검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 28

        1.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to analyze the effects of sewerage facilities through I/I analysis by rainfall by selecting areas where storm overflow diverging chamber is remained due to the non-maintenance drainage equipment when the sewerage system was reconstructed as a separate sewer system. Research has shown that wet weather flow(WWF) increased from 106.2% to 154.8% compared to dry weather flow(DWF) in intercepting sewers, and that the WWF increased from 122.4% to 257.6% in comparison to DWF in storm overflow diverging chamber. As a result, owing to storm overflow diverging chamber of partially separate sewer system with untreated tributary of sewage treatment plant, rainfall-derived infiltration/inflow(RDII) has been analyzed 2.7 times higher than the areas without storm overflow diverging chamber. Meanwhile, infiltration quantity of this study area was relatively higher than that of other study areas. Therefore, it is necessary to reduce infiltration quantity through sewer pipe maintenance nearby river. Drainage equipment maintenance should be performed not to operate storm overflow diverging chamber in order to handle the appropriate sewage treatment plant capacity for rainfall because it is also expected that RDII due to rain will occur after maintenance. In conclusion, it is necessary to recognize aRDII(allowance of rainfall-derived infiltration/inflow) and to be reflected it on sewage treatment plant capacity because aRDII can occur even after maintenance to the complete separate sewer system.
        4,600원
        2.
        2018.11 구독 인증기관·개인회원 무료
        본 사례는 최근 준공된 “구미하수처리장 하수처리수를 이용한 재이용시설”에 대한 것으로 이 시설은 구미하수처리장의 2차 처리수를 원수로, 응집침전시설, 전처리시설, 주처리시설과 재이용수 공급시설로 구성되어 있으며, 설비의 성능 확인을 위한 시운전을 완료하였다. 주처리시설로는 역삼투막(RO Membrane)을 적용하였으며, 하수처리수 내 잔류물질로 인한 역삼투막 성능저하방지와 수요처의 요구수질 충족을 위해 활성탄 주입을 포함한 응집침전공정과 정밀여과막(Micro Filter)을 전처리시설로 구성하였다. 사업 초기단계에 현재 시공된 것과 동일한 공정으로 구성된 Pilot Plant를 건설, 운영하여, 반영된 각 단계별 공정의 적정성과 주요 설계 인자를 확인하였으며, 일부 확인된 개선 사항은 실시설계시 반영하였다.
        3.
        2018.11 구독 인증기관·개인회원 무료
        인구구조 및 생활방식 등의 변화로 물 소비는 증가되고 있는 반면, 가뭄 등 기후변화로 가용수자원 여건은 악화되고 있어 안정적인 용수공급의 필요성이 증대되고 있다. 우리 정부는 물의 재이용 촉진 및 지원에 관한 법률을 제정하고 하수처리수 재이용, 중수도, 빗물이용 등 지속가능한 물 순환을 추진하며 지역적 물 부족을 해소하기 위하여 노력하고 있다. 정부는 물 재이용 관리체제를 강화하고 시설기반을 구축하는 한편 관련 산업 육성과 전문인력 양성을 위해 노력해 왔다. 하지만 국내 물 재이용은 여러 가지 정책⋅재정⋅기술적 한계로 인해 계획대비 더디게 진행되고 있어 물 재이용 방향성의 재정립이 필요하다. 이에 본 발표를 통해 물재이용의 방향에 대하여 하수처리수 재이용을 중심으로 제언하고자 한다.
        4.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        하수처리 혐기성 유동상 생물반응기(Anaerobic Fluidized Bed Bioreactor : AFBR)는 높은 표면적을 갖는 입상활 성탄을 유동 메디아로 적용함으로써 생물막 형성 및 유지에 유리하며 이로 인해 우수한 유기물 제거 효율을 나타내나 처리된 유출수 내의 질소와 같은 영양염류의 잔존이 여전히 문제로 남아있다. 본 연구에서는 AFBR에 의해 처리된 유출수 내의 질소 배제를 위하여 정삼투막(FO membrane)을 유도용액의 종류와 농도에 따라 적용하였다. 실험결과 유출수의 총질소 배제 효율 은 FO막에 적용하는 유도용액(draw solution : DS)의 종류 및 농도에 크게 의존하였다. 유도용액 농도가 증가함에 따라 FO막의 수투과량이 증가하였으며, 1 M의 NaCl을 유도용액으로 사용한 경우 총질소 배제 효율은 55%이었으나 1 M의 glucose를 유도용액을 사용한 경우 거의 완벽한 총질소 배제 효율을 나타내었다. AFBR 유출수를 FO막으로 24시간 동안 여과를 진행하 였으나 파울링에 의한 수투과량의 감소는 관찰되지 않았다.
