검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 180

        41.
        2010.02 구독 인증기관 무료, 개인회원 유료
        We used a conventional activated sludge process to treat a paper wastewater, and then the effluent was treated with an ozone oxidation process as advanced process to remove non-degradable materials. It was found that the removal efficiency rates of the organic matter has been rapidly increased initially, and then it was almost constant after this period. The concentration of ozone should be recommended to maintain approximately 8.3 mg/L during this operation to keep the CODmn value below 100 mg/L and ozone contact time longer than 60 min.
        4,000원
        42.
        2009.02 구독 인증기관 무료, 개인회원 유료
        In this study, disinfection effect of coliform group treated with ozone was analyzed for the effluent discharging from activated sludge treatment process in hospital wastewater treatment plant. Based on these results, it aims to get basic data to establish the disinfection facility in hospital wastewater treatment, suggesting affecting factors according to hydraulic retention time of the activated sludge process and design basic factors necessary to ozone disinfection. Removal efficiencies of coliform group for the effluent according to HRT such as 4hr, 8hr, 12hr were analyzed using a lab-scale activated sludge process, respectively. To decay the microorganism regulates the CT value multiplied disinfectant concentration by contact time. CT value is highly correlated with a removal efficiency of coliform group and according to increasing an injected ozone concentration, the CT value was increased.. When HRT was 4, 8, 12 hours , CT value takes place at minimum condition 50, 40, 334 mg/L-min, respectively.
        5,100원
        43.
        2008.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        자연유기물을 처리하는 혼합 오존-세라믹 한외여과 수처리 시스템에서 막의 운전조건과 처리수의 화학적 조성이 세라믹 막의 투과플럭스에 미치는 영향을 연구하였다. 오존주입량, 막간압력 그리고 교차흐름속도를 포함한 운전조건의 영향을 관찰한 결과, 막의 투과플럭스는 오존주입량과 교차흐름속도가 증가할수록 그리고 막간압력이 감소할수록 증가하였다. 오존주입으로 인한 막오염의 감소는 교차여과에서 오존기체방울에 의해 발생하는 오염물질의 물리적인 역수송보다는 촉매 금속산화물로 이루어진 세라믹막 표면에서 발생하는 오존과 자연유기물간의 화학반응에 의한 영향에 더욱 의존할 수 있음을 확인하였다. 그러나 이와 같은 막오염의 감소는 상대적으로 높은 막간압력을 적용 시 줄어드는 경향을 나타내었다. 모델 자연유기물을 이용하여 실험한 결과, 높은 pH에서는 칼슘의 첨가로 인해 투과플럭스가 급격하게 감소하였으나 상대적으로 낮은 pH에서는 투과플럭스 감소에 대한 칼슘의 효과는 저하되었다. 혼합 오존-세라믹만 시스템에서 연속적인 오존주입은 세라믹막 표면에서 발생하는 촉매오존산화에 의한 자연유기물의 분해로 운전 초기 막의 투과플럭스의 감소 후 궁극적으로는 막의 투과플럭스를 회복시킬 수 있음을 확인할 수 있었다.
        4,000원
        44.
        2008.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study observed the upper tropospheric ozone enhancement in the northern Atlantic for the Aerosols99 campaign in January-February 1999. To find the origin of this air, we have analyzed the horizontal and vertical fields of Isentropic Potential Vorticity (IPV) and Relative Humidity (RH). The arch-shaped IPV is greater than 1.5 pvus indicating stratospheric air stretches equatorward. These arch-shaped regions are connected with regions of RH less than 20%. The vertical fields of IPV and RH show the folding layer penetrating into the upper troposphere. These features support the idea that the upper tropospheric ozone enhancement originated from the stratosphere. Additionally, we have investigated the climatological frequency of stratospheric intrusion over the tropical north Atlantic using IPV and RH. The total frequency between the equator and 30˚N over the tropical north Atlantic exhibits a maximum in northern winter. It suggests that the stratospheric intrusion plays an important role in enhancing ozone in the upper troposphere over the tropical north Atlantic in winter and early spring. Although the tropospheric ozone residual method assumed zonally invariant stratospheric ozone, stratospheric zonal ozone variance could be caused by stratospheric intrusions. This implies that stratospheric intrusion influences ozone variance over the Atlantic in boreal winter and spring, and the intrusion is a possible source for the tropical north Atlantic paradox.
