Reinforced concrete (RC) piloti buildings are vulnerable in the event of earthquake because the stiffness in the 1st story columns is weak to compare with the members in upper stories. In this study, seismic performances of RC piloti structures were evaluated considering with different types of floor plane layouts according to core eccentricity. With four types of floor plane layouts, five stories plioti structures were evaluated by two approaches, a nonlinear pushover analysis and a nonlinear time-history analysis. In order to improve seismic performances by satisfying the collapse prevention (CP) level, two ductile reinforcing methods by carbon fiber sheets and steel jackets were applied. Due to eccentricities in stiffness and mass with directions of plane and vertical stories, piloti structures were greatly influenced by higher order modes, so the seismic performances by the time-history analysis were significantly different from by the static pushover analysis.
This paper aims to quantify the retrofit effect of the Bolt Prefabricated Concrete-Filled Tube reinforcement method on non-seismic school reinforced concrete building through static cyclic loading experiments. To achieve the objective, two-story specimens including a non-retrofitted frame(NRF) and a Bolt Prefabricated Concrete-Filled Tube Reinforcement Frame(BCRF) were tested under static cyclic loading, and the lateral resistant capacities were compared in terms of maximum strength, initial stiffness, effective stiffness, and total energy dissipation. In addition, the load-displacement curves were compared to the story drift limit specified in Seismic Performance Evaluation and Retrofit Manual for School Facilities to investigate if the retrofitted frame was satisfied in target performance(life safety). Experimental results showed that BCRF successfully met the target performance, with a 200% increase in maximum strength and a 300% increase in energy dissipation capacity. Additionally, both initial stiffness and effective stiffness improved by more than 30% compared to NRF. Furthermore, BCRF exhibited an effect that delayed the occurrence of bond failure.
In densely populated urban areas, reinforced concrete residential buildings with an open first floor and closed upper floors are preferred to meet user demands, resulting in significant vertical stiffness irregularities. These vertical stiffness irregularities promote the development of a soft-story mechanism, leading to concentrated damage on the first floor during seismic events. To mitigate seismic damage caused by the soft-story mechanism, stiffness-based retrofit strategies are favored, and it is crucial to determine an economically optimal level of retrofitting. This study aims to establish optimal seismic retrofit strategies by evaluating the seismic losses of buildings before and after stiffness-based retrofitting. An equivalent single-degree-of-freedom model is established to describe the seismic response of a multi-degree-of-freedom model, allowing for seismic demand analysis. By convolving the seismic loss function with the hazard curve, the annual expected loss (EAL) of the building is calculated to assess the economic losses. The results show that stiffness-based retrofitting increases first-story lateral stiffness by 20-40%, enhancing structural seismic performance, but also results in a rise in EAL compared to the as-built state, indicating lower cost-effectiveness from an economic perspective. The research concludes that retrofit options that increase first-story lateral stiffness by at least 60% are more appropriate for reducing financial losses.
저층 건축물의 횡-비틀림 거동은 고차모드 효과를 증폭시킬 수 있으며, 내진성능평가 시 관련 기준은 고차모드 지배 구조물에 대해 비선형정적해석과 함께 선형동적해석을 추가로 수행하도록 규정하고 있다. 선형동적절차에는 상당한 안전계수가 적용되므로, 이는 과도한 내진보강설계로 이어질 수 있다. 이를 방지하기 위해 엔지니어들은 내진보강 시 고차모드 효과를 줄이기 위해 시행착오법을 사용해 왔다. 그러나 시행착오법에는 많은 시간과 노력이 소요되며, 결정된 보강안이 최적인지 확인하기 어렵다. 본 연구는 저층 건 축물의 수학적 모델을 수립하고 응답스펙트럼해석을 통해 고차모드 효과에 비틀림이 독립적으로 미치는 영향을 파악하였다. 이를 바탕으로 효율적인 내진보강 설계를 위해 활용될 수 있는 도표와 절차를 제시하였다. 제시된 절차를 통해 최소한의 내진보강으로 횡- 비틀림 거동하는 저층 건축물의 고차모드 효과를 효율적으로 감소시킬 수 있음을 확인하였다.