        4,000원
        5.
        2018.05 구독 인증기관·개인회원 무료
        The Anaerobic fluidized bed bioreactor (AFBR) treating synthetic wastewater to simulate domestic sewage was operated under GAC fluidization to provide high surface area for biofilm formation. Although the AFBR achieves excellent COD removal efficiency due to biological activities, concerns are still made with nutrient such as nitrogen remaining in treated wastewater. In this study, FO membrane was applied to treat the effluent produced by AFBR. Removal efficiency with total nitrogen (TN) was investigated with draw solution (DS, NaCl) and hydrodynamic condition (i.e., recirculation flow rate) along FO membranes. Permeability of FO membrane increased with increasing DS concentration. About 85% of TN removal efficiency was observed with the FO membrane using 1 M of NaCl DS. During operational period of a day, no permeate flux decline was observed.
        6.
        2018.05 구독 인증기관·개인회원 무료
        본 연구에서는 해수를 유도용액으로 사용하고 하수처리수를 공급수로 사용하는 정삼투막 공정의 유기/바이오 오염물에 의한 막오염을 저감하기 위해 폴리도파민/탄소 나노 튜브 복합 분리막을 제작하였다. 분리막은 기존 계면중합반응에 탄소 나노 튜브를 첨가하여 초박형 복합 분리막을 제조한 후, 폴리도파민으로 코팅시켜 제조하였다. 제작 된 분리막은 알긴산나트륨(Sodium alginate)용액과 미생물(Pseudomonas aeruginosa PA01) 부착 실험을 통하여 수투과도와 막오염도를 평가하였다. 그 결과, 폴리도파민/탄소 나노 튜브 복합 분리막은 복합되지 않은 분리막에 비하여 높은 수투과도와 낮은 막오염 성능을 보였다.
        7.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Modified coagulants were investigated for the removal of phosphorus from secondary effluent of wastewater treatment. The modified coagulants were prepared by mixing alkali earth metal ions such as calcium and magnesium. The basicity of a coagulant influenced on the removal of phosphorus, and coagulants with basicity of 5.9% showed a better removal of total phosphorus than that of 38.5%. Also, coagulants with alkali earth metals enhanced the performance of coagulation by 10% and resulted in 67.1% for total phosphorus removal. Moreover, the removal of suspended solids and chemical oxygen demand was improved using coagulants with low basicity and earth metal ions. Results of this study demonstrated that the use of coagulants with low basicity, and calcium and magnesium ions is recommended to improve wastewater effluent quality.
        4,000원
        8.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Pollutants removal and disinfection effect of secondary effluent from final settling tank of sewage treatment plant of W city were investigated in Loop Reactor using ordinary granular activated carbon(GAC) and GAC coated with silver nanoparticles. The results showed that the removal efficiency of CODMn, T-N and T-P using GAC with silver nanoparticles were higher than using the ordinary GAC. The removal efficiency of T-P using GAC with silver nanoparticles is 45.4% and that of T-P using ordinary GAC is 30.9% in the same case of the input amount of 20 g/L of GAC. The total califorms is reduced according to increasing input amount of GAC with silver nanoparticles and ordinary GAC. The disinfection efficiency of total coliforms in case of GAC with silver nanoparticles is much higher than that in case of ordinary GAC. For all experiments using the silver nanoparticles, the total coliforms is under 26 cfu/mL and this shows very excellent disinfection effect.
        4,000원
        9.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Control degree and property changes of dissolved organic matter (DOM) were conducted by coagulation of chemical treatment for 2 sewage treatment plants with different technical methods. As the result, SUVA value of the second treated water (supernatant of the second settling pond after biological treatment) was increased and DOC was reduced in comparison with supplied raw water. And, SUVA value and DOC were reduced by coagulation after coagulation treatment of the second treated water. Properties of dissolved organic matter for 2 sewage treatment plants's DOC were divided. As the result, there was lots of hydrophilic component with hydrophilicity in case of plant A. In case of the second treated water, Plant A showed fulvic acid with little molecular weight was reduced among the hydrophobic component with hydrophobicity, but numic acide with lots of molecular weight was increased. However, in case of plant B, both fulvic acid with little molecular weight and humic acid with lots of molecular weight were increased among the hydrophobic components with hydrophilicity. Before the operation of phosphorus facility, properties of dissolved organic matter after biodegradation with effluent water showed hydrophilic components were reduced and hydrophobic components were increased. However, after coagulation treatment of the second treated water, hydrophilic components and hydrophobic components were outstandingly decreased or increased. During the biodegradation after coagulation treatment, hydrophilic components were significantly decreased and hydrophobic components were increased.