        4,000원
        46.
        2008.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 포도의 저장성을 향상시킬 수 있는 방법을 모색하기 위하여 'Sheridan'과 'Muscat Bailey A' 품종을 전해산성수 가습처리와 오존수 살균처리 및 전해산성수 살균처리하여 0±1℃에서 90±2%의 상대습도에서 60일간 저장하면서 포도의 품질 특성을 조사하였다. 모든 처리구에서 대조구에 비하여 저장성이 향상된 것을 알 수 있었으며, 중량감모율, 비정상과 발생률, 탈립율, 당도 및 진균수 억제 효과는 처리구별로 무처리구에 비하여 전해산성수 가습처리하여 포도를 저장하였을 때 중량감모율이 가장 적게 변화하여 좋은 효율을 나타내었고, 오존수 살균처리 및 전해산성수 살균처리 방법에서 비정상과 발생률, 탈립율, 당도 및 진균수에 대한 억제 효율을 나타내었는데, 오존수 살균방법보다 전해산성수 살균방법에서 높은 효과를 나타났다. 유리당과 총산 함량은 저장기간의 증가에 따라 약간의 감소를 보였으며, 과피의 anthocyanin 함량도 약간 증가하였다. 본 실험결과 전해산성수 가습방법과 살균방법이 우수한 효과를 나타냄을 확인할 수 있었다.
        4,200원
        47.
        2007.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study was surveyed to evaluate and recognize the distribution characteristics of indoor air pollutants(IAPs) such as the total volatile organic compounds(VOCs), formaldehyde(HCHO), PM10, carbon dioxide(CO2), nitrogen dioxide(NO2), ozone(O3) and radon in 10 elementary schools located in urban, rural, and industrial complex area from November 2005 to February 2006. The average concentration of IAPs were 117.9㎍/㎥ as in PM10, 1,971ppm as in CO2, 486.6㎍/㎥ as in TVOC. These chemical's concentration was exceeded the indoor air standards of the Department of Education in Korea. The indoor concentrations of ozone and toluene was lower than that of outdoor and other pollutants showed the opposite tendency. In schools located industrial complex area, the outdoor concentration of TVOC was higher than that of urban and rural area. Based on the results above, PM10, CO2, TVOC have to be in the order of priority to improve the indoor environment in school. Also it should be performed in the detailed survey considered by the seasonal variation because this study showed cross-sectional results.
        4,000원
        48.
        2006.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In Korea, the ozone profiles have been acquired by using ozonesonde at Pohang station of the Korea Meteorological Administration (KMA) since 1995. These ozone soundings were performed at 0500 UTC on a weekly basis (every Wednesday) in a clear sky. The ozonesonde is equipped with the model 5A ECC sensor, which is one of the most common ozonesonde systems. There have been no attempts to evaluate the Pohang ozonesonde profiles compared with satellite. This paper will provide the first evaluation results for the ozonesonde profiles against HALogen Occultation Experiment (HALOE) measurements over Korea. During 1995-2004 periods, a total of 450 and 188 ozone profiles were obtained from the ozonesonde measurements from HALOE measurements over Korea, respectively. Hence, a total of 34 coincident profile pairs are extracted. Among those total profiles, 26 profiles from ozonesonde are compared against nearly coincident HALOE measurements in time and space. For ozone profiles, the results of statistical analyses showed that the best agreement between two measurements occurs in the 20-25 km and 30-35 km region, where the mean and RMS percent differences are less than ±5 and 14%, respectively. For temperature profiles, the mean and RMS percent differences in 20-25 km region are estimated to be about -0.1 and 1.7%, respectively. According to the scatter plots between two measurements, ozone data are strongly correlated each other above 20 km altitude range with more than 0.8 correlation coefficients. It is found that the altitude (pressure level) differences between two measurements would mainly lead to the discrepancy (over 40% below 18 km) below 20 km in ozone profiles.
        4,000원
        49.