The purpose of this study is to experimentally analyze the seismic performance of a vertical irregular beam-column specimen reinforced with RBS (Replaceable Steel Brace System), a steel brace system. To evaluate the seismic performance of RBS, three specimens were manufactured and subjected to cycle loading tests. The stiffness ratio of beam-upper column of the non-retrofitted specimen was 1.2, and those of the two retrofitted specimens were 1.2 and 0.84. The stiffness ratio of the beam-lower column of all specimens was 0.36. And the stiffness ratio were used for variable. As a result of the experiment, the specimen retrofitted with RBS showed improved maximum load, effective stiffness and energy dissipation capacity compared to the non-retrofitted specimen with the same beam-upper column stiffness ratio. The specimen with 0.84 beam-upper column stiffness ratio showed improved performance compared to the specimen with 1.2 stiffness ratio.
This study proposes an economically affordable method for retrofitting non-seismic detailed roof reinforced concrete beam-column joints (BCJs). The proposed method presents an innovative arrangement of steel plates designed to delay the propagation of joint shear cracks by externally applying compressive stress to the area surrounding the BCJs. Two full-scale sub-assemblage specimens for each exterior and interior roof BCJ, i.e., control and retrofitted specimens, were subjected to reversed cyclic loading to evaluate the proposed method. The retrofitted specimens displayed a preferable ductile behavior to the corresponding control specimen, with an enhancement in lateral strength by at least 100%. Furthermore, retrofitted specimens dissipated up to 13 times more energy than the control specimen by initiating a plastic hinge on beams or columns. These results indicated the effectiveness of the proposed method in preventing joint shear failure and improving the seismic behavior of roof BCJs.
국내에서 지진 발생빈도가 증가함에 따라 다가구주택 필로티기둥의 내진보강이 필수적이다. FRP 패널은 경량성과 고강도를 갖춘 내진 보강재료 사용되고 있으나, 상대적으로 낮은 임계온도로 인해 화재에 취약하다. 따라서 FRP 패널로 보강된 RC 기둥의 내화 성능을 확보할 방안이 필요하다. 본 연구에서는 FRP 패널로 보강된 RC 기둥의 내화성능을 평가하기 위해, FRP 패널의 열적특성(비열, 열전도율, Weight loss)을 확인하는 소재시험을 진행하였다. 또한, FRP 패널로 보강된 RC 단주기둥에 뿜칠을 도포하고, 표준화재 1시간 동안의 온도거동을 분석하였다.
Steel brace is a popular option among seismic rehabilitation methods for school buildings, but it has a weakness in that the section area must be large enough to prevent buckling, so stiffness and strength are highly increased locally, and foundation reinforcing is required. On the contrary, BRB has strength that the steel core may be negligible since buckling is restrained, so the increase of stiffness and strength is insignificant, and foundation reinforcing may not be required. This study compared the effectiveness of both reinforcing methods for the seismic performance of school buildings by conducting both pushover and nonlinear dynamic analyses. Steel brace and BRB reinforcing may not be satisfied by nonlinear dynamic analysis, even by pushover analysis. This result is due to the school buildings' low lateral resistance and high column shear strength ratio. Suppose BRB can be regarded as a general rehabilitation method. In that case, BRB reinforcing is a favorable and economical option for school buildings with low column shear strength ratio since it can better satisfy performance objectives than steel brace by pushover analysis with a small steel core and no foundation reinforcing.
Many school buildings are vulnerable to earthquakes because they were built before mandatory seismic design was applied. This study uses machine learning to develop an algorithm that rapidly constructs an optimal reinforcement scheme with simple information for non-ductile reinforced concrete school buildings built according to standard design drawings in the 1980s. We utilize a decision tree (DT) model that can conservatively predict the failure type of reinforced concrete columns through machine learning that rapidly determines the failure type of reinforced concrete columns with simple information, and through this, a methodology is developed to construct an optimal reinforcement scheme for the confinement ratio (CR) for ductility enhancement and the stiffness ratio (SR) for stiffness enhancement. By examining the failure types of columns according to changes in confinement ratio and stiffness ratio, we propose a retrofit scheme for school buildings with masonry walls and present the maximum applicable stiffness ratio and the allowable range of stiffness ratio increase for the minimum and maximum values of confinement ratio. This retrofit scheme construction methodology allows for faster construction than existing analysis methods.
