검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 444

        381.
        2013.10 서비스 종료(열람 제한)
        Recently, retrofit by using fiber reinforced polymer (FRP) has been widely applied to building structure. However, it loose the retrofit contribution under high temperature due to fire because of its low glass transition temperature. In this manner, this paper presents a study on the development of fire resistant capacity in FRP retrofit system. Thermal transition of various fire resistant materials were verified by performing high temperature loading test. As a result, it was found that calcium silicate and alumino silicate had high resistance on the heat transition.
        382.
        2013.10 서비스 종료(열람 제한)
        Field test was carried out to verify the performance of high-performance Weigh-In-Motion system which was developed to enhance the precision and durability. As a result, the overall measurement error has been distributed in the range of 5 % for total weight and axle weight of vehicle.
        383.
        2013.10 서비스 종료(열람 제한)
        In this paper, we developed a performance evaluation system which enables to evaluate surface condition and sectional shape change of structure. We use various convergence technology such as 3D laser scanning, digital image processing and texture mapping. This modular system is quite practicable in matters of many current structures. This system can solve the problems in current visual inspection of structures, and systemize the inspection tasks scientifically.
        384.
        2013.10 서비스 종료(열람 제한)
        In this study, an automated cable non-destructive test (NDT) system was proposed to monitor the steel cable. Magnetic Flux Leakage (MFL) method was applied for the cable inspection. A multi-channel MFL sensor head was fabricated using Hall sensors and permanent magnets. A wheel based Cable climbing robot was used to improve the accessibility to cable. In addition, remote data transmission and robot control were possible by applying the Wireless LAN communication. Finally, developed element techniques were integrated to MFL based Cable Climbing NDT system, and the field applicability of the integrated cable NDT system was verified through a field test.
        385.
        2013.09 KCI 등재 서비스 종료(열람 제한)
        The road icing forecast and snow detection system using state evaluation algorithm of multi sensor optimizes snow melting system to control spread time and amount of chemical spread application This system operates integrated of contact/non-contact sensor and infrared camera. The state evaluation algorithm of the system evaluates road freezing danger condition and snowfall condition (snowfall intensity also) using acquired data such as temperature/humidity, moisture detection and result of image signal processing from field video footage. In the field experiment, it proved excellent and reliable evaluated result of snowfall state detection rate of 89% and wet state detection rate of 94%.
        386.
        2013.09 KCI 등재 서비스 종료(열람 제한)
        In this study, performance of the post-installed anchor system was evaluated with reduced strength of concrete and anchor. One of the post-installed anchors was selected to performance evaluation. Concrete strength was reduced by freeze-thawing test, and the post-installed anchor strength was reduced by corrosion test. The post-installed Anchor was installed in concrete of freezing and thawing and original concrete, and corroded anchor was installed in original concrete only. Anchor diameter and installation depth of the anchor were the variable for each specimen. Performance of post-installed anchor system of each specimen was evaluated by pullout test. Anchor diameter and installation depth of anchor, it may affect the performance of the post-installed anchor system from the experimental test results. Fracture mode of each post-installed anchor system had occurred differently depending on the durability of concrete and anchor. The anchor pullout strength from the experimental test results was used in order to compare with the results of CCD (Concrete Capacity Design) method, and CCD equation was modified. Modified equation was able to predict the anchor pullout strength of post-installed anchor system in Original concrete and freezing and thawing of concrete.
        387.
