검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 86

        1.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study focused on using indirect filtration through riverbeds to produce high-quality drinking water. Data on water quality from a water intake facility(capacity 10,000 m3/day) and nearby rivers were collected over a three-year period. The average intake facility specifications were found to be a specific surface area of 58 balls/m2, a mean particle size of 24 mm, an inflow velocity of 2.2 cm/sec, and a burial depth of 5 m. The water quality improvement rate was assessed as grade Ia, surpassing the adjacent river’s water quality. Correlation analysis showed a weak correlation between opening ratio, Suspended Solid (SS), and Biochemical Oxygen Demand (BOD) compared to total coliforms and fecal coliforms. The correlation coefficient R value of SS was -0.614, BOD was –0.588, total coliforms -0.870, and fecal coliforms -0.958. The R value shows a negative value, which showed that the larger the opening rate, the lower the removal rate of water pollutants. The correlation coefficient R values according to the depth of burial were found to be BOD 0.914, SS-0.124, total coliforms 1.000, and fecal coliforms 0.866. The deeper the burial depth, the higher the removal rate of BOD and microbial groups.
        4,000원
        2.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        부남호는 하굿둑 건설 이후 수질이 급격히 악화되어 농업용수로 사용이 불가할 만큼 본래의 기능을 상실하였다. 따라서 해수 교환이나 유통의 필요성이 있으나, 극히 오염된 부남호의 물을 대량 방류할 시 문제가 야기될 수 있기 때문에 시기에 따른 환경 조사가 중요하다. 따라서 본 연구에서는 갈수기 (4월)와 강우기 (7월)에 천수만과 부 남호의 수질 및 식물플랑크톤 분포 특성을 조사하였다. 갈수기에는 부유 생물이 정체되어 부남호 내에서 남조류 Oscillatoria spp. 세포수가 8.92×107 cells L-1로 대증식하였 고, Nitrate+Nitrite을 제외한 영양염 대부분이 소비되었다. 강우기에는 담수 유입의 영향으로 부남호에서 용존 영양염이 크게 증가하였고 부남호에서 식물플랑크톤이 대증식 하였다. 강우기 방류의 영향으로 천수만 내측 역시 높은 농도의 생물량을 보였다. 강우기 부남호에서 우점했던 남조류 Oscillatoria spp.와 Microcystis spp.가 천수만 내측에서도 다수 출현하였으며, 해수에서는 Cheatoceros spp., Eucampia zodiacus와 같은 규조류가 빠르게 증식하였다. 부영양화 지수는 부남호 내측에서 1을 초과하여 부영양 해역으로 평가되었다. 천수만은 강우기에 담수 방류의 영향을 받을 경우 부영양화 해역으로 평가되었다. 특히 부남호 내 방조제에 인접한 B3 정점의 8 m 이상 수심에서 정체된 해수 기원의 강한 빈산소 수괴가 관찰되었고, Nitrate+Nitrite를 제외한 영양염 농도가 극단적으로 높았다. 특히 COD 농도가 206 mg L-1로 심하게 오염된 상태임을 확인하였다. 따라서 부남호는 지속적으로 육상기원의 영양염이 누적되며, 식물플랑크톤의 대발생과 침강으로 수질이 더욱 악화될 가능성이 높은 수역으로 판단되었고, 이를 근본적으로 해결하기 위해서는 해수유통을 통한 생태계 복원이 필수적이다.
        4,200원
        4.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        축산 폐수는 고농도의 영양염류와 중금속을 함유하고 있어, 배출될 때 수질을 악화시킨다. 기존 처리 기술과 비교하여 bioremediation은 축산 폐수 처리에 유능하다. 특히, 미세조류는 오염물질 제거에 잠재력을 가지고 있다. 본 연구에서는 Ankistrodesmus bibraianus를 이용하여 축산 폐수 내 영양염류 (질소 (N), 인 (P))와 중금속 (구리 (Cu), 아연 (Zn))의 제거 가능성을 평가하고, A. bibraianus의 최적배양조건을 확립하였다. 연구결과, 최적 배양조건은 28°C, pH 7, 광주기는 14 : 10 h로 설정되었다. N과 P의 단일 처리구 (500, 1,000, 5,000, 10,000 mg L-1)에서 제거효율은 각각 22.9~80.6%와 11.9~50.0%였다. 또한, N과 P의 복합 처리구에서 제거효율은 각각 16.4~58.3%와 7.80~49.8%였다. Cu와 Zn의 단일 처리구 (10, 30, 50 mg L-1)에서 제거효율은 각각 15.5~81.5%와 6.28~34.3%였다. 유사하게, Cu와 Zn의 복합 처리구에서 제거효율은 각각 16.7~74.5%와 5.58~27.5%였다. 또한 영양염류 (N 및 P)와 중금속 (Cu 및 Zn)의 성장 및 제거효율을 축산 폐수에 적용할 수 있음을 나타냈다. 본 연구의 결과에 따르면 A. bibraianus는 축산 폐수 내 영양염류와 중금속 제거에 이용할 수 있을 것으로 사료된다.
