검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 18

        2.
        2024.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The existing wire mesh clip forming process requires improvement as the production process is semi-automatic, which greatly threatens the safety of workers and exposes them to labor intensity and industrial accidents. In this research and development, we designed and developed an automated wire mesh automatic clip system by improving problems in the existing welded wire mesh production process. As a result, the production volume per hour was improved from 450 to 516, and the clip formation time was improved, shortening the production time to 42.5 seconds. Additionally, the defect rate was reduced from 7% to less than 3%.
        4,000원
        3.
        2024.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study examines the rise of the Body Positive Movement on TikTok and its role as a form of online content activism influencing the fashion design and industry. Through a combination of literature review and case study methodology, the study explores the expression techniques and thematic types of Body Positive Movement on TikTok. Reviews of literature, previous studies, online articles, fashion journals, and relevant search terms on TikTok informed a definition of Body Positive Movement and an analysis of its formation and rise. The research findings confirm the impact TikTok content on Body Positive Movement has on the fashion industry in addressing external factors (i.e., ‘Appearance’, ‘Race’, ‘Aging’, ‘Physical Disability’) and intrinsic factors (i.e., ‘Acceptance of Diversity’, ‘Self-Esteem’, ‘Rejection of Stereotypes’, ‘Appropriate Representation’, ‘Information Provision’). The key external factor , ‘Appearance’, includes subcategories such as ‘Body Shape’, ‘Body Hair’, ‘Skin’, and ‘Facial Features’. TikTok content creators on fashion creatively combine music, emojis, and visual storytelling to exhibit positive self-perception concerning these factors. A significant finding of the study is that short clips predominantly manifesting external factors differentiate into informative or enlightening videos associated with intrinsic factors. The study underscores Body Positive Movement's important influence on the fashion industry from design to presentation.
        5,700원
        4.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 코마개의 사용 여부에 따라 MRI 영상을 분석함으로써 숨 참기의 정확도를 향상할 도구로써 코마개가 실 효성이 있는지 검증하고자 하였다. 이를 위해 수검자에게 코마개가 없는 자연 호흡과 코마개를 사용한 구강 호흡 상태에서 호기 후 숨 참기를 지시하고 MRI 영상을 획득하였다. 영상은 2D 경사 자기장 에코 시퀀스로 획득하였고 초당 1장씩, 총 15장을 얻어 숨 참기 상태를 분석하였다. 숨 참기의 상태를 정량적으로 평가하기 위해 우측 폐 면적 을 측정하였다. 그리고 첫 번째 영상의 폐 면적을 기준으로 나머지 영상들에서 폐 면적의 절대 오차값을 구해 비교하 였다. 더불어 첫 번째 영상을 기준으로 나머지 영상들의 기하학적 유사도를 평가하기 위해 SSIM 값을 계산하였다. 실험 결과, 자연 호흡 상태에서 절대 오차는 평균 216.79 ㎟로 나타났다. 반면, 코마개를 사용한 구강 호흡의 경우 평균 55.94 ㎟로 나타나 자연 호흡과 비교하여 약 74.19% 감소하였다. SSIM 값은 자연 호흡 시 평균 0.7, 구강 호흡 시 0.76으로 나타나 기하학적 유사도가 약 6% 향상되었다. 이는 코마개 사용 시 호흡의 초기 상태를 잘 유지함 으로써 숨 참기의 정확도가 향상되어 능동적으로 호흡 상태를 조절할 수 있는 도구로써 충분한 가치가 있음을 증명한 다. 따라서 복부 MRI 검사에서 호흡에 따른 인공물을 개선하는 데 코마개가 도움을 줄 수 있으며 영상 개선 및 업무 효율을 높이는 도구로써 충분히 활용할 수 있다.
        4,000원
        5.
        2023.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        횡하중에 작용하는 철근 콘크리트 기둥은 연성능력 확보를 위해 띠철근의 양 단부를 135° 구부려 시공하는 상세가 요구된다. 그러 나 이러한 띠철근 상세는 시공이 매우 까다로와 실제 현장에서는 제대로 시공이 되지 않기도 한다. 이를 대체하기 위해 본 논문에서는 강재 클립형 연결장치가 적용된 철근 콘크리트 기둥에 대해 횡방향 반복가력 실험을 수행하고 그 구조적 성능을 평가하였다. 총 4개 의 실험체가 제작되었으며 주요 실험변수는 강재 클립형 연결장치 및 고강도 콘크리트 사용 여부이다. 또한 대상 구조물에 대해 3차 원 유한요소해석 모델을 개발하고 이에 대한 비선형 해석을 수행하였으며, 해석 및 실험결과를 비교하고 분석하였다. 그 결과 강재 클 립형 연결장치가 설치된 콘크리트 기둥이 반복 횡하중에 대해 기존의 표준갈고리 상세를 지닌 콘크리트 기둥과 동등한 혹은 그 이상 의 성능을 지니고 있으며, 개발된 유한요소해석 모델이 실험결과를 정확히 잘 예측하는 것으로 나타났다.