        2013.08 KCI 등재 서비스 종료(열람 제한)
        선박 기술 발전에 따라 다양한 장비가 개발되고 있지만 인적요인에 의한 해양사고는 여전히 지속적으로 발생하고 있다. 이러한 상황에서 인적요인에 의한 사고 감소를 위하여 선교 내 항해장비의 인간공학적 설계가 많은 관심의 대상이 되고 있다. 선교에는 항해 및 통신장비로부터 나오는 음향 신호 등 항해사에게 정보를 전달하기 위한 다양한 청각 신호들이 존재한다. 하지만 이러한 청각 신호, 청각 경고음에 대한 인간의 인지능력에 관한 연구는 미흡한 실정이다. 청각 경고음은 크게 음성(speech), 함축적 소리(abstract sound), 청각 아이콘(auditory icon)으로 구분 할 수 있다. 본 연구에서는 청각 경고음 중 청각아이콘을 활용하여 5가지의 경보상황(엔진, 화재, 조타, 전기, 충돌)에서 청각아이콘에 대한 감성평가를 통해 각 상황에 적합한 청각아이콘을 선별하였다. 5가지 경보상황 중 뚜렷한 경향이 나타난 2가지 경보상황(엔진, 충돌)에 대하여 분석을 하였다. 본 연구 결과는 선교 내 청각표시장치와 통합선교알람관리시스템을 위한 기초자료로 활용될 수 있을 것으로 기대된다.
        389.
        2013.03 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 건축물의 실시간 피드백 진동제어를 위한 기초연구로써, 자체 기술력을 바탕으로 개발된 무선 가속도센서 시스템 및 프로토타입 (Prototype) AMD 시스템을 결합하여 피드백 진동제어 시스템을 구성하고, 모형 건축물을 대상으로 구성된 제어시스템의 기초성능을 평가하고자 하였다. 이를 위하여 본 논문에서는 우선 MEMS 센서 소자 및 블루투스 통신 모듈 기반의 무선 가속도 센서 유닛, 실시간 가속도 응답획득 및 제어법칙에 근거한 제어출력을 구현하도록 구성한 운영프로그램 등을 개발하였다. 또한 AC 서보모터를 이용해 기동되도록 설계한 프로토타입 AMD 및 모터 드라이버 시스템을 구성하였다. 마지막으로 이를 이용해 실시간 피드백 진동제어 시스템을 구성하였고, 2층 모형 건축물을 대상으로 실험실 규모의 진동제어 실험을 수행하여 목적된 구조물의 진동저감 효과를 정량적으로 분석하였다. 실험의 결과, 모형 구조물의 1차 및 2차 공진주파수 그리고 랜덤주파수 등의 실험조건에서 명확한 진동저감의 효과를 확인할 수 있었으며, 종국적으로 본 논문에서 개발한 무선 가속도센서 시스템 및 AMD 시스템이 향후 여타 구조물의 진동제어를 위한 효과적인 수단으로 응용될 수 있는 가능성을 확인하였다.
        390.
        2013.01 KCI 등재 서비스 종료(열람 제한)
        A food waste disposer is an electrically powered device installed under a kitchen sink. It is located between the sink’s drain and the trap which shreds food waste into tiny pieces so that they can go through plumbing. Use of this unit is convenient and hygienic for discharging food waste in kitchen. Nevertheless, this unit has been illegal until now in Korea because of both conflict with the government’s policy-resource recovery from food waste-and perceived threat to the city’s sewer system. An attempt was made recently to meet growing need to introduce this unit for advantage of using disposer and maintenance of sewer system, etc. So an attempt was made to introduce the food waste disposer system of ‘treatment type before discharging to sewer’, but it was inappropriate for conditions in Korean. In this study, we developed a suitable disposer system for Korea based on an innovative solid recovery technology. And continuous operating experiments were carried out to evaluate the performance of the system for 18 days. The amount of food waste fed into the system was equivalent to the daily amount of food waste made from 30 households living in apartment units, which was calculated to be 14.44 kg/day. After grinding, SS/TS of food waste was 60 percent and it was the maximum amount of solid that could be recovered using this system. In the system of solid collection type using screw press, more than 70 percent of suspended solids were recovered. And less than 20 percent of total soilds were discharged through wastewater and it satisfied the legal standard of Korea. This novel food waste disposer system will satisfy with both the government’s environmental policy and higher quality resource recovery from food waste in the facilities.