        2006.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Ozone has become a significant pollutant not only outdoors but also indoors. The ozone emission test was conducted for the sum of forty five air cleaners selected in the online shops and department stores. Negative ion emission test was also conducted for the selected fifteen ones which had the function to generate negative ions. Filter-type and complex type air cleaners emitted ozone less than 0.05 ppm, the standard of indoor ozone emission of air cleaner. Wet type ones emitted no ozone. In the case of ionizer type, 66.7% in the nine ones emitted ozone about 1.4~10 times larger than 0.05ppm. Most of air cleaners used a pin corona discharge emitted large amount of ozone. Those which used carbon fiber emitted little ozone in spite of generating a lot of negative ions.
        4,200원
        52.
        2005.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 복사전달모델을 통하여 9.7μm오존 흡수대에 미치는 오존 및 열적(i.e., 지표 온도) 효과를 각각 조사하였다. 또한 오존주의보가 수도권 지역(37.2-37.7 N, 125.7-127.2 E)에 발령되었던 2003년 4일에 대한 위성(MODIS Aqua; ECT 13:30) 및 지상 오존(79개 관측소)의 동시 관측 자료를 기초로 지상 오존에 대한 원격탐사 방법을 제시하였다. 여기서 구름 효과를 제거하고 오존 연직 분포를 분석하기 위하여 종관기상 자료도 사용하였다. 주어진 오존 농도(327~391 DU)에 대하여 산출된 9.6μm에서의 상향 복사휘도는 표면온도 Ts = 290 K에서 5.52~5.78Wm-2sr-1, 그리고 Ts = 325 K에서는 9.00~9,57Wm-2sr-1이었다. 따라서 오존 흡수 세기(i.e., 11μm와 9.7μm 밝기온도 간의 차; T11-9.7)를 이용한 오존 원격탐사 시에 세기 변화에 대한 순수한 오존 효과는0.26Wm-2sr-1/64 DU, 그리고 열적 효과는 0.31Wm-2sr-1/35 K이었다. 본 연구에서는 흡수 세기와 지상 관측 간에 유의적인 상관을 보이는 경우에 대하여 적외선 위성 관측에서 지상 오존을 원격탐사하는 경험식을 유도하였다. 유도된 지상 오존 농도와 관측값과의 상관은 49~63%로 유의수준 1%에서 유의미하였다. 경험식을 개선하기 위하여는 지상 오존 대신에 대류권 오존 자료를 사용하고, 성층권 오존 변화도 고려하는 후속 연구가 요구된다.
        4,600원
        53.
        2005.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        TOMS 월별 오존전량의 전구 자료를 이용하여, 두 기간(전기: 1979-1992년, 후기: 1997-2002년)에 대한 오존전량 추세 및 시공간 변동을 지역과 해륙 분포에 따라 상호 비교하였다. 전기에 비하여 후기의 오존전량이 0-20 N 일부 지역을 제외하고 전지구적으로 10 DU 정도 감소하였다. 오존전량의 추세는 전구적으로 전자기간에 감소(-6.30 DU/decade)를 나타냈다. 후자 기간의 오존 증가 경향은 열대 지역에서 현저하였다. 1997-2002년 기간의 오존전량에 대한 경험직교함수 분석은 준2년 진동(QBO), 준3년 진동(QTO), 엘니뇨(ENSO), 그리고 화산폭발과 관련된 시공간 변동을 반영하였다. 열대 지역에서 대류권 오존의 연직 분포는 동서방향에서 파수 1의 형태를 보였다. 본 연구는 기후 및 환경변화와 관련된 성층권과 대류권 오존 변화의 원인 규명에 도움을 줄 수 있다.
        5,400원
        54.
