        1.
        2021.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we compare and analyze stress and vertical deflectional displacement according to cross sectional shape changes of the beam using finite element analysis. The 11,000mm long horizontal beam showed stress differences depending on the cross-sectional variation, with stress differences of up to 200MPa and at least 149MPa. The deflection at the end of the beam also differed by up to 586 mm and at least 208mm. The weight change applied according to the cross-sectional shape of the steel horizontal beam was up to 235kgf, at least 144kgf, and showed the best stress and deflection characteristics in the cross sectional shape with a weight of 185kgf. This allowed us to improve structural safety through sectional shape optimization despite the weight increase.
        4,000원
        3.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 열유도상분리법(thermally induced phase separation)을 사용하여 제조한 플라워 형태의 단면을 갖는 PVDF [poly(vinylidene fluoride)] 중공사 분리막에 대한 친수화 코팅과 그에 따른 특성평가에 대한 연구를 수행하였다. 연구에 사용한 중공사 분리막은 (주)퓨어엔비텍에서 제조한 PVDF 소재의 분리막이었으며, 친수화 코팅 실험은 PEBAX 1657, 2533, 3533의 공중합체 고분자를 사용하여 농도가 다른 용액을 제조 후 딥 코팅 방법을 이용하여 실시하였다. 친수화 코팅이 된 중공사 분리막은 친수화 정도를 파악하기 위하여 SEM 촬영 및 접촉각 측정을 실시하였다. SEM 촬영 결과 코팅의 농도가 증가하고 코팅횟수가 증가할수록 코팅층의 두께가 두꺼워짐을 확인하였고, 접촉각 측정의 경우 코팅의 농도가 증가하고 코팅횟수가 증가할수록 접촉각이 낮아짐을 확인하였다. 기체 투과 실험 결과 코팅농도가 증가하고 코팅횟수가 증가할수록 산소 기체투과량이 감소하였으며 친수성이 높은 PEBAX 1657로 코팅한 중공사의 기체투과량이 PEBAX 2533과 3533으로 코팅된 중공사보다 낮은 기체투과량을 가짐을 확인하였다.
        4,800원
        6.
        2017.10 구독 인증기관·개인회원 무료
        강한 수압에 의한 열화 콘크리트의 제거는 일반적으로 이루어지는 표면처리 방법으로 장비의 수압, 유량, 이동속도에 따라 제거 정도가 달라지며 표면에 생긴 요철은 보수재료의 부착성능에 영향을 주고 현장 부착강도 시험에서 천공 깊이를 결정 하는데 필수적으로 파악해야 하는 정보이다. 그러나 요철이 어떠한 특성을 가지고 있는지에 대한 데이터는 부족한 실정으로 보수 방법에 따른 보수 깊이, 요철 깊이는 어떠한 분포를 가지는지, 열화 제거에 따라 변동성은 얼마만큼 커지는지는 알 수 없는 실정이다. 본 연구는 고속도로 교면포장 개량과 콘크리트 포장 부분단면 보수를 실시하는 경우 발생하는 요철의 특성을 조사하였다. 이를 위해 5개 내외의 코어를 채취하여 최대 및 최소 길이를 측정하고 평균값을 보수재 깊이로 계산하였으며 차이를 요철 깊이로 정의하였다. 최대 요철깊이는 코어채취 위치에 따라 최대 나타내거나 최소를 나타낼 수 있는데 굵은 골재 최대치수 보다 큰 약 68mm직경 코어를 채취하여 표면 요철 변화가 코어 내에서 모두 관찰되게 하였다. 또한 보수재 요철깊이가 표면처리 방법에 따라 다른 형태로 나타내는지 비교하기 위해 교면포장과 부분단면 보수를 구분하여 분석하였다. 교면포장 두께 및 요철의 경향을 분석하기 위해 약 410개 현장 부착강도 코어 파괴 면을 조사하였다. 보수두께는 중앙 보다 열화가 심한 단부에서 변동이 심하게 발생하므로 단부에서 일정 거리를 떨어뜨려 코어를 채취하여 위치 변동성을 최소화 한 상태로 시공과 열화에 따른 두께 및 요철 변동성을 알아보고자 하였다. 또한, 부분단면보수 요철 분석을 위해 약 360개 현장 부착강도 시편 파괴면 분석결과 데이터를 조사하였다. 부분단면보수는 교면포장과 달리 파손이 발생한 줄눈에만 표면처리를 수행하므로 장비의 가동이 불연속이고 열화 제거가 교면포장 보다 소형 장비를 사용하여 수행하기 때문에 나타나는 특징을 비교하였다. 콘크리트 포장 및 교면포장에 덧씌우기 하거나 부분단면 보수를 수행하는 경우 발생하는 요철의 특성을 조사한 결과 교면포장의 보수두께는 8∼9cm에서 가장 큰 빈도를 나타내고 요철깊이는 0.8∼1.0cm 범위에서 가장 큰 빈도를 나타내었다. 부분단면 보수깊이는 5∼6cm 범위에서 가장 큰 빈도를 나타내고 요철깊이는 0.4∼0.6cm 범위에서 가장 큰 빈도를 가지는 것으로 나타났다. 보수재 두께 변화는 교면포장이 부분단면보수에 비해서 평균적으로 크게(1.0/0.6cm) 나타났고 요철깊이도 평균적으로 더 깊은(0.9/0.6cm) 경향을 나타냈다.