        391.
        2012.12 KCI 등재 서비스 종료(열람 제한)
        본 연구는 일반 X선 검사에서 CR 시스템을 이용한 환자의 근사적 피폭 선량을 평가할 수 있는 실험적 모델을 제시하고 저선량 영역에서 의료 피폭에 대한 방어의 최적화 조건으로 환자의 선량 권고량(diagnostic reference level.DRL)을 비교하고자 하였다. 이를 위하여 기준선량계와 광자극발광선량계(optically stimulated luminescencedosimeters. OSLDs)를 이용하여 관전압(kVp) 및 관전류‧노출시간의 곱(mAs)에 따른 입사표면선량(entrance surface dose. ESD)을 교차 측정하였으며 CR 시스템에서 각 노출 조건에 대한 Hounsfield unit (HU) scale을 측정하여 ESD와 HU 스케일에 대한 특성 관계를 이용하여 근사적 피폭 선량을 구하였다. 또한 임상적으로 적용 가능한지를알기 위하여 두부, 경부, 흉부, 복부, 골반부 노출 조건으로 물 팬텀에 모사하여 피폭 선량을 구하였다. 결과적으로 두선량계의 평균 ESD는 각각 2.10, 2.01, 1.13, 2.97, 1.95 mGy 이었으며 CR 영상에서 측정한 HU 스케일은 각각 3,276±3.72, 3,217±2.93, 2,768±3.13, 3,782±5.19, 2,318±4.64 이었다. 이 때 ESD와 HU 스케일에 대한 특성 관계를 이용하여 근사적으로 구한 ESD는 각각 2.16, 2.06, 1.19, 3.05, 2.07 mGy이었으며 평균 측정값과 근사적으로 구한 ESD의 오차는 3% 미만으로 영상의학 분야의 측정 오차 5%를 감안한다면 신뢰할 수 있는 오차 범위라 할 수 있었다.결론적으로 CR 시스템을 이용한 일반 X선 검사에서 환자의 피폭 선량을 근사적으로 평가할 수 있는 새로운 실험적 모델을 제시하였으며 CR 검사뿐 만 아니라 디지털 방사선촬영(digital radiography. DR) 시스템 및 필름-증감지 시스템에 적용 가능할 것으로 판단되었다.
        392.
        2012.11 서비스 종료(열람 제한)
        In this study response modification factors of rectangular reinforced concrete staggered wall system (SWS) structures were evaluated according to ATC-63. The adjusted collapse margin ratios of the model structures obtained from incremental dynamic analyses turned out to be larger than the specified limit states, which implies that the analysis model structures have enough safety margin for collapse against design level earthquakes. It also was concluded that the response modification factor, 6 used in the design of the model structures was valid.
        393.
        2012.11 서비스 종료(열람 제한)
        The purpose of this study is to develop structral technologies on the lightweight composite slab systems with sound reduction layers in the modular house. In this study, two kinds of slabs with minimum thickness was suggested reducing the floor impact sound. In order to evaluate the structural performance, the flexural strenth tests were carried out on the one-way full scale specimens. From the results of test, we know that the proposed slabs had ductile behavior and would be safe sufficiently.
        394.
