검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 587

        101.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, measuring instruments for SHM of structures has been developed. In general, the wireless transmission of sensor signals, compared to its wired counterpart, is preferable due to the absence of triboelectric noise and elimination of the requirement of a cumbersome cable. However, the low-cost wireless MEMS sensor has high noise density and transmits the signal wirelessly, so data transmission delay occurs during measurement. Therefore, the footbridges that was previously measured by a mobile phone in 2014 was remeasured using G-Link-200, iPad and iPhone to compare their performance.
        4,000원
        102.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적 : 본 연구는 완곡추적 안구운동과 경부신전근 진동자극법의 결합중재가 만성 뇌졸중 환자의 편측무시와 일상생활활동 수행에 미치는 영향을 확인하는 것이다. 연구방법 : 본 연구는 발병 후 6개월 이상 지난 3명의 뇌졸중 편측무시 환자를 대상으로 하였으며, 단일대상연구 방법 중 ABAC디자인으로 연구를 진행하였다. 연구는 기초선(A1) 1주, 중재기(B) 2주, 기초선(A2) 1주, 그리고 중재기(C) 2주로 총 6주간 진행되었으며, 중재기(B)에서는 완곡추적 안구운동(Smooth Pursuit Eye Movement; SPEM)의 단일중재를, 중재기(C)에서는 경부신전근 진동자극법(Neck Muscle Vibration; NMV)과 SPEM의 결합중재를 실시하였다. 평가는 매회기 선 나누기 검사와 벨 테스트(Bells test)를 실시하였으며, 한국판 캐서린 버지고 척도(Korean-Catherine Bergego Scale; K-CBS)와 한국판 일상생활활동 중심 작업기반 신경행동 평가(Korean version of ADL-focused Occupation-based Neurobehavioral Evaluation; K-A-ONE)를 기초선(A1)의 첫 회기와 각 중재기의 마지막 회기에 시행하였다. 결과 : 연구결과 SPEM과 NMV를 단일 또는 결합하여 적용하였을 때 편측무시의 지필검사(선 나누기 검사와 벨 테스트)와 관찰적 검사(K-CBS와 K-A-ONE)에서 편측무시가 개선됨을 확인하였고, 특히 결합중재시에 더 효과가 좋았던 것으로 나타났다. 그리고 편측무시가 개선됨에 따라 일상생활활동의 수행(K-A-ONE)에서도 향상을 보였는데, 편측무시 환자의 일상생활을 저해하는 신경행동 손상은 편측무시 뿐만 아니라 공간관계나 마비와 같은 손상 등이 영향을 미치는 것으로 나타나 다양한 신경행동 손상의 중재를 포함하는 포괄적인 재활프로그램을 계획해야함을 확인하였다. 결론 : 본 연구를 통해 SPEM과 NMV의 결합중재가 만성 뇌졸중 환자의 편측무시를 감소시키고 일상생활 활동 수행을 향상시키는데 효과적인 중재라는 것을 확인하였다.
        4,500원
        103.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Yangjindang house, which is located in Sang-ju province of South Korea, is one of the special Hanok structures dated back to Joseon dynasty. This study aims to examine structural safety of the Yangjindang wood frame building considering dynamic parameters such as the natural frequency and damping ratio. The numerical model of the wood frame building is implemented using Midas Gen, especially the wood joint where column and beam were connected. The behavior of the actual frame building was compared with the modeling results. In addition, structure responses such as shear force, axial force, flexural moment and deflections were calculated and compared with the allowable limits. Numerical results show that, generally, despite of some local members shear failure, Yangjindang’s structural response