        7.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the present study, FE analysis was performed for characterising structural strength of a seat frame w.r.t. varying sectional shapes as well as different materials of the seat back frame based on the FMVSS 207 regulation in order to obtain the design outline of a lightweight seat frane structure. Four types of materials, i.e., SAPH440, Al7021, Al6082 and carbon/epoxy composites were applied to the seat back frame type beams and their bending behaviours were compared by three point bending FE analysis. Consequently, the lightweight structure of seat back frame with the equivalent strength characteristics of conventional frame was suggested.
        4,000원
        8.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The water removal characteristics in a PEMFC trapezoidal gas channel are investigated with the volume of fluid (VOF) method. For the case of wall contact angle of 60 degree, liquid water attaches on the top wall and moves toward the exit. In contrast, liquid water moves along the channel side corner or GDL surface irregularly for the higher wall contact angles. The hydrophillic wall contact angle of 60 degrees provides more favorable diffusion of reactants to cathode reaction sites as the GDL surface water coverage ratio approaches zero even if the water flow rate increases.
        4,000원
        9.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 Co-Rotational plane beam transient analysis EDISON program(CR-보)를 이용한 에어포일 단면형상 변화 에 따른 진동특성 연구를 수행하였다. Co-Rotational 평면 보 해석은 대 회전과 작은 변형률을 갖는 보 해석에 적합하다. 항 공기의 날개를 외팔보로 가정하여, VABS를 통한 단면해석과 Fourier 변환을 통해 각 단면형상 변화에 따른 에어포일의 고 유진동수를 비교하였다. VABS를 사용하여 단면의 형상과 재료의 적층 정보를 고려한 단면에서의 유한요소 해석을 수행하 였다. 에어포일의 재질, spar 유무, 단일 등방성 재료·복합재료, 에어포일 최대두께의 변화에 따라 에어포일의 끝단 진폭과 고유진동수가 변화함을 확인할 수 있었다. 이를 바탕으로 에어포일 고유진동수 변화는 2차 관성모멘트/단면적, 밀도, 영률의 변화에 상당한 영향을 받음을 알 수 있었다.
        4,000원
        10.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The present study analyzes the flexure behavior of the circular CFT member through experiment and numerical analysis. Through comparison between experimental and numerical results, whether or not the member was a full composite have little effect on the behavior. There circular CFT’s flexure behavior when considering pure moment is almost similar regardless of the interface characteristics between the steel and concrete. This is because there is no difference in the neutral axis of the full-composite and non-composite circular CFT member.
        4,000원
        11.
        2015.11 구독 인증기관 무료, 개인회원 유료
        The volume of fluid (VOF) method is applied to study the effects of the gas channel cross-section shape on the removal characteristics of a water slug in a trapezoidal PEMFC gas channel. Two different open angles 50 and 60 degrees are selected to investigate the effect of cross-section shape on the behavior of a liquid water slug. In comparison to the 50 degrees case, the water slug is removed slightly faster for the 60 degrees case.
        3,000원
        12.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The circular hollow section is usually used for member of main frame to carry the external load in single layer lattice dome. But, the H-shaped section may be used for member of main frame since it is convenient for attaching roof panels. Single layer lattice domes have various buckling characteristics, such as the overall buckling, the member buckling, and nodal buckling. The purpose of this study is to compare buckling characteristics of single-layer lattice domes in which the H-shaped steel section as the existing domestically-produced structural steel is used as main frames to those of domes in which a circular hollow section is used as main frames.