        2004.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 논문은 강릉과 원주지방의 오존의 일변화의 특성을 분석하였다. 원주지방의 오존의 일변화는 대도시 지역에서 관측되어지는 오후에 최대치, 일출부근에 최소치를 보여주고 있다. 그러나 강릉지방의 일변화에서는 오후에 최대치를 보여주나 새벽 3시경이 2차 극값이 관측되어졌다. 3차 극값의 경우 오후 최대 값보다 높은 값이 종종 관측되어졌다. 이와 같은 새벽에 발생하는 오존 상승은 일년 내내 관측되어졌으나 그 양과 범위에서 봄철이 가장 뚜렷하였다. 이와 같은 새벽 오존 상승에 대한 원인을 알아보기 위하여 기상인자와 오존의 상관관계와, HYSPLIT모델을 이용하여 공기의 기원을 조사하였다. 새벽 오존 농도 상승이 나타나는 날은 바람이 강하고 온도가 상대적으로 높은 날이었다. 새벽오존 농도 상승이 일어날 때 모델을 이용한 공기의 기원을 분석해본 결과 서풍이 불면서 하강운동이 동반한 경우였다. 이러한 분석결과는 편서풍이 강하게 부는 봄철에 대도시가 밀접한 강릉의 서쪽 지역에서 이동되어온 오존의 영향에 의한 것으로 사료되어진다. 이런 경우 밤에도 바람이 강하게 불어 강력한 혼합현상에 의해 오존이 풍부한 대기 상층의공기가 하부로 유입되면서 지표 부근 오존의 양이 증가한 것으로 보인다.
        4,000원
        55.
        2004.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The use of natural paint for the application to walls and furnishings is now increasing to improve indoor air quality, thereby the natural paint could be a significant source of biogenic volatile organic compounds (BVOCs) in indoor environments. Recent studies have shown that gas-phase reactions between terpenes and ozone can generate sub-micron size particles and toxic volatile organic compounds such as aldehydes and ketones. In this research, we have studied the formation of particles and secondary organic compounds during the reaction of ozone with terpenes emitted from commercial natural paint. The paint applied onto stainless steel was dried and oxidized in a teflon chamber. Two monoterpenes (α- and β-pinenes) were identified by FTIR and GC/MS. Several tests were performed to evaluate the effects of ozone concentration on particle formation. Increased ozone levels significantly affect the increase of particle number concentration (monitored with SMPS), which results in the increase of particle counts ranging from 8,000 to 70,000 particles/㎤. Gas-phase products such as formaldehyde, acetaldehyde, acetone + acrolein, and propionaldehyde were identified during the terpene/ozone reactions by HPLC. These compounds are potential hazardous chemical compounds having harmful health effects to animals and plants. The results obtained from this study provide an insight on the adverse effect of eco-friendly natural product on indoor air quality (IAQ).
        4,800원
        56.
        2004.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Decomposition of ozone at room temperature was investigated by comparing between commercial monolithic ozone decomposition catalyst (ODC, MnO2) filter and monolithic photocatalyst (TiO2) filter. The effects of residence time, UV (ultraviolet, A type) irradiation, and upstream ozone concentration on the ozone conversion were discussed. UV ray was irradiated using four BLB (black light blue) lamps (λ: 310∼ 400nm) of constant intensity. The upstream concentration of ozone was controlled by an electrostatic ozone generator. For ODC performance, the presence of UV irradiation slightly affected initial ozone conversion compared with no UV irradiation condition. However, for photocatalyst, the ozone was highly decomposed in the presence of UV irradiation. Long time performances of the both catalysts were evaluated by a real-time ozone monitoring system during 120 hours. The results show that the UV irradiation enhanced the ozone conversion for the both catalysts.
        4,300원
        58.
        2002.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구에서는 1997년부터 1999년 3년 간 대구광역시의 시간별 O3 농도 자료와 기상자료를 분석하여, 대구시의 고농도 오존 발생 일에 나타나는 기상학적 특성을 알아보고자 한다. 고농도 오존 발생 일의 선정은 우리나라 환경기준치인 1시간 평균 오존 농도 100ppb를 초과한 지점이 대구시의 6개 측정 지점 중 한 지점이라도 있는 경우로 정했다. 고농도 오존 발생 일은 13일이었으며, 5월과 9월이 가장 그 빈도가 높았다. 고농도 오존 발생 일의 하루 평균 최대 오존 농도는 81.6ppb이었으며, 8시간 평균 농도는 58.6ppb이었다. 이는 대구의 오존 오염이 연속적으로 그리고 광범위하게 일어났고 있음을 의미한다. 하루 최고 오존 농도는 일사량, 최고 온도와 양의 상관을 보였으며, 상대 습도, 풍속, 구름양과는 음의 상관을 보였다. 일사량과의 상관계수가 0.45로 가장 높았다. 고농도 오존 발생 일의 기상 값과 그 날을 포함하는 월평균 값과의 차이를 보면, +1.58hPa(해면 기압), +3.45˚C(최고 기온), -5.69%(상대 습도), -0.46ms-1(풍속), -1.79(구름양), +3.97MJm-2(일사량)을 각각 보였다. 이는 0700∼1100LST사이의 높은 일사량, 낮은 풍속, 무강수가 고농도 예측의 중요특징임을 나타낸다. 이는 이 시간의 정체와도 연관이 있다.
