In this study, a two-stage electrostatic precipitator (ESP) was developed using a novel automatic dry cleaning device to reduce the ultrafine particles in subway stations. Collection efficiency was evaluated with a pilot scale ESP (1.2m× 1.2m) and the scale of the test duct was half of the subway air handling unit. The maximum collection efficiency for 0.3 μm particles was 96.9%. In addition, we studied a method of automatic dry cleaning for maintenance of the ESP. The cleaning efficiency was analyzed according to the cleaning flow rate for each particle loading amount to achieve a recovery rate over 90%. In addition, we derived the equation to estimate the reduction in collection efficiency according to the particle loading amount. It was confirmed that the performance of the contaminated ESP was restored to the initial state by the automatic dry cleaning in this study and that the electrical energy consumption was 5 times lower compared to utilizing conventional water cleaning.
본 연구에서는 강화되는 황산화물 및 입자상물질의 배출규제를 만족시키기 위한 후처리장치로 습식전기집진기에 대한 실험적 연구를 수행하였다. 실험을 위해 선박용 중유(HFO, 황함유량 약 2.1%)를 연료로 사용하는 선박용 4행정 디젤엔진(STX-MAN B&W)을 활용 하였으며, 연돌에 설치된 습식전기집진기 입/출구에서 측정을 실시하였다. 미세먼지 측정을 위해서는 광학식 계측기(OPA-102) 및 중량농 도측정방식(Method 5 Isokinetic Train)을 이용하였으며, 황산화물 계측을 위해서는 FT-IR(DX-4000)을 사용하였다. 엔진부하는 50%, 75%, 100%로 변화시키면서 실험을 실시하였다. 실험 결과로, 엔진부하가 50%에서 100%로 변화함에 따라 미세먼지 저감 효율은 모든 부하 조건에서 94~98% 정도의 높은 저감 효율을 나타내었다. 추가적으로 습식전기집진기 퀜칭존에서 배기가스의 온도를 낮추는 과정 중 세정액에 의한 이산화황(SO2) 저감을 확인할 수 있었으며, 저감율은 엔진부하에 따라 55%~81%로 확인되었다.
전 세계 90 %의 인구가 WHO의 연평균 미세먼지 노출 기준(10 ㎍/㎥)을 초과한 공기를 흡입하고 있다. 전 세계적으로 육상뿐 만 아니라 해양에서 발생하는 질소산화물에 대한 규제를 통해 2차 오염물질, 초미세먼지 저감에 대해 노력하고 있으며 국내에서는 선박에서 미세먼지 발생의 주요한 원인인 황 함유량 저감과 환경친화적 선박의 개발 및 보급 등을 통해 깨끗한 해양환경 조성을 위한 노력을 하고 있다. 디젤엔진 유해 배출가스 저감을 위한 기술 중 압력 손실이 적고 높은 집진 효율 및 NOx의 제거와 유지 관리의 장점이 많은 전기 집진기의 수요와 중요성이 증가하고 있다. 본 연구는 총톤수 999톤급 선박의 2,427 kW 선박용 디젤엔진의 미세먼지 저감을 목적으로 개발된 전기 집진기를 예지보전단계에서 고장모드영향분석을 통해 장비 품질을 높여 선박 내에서의 내구연한을 높이고자 위험 우선순위 도출하였다. 위험 우선순위는 고장모드 241(poor dust capture efficiency)이 RPN 180으로 가장 높았다. Collecting electrode 에서 가장 많은 고위험 고장모드를 검출하여 집중관리 부품으로 관리해야 할 필요가 있었으며 원인으로 진동과 핀 풀림으로 인한 유 격 불량이 가장 많이 검출되었다. 핀 풀림 역시 근본적으로는 선체 또는 장비에서 발생하는 진동이 원인이 되어 발생할 수 있는 사항이기 때문에 핀 풀림이 발생하는 개소에 보완이 필요하겠다.
A single-stage electrostatic precipitator (ESP) was evaluated in terms of its performance in removing dust in subway tunnels. A wire-to-plate type ESP was tested in a small-scale wind tunnel. The effects of wire-to-wire spacing (2040 mm) and the material connecting wire-to-wire on the performance of ESP were investigated, with varying applied voltage and airflow velocity. A narrower wire-to-wire spacing showed higher collection efficiency at the same applied voltage. Lower electrical resistivity of material connecting wire to wire was more effective. Ozone generation in subway tunnel applications was insignificant.
