        21.
        2022.11 구독 인증기관·개인회원 무료
        Currently, many complaints have been filed by local residents on helicopter noise while the law on noise prevention and damage compensation at military airfields and military ranges has been in effect since November 27, 2020. The airfields operated by state agencies are inevitably used to defend the country, defend the country, and protect the lives of the people, but various efforts are needed to minimize noise complaints. In general, helicopters operating in a specific area exhibit different noise frequencies depending on the number or size of wings for each type, takeoff speed, and takeoff altitude. Therefore, by measuring and analyzing noise in the take-off stage of a number of helicopters operating in a specific area, this study aims to present more effective noise prevention measures by analyzing the compliance of each type of helicopter with variables such as take-off speed, take-off altitude, and rise rate. Therefore, the results of this study will be significant in terms of resolving complaints and reducing compensation expenditures of local residents around the airport.
        22.
        2022.11 구독 인증기관·개인회원 무료
        Anomaly detection for each industrial machine is recognized as one of the essential techniques for machine condition monitoring and preventive maintenance. Anomaly detection of industrial machinery relies on various diagonal data from equipped sensors, such as temperature, pressure, electric current, vibration, and sound, to name a few. Among these data, sound data are easy to collect in the factory due to the relatively low installation cost of microphones to existing facilities. We develop a real time anomalous sound detection (ASD) system with the use of Autoencoder (AE) models in the industrial environments. The proposed processing pipeline makes use of the audio features extracted from the streaming audio signal captured by a single-channel microphone. The pipeline trains AE model by the collected normal sound. In real factory applications, the reconstruction error generated by the trained AE model with new input sound streaming is calculated to measure the degree of abnormality of the sound event. The sound is identified as anomalous if the reconstruction error exceeds the preset threshold. In our experiment on the CNC milling machining, the proposed system shows 0.9877 area under curve (AUC) score.
        23.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The main noise of a large machine can be divided into the noise generated during the work process and the noise of the equipment used in the work. The main noise in the noisy area is the air propagation sound caused by the operation of the rotating body. This is not fixed, but changes depending on the situation at the time of measurement. Workplaces exposed to noise can harm workers' health and cause related industrial disasters, resulting in many complaints and social problems, and eventually lead to a lot of damage in terms of productivity. Large machines that need noise reduction the most are motors, pumps, fans, blowers, and compressors. To reduce noise, mechanical structure or material changes are most effective. In this study, the noise reduction method and noise management method of large machines were investigated. To measure noise, the same method as ISO 3744 in Europe and JISA 8305 in Japan was used as KS A ISO 3744, KS A ISO 3746, which is a method of measuring the acoustic power level of machinery.
        4,000원
        24.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the noise reduction effect of the steam vent silencer was investigated by performing a transient flow analysis applying the Loss Model, a porous flow analysis model, and calculating the noise intensity from the pressure fluctuation according to the time change. As a result of flow analysis, it was confirmed that the noise intensity decreased as the number of diffusers and the number of splitters made of foamed aluminum increased. In the case of three-stage diffusers, the noise intensity decreased by up to 33.4 dB when six foamed aluminum with a thickness of 150mm were installed.
        4,000원
        25.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to the development of the industry, the machinery of plant facilities becomes large and operates at high speed and high power. Workers at plant facility sites are exposed to high noise and impact noise, and the number of people with noise-induced hearing loss is increasing every year. Therefore, in order to minimize such damage, many efforts have been made to reduce the noise of large machines in production facilities. Measures, education, and recommendation of wearing hearing protectors are needed to protect the hearing of workers in high noise industries. In addition, it is urgent to reduce noise sources by blocking noise propagation paths, such as installing noise boxes and silencers, and installing facilities and equipment that generate less noise. It is necessary to repair the noise reduction device of the large machine of the plant or to study the noise reduction device when designing the plant.
        4,000원
        27.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The waterpower generation of the dam generates electricity by revolving the turbine through a water pipe using the difference of high/low of water, the revolving turbine makes an occurrence a terribly loud noise. Accordingly, in the water turbine generator room located on such hydroelectric generator, since a mutual communication is not establish properly when working, they are suffering many difficulties, and it is real state that such noise damages even to those workers in the office of power plant. Since the most of dam water turbine generator room built in domestic country had used the finishing materials of a huge volume and a high reflexibility, it is carrying more amplifying function with the turbine noise arising when generates the electricity. Therefore, there is not only a difficulty for mutual communication among those workers in the workplace, but also it becomes an obstruction factor for working even to the workers in the adjacent office, and because they are suffering the mental and physical damages, it is actual state that a noise-reduction measure is urgently needed. As a result of the study, on the object with the dam hydraulic turbine dynamo room in which an acoustic defect is being occurring, this Study has conducted the Psycho-Acoustics Experiment about the Delivery of Voice Information using Auralization Technique that can experience the Virtual Acoustic Field. It is considering that such study result could be used usefully for improvement of the Voice Definition when construction the dam hydraulic turbine dynamo room, in the future.