        4,000원
        6.
        2023.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Laparoscopy instrument requires blood vessel ligator to prevent blood leakage. Clip ligation device is widely used to prevent blood loss and secure surgical vision by using blood vessel ligator. However, in order to properly install the clip to the vessel ligator and ligate the blood vessel by the ligation machine, the device is properly operated and the parts constituting the jaw areas should be ensuring sufficient strength and rigidity during the operating. Therefore, the clip binding forces were calculated through a dynamic model of the blood vessel ligator. As a result, the force satisfies the target value of 8.5 N or more regardless of the grip force positions. And structural analysis was carried out to find out the maximum resistance force at the tip of the inner shaft. The maximum load was about 45.6 N, which sufficiently satisfies the development target of 40.0 N or higher.
        4,000원
        7.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In SRC column, the closed hoops are applied with the same detail of both 135° standard hooks to expect the same performance as hoops of RC columns. This standard detail is actually complicated to construct, thus, two separating rebars are connected in the form of a square shape and welded over the overlapping section. But this is also complicated in construction practice. Therefore, this study describes experimental results regarding cyclic behaviors shown with alternative hoops cramped by the steel clip type-binding device instead of welding and standard specimen. As a result of the experiment, the specimens with alternative hoops of the SRC column showed comparable performance to the specimens with closed hoops. Therefore, it can be evaluated that the alternative hoops applied with the rebar confinement clips in the SRC column can replace the closed hoop.
        4,300원
        8.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to evaluate seismic performances of a modular house system developed by a simple 4-clip fastening method and double metal assembly made of lightweight metals. In order to evaluate structural and non-structural seismic performances of the system. Shaking table test was carried out with full-scale modular units, and a nonlinear pushover analysis was performed to obtain suitable seismic responses for story drifts, displacements, force resistances and dynamic properties of the system. Through 3D analysis and shaking table test, the current method of lightweight modular metal unit assembly and systems with seismic performance of a 4-clip fastening type modular house were demonstrated safe and effective to seismic design.
        4,000원
        9.
        2021.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        총담관으로의 클립 이동은 복강경 수술의 드문 합병증이다. 저자들은 4년 전 복강경 담낭절제술과 복강경 총담관탐색술을 동시에 받은 66세 남자에서 Hem-o-lok 클립 이동으로 인한 담관 결석 1예를 문헌고찰과 함께 보고하고자 한다. 상복부 통증을 주소로 내원한 환자의 복부 전산화단층촬영에서 담관의 확장과 다량의 담관 결석 및 담관을 침범한 이물질이 의심되었다. 내시경역행담췌관조영술을 하여 다량의 담관 결석과 함께 이물질을 제거하였다. 이물질의 정체는 Hem-o-lok clip이었다. 복강경 담낭절제술과 복강경 총담관탐색술을 받은 환자가 상복부 통증을 호소한다면, 드물지만, 클립 이동에 의한 담관 결석 가능성도 염두에 두어야 한다.
        4,000원
        11.
        2015.03 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        본 증례는 복강경 담낭절제술 후 10년이 경과되어 발생한 총담관 결석의 예로, 결석 내 포함된 외과용 클립이 담관결석의 원인이 되었을 것으로 추정된다. 내시경으로 제거한 총 담관결석 내에 외과용 클립이 발견되어 수술시 사용한 외과용 클립이 총담관 내로 이동하여 총담관 내 결석의 핵으로 작용했을 가능성을 뒷받침한다. 담낭 절제술 후 발생한 우상 복부 통증으로 내원한 환자에서 외과용 클립에 의한 총담관 결석은 진단에 있어 고려해야 할 부분으로 생각된다. 진단은 단순복부촬영에서 우상복부에 금속성 물질이 관찰된다면 의심할 수 있겠으나, 내시경적 담췌관조영술에서 총담관 내에 음영결손과 결석 내부에 금속성 물질이 관찰될 때 가능하다. 치료는 일반적인 총담관 결석의 치료와 동일하며, 내시경을 이용한 유두괄약근 절개술 후 바스켓 및 풍선 카테터를 이용한 결석 제거가 유용하다.