        2012.04 KCI 등재 서비스 종료(열람 제한)
        오늘날 의료영상매체의 획기적인 발전으로 각 병원에서 최신 의료장비를 도입함으로써 첨단화, 디지털화로 급변하는 추세이다. 이러한 움직임에 발맞추어 방사선 종양학과에서도 CR system을 도입하여 film system의 단점을 보완하고 병원에서 사용하고 있는 Picture Archiving and Communication System(PACS)과 Electronic Medical Record(EMR) , 그리고 Radiation therapy Treatment Planning system(RTP)의 network를 원활히 하여 업무효율 증대 및환자에 대한 의료의 질 개선과 서비스 향상을 이루고자 하고 있는데, 방사선 종양학과의 Computed Radiographysystem(CR system)을 이용하여 PACS에 통합한 사례를 소개하고 그 유용성을 평가하고자 한다. 의료용 선형가속기인 MEVATRON-MX를 이용하여 현재 시행하고 있는 정도관리 중 Gantry, Collimator StarShot, Light vs. Radiation Field Accuracy, HDR QA(Dwell position accuracy)를 시행하여 PACS 상에 구현하였고 모니터 상에서 디지털 영상을 통한 QA가 가능한지 확인하였다. 또한, 현재 S병원에서 사용 중인 Operation ControlSystem(OCS)과 연동하여 치료에 필요한 코드를 각각의 치료에 부과하여 네트워크로 연결, CR상에 입력한 order가나타나도록 하였으며, Planning System인 Pinacle과 PACS상의 지원 data 오류를 해결하여 PACS 상에서도 Planning영상을 볼 수 있도록 하였다.CR system을 이용하여 L-gram, simulation image, planning image를 병원 내 어느 곳에서나 영상을 조회하고 볼 수 있게 PACS에 통합 구축되어있다. Filmless 환경에서 Dosimetry용 IP를 이용하여 Light/Radition field size 일치, gantry rotation axis의 정확성, collimator rotation axis의 정확성, brachy therapy의 Dwell position check등 QA의 시행이 가능하였다.CR system을 이용하여 방사선 종양학과에서 얻어지는 영상을 PACS에 통합함으로써 작업시간 단축과 그에 따른불필요한 인력소모의 감소 등으로 인하여 업무효율이 증대되었지만 향후 환자정보에 대한 보안을 필요로 한다.
        395.
        2012.02 서비스 종료(열람 제한)
        도로는 포장지역으로 불투수율이 높고 차량의 운행으로 인하여 비점오염물질의 축적이 큰 토지이용이다. 도로는 대부분 수계와 연관되어 강우시 처리되지 않은 비점오염물질 및 첨두유량으로 인하여 환경수리학적 문제를 야기하여 수생태계에 악영향을 미친다. 이에 미국, 유럽 및 일본을 비롯한 선진국에서는 각종 수리학적 문제를 해결하기 위하여 환경 친화적인 기술을 개발, 저영향개발 기술 (Low Impact Development) 기술을 적용함으로써 도시내 건전한 물순환 구축 및 수생태 보전을 위한 효율적인 유역관리를 하고 있다. 이러한 기술은 강우유출수의 유출을 지연시켜 개발 이전의 지역이 가지고 있던 수리학적 기능을 최대한 흉내 내는 효율적 유역관리로 도시개발사업 등에 적용되어 지고 있다. 따라서 본 연구에서는 도시지역 물순환 시스템의 왜곡 및 수생태계 복원을 위하여 저류 및 여과 기작이 적용된 도로 LID 기술을 개발하고자 수행되었으며, 현장에 적용된 1.4m×1.4m×2.0m (L×W×H) 규모의 Test-bed를 통하여 수목여과시설에 대한 평가를 실시하였다. 본 연구를 통하여 수목여과시설의 비점오염저감 능력에 대한 평가 결과, 10mm 이하의 소규모 강우에서는 대부분의 비점오염물질 항목에서 유입량 대비 70% 이상의 저감되었고, 10mm 이상의 대규모 강우의 경우 40% 이상의 저감효율을 나타내는 것으로 조사되었다. 또한 물순환 기여도 평가를 통하여 10mm 이하의 소규모 강우가 발생할 시 유입수의 73.7%가 시설 내 저류되었으며 10mm 이상의 큰 강우 발생 시에도 유입수의 30.7%가 저류되어 물순환 기여에 도움이 되는 것으로 나타났다. 따라서 본 연구의 수목여과시설이 도로에 적용시 비점오염물질의 유출 저감에 기여하여 개발과 환경이 공존될 수 있으며 도시내 물 보유를 높여 자연적인 물순환에 기여 할 수 있을 것으로 판단된다.
