크리트구조가 보편적으로 적용되는데, 이러한 철근콘크리트 초고층 주상복합 건물은 시공 시점에 따라 구조적인 문제가 발생할 수 있다. 따라서, 시공 중인 철근콘크리트 초고층 주상복합 건물에 대하여, 시공 시점별 구조 안전성 및 횡력저항성능을 검토하고자 한다. 이를 위해, 예제 모델로 탑상형의 초고층 주상복합 60층 건물을 선정했고, 기존의 범용구조해석 프로그램을 사용하여 구조해석을 수행하였다. 각 시공 시점별 10층, 20층, 30층, 40층, 50층, 60층 완료모델과 60층 완공단계 모델의 구조성능을 비교하였다. 구조성능 비교를 위해 이 모델들의 고유치해석을 수행하였으며, 횡력저항성능과 부재별 단면성능을 검토하였다. 횡력저항성능 검토를 위해 횡변위비와 층간변위비를 검토했고, 부재별 단면성능 검토는 완공단계에 대한 설계강도비와 시공단계의 설계강도비를 비교하여 부재안전성을 검토하였다. 이 연구를 통해, 시공 중인 철근콘크리트 초고층 건물의 구조 안전성을 검토하고 시공단계에 적합한 구조해석 및 설계하중의 가이드라인을 제시하고자 한다.
        4,000원
        33.
        2012.11 구독 인증기관 무료, 개인회원 유료
        Recently buildings are constructed in larger and higher scales and becoming more complex. Every country in the world is competing to build high-rise buildings. Korea also has and is constructing high-rise buildings, like the 123story Jamsil Lotte Super Tower. However from small to large scale buildings and on construction sites there still are fire safety accidents that occur continuously. Therefore to improve fire safety plan, examining the actual fire safety management and understanding fire risk analysis Using Fire Modeling through Computer Simulation. Fire safety management plan related fire safety cases were collected an dan analyzed for the study. Also hazard analysis of High rise Buildings under fire compared with existing fire law sand regulations.
        4,000원
        34.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, For the most efficient use of spaceis, high-rise buildings tend to increase. So it is with Korea, too. Besides, today high-rise buildings grows due to fire damage to life and property at large. In this study, Through analysis of domestic and foreign fire case and listen to the high-rise building fire managers, tenants, professionals advice, when the fire from the high-rise building, effective fire suppression tactics should we wish to research ways. In addition, we have used the car gondola was installed outside the fire suppression methods in studying. So that fire-fighting is a fire place can be reached quickly, many casualties and property damage, will be reduced.
        4,000원
        35.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 인공지진파 및 기록 지진파를 이용하여, KBC2009 규준으로 설계된 강구조 건물의 거대 건물에 대한 내 력 여유도를 평가하는 것을 목표로 하고 있다. 이 논문에서는 검정에 있어서 콘크리트 슬래브로 층강성이 고정되어 있는 2-D 프레임을 고려하였고, 각각의 프레임을 구성하고 있는 보와 기둥 부재는 각 부재단에 소성힌지를 적용하 였다. 검정에 사용한 해석법은 응답 스펙트럼을 이용한 모드 해석과 기록 및 인공지진파를 이용한 시간이력해석을 선택하여 모델의 거동을 조사하였으며 해석에서는 P-delta 효과를 고려한다.
        4,000원
        36.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Contrast a general building high rise buildings itself has a kind of risk. In this study, the risk of a number of high rise buildings have fire fighting safety management of the particular risks associated with looking for ways to minimize focused. Issues include self fire protection. disaster management, building code and fire code of the mismatch, such as fire protection facilities aspects are explained in terms of three kinds, and for it to take steps in the direction suggested an alternative for high rise buildings. Although differences of opinion between departments will not be easy to fire fighting and building codes regarding conflicts of codes above all require immediate resolution, and high rise buildings to create a standard for effective risk management manual countermeasures will also be ensured.
        4,000원
        37.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 테러의 발생빈도가 증가하는 가운데 테러는 불특정 다수의 사람이 모이는 건물에서 집중적으로 발생하고 있다. 이중 고층, 초고층 빌딩에서 발생하는 테러는 막대한 피해를 발생시킨다. 이에 따른 건물의 테러피해 경감을 위한 다양한 연구가 필요하다. 본 논문에서는 비교적 수행절차가 간단하며 단기간에 실행이 가능한 Fema 455 - Rapid Visual Screening을 통해 현재 사용 중인 국내 고층 초고층 건물의 테러에 대한 위험도를 평가하여 국내 건물이 가지는 공통적인 테러 위험요소를 확인하였다. 평가결과 대상 건물은 모두 중위험도의 범위에 있다. 이는 국내 고층, 초고층 건물의 외부 환경적인 특징이 비슷한 데에 그 원인이 있었다.
        4,000원
        39.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 초고층 건축물 외부공간의 식물 피복 상태가 온도변화에 미치는 영향을 파악하고자 서울시에 위치한 초고층 건축물 12개소를 대상으로 연구를 수행하였다. 초고층 건축물 외부공간의 토지 피복 유형별 온도 차이 분석을 위해 6개 유형(외곽도로, 포장지, 관목/초지, 단층교목식재지, 다층식재지, 수경시설)으로 건축물외부공간의 피복유형을 구분하였으며 토지이용유형별 대표지점에서 온도를 실측하였다. 건축물 12개소의 주변 환경차이를 고려하기 위해 외곽도로의 중앙부에 대조구를 선정하여 온도를 측정한 후 일원배치 분산분석을 토대로 유사한 온도경향을 보이는 대상지를 4개 그룹으로 분류하였다. 분류된 그룹의 토지 피복 유형과 외부 공간 온도와의 일원배치 분산분석결과, 주로 단층교목식재지, 수경시설, 다층식재지는 저온역에 속하였으며, 관목/초지, 포장지, 외곽도로는 고온역에 속하였다. 저온역과 고온역의 온도차이는 약 1.06~6.17℃의 차이를 보였다. 그러나 조성된 식재지와 수경시설 면적의 협소, 건축물로 인한 일사도달량의 저감과 반사량의 증가 등으로 초고층 건축물 외부공간 온도에 미치는 영향이 다양하게 나타났다. 이에 각 공간에 필요한 녹지량과 수공간의 면적을 조성 전 미리 산출하여, 효과를 발휘할 수 있는 최소한의 면적과 녹지량을 확보할 필요성이 있었다.
        4,300원
        40.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 풍하중을 받는 고층 구조물의 진동저감을 위하여 사용되어온 전단형 점탄성 감쇠기의 2D, 3D FEM 모델을 이용하여 정밀하게 해석하여 점탄성재료와 이들을 결합하는데 사용하는 재료의 특성이 에너지 소산에 미치는 영향을 평가하였다. 특히 점탄성재료와 강재의 접합방식 및 크기, 형상등이 에너지 소산능력에 미치는 영향을 분석하였다. 이러한 정밀해석과정을 통하여 점탄성 감쇠기의 이력거동을 고찰 분석하고 이를 댐퍼설계에 활용하기위한 설계식을 제안하는 기초자료로 사용할 수 있게 하였다.
        4,000원
        1 2 3 4 5