        4,000원
        28.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, Noise was measured and its frequency size and characteristics were analyzed in office spaces. In order to improve the noise environment, the sound masking technology was used to extract and apply pink noise-based sound masking content suitable for it to obtain a noise reduction effect by improving the noise environment. As a result of this study, We think that the problem of spatial noise can be further improved and changed by mixing these sound masking systems as noise blocking facilities through appropriate harmony with interior facilities from architectural acoustics to construction. It was confirmed that there is an effect of improving the noise environment not only for blocking or improving external inflow noise, but also for various noises generated indoors, such as call centers.
        4,000원
        29.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The exposed aggregate concrete pavement (EACP) is adopted to achieve low traffic noise and long-term skid resistance in European countries such as Belgium and Germany. In Korea, it is first introduced at the Myeon Cheon field site in 2010. It reduces 3 dB(A) from tire–pavement noise compared with transverse tining. Recent investigations show that EACP can reduce tire–pavement noise by an additional 5 dB(A) compared with transverse tining. In this study, the tire–pavement interaction noise of EACP is compared with that of conventional pavements such as asphalt pavement, next-generation concrete surfaces (NGCS), and transverse tining. METHODS : EACP is constructed at two field sites on the SOC research center and Yeo-Ju test road to compare the noise level via close proximity noise measurement. In addition, the noise is measured using two vehicle type based on vehicle speeds of 60, 80, and 100 km/h. RESULTS : The results of noise measurement obtained from the SOC research center are as follows: Porous asphalt pavement 92.8 dB(A), HMA 96. dB(A), transverse tining 100.1 dB(A), and 8 mm EACP 97 dB(A) at a driving speed of 80 km/h. For the case of the Yeo-Ju test road. The noise levels at a driving speed of 80 km/h are as follows: 6 mm EACP, 93.6 dB(A); asphalt grooving pavement, 94.72 dB(A); 8 mm EACP, 95.2 dB(A); NGCS, 95.2 dB(A); transverse tining, 104.1 dB(A). CONCLUSIONS : The result of noise measurement of two sites in the SOC research center and test road shows that the noise level of the 6 mm EAC is lower than that of concrete pavement, such as tining and NGCS, and similar to that of asphalt pavement. In addition, the noise level of the 8 mm EAC is similar to that of the NGCS pavement. The noise reduction effect of the EAC is greater when small-sized coarse aggregates with lower flat and elongation ratios are used.
        4,000원
        30.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        High concentrations of fine particles are increasingly being detected due to inflows from abroad and local emission sources in Korea. As most people spend about 90% of their time indoors, the use of indoor air cleaners has grown significantly as they are now thought to be essential items. In this study, the noise, power consumption, and clean air delivery rate (CADR) of commercial air cleaners were analyzed according to the structural shape of the air cleaners. Analyses were performed based on the experimental results of 249 cases for air cleaners certified by Korea Air Cleaning Association. The air cleaners with front inlet and upper outlet air flow direction, which currently account for the highest market share, were found to have the highest noise per CADR (dB(A)/(m3/min)). On the other hand, the air cleaners with the inlet and outlet air flow in the same horizontal direction were found to have lowest noise per CADR than other structures.
        4,000원
        31.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Noise is a sound that humans do not want. In this study, Based on the Rotax 912 engine, which is most commonly used in Korea, we will look at noise and thrust changes by changing the propeller blade angle by 1 degree for the two-blade Sensenich Propeller and the three-blade Wrap drive Propeller. Through this, we want to check which part of the propeller angle produces the least noise and the least thrust loss for each propeller, and propose a propeller operation plan in a noisy area based on the value.
        4,000원
        32.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        통상적으로 직업소음에 의한 청력손실을 최소화하기 위해서는 작업자가 8시간 동안 85 dBA 이상 소음에 노출되지 않도록 권고하고 있다. 이번 연구에서는 실습선박에서 7종류의 담당업무별 작업자들의 소음노출레벨을 측정하였다. 항해 중, 24시간 동안 작업자의 위치하는 A특성등가소음레벨(LAeq,i)과 소음장소의 지속기간(h) 및 소음기여도(Lex,24h,i)를 고려한 소음노출레벨(Lex,24h)을 측정하였다. 그 결과, 갑판사관 그룹 Lex,24h=56.1 dB, 갑판부원 그룹은 Lex,24h=58.9 dB, 실습항해사들은 Lex,24h=62.0 dB, 취사부원들은 Lex,24h=64.3 dB, 실습기관사그룹 은 Lex,24h=91.1 dB, 기관사관 그룹은 Lex,24h=91.1 dB, 그리고 기관부원 그룹은 Lex,24h=95.1 dB를 나타내고 있다. 따라서 기관 업무를 담당하는 기관사들, 기관부원들 그리고 기관실습생들은 반드시 청력보호구를 착용해야함을 알 수 있었다. 소음이 심한 기관실에서 청력보호구를 착용한다면 기관사관그룹은 Lex,24h=23.1 dB, 기관부원그룹은 Lex,24h=24.4 dB 그리고 기관실습생들은 Lex,24h=21.5 dB의 소음노출레벨을 줄일 수 있을 것으로 추정된다. 또한 실습생들의 거주구역인 제2 강의실 겸 식당구역에 바닥시공을 64 mm, A-60-class 뜬바닥 구조로 개선했다면 실습항해사들의 소음노출도는 Lex,24h=4.3 dB, 실습기관사들은 Lex,24h=1.8 dB 정도 추가적인 감소가 있었을 것이다.