        4,000원
        10.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to suggest the cause analysis and mitigation measures of foaming generated in the effluent of wastewater treatment plant. The foam generated in the outlet connected with the tidal river system was identified as structural problems. And the main cause of foaming was air entrainment by an impinging jet and the internal accumulation by the diffusion barrier. In consideration of these conditions, it present the effective ways such as micro-screen and submerged outlet, to mitigate the foaming generated in the water channel and outlet end.
        4,000원
        11.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 하수처리수를 원수로 사용하여 직접 접촉식 막증발법을 적용하여 원수 온도와 원수 유량 변화에 따 른 하수처리수의 COD, TN, TP, TOC의 제거율 변화와 여과플럭스의 변화를 측정하였다. 또한 하수처리수에 의한 분리막의 오염 가역성을 평가하기 위해 1차 증류수만을 사용하여 물리세정을 수행한 후 플럭스의 회복률을 측정하였다. 실험결과 원수 의 온도 및 유량에 관계없이 원수가 3배 농축될 때까지 여과를 진행하였음에도 불구하고 하수처리수의 주요 오염물질인 COD, TN, TP, TOC에 대한 제거율이 92% 이상으로 높게 나타났다. 또한 비교적 낮은 온도인 50°C와 60°C에서 원수의 유량에 따라 최소 13.8 LMH에서 20.3 LMH로 높은 여과플럭스를 나타냈다. 그리고 높은 농축계수까지 여과 실험을 진행했음에도 불구하 고 낮은 여과플럭스의 감소를 나타냈으며 1차 증류수를 이용한 짧은 시간 동안의 물리세정만으로 최소 90% 이상의 높은 여과 플럭스 회복율을 나타냈다. 따라서 하수처리수 재이용을 위한 공정으로 막증발법의 적용이 충분히 가능할 것으로 판단된다.
        4,000원
        12.
        2015.05 구독 인증기관·개인회원 무료
        최근 방류수 수질 강화에 따라 총인 처리시설의 설치와 응집제 사용량이 증가하고 있다. 본 연구는 유입하수에 포함된 응집제 성분(Al3+, Fe3+ 등)을 활용하여 PO43-와 응집시킴으로써 하수처리공정에 별도의 응집제 주입 없이 총인 농도를 0.2mg/L 이하로 제거할 수 있는 MBR 하수처리공정을 개발하는 것이다. 활성슬러지와 차아염소산나트륨으로 제조한 알칼리슬러지를 MBR 공법의 생물반응조에 주입하여 적정 pH를 유지시킴으로써 유입하수 중의 용존성 이온을 상호 응집시켜 고형화 하였고 분리막으로 고액 분리하여 하수처리수의 총인 농도를 0.2mg/L이하로 달성하였다. 이 연구를 통해 개발한 공법은 응집제 주입 없이 하수처리수의 총인 농도를 0.2mg/L이하로 제거하여 약품비용을 절감에 기여할 것으로 예상된다.
        13.
        2015.05 구독 인증기관·개인회원 무료
        포항시 하수처리수 재이용 시설은 UF-RO 공정을 통해서 일 10만 톤의 재이용수를 생산하여 철강 산업단지에 공급하는 시설로서 2014년 8월부터 운영 중이며, 2020년 기준 포항시에서 예상되는 물 부족량의 45%를 충당할 것으로 예상한다. 본 시설의 전처리 공정은 침지형 UF 막으로, 회수율 95%, Flux 25.7 L/m²-h로 운영되며, 역삼투 분리막은 회수율 80%, Flux 20 L/m²-h로 운영된다. 농축수 25,000톤 중 9,000톤은 생물 막 여과를 통해 처리되어 방류되며, 16,000톤은 하수처리장으로 반송된다. 본 연구에서는 하수처리수 재이용 시설의 분리막 오염 특성에 대해서 살펴보고 운전 자료를 바탕으로 안정적인 실시간 운영을 위한 공정 구성 및 운전 방법에 대해 검토하였다.