        4,200원
        5.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objectives of this study were to analyze the influence of chemical water quality on fish guilds, pollution tolerance and the multi-metric ecological health, based on the Fish Assessment Index (FAI) in the main stream of Mangyeong River between 2009−2016. The quality of water with specific conductivity, TP, and NH4-N got worse dramatically in the down region. During the study, a total of 50 species were collected and the most dominant species was Zacco platypus. Also known as tolerant species, accounted 22.9% of the total abundances, thus indicating a trophic degradation. The downstream region (S5) had the highest number of fish external abnormalities, indicating a degradation of ecological health, based on the fish assemblages. Pearson correlation analysis indicated that relative abundance of tolerant fish species and omnivore fish species had a significant positive correlation (r>0.30, p<0.05) with values of BOD, conductivity and NH4-N. Whereas, the relative abundance of the sensitive species and insectivore species had a significant negative relations (r<−0.30, p<0.001) with the parameters. The mean obtained from the multi-metric fish model, based on the FAI of all sites was 47 (n=40). This indicated a “fair condition” in the ecological health, and the downstream regions (S3−S5) were judged as “bad condition”, indicating an influence of the chemical degradation on the ecological health.
        4,200원
        6.
        2018.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the effects of operating conditions on the formation of reversible and irreversible fouling were investigated in the filtration using ceramic membrane for water treatment process. The effect of coagulation pretreatment on fouling formation was also evaluated by comparing the performance of membrane filtration both with and without addition of coagulant. A resistance-in-series-model was applied for the analysis of membrane fouling. Total resistance (RT) and internal fouling resistance (Rf) increased in the membrane filtration process without coagulation as membrane flux and feed water concentrations increased. Internal fouling resistance, which was not recovered by physical cleaning, was more than 70% of the total resistance at the range of the membrane flux more than 5 m3/m2・day. In the combined process with coagulation, the cake layer resistance (Rc) increased to about 30-80% of total resistance. As the cake layer formed by coagulation floc was easily removed by physical cleaning, the recovery rate by physical cleaning was 54~90%. It was confirmed from the results that the combined process was more efficient to recover the filtration performance by physical cleaning due to higher formation ratio of reversible fouling, resulted in the mitigation of the frequency of chemical cleaning.
        4,200원
        8.
        2017.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to provide basic data for establishing water pollution prevention for effluent water from soil and stone quarries and downstream river water by investigating waste water and sewage water processing, as well as the state of legislation related to grit chamber installation and water quality analysis. The pH and DO, BOD, T-P, Total coilform of effluent water and stream water showed higher than Ⅲ class but COD and SS, T-N showed less than Ⅲ class. In addition, concentration of BOD and COD, Turbidity were increased following deepened rainfall intensity. And therefore we devise systematic reduction facility and remedy for prevention of water pollution.
        4,000원
        9.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we investigated influent and effluent water pollutants in 53 Public Sewage Treatment Works (PSTWs) where industrial wastewater or landfill leachate is combined four times for two years from 2014 to 2015. Also, we analyzed the characteristics of heavy metals and volatile organic carbons at influent and effluent of these PSTWs caused by sewage treatment combined with industrial wastewater or landfill leachate. As a result, six heavy metals such as barium, copper, iron, manganese, nickel and zinc, and four volatile organic carbons (VOCs) including phenols, di(2-)ethylhexyl phthalate (DEHP), formaldehyde and toluene were observed above detection limits in most of PSTWs. Also, it was revealed that six heavy metals such as hexavalent chromium, mercury, cadmium, chromium, nickel and selenium, and four VOCs including 1,1-dichloroethylene, vinyl chloride, naphthalene, and epichlorohydrin were observed more frequently according to precipitation. As a result of reviewing the monitoring data on “Water Quality Monitoring Networks” in lower watersheds of PSTWs, both heavy metals and VOCs were below detection limits, indicating that the effluent water had little influence on the watershed. Nevertheless for the better management of influent and effluent pollutants in PSTWs, it is necessary to establish the advanced management plans for water pollutants in PSTWs, which include a list of priority substances management, monitoring plans, and guidelines for industrial wastewater and landfill leachate combined in PSTWs.
        4,000원
        10.
        2016.11 구독 인증기관 무료, 개인회원 유료
        2015년 6월부터 2016년 10월까지 목포내항 5개 정점에서 표층수와 저층수 수질인자 중 COD, DO, DIP, DIN, 투명도, Chl-a를 조사하여 신구 해양환경기준치와 구 해양환경기준치를 비교하여 수질오염도를 평가하고자 하였다. 조사결과, 개정된 환경 기준치에 의한 평가결과 Ⅱ- Ⅴ 등급, 구 환경 기준치에 의한 평가결과는 Ⅰ- Ⅱ 등급을 보였다.
        3,000원
        11.