        3,000원
        12.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기초에 강결되어 도로변에 노출된 각종 지주는 정면충돌 뿐 아니라 측면충돌에 특히 위험하다. 클립형 단부분리장치를 갖는 지주는 정면충돌에 효과적이고 다방향으로 분리가 가능하기 때문에 측면충돌에도 효과적이다. 본 논문은 강결된 지주의 측면충돌에 대한 위험성을 보이고 클립형 단부분리장치를 갖는 지주의 충격완화 효과를 보이기 위하여 측면충돌실험을 실시하고 그 결과를 분석 정리한 것이다. 이를 위하여 미국의 NCHRP Report 350을 기반으로 측면충돌의 기준을 제시하고 D101.6mm(t=4.2mm)의 지주가 강결된 경우와 클립형 단부분리장치로 연결된 경우에 대하여 820kg의 소형차로 충돌속도 50km/h의 측면충돌실험을 실시하였고 단부장치의 저속분리가 가능한가를 35km/h의 측면충돌실험으로 확인하였다. 강결지주는 차량의 과다한 변형 및 전복, 안전지수 측면에서 측면충돌에 치명적이지만 클립형 단부분리장치로 기초에 연결된 경우 충돌피해를 크게 줄일 수 있음을 확인하였다.
        4,300원
        13.
        2019.08 서비스 종료(열람 제한)
        IT기술의 발전 및 스마트 터미널(Smart terminal)의 보급으로 정보를 검색하고 받아들이는 과정에서 쇼트 클립의 중요성이 갈수록 커지고 있다. 관광객들의 인터넷 관심도는 관광객 유동량과 관계가 있다. 본 논문은 중국 쇼트 클립의 시장 규모와 영향력을 분석하는 기초 위에 서안시(西安市)를 중심으로 틱톡 (TikTok) 영상의 방송 전후 관광객의 인터넷 관심도가 시간적, 공간적으로 어떤 변화를 나타내는지 분석 하였다. 거시적인 측면에서의 연구 결과는 첫째, 쇼트 클립은 매우 큰 시장 규모와 잠재력을 가지고 있다. 둘째, 쇼트 클립은 인터넷 시대의 효과적인 마케팅 모델로 도시 이미지의 수립과 전달에 중요한 영향을 미치고 있다. 셋째, 쇼트 클립은 촬영지 관광객의 관심도에 시간적, 공간적인 영향을 준다. 넷째, 5G 네트워크 의 발전에 따라 쇼트 클립 플랫폼을 중심으로 광고주, 장비 벤더, 동영상 프로듀서, 동영상 사용자 그리고 전송망 사업자가 포함된 소셜 미디어 생태계가 점차 형성된다. 미시적 방면으로 보면 첫째, 쇼트 클립의 발전이 인터넷 기술에 대한 의존성이 매우 크다. 둘째, 쇼트 클립이 소비자 행위에 중요한 영향을 끼친다. 셋째, 틱톡에서의 쇼트 클립이 방송된 후 서안(西安) 영흥방 (西安永興坊), 중경(重慶) 홍애동(重慶洪崖洞), 청해(靑海) 차가염 호수(青海茶卡鹽湖)에 대한 관광객의 관심도가 크게 변화한 것에 비추어 볼 때 쇼트 클립이 관광지를 홍보하는 데 좋은 효과가 있으며 영향권도 매우 크다. 넷째, 쇼트 클립이 갈수록 더 많은 분야와 융합하여 ‘쇼트 클립+’의 패턴으로 발전할 것이다. 분석에 의하면 쇼트 클립 수색과 정보 제공이 관광객의 관심도를 높이고 특히 틱톡 영상이 방송된 후 관광객들이 촬영지에 대한 인터넷 관심도가 크게 변화될 것을 알 수 있다.
        14.
        2019.04 서비스 종료(열람 제한)
        In this paper, seismic performance evaluation using 3D modeling of structural analysis was carried out to confirm and enhance the seismic performance of modular houses through the seismic performance evaluation scheme. Based on the results, the performance of structural members and joints in the modular house was investigated.
        15.
        2018.10 서비스 종료(열람 제한)
        This study is an attempt to develop modular house structural systems with safety seismic performances under maximum seismic load of 0.3G. The modular house system was designed with joints (plan) using four-clip simple fastening type, and was also adopted a type of double inter-metallic assembly modular systems using a light metal. The seismic performance was evaluated.
        17.
        2014.09 서비스 종료(열람 제한)
        Tracheobronchial foreign body aspiration can cause serious health problems in individuals of all age groups and requires immediate diagnosis and intervention. Patients with psychiatric disorders can aspirate foreign objects that may pose a danger to their health. Herein, we report on a case of curtain clip aspiration in a 44-year-old man with mental retardation. Chest radiography and bronchoscopy showed a sharp, pointed, S-shaped curtain clip inversely lodged in his left main bronchus. The curtain clip was removed successfully using flexible bronchoscopy, and no complications were noted.