        396.
        2011.12 KCI 등재후보 서비스 종료(열람 제한)
        본 연구는 유치원 평가의 목적 및 방법, 평가의 영역 및 지표, 평가의 만족도 및 결과 활용에 대한 유치원 교원의 인식을 알아보는 데 목적이 있다. 이를 위하여 대전광역시에 소재한 공립유치원 교원 중 유치원 평가에 참여한 경험이 있는 교원 144명을 대상으로 질문지 조사를 실시하였다. 연구결과로 첫째, 유치원 평가의 목적은 유치원 교육과정의 질적 수준 제고가 가장 우선시 되어야 한다. 평가는 3년 주기로 실시하는 것이 적절하며, 평가의 절차는 자체평가와 현장평가로 실시되어야 하며, 유치원 평가의 활성화를 위해서는 평가 절차 및 서류의 간소화가 필요하다고 하였다. 둘째, 유치원 평가 영역 및 지표의 내용이 많고 광범위한 것은 부적절하며 평가 영역에 따른 지표의 범위 축소가 필요하다고 하였다. 또한, 국가공통지표 외에 자체지표가 필요하며, 교육과정 영역이 가장 중요하다고 하였다. 셋째, 유치원 평가제도의 만족도는 보통이라는 인식이 가장 높았다. 평가결과는 해당 유치원에게만 공개하고 평가영역별 우수 유치원의 사례를 선정하여 교육청 홈페이지에 탑재하는 것이 적절하며, 각 유치원의 교육과정 및 운영을 위한 피드백 자료로 활용되어야 한다고 하였다.
        397.
        2011.09 KCI 등재 서비스 종료(열람 제한)
        성수대교・삼풍백화점 붕괴사고 등을 계기로 유지관리 분야의 중요성이 대두되면서 1995년 시설물의안전관리에관한특별법이 제정되어 점검・진단이 실시되는 등 본격적인 유지관리체제가 시작됐다. 그러나 점검・진단의 역사가 일천한 관계로 점검・진단에 대한 기술수준이 낮았고 연구 성과 또한 미흡하여 부실 점검・진단에 대한 우려가 상존해 있었다. 이에 2002년 평가제도가 도입 되면서 부실 점검・진단 비율이 지속적으로 낮아져 왔다. 그러나 최근 점검・진단 실시결과 평가실적에 따르면 향후 부실 점검・진단비율이 더 이상 낮아지기 힘든 경향을 보이고 있다. 이를 계기로 부실 점검・진단과 관련하여 관련기관의 설문조사와 메커니즘 측면에서 고찰하므로 서, 부실 점검・진단이 초래되는 근원적인 문제점을 나열하였고, 이를 바탕으로 현행 평가제도의 개선방향을 제시 하고자 하였다.
        398.
        2011.04 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        This study was conducted to develop a portable quality evaluation system of bee-honey by near infrared spectroscopic technique. Two kinds of bee-honeys from acacia and polyflower sources were tested in this study. The system consists of power supply, tungsten-halogen lamp, detector, and optical fiber probe. Performance of the system was analyzed by comparing the prediction accuracy of the laboratory spectrophotometer. Total of 346 spectra was divided into a calibration set and a prediction set. The PLS (Partial Least Squares) models were developed to predict the quality parameters of bee-honeys. Reflectance spectra, moisture contents, ash, invert sugar, sucrose, F/G ratio, HMF(hydroxy methyl furfural), and ratio of honeys were measured. The PLS models of the laboratory spectrophotometer showed good relationships between predicted and measured quality parameters of honeys in the wavelength range of 1.100~2.200 nm. The PLS analysis of the portable quality evaluation system showed good relationships between predicted and measured quality parameters of honeys in the wavelength range of 1.100~1.300 nm and 1.400~1.700 nm. The results showed the feasibility of the portable quality evaluation system to determine the quality parameters of bee-honey in the field during harvesting.