        2016.11 구독 인증기관·개인회원 무료
        물은 신체의 대부분을 구성하고 있는 기본 물질로서 생명유지의 필수 요소이다. 특히 WHO에서는 인류 건강유지의 1등 공신으로 깨끗한 물공급을 꼽고 있다. 우리나라는 산업화, 도심화를 통해 신규오염물질 발생이 증가하고 있으며 특히 먹는물의 경우 중금속 및 소독부산물 중심의 관리에서 난연제, 코팅제, 의 약물질 등 신규오염물질 관리에 주력하고 있다. 우리나라 먹는물 수질기준은 1963년 최초 도입된 이래 1984년, 1986년 개정 강화되었으며, 1995년 먹는물 관리법이 제정되었고 1997년 감시항목이 설정되 어 기준과 감시의 2원화된 관리체계가 유지되고 있다. 먹는물 수질기준은 외국 사례 도입방식에서 체계적 장기 모니터링을 통한 위해도 평가를 수행하여 기준을 강화하고 있으며 현재 60개 항목으로 확대 강화되었다.
        13.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study have been conducted to analyze the feasibility of establishing Contamination Warning System(CWS) that is capable of monitoring early natural or intentional water quality accidents, and providing active and quick responses for domestic C_water supply system. In order to evaluate the water quality data set, pH, turbidity and free residual chlorine concentration data were collected and each statistical value(mean, variation, range) was calculated, then the seasonal variability of those were analyzed using the independent t-test. From the results of analyzing the distribution of outliers in the measurement data using a high-pass filter, it could be confirmed that a lot of lower outliers appeared due to data missing. In addition, linear filter model based on autoregressive model(AR(1) and AR(2)) was applied for the state estimation of each water quality data set. From the results of analyzing the variability of the autocorrelation coefficient structure according to the change of window size(6hours~48hours), at least the window size longer than 12hours should be necessary for estimating the state of water quality data satisfactorily.
        4,200원
        15.
        2011.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 해역의 수질오염 특성을 알아보기 위해서 2010년 2, 5, 8, 11월에 광양만 20개 정점과 진해만 23개 정점에서 COD (화학적산소요구량, Chemical Oxygen Demand), Chlorophyll a, 대장균 Escherichia coli를 조사하였다. 또한, 광양만과 진해만의 지형학적특성을 고려하여 각각 3개 구역, 4개 구역으로 나누어 평가하였다. 광양만의 COD농도는 춘계 (평균: 4.3 mg L-1))에 가장 높
        4,000원
        16.
        2009.02 구독 인증기관 무료, 개인회원 유료
        Total water pollution load management(TWPLM) seeks to harmonize conservation and development by allowing regional developments to be carried out in an eco-friendly manner and within the scope of achieving the desirable water quality. Water pollutant sources are managed so as to keep the total amount of pollutants in public watersheds within a certain level or total allowance in accordance with target water quality goal. With relation to the basic guideline under the Special Act on the Water Resources Management and Community Support for Watersheds, the load from the land should be determined by the classification of rainy and dried season respectively. Objective loads of abatement applied in the 1st planning period(2004∼2010) are set up standards by low flow condition(Q275) without considering the change of flow, while allowable wasteloads are estimated by the criteria of daily mean precipitation 10 mm, as critical standard for the division of surface runoff load. Even though the standard flow conditions to meet the goal of water quality at the end of unit watershed are low flow, but it might be considered to set up drought flow condition(Q355) for the improvement of water quality. Also the objective loads for abatement to meet the target water quality should be calculated without the effect of non-point sources from the land.
        4,000원
        18.
        2006.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        2004년 강수량이 많았던 8월 목포 주변해역의 8개 지점에서 COD를 조사한 결과, 북항 앞바다에서 6.80 ppm, 영산강 하구둑 부근 해역에서 4.42 ppm, 신안비치 호텔 앞 해역에서 4.60 ppm으로 나타나 해양환경 기준치의 3등급을 초과하고 있었고 나머지 지점에서는 2-3등급 수준을 보였다. 총질소 농도는 1.23-3.56 ppm으로 전 지점에서 3등급 이상이었고, 총인의 농도는 0.07-0.12 ppm으로 2-3등급의 수질을 보였다. 이와 같은 수질은 수산생물의 서식, 양식 및 해수욕 등의 해양레저 활동을 하기에 부적합하며 공업용수와 선박의 정박 등에 이용 할 수 있는 수질 상태를 보였다. 육상으로부터의 목포 내항으로 유입되는 12개 지점의 점원 유입 부하량과 그 기여율을 조사한 결과, 전체 유입양 중 영산강으로부터 유입되는 총질소의 양이 70-93 %, 총인의 유입량도 31-91%를 차지하고 있어 목포 내항의 수질개선을 위해서는 영산강의 수질개선이 급선무이며, 다음으로 북항 하수처리장, 임암천, 남해 하수처리장 순으로 방류수 중의 질소와 인을 우선적으로 제어해야 될 것으로 판단되었다.
        4,200원
        1 2 3 4 5