        14.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents PKES(PuKyung -Excel based Simulator) for WWTPs(wastewater treatment plants) by using MS Excel and VBA(Visual Basic for Application). PKES is a user-friendly simulator for the design and optimization of the whole plant including biological and physico-chemical processes for the wastewater and sludge treatment. PKES calculates the performance under steady or dynamic state and allows changing the mathematical model by the user. Mathematical model implemented in PKES is a improved integration model based on ASM2d and ADM1 for simulation of AS(activated sludge) and AD(anaerobic digestion). Gaseous components of N2, N2O, CO2 and CH4 are added for estimation of GHGs(greenhouse gases) emission.The simulation results for comparison between PKES and Aquasim(EAWAG) showed about the same effluent concentrations. As a result of verification using by measured data of BOD, TSS, TN and TP for 2 years of operation, calculated effluent concentrations were similar to measured effluent concentrations. The values of average RMSE(root mean square error) were 1.9, 0.8, 1.6 and 0.2 mg/L for BOD, TSS, TN and TP, respectively. Total GHGs emission of WWTP calculated by PKES was 138.5 ton-CO2/day and GHGs emissions of N2O, CO2 and CH4 were calculated at 21.7, 28.9 and 87.9 ton-CO2/day, respectively. GHGs emission of activated sludge was 32.5 % and that of anaerobic digestion was 67.5 %.
        4,200원
        17.
        2017.05 서비스 종료(열람 제한)
        우리나라는 지형 특성상 효율적인 수자원 확보가 어려운 실정이기 때문에 안정적이고 지속적인 수자원 공급을 위해 수자원 개발의 필요성이 대두되고 있다. 우리나라의 기존 수자원확보는 대형 댐이나 저수지 형태가 대부분이지만 이는 축조로 인해 대규모 생태계 훼손의 우려가 있어 최근 정부는 해수의 담수화 시스템 개발, 일회성 용수 재사용, 하수 재이용 등 새로운 정책을 시도하고 있다. 우리나라의 하수 재이용율은 매년 꾸준히 증가하는 추세이며 막 분리법, 이온교환 처리법 등 다양한 재이용수 개발공법에 대한 연구가 진행되고 있다. 하지만 막 여과는 막의 수명이 비교적 짧고 막 교환비용이 높은 특성을 가지며, 이온교환 공정은 유지관리가 어렵고 용량에 비해 처리 비용이 고가인 단점이 있다. 따라서 본 연구에서는 이러한 처리법 외에 전기화학적 처리방법인 전기응집에 대한 연구를 시도하였다. 전기응집 공법은 유입 원수에 큰 영향을 받지 않아 폐수성상을 가리지 않고 오염물질을 효과적으로 처리할 수 있으며, 다른 공정과 비교했을 때 설치면적 당 처리 용량이 커서 경제적이다. 이에 본 연구에서는 전기응집 공법에서 영향인자로 알려진 전류밀도, 전극 간격, 교반속도와 시간에 따른 제거효율을 Jar-test를 통해 확인하고 최적조건을 도출하였다. 또한 도출해낸 최적조건에서 전기응집을 이용해 하수처리수의 재이용수로 이용 가능성에 대해 판단하고자 하였다. 전류밀도는 0.036A/cm², 전극간격은 0.3cm, 교반속도와 시간은 100rpm, 5분에서 가장 높은 제거효율을 보여 이를 최적조건으로 결정하였다.
        18.
        2011.06 KCI 등재 서비스 종료(열람 제한)
        The objectives of this research are to investigate the proper coagulation conditions which are a type and doses of coagulants, mixing conditions (velocity gradients and mixing times), pH and so on through Jar-test, to evaluate the flux variations, permeate, backwashing according to characteristics of pretreatment of the wastewater by means of MF membranes for river maintenance water reuse. The effluent water from B-city K-sewage treatment plant are used for this research. Turbidity and suspended solids(SS) are 14.2 NTU and 10.4 mg/L respectively. This condition causes fouling for membrane process. The flux decline could be reduced when coagulation pretreatment was carried out. Optimal coagulations PAC which are commonly used in the sewage treatment plant was observed in this research. The results indicate that an optimal coagulation dose and pH are 80 ppm and pH of 7 respectively, but coagulation efficiency was lower at strong acid or strong base. Results showed that continuous and steady operations in membrane separation process by means of the effective removal of organic matter and turbidity with coagulation pretreatment of sewage secondary effluent were achieved.
        1 2