        4,000원
        33.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Road surfaces and tires have a great influence on road noise in automobiles. Therefore, this study attempted to investigate the effect of changes in road surface and tire tread on road noise. For six road surfaces, road noise was measured and analyzed while changing two types of tire treads. In all frequency bands, the sound pressure of the road surface with a relatively large roughness was higher than that of other roads. And in the case of a road surface with relatively large pore, it was investigated that noise was reduced compared to other road surfaces due to the sound absorption effect in the low frequency area. On roads with irregular road roughness, the high sound pressure was exhibited in all frequency bands regardless of tire tread, indicating an increase in road noise due to irregular wear on roads. It was confirmed that the noise deviation due to the change in road surface was larger than the noise deviation due to the tire structure, and it is judged that noise research according to the structure and condition of the road surface.
        4,000원
        35.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The prospect of the highway traffic road construction has led to resistance from residents, partly based on noise and vibration issues. Particularly, as tracks often pass closely to residential dwellings, constructors are then required to take account of noise and vibration. So the prediction of noise and vibration for highway traffic is very important thing. The highway traffic noise and vibration make one specific issue. For the highway traffic road, this paper concerns the noise by the wheel/tire and the structure-borne noise by the road. Based on the results, this paper proposes the source model of highway traffic noise and the calculation model for highway traffic noise. Also prediction model is presented with traffic noise which are calculated by considering the power level of a source for one-third octave band, ground absorption and barrier deflection. A lot of empirical data is needed to predict the noise and vibration. And one of the best ways to control the wayside noise is to analyze the noise level.
        4,000원
        36.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The prospect of the new railway construction has led to resistance from residents, partly based on noise and vibration issues. Particularly, as tracks often pass closely to residential dwellings, constructors are then required to take account of noise and vibration. So the prediction of noise and vibration for train is very important thing. The train noise and vibration nearby the elevated railway make one specific issue. For the elevated railway, this paper concerns the rolling noise by the wheel/rail and the structure-borne noise by the bridge. Based on the results, this paper proposes the source model of elevated structure-borne noise and the calculation model for elevated railway noise. Also prediction model is presented with rolling noise and elevated structure noise which are calculated by considering the power level of a source for one-third octave band, ground absorption and barrier deflection. A lot of empirical data is needed to predict the noise and vibration. And one of the best ways to control the wayside noise is to analyze the noise level.
        4,000원
        37.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Numerical analysis for flow and noise characteristics of sirocco fan design factors is conducted in this study. 4 cases of blade angle(α=24°~30°) and 5 cases of RPM(390~1170RPM) are calculated. Flow characteristics are compared for the number of blades. Outlet flow rate is tended to decrease as the number of blades increased. There is little difference in the flow characteristics for the angle of blade. The highest outlet flow rate is predicted at α=24°, and the lowest at α=28°. Flow and noise characteristics are compared for α=24° and 26°. Outlet flow rate is almost similar in both cases, but noise for α=24° is predicted higher at high RPM conditions.
        4,000원
        38.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Assessment of noise exposed population is to check the environment noise level and social influence in order to reduce the risks such as annoyance and disturbance that are generated by environmental noise. Also, this method suggests the preferential noise abatement policy and action plan by accurately finding the area that the noise causes harmful effect to human health. Recently, a noise map, which can predict noise in comprehensive area, is used for the assessment of noise exposed population, breaking from the methods using existing measures. In particular, countermeasure for noise can be considered more effectively by using assessment methods of noise exposed population for specific noise level, area and building types which are the main input factors in noise maps. In this study, we propose noise prediction at traffic noise due to noise map.
        4,000원
        39.
        2021.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Building Equipment field is getting important recently which satisfies the requirement for pleasant living environment. But, the noise generated in the machinery room often violates the pleasant living environment of residents in complicated form of airborne noise and soild sound, its seriousness is increasing so that damage of noise can take large percentage of environmental complaints. So, soundproofing and insulation of sound which can minimize such noise and effective countermeasure in case of civil appeal are required, but research materials regarding building equipment are definitely insufficient domestically. In this respect, this study used Zwicker parameter which is applied by psychological and acoustic reactions according to sound quality, analyzed sound quality of 32 kinds of building equipment used in machine room, and analyzed correlation between dB(A) and PSIL which are items of Zwicker parameter and noise valuation based on that. As the results, if valuates altogether loudness and unbiased annoyance which have high correlation with other existing suggested valuating methods, it is considered that it can be utilized as basic data for more reasonable and accurate grasping characteristics of noise from building equipment and for building effective countermeasure in case of civil appeal.
        4,000원
        1 2 3 4 5