In this study, we propose an optimal design method by applying the Prefabricated Buckling Restrained Brace (PF-BRB) to structures with asymmetrically rigidity plan. As a result of the PF-BRB optimal design of a structure with an asymmetrically rigidity plan, it can be seen that the reduction effect of dynamic response is greater in the case of arrangement considering the asymmetric distribution of stiffness (Asym) than in the case of arrangement in the form of a symmetric distribution (Sym), especially It was confirmed that at an eccentricity rate of 20%, the total amount of reinforced PF-BRBs was also small. As a result of analyzing the dynamic response characteristics according to the change in eccentricity of the asymmetrically rigidity plan, the distribution of the reinforced PF-BRB showed that the larger the eccentricity, the greater the amount of damper distribution around the eccentric position. Additionally, when comparing the analysis models with an eccentricity rate of 20% and an eccentricity rate of 12%, the response reduction ratio of the 20% eccentricity rate was found to be large.
The purpose of this study is to experimentally analyze the seismic performance of beam-column specimens with vertical irregular, which were reinforced with RHS (Replaceable steel haunch system). a steel haunch system. To evaluate the seismic performance of the RHS, three specimens were manufactured and subjected to cycle loading tests. Retrofitted specimens have different beam-upper column stiffness ratio as a variable. The stiffness ratio of beam-upper column were considered to be 1.2 and 0.84. As a result of the test, the specimen reinforced with RHS showed improved maximum load and effective stiffness, and energy dissipation capacity compared to the non-retrofitted specimen with same beam-upper column stiffness ratio. The specimen with 0.84 beam-upper column stiffness ratio showed improved performance than the specimen with 12.
Recently, the occurrence frequency of earthquake has increased in Korea, and the interests for seismic reinforcement of existing school buildings have been raised. To this end, the seismic performance evaluations for school buildings that did not accomplish the seismic design are required. In particular, this study checks the eigenvalue analysis, pushover curves, maximum base shears, performance points and story drift ratios, and then analyzes the seismic performance characteristics according to bracing configuration of steel frame system reinforcement. Also, this study presents the practical field application methods through the comparison of analysis results for the seismic performance characteristics.
Existing reinforced concrete buildings with seismically deficient details have premature failure under earthquake loads. The fiber-reinforced polymer column jacket enhances the lateral resisting capacities with additional confining pressures. This paper aims to quantify the retrofit effect varying the confinement and stiffness-related parameters under three earthquake scenarios and establish the retrofit strategy. The retrofit effects were estimated by comparing energy demands between non-retrofitted and retrofitted conditions. The retrofit design parameters are determined considering seismic hazard levels to maximize the retrofit effects. The critical parameters of the retrofit system were determined by the confinement-related parameters at moderate and high seismic levels and the stiffness-related parameters at low seismic levels.
최근 국내에서 연간 지진 발생 횟수가 꾸준히 증가함에 따라 공공시설물에 대한 내진 보강의 필요성이 더욱 대두되고 있다. 이 연구 에서는 사각 단면을 가진 철근콘크리트 기둥에서 강봉보강의 유무에 따른 내진 성능 개선 효과를 분석하기 위해 비선형 유한요소해 석을 수행하였으며, 검증을 위해 구조실험결과와 비교하였다. 분석 결과, 이 연구에서 수행한 유한요소해석이 실제 강봉보강공법을 적용한 철근콘크리트 기둥의 구조 거동을 합리적으로 잘 묘사하는 것으로 나타났다. 또한, 해석 및 실험 모두 강봉보강공법 적용으로 인해 파괴모드가 취성파괴에서 연성파괴로 전환되었으며, 강도와 연성도 모두 증가하는 것으로 나타났다. 따라서, 강봉보강공법 적 용을 통해 기존 철근콘크리트 기둥의 내진 성능을 효과적으로 증진시킬 수 있는 것으로 판단된다. 이 연구의 주요 결과는 향후 설계 방 안 마련 등 관련 연구에 유용할 것으로 기대된다.
The purpose of this study has a purpose to evaluate shear ability, ductility and energy dissertation of specimens that is to be applied to jacket using wrapping method. The experiments was conducted as a condition that simultaneously applied axial load and transverse force. The results of experiments represent story-displacement ratio, the stiffness, energy dissertation, plastic rotation which mean seismic resistance ablity on structure. And It represents the form of crack ditribution and failure in extreme stages. Based on the results of this experiment, Design examples are given to show the performance evaluation for the column reinforcing of old school buildings using nonlinear analysis is going to be conducted. Therefore, it is possible to apply the seismic retrofit method to public facilities.