        4,000원
        13.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A series of wind tunnel tests were conducted on 7 super-tall buildings with various polygon cross-sections, including triangle, square, pentagon, hexagon, octagon, dodecagon, and circular. The primary purpose of the present study is to investigate the effect of increasing number of sides on aerodynamic characteristics for super-tall buildings. Wind tunnel tests were conducted under the turbulent boundary layers whose power-law exponent is 0.27. Fluctuating wind pressures from more than 200 pressure taps were recorded simultaneously, and time series of overturning moments were calculated considering tributary area of each pressure tap. The results show that the overturning moment coefficients and the spectral values decrease with increasing number of sides, and the largest mean and fluctuating overturning moments were found for the triangular super-tall building, and the largest spectral values were found for the square super-tall building. The analysis should be conducted more in detail, but currently it can be roughly said that there seems to be a little differences in the aerodynamic characteristics for the super-tall buildings whose number of sides is larger than 5 or 6.
        4,000원
        14.
        2012.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        고속도로에서 재령이 20년이 넘는 노후 콘크리트가 늘어남에 따라 콘크리트 포장의 보수/보강이 중요한 이슈로 대두되고 있다. 노후 콘크리트 포장의 보강 대안으로서 아스팔트 덧씌우기가 많이 사용되고 있으나 반사균열 및 포트홀 등 체류수로 인한 문제가 심각하게 대두되고 있다. 본 연구는 반사균열 및 체류수의 문제를 최소화하기 위해 고안된 접착식 방수층을 소개하였으며 포장가속시험을 통해 일반 택코팅을 적용한 합성단면포장과 비교평가를 실시하였다. 실험은 강우를 모사하기 위해 물을 뿌리면서 진행하였고 덧씌우기 포장체의 거동 및 수분 저항 특성을 분석하였다. 연구결과 접착식 방수층은 아스팔트 포장과 콘크리트 포장이 일체로 거동하는 것을 도와주기 때문에 아스팔트 포장체에 발생하는 거동이 일반 택코팅 구간과 완전히 다른 것으로 나타났다. 또 수분의 유입을 최소화하므로 결과적으로 반사균열의 발생을 약 70% 지연시키는 것으로 나타났으며, 체류수로 인한 손상도 줄여주는 것으로 나타났다.
        4,000원
        15.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 하부박스형상을 변화시킨 단일 박스거더단면에 대하여 변장비 1:51:10의 범위에서 풍동실험을 통하여 동적응답특성을 고찰하였다. 거더의 단면형상변화는 직사각형 1종류와 사다리꼴 단면 2종류를 선정하였다. 실험결과를 정리하면, 와류진동의 경우, 변장비 1:5에서는 전반적으로 직사각형거더에 비하여 사다리꼴 거더단면의 연직 및 비틀림 최대진폭이 감소하는 경향을 알 수 있으며 1:7.5의 경우는 미소하나마 직사각형단면의 와류진동응답이 사다리꼴 단면에 비하여 안정적인 응답을 보였다. 갤로핑은 변장비 1:5단면중에서 사다리꼴 단면(B050-1단면)의 (+)영각 범위에서만 발생하였고 그 이외의 모든 단면에서는 발생하지 않았다. 비틀림 플러터는 1:5 및 1:10단면 의 (+)영각범위에서 발생하였고 단면형상변화에 따른 한계풍속의 변화는 두드러지지 않았다. 또, 변장비 증가에 따라 와류진동의 발생은 (+)영각범위로 제한되고 최대진폭도 감소하는 추세를 보였으며 발산진동의 한계풍속도 증가하는 경향을 보였다. 하부박스거더의 형상변화에 따른 응답변화는 변장비가 증가할수록 그 차이가 작아지는 경향을 보였다.
        4,000원
        16.
        2011.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        유속의 변화에 따른 오일펜스 만곡부 후면의 속도장과 압력장, 와도 및 난류 강도를 계측한 PIV 실험의 결과 유속이 증가함에 따라 유동 경계역의 후면부에서의 흐름 방향이 전면부의 흐름 방향에 가까워지는 현상이 나타났고, 압력 분포의 양상이 달라졌으며 난류도 더욱 불규칙적인 형태로 나타났다. PIV 실험과 동일 조건으로 수행한 CFD 해석 결과, 후류의 유동 패턴이 0.3m/s이하의 저속인 경우는 PIV 실험 결과와 유사하게 나타났으나, 유속이 0.4m/s일 때는 오일펜스 자체의 유연성으로 인해 다소 차이가 나타났고, 오일펜스 하단의 압력차로 인한 불규칙한 난류가 수면까지 영향을 주었다.