        4,300원
        59.
        2000.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        전지구(全地球)에 대한 오존전량과 반사율의 경년(經年) 변화를 조사하기 위하여 1979-92년 기간의 Nimbus-7/TOMS 자료의 월평균과 그 아노말리 값을 사용하였다. 여기서 대기 열적 변화에 따른 오존의 경년 변화를 분석하기 위하여 TOMS 자료 외에 위성관측 MSU채널4(하부성층권) 자기온도와 두 개의 대기대순환 모델(NCEP, GEOS) 재분석 온도를 이용하였다. 또한 대기의 열적 및 강수(구름) 변화에 따른 반사율의 경년 변화를 분석하기 위하여는 MSU 채널1(하부 대류권)밝기온도를 이용하였다. 오존전량의 시계열은 뚜렷한 계절 변화와 함께 전구적으로 감소 경향(-6.3±0.6 DU/decade)을, 그리고 엘니뇨보다는 화산폭발이 있었던 기간에 더 뚜렷한 변동을 보였다. 오존전량과 위성관측 및 모델 재분석의 하부 성층권 온도는 1980-92년 기간의 경년 변화에 있어서 서로 양의 상관(0.2-0.7)을 보였다. 반사율은 같은 기간에 전구적으로 다소 증가 경향(0.20±0.06 %/decade)을 보였으며 1982-83년, 1991-92년의 엘니뇨 특징을 잘 반영하였다. 열대 지역에서의 반사율의 연주기 변동은 양반구의 고위도에 비하여 작게 나타났으며, 이는 아열대 고압대 및 열대 용승 지역에서 대기 침강으로 인하여 구름이 소산되거나 하층운의 발달로 인하여 낮은 반사율과 함께 그 변동도 작기 때문인 것으로 추정되었다. 전구에 대한 반사율과 MSU 하부 대류권 온도는 경년 변화에 있어서 서로 음의 상관(-0.9)을 보였으나, 대류활동이 활발한 열대 해양에서는 낮은 양의 상관(0.2)을 보였다. 이러한 양의 상관은 해양에서 구름 및 강수의 증가에 따라 채널1 밝기온도를 증가하게 하는 마이크로파 방출율의 효과를 반영하였다. 오존과 하부 성층권 온도 사이에, 그리고 반사율과 하부 대류권 온도 사이에 존재하는 유의적인 상관은 오존 및 반사율의 위성관측 자료가 기후변동에서의 피이드백 작용을 이해하는데에 유용하게 사용될수 있음을 본 연구는 제시한다.
        4,900원
        60.
        2000.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        상용 고분자막으로 많이 사용되는 Polysulfone(PSF)을 오존으로 처리하여 기체의 투과 및 분리특성을 조사하였다. 고분자막의 오존처리는 chamber 내부에 막을 설치하고 약 5vol.%의 오존을 포함한 산소를 chamber에 연속적으로 공급하면서 일정시간 동안 오전처리를 수행하였다. PSF막의 선택도는 오존처리시간에 따라 증가하였으며 적정 오존처리 시간은 1.5시간이면 충분한 것으로 조사되었다. 그리고, 오존처리에 의한 He/N2, H2/N2, O2/N2, CO2/CH4등의 선택도의 증가는 분자크기가 큰 N2나 CH4의 투과도의 감소에 기인하며 분자크기가 작은 기체의 투과도의 감소는 매우 작은 것으로 나타났다. 오존처리에 의한 선택도의 증가는 오존이 PSF 고분자를 부분적으로 산화시키고 이때 생성된 산소복합체들이 PSF의 자유부피를 감소시키기 때문으로 생각된다.
        4,000원
        1 2 3 4 5