현장에 적용하는 콘크리트 강도가 증가함에 따라 초고성능 콘크리트의 적용 분야가 넓어지고 있다. 초고성능 콘크리 트에는 강섬유를 일반적으로 사용하고 있지만, 이를 대체하기 위해 다양한 섬유를 연구에 적용하고 있다. 대표적으로 슈퍼섬유 라고 알려진 아라미드 섬유가 있다. 본 연구에서는 초고성능 콘크리트의 특성이 구조물 보수보강 및 내진보강에 적용하기에 적 합하다고 판단하여, 슈퍼섬유 중 하나인 파라아리미드 섬유와 조합한 복합섬유를 혼입한 초고성능 콘크리트를 보-기둥 접합부에 내진보강재로 활용하여 특성을 분석하였다. 초고성능 콘크리트의 내진보강 효과를 확인하였으며 내진상세를 적용한 실험체와 유사한 거동을 확인하였다. 초고성능 콘크리트의 높은 강도로 인해 기존 콘크리트가 파괴되는 양상이 나타나 초고성능 콘크리 트의 보수보강 효과를 모두 발휘하지 못하고 있어 추가 연구를 통해 최적의 보강단면을 설정한다면 내진보강재료로 활용할 수 있을 것으로 판단된다.
In SRC column, the closed hoops are applied with the same detail of both 135° standard hooks to expect the same performance as hoops of RC columns. This standard detail is actually complicated to construct, thus, two separating rebars are connected in the form of a square shape and welded over the overlapping section. But this is also complicated in construction practice. Therefore, this study describes experimental results regarding cyclic behaviors shown with alternative hoops cramped by the steel clip type-binding device instead of welding and standard specimen. As a result of the experiment, the specimens with alternative hoops of the SRC column showed comparable performance to the specimens with closed hoops. Therefore, it can be evaluated that the alternative hoops applied with the rebar confinement clips in the SRC column can replace the closed hoop.
The columns of older reinforced concrete (RC) buildings generally have limited reinforcement details. Thus, they could be vulnerable to earthquake ground motions, leading to partial or complete building collapse. In this study, high-performance fiber-reinforced cementitious composite (HPFRCC) was applied to RC columns to improve their seismic behavior. Experimental tests were conducted with two full-sized specimens with limited reinforcement details, including short lap splices, while unidirectional loadings were applied to the specimens. The seismic behavior of RC columns was substantially improved by using HPFRCC.
Unlike the CFT retrofit method, The EPFT retrofit method, which fills the steel tube with engineering plastic, does not require a separate concrete forming work and is a lightweight seismic Retrofit Method. In this study, an prototype model of the EPFT was proposed, and to analyze the seismic performance, an independent specimens and a reinforced concrete column were fabricated to conduct a seismic performance test. As a result of loading test of the independent specimens, the strength was increased compared to the steel tube column without internal filling, and the ductility ratio did not significantly increase due to the falling off of the weld. As a result of loading test of the concrete reinforcement specimen, the strength, ductility ratio, and energy dissipation were increased, and the number of cracks by loading step decreased compared to the non-reinforced specimen.
This study is conducted to verify the seismic reinforcement effects of internally inserted buckling-restrained braces supported laterally by buckling-restrained rings for the seismic reinforcement of existing reinforced concrete buildings with non-seismic details. First, to evaluate the performance of KDS, the hysteretic characteristics of buckling-restrained braces are verified, and it is discovered that they satisfy the conformance criteria of the displacement-dependent damping device. Three full-scale, two-story reinforced concrete framework specimens are prepared to verify the seismic reinforcement effects, and the proposed buckling-restrained braces are bolstered with single diagonal and V-shaped braces to be compared with non-reinforced specimens. By performing a comparison with non-reinforced specimens that present intensive shear cracks at the bottom of first-floor columns, it is revealed that the maximum load and energy dissipation of specimens reinforced with the proposed buckling restrained braces, in which the structural damage extends evenly throughout the system, are approximately 4 and 6.2 times higher, respectively, which proves the effectiveness of the proposed seismic reinforcement method.