        4,000원
        17.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 변장비 B/D=5인 박스거더의 기본단면을 대상으로 브래킷부의 길이변화에 따른 동적 풍응답 특성을 풍동실험을 통하여 고찰하였다. 박스거더의 단면형식은 단일박스, 2박스 및 3박스 단면의 3종류로 하였으며 - 5°~+5°의 영각범위에서 응답측정을 수행하였다. 풍동실험 결과로서 연직와류진동은 (+) 또는 (-)방향으로 영각이 증가 할수록 최대진폭이 증가하였으며 비틀림 와류진동의 경우는 브래킷의 길이 및 하부박스의 개수의 변화에 따라 다양한 응답변화를 보였다. 플러터 한계풍속은 전반적으로 영각이 (+)방향으로 증가함에 따라 감소하는 경향이 나타났으며, 브래킷길이가 증가할수록 다소의 차이는 있지만 한계풍속이 감소하였다.
        4,000원
        18.
        2010.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        RC교량의 내진성능은 교각에 충분한 연성도를 제공함으로써 확보할 수 있다. 이러한 연성도는 교각의 소성힌지 영역에 적절한 횡방향철근을 배근함으로써 실현할 수 있다. 횡방향철근에 의한 횡구속력은 유효구속력으로 결정되므로 단면형상과 횡방향철근량이 지배적인 요소가 된다. 동일한 횡방향철근량을 제공하더라도 설치간격, 배치형태, 갈고리 상세 등의 차이에 의해 유효구속력에 차이가 있게 된다. 후프띠철근에 의해 횡구속력을 발휘하는 원형단면과는 달리 사각 또는 중공사각단면에서는 유효구속력을 증가시키기 위해 보강띠철근이 함께 사용된다. 이러한 보강띠철근을 어떻게 고려하느냐에 따라 횡구속된 콘크리트의 응력-변형률 관계는 달라지게 된다. 본 연구에서는 실험을 통해 후프띠철근과 함께 보강띠철근을 갖는 정사각단면 콘크리트의 응력-변형률 관계를 파악하였으며 기존의 평가식과 비교를 통해 역학적 특성을 분석하였다.
        4,000원
        19.
        2010.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        횡하중을 받는 RC 기둥의 전단강도는 기둥의 변위연성도가 증가함에 따라 감소하는 것으로 알려져 있다. 연성도의 증가에 따른 전단강도의 감소율은 초기전단강도에 따라 크게 좌우되므로 이를 합리적으로 예측하기 위해서는 초기전단강도의 평가가 매우 중요하다. 기둥의 전단거동은 단면모양, 형상비, 축력, 축방향철근비, 연성도 등 다양한 요인에 의하여 영향을 받아 복잡하다. 본 연구에서는 형상비, 단면의 중공비, 축방향철근비, 중공 및 중실단면을 변수로 하는 시험체를 제작하여 실험적 연구를 수행하여 전단거동특성을 살펴보았다. 또한, 축방향철근이 전단강도에 미치는 영향을 분석하여 형상비와 축력을 고려한 기존의 초기전단평가식을 보완하였으며, 그 타당성을 검증하였다.
        4,000원
        20.
        2010.04 구독 인증기관 무료, 개인회원 유료
        유속의 변화에 따른 오일펜스 만곡부 후면의 속도장과 압력장, 와도 및 난류 강도를 계측한 PIV 실험의 결과 유속이 증가함에 따라 유동 경계역의 후면부에서의 흐름 방향이 전면부의 흐름방향에 가까워지는 현상이 나타났고, 압력 분포의 양상이 달라졌으며 난류도 더욱 불규 칙적인 형태로 나타났다. PIV 실험과 동일 조건으로 수행한 CFD 해석 결과, 후류의 유동 패턴이 0.3m/s이하의 저속인 경우는 PIV 실험 결과 와 유사하게 나타났으나, 유속이 0.4m/s일 때는 오일펜스 자체의 유연성으로 인해 다소 차이가 나타났고, 오일펜스 하단의 압력차로 인한 불규 칙한 난류가 수면까지 영향을 주는 것 같았다.
        4,000원