In this study, we numerically analyzed flow and particle transport near the electrostatic precipitator in the tunnel according to train runs. When there was no train running, flow field was formed by a precipitator. Flow emitted from precipitator blocks the path along the tunnel, and therefore most contaminated air passes through the precipitator and can be cleaned. On the other hand, flow pattern during the train run was affected by train induced wind. A strong straight flow was generated at the front of train, and back flow was formed in the opposite line. When a train runs upward only (train start from suction section to blow section), the subway train transports contaminated particles along the tunnel. For downward train runs only case, the cleaned air reentered the contaminated section with train wind. Both train runs case showed combined flow and particle concentration pattern of both single train runs.
In this study, the odor causing in the under-fired charbroiling restaurant was reported in literature investigation,pilot test and field experimental verification. The charbroiling restaurant causes odor complaints of Neighbors soefficient reduction method is requested. Acetaldehyde, ammonia, sulfur compound and the oil mist of white smokeare found to cause odor from the charbroiling restaurant. Pilot test results show that in the removal efficiency ofodor, Electrostatic Precipitation was 67.4%, absorption was 81.2%, adsorption was 74.2% and the ElectrostaticPrecipitation & Adsorption the hybrid system with 85.7% respectively. In the same condition of the hybrid system(Electrostatic Precipitation & Adsorption), the odor removal efficiency were higher when the design parameterssuch as the discharge voltage and current were high. The process efficiency were higher when as the implanterpole was cylindrical. However, the process efficiency rapidly reduced due to the contamination of the processcomponent or material, as the operating time of the equipment is increased. Therefore, fixed maintenance and repairof the equipment is found to be are very important, for long term operation. Therefore, as the experimental resultof this study, applying hybrid system removed odors caused in under-fired charbroiling restaurant which areunregulated, is more effective device that settle civil complaints and preserve environment.
Particle collection efficiency and air cleaning capacity were tested for the two-stage electrostatic precipitator for use in indoor air cleaning systems. A wire-plate type ionizer was used as a particle charger and a dielectric film consisted of polypropylene (or polyethylene) coated metals and zigzagged metal electrodes was used as a particle collector in the electrostatic precipitator. Both particle collection efficiency and air cleaning capacity increased as increasing the applied voltage on the charger and the collector, and furthermore, as increasing the collector film width (i.e. collection area). Air cleaning capacities estimated by the product of particle collection efficiency and air flow rate were quite well consistent with the experimental ones with a proportional constant of 0.964. Ozone concentrations emitted from the charger at the applied voltages of 5.0 and 5.2 kV were less than 0.05 ppm, indoor ozone standards of UL 867-2002, KS C 9314 and SPS-KACA002-132. For the air flow rate of 11.7 m3/min, the applied floor area of 48.2 m2 could be obtained when 5.2 kV and 6.0 kV were applied on the ionizer and the collector, respectively and the collector of two 15 mm polyethylene dielectric films was used.
Numerical analysis was conducted to characterize the particle charging quantities in the charging cell of a 2-stage parallel-plate electrostatic precipitator with respect to particle size. The numerical method took into consideration of particle charging rate equations and particle equations of motion, allowing the locally varying non-uniform electric field and ion number concentration along the particle trajectory. The charging rate model developed by Lawless (1996) was used in the present study. According to the present study, the numerical results showed good agreement with the available experimental data.
Rapid industrial development has led to a serious problem of pollution in the industrial sector. With the increasing social need for environmental protection, research on air pollution prevention equipment for reducing pollutants in industrial processes is actively being undertaken. The deterioration of existent, installed facilities, their increased emission rates, and the strengthening of the effluent quality standards make complying with permissible emission standards difficult. In fact, installing new electric precipitators or complementing existent facilities is inevitable. The expansion and complementation of the installed electrical precipitators have led to improvements in dust collection efficiency, shorter working times, and lower costs. Because of its easy installation and simple manufacturing process, the production method with the discharge electrode of an electric precipitator is widely used. The following conclusions were reached by classifying discharge electrodes into four types based on the production method and mutually comparing them by their dust collection efficiency. None of the four types used in this study were damaged by impact. However, we were able to confirm some strain from the compression sites of both type A and type B. Both type B and type C are expected to have greater dust collection efficiencies than the other models due to their large vibration transmissibility. Moreover, the high vibrational energy is expected to cause rapping damage during its operation. Particularly, in the case of type B, some of the strain was found at the end of the compression site. The coupling schemes of both type C and type D are out of vibration transmissibility. On the other hand, the ability to maintain straightness and solidity of the side is regarded as outstanding and stable. Type D has outstanding on-site workability, considering the presence of locking, structural stability, and work conditions. From these experiments, we determined that type C is the most ideal connection method of discharge electrode, considering its construction period of renovation. Type C is inferior to type D with regard to on-site workability. However, type C has outstanding dedusting transmission with regard to the straightness, solidity maintenance, and vibration of shearing stress.