        399.
        2010.10 KCI 등재 서비스 종료(열람 제한)
        본 연구는 무관수 옥상녹화시스템 식재기반 차이에 따른 돌나물의 생육 변화를 살펴보고, 적합한 토심과 토양배합비를 제시함으로써 무관수 옥상녹화 식물소재로 활용성을 높이고자 수행하였다. 토심(15㎝, 25cm)과 토양배합비(SL, P7P1L2, P6P2L2, P5P3L2, P4P4L2)를 각각 다르게 실험구를 조성하였으며, 내건성이 뛰어난 돌나물을 식재한 후 초장, 녹피율, 엽록소 함량, 생체중과 건조중 등 생육변화를 측정하였다. 토심 15㎝처리구에서 토양배합비에 따른 돌나물의 초장은 인공배합토가 자연토보다 높았으며, 인공배합토 중 P5P3L2에서 초장이 가장 길었다. 토심 25㎝처리구도 같은 경향을 나타내었다. 녹피율과 엽록소함량은 경우 자연토보다 인공배합토에서 대체로 높았으나, 토심에 따른 차이는 뚜렷하지 않았다. 생체중과 건물중은 토심 25cm가 토심 15cm보다 높았으며, 인공배합토가 자연토에 비해 높았다. 이상의 결과에서 무관수 옥상녹화시스템에 돌나물을 적용함에 있어, 토양배합비는 피트모스함량을 높인 인공배합토가 자연토보다는 바람하고 토심은 15cm가 토심 25cm보다 초장, 녹피율, 엽록소 함량 등 외형적인 생육상태가 양호하였다. 하지만, 토심 25cm에서는 생체중 및 건조중 등과 같이 현존량(Biomass)을 향상시킬 수 있어 조성목적에 따라 구분적용하는 것이 바람직하다. 이는 무관수 옥상녹화시스템에서 단기적인 녹피율을 높이고자 할 때 토심 15cm가 25cm보다 바람직하나, 장기적인 생육을 고려해볼 때, 토심 25cm가 15cm보다 유리함을 보여준다고 하겠다. 추후, 토양수분변화 및 각 옥상녹화시스템의 요소들과 생육요소들 간에 상관성 및 요인분석에 대한 분석이 좀 더 조사되어야 할 것으로 보인다.
        400.
        2010.09 KCI 등재 서비스 종료(열람 제한)
        This study proposes a guideline of a green roof system suitable for the local environment by verifying the growth of Zoysia japonica in a shallow, extensive, green roof system under rainfed condition. The experimental soil substrates into which excellent drought tolerance and creeping Z. japonica was planted were made with different soil thicknesses(15cm, 25cm) and soil mixing ratios(SL, P7P1L2, P6P2L2, P5P3L2, P4P4L2). The plant height, green coverage ratio, fresh weight, dry weight and chlorophyll contents of Z. japonica were investigated. For the soil thickness of 15cm, the plant height of Z. japonica was significantly as affected by the soil mixing ratio and it was shown in the order SL= P4P4L2 < P7P1L2 = P5P3L2 < P6P2L2. For the soil thickness of 25cm, the plant height was increased in order to SL < P7P1L2, P6P2L2, P5P3L2 < P4P4L2. The green coverage ratio was not observed by soil the mixing ratio or soil thickness. However, the green coverage ratio was 86∼90% with a good coverage rate overall. The chlorophyll contents of Z. japonica were not significantly affected by the soil mixing ratio in the soil thickness of 15cm, but were higher in the natural soil than in the artificial soil at 25cm soil thickness. The fresh weight and dry weight of Zoysia japonica were heavier in the 25cm thickness than in the 15cm thickness and in the artificial soil mixture than in the natural soil. The result indicated that the growth of Zoysia japonica was more effective in the 25cm soil thickness with artificial soil than in the 15cm soil thickness with natural soil in the green roof system under rainfed condition.