The result of a small electrostatic precipitator which is in order to decrease indoor air pollution for optimal efficiency was shown as follows.
Although the closer distance between the discharge electrode and dust collecting electrode shows the better throughput efficiency by forming strong electrostatic Field, it does not have profound impact in case of optimal dust collecting area.
G.P(gas passage) which is the distance from dust collecting electrode to dust collecting electrode is a crucial factor to decide dust collecting efficiency. The narrower distance of G.P shows the better throughput efficiency whereas it decreases when the distance is too narrow since sparks ensue by increasing the capacity of electrostatic charging system 5 mm regards as optimal efficiency in this experiment.
Although the higher voltage shows the higher dust collecting efficiency overall, the experiment was not able to keep performing since the sparks which decrease dust collecting efficiency ensue over 40 kV. The efficient and safe voltage state is considered 3.6 kV in this experiment.
The most crucial factor for dust collecting efficiency of an electrostatic precipitator which is in order to decrease indoor air pollution is applied voltage. In addition, optimal raw gas flow rate(2.4 m/sec) is more important factor than the excessive increase of dust collecting area.
The main purpose of this study was to investigate the characteristics of cylindrical electrostatic precipitator with centrifugal effect in viewpoints of pressure drop and collection efficiency, experimentally. The experiment was carried out for the analysis of current-voltage, pressure drop and collection efficiency with various experimental parameters such as the applied voltage, inlet velocity, inlet size and inlet type(upper and bottom), etc. In the results, the pressure drops were estimated as 27∼54, 34∼63㎜H2O for inlet size 15㎜×3O㎜ and 30㎜×60㎜, respectively. The collection efficiencies were shown over 99% with the small inlet size(15㎜×30㎜) for the applied voltage 40㎸, inlet velocity(15∼21m/s), and 51∼89% with the large inlet size(30㎜×60㎜). Moreover, in the applied voltage 0㎸ and inlet size 15㎜×30㎜, the collection efficiency induced by centrifugal force was represented as about 35% with inlet velocity 15∼21m/s.
This study has been carried out to investigate Electrostatic Precipitator`s(ESP) performance enhancement and removal efficiency of fine particle according to (NH_4)_2SO_4 injection rate.
The following conclusions are derived from the these test results :
1)For plant condition cases, according to the variation of concentration agent [(NH_4)_2SO_4] - 10ppm, 20ppm, 30ppm, 40ppm - ESP`s collection efficiency was increased to 97.74%, 98.95%, 99.04%, 99.47%, when inlet dust loading was 2g/㎥. And when inlet dust loading was 3g/㎥, that was increased to 98.19%, 99.16%, 99.23%, 99.58%.
2)It is seen from this experiments that the increasing 30ppm concentration of (NH_4)_2SO_4 increase the collection efficiency and fine particle emission control.
This study was carried out to investigate the collection Efficiency of mass in collector step at the different of physical gas characterization. This work has focused on the dependence of the collection efficiency of mass in the collector zone of a two-stage set up field with gas temperature T and the dew point tmeperature. To identify the dependence of the mass collection efficiency on the grounded plate of the collector zone M_P,k by the specific electric resistance of dust ρe and the relative humidity φ, 20 attempts have been made with three different gas temperature (50℃, 80℃, 110℃) at different dew point. At the specific electric resistance of dust ρe=10^6Ωm which relative humidity corresponds to φ> 15%, a easy rise of the grounded plate secluded dust mass share was measured again. As the result of the higher cohesion imprisonment power due to the adsorbtion of particle, the rise of the relative humidity developed on the particle surface. Therefore, the collection efficiency of mass was not predominant the high temperature T in the collector zone, neither was the pecific ellectric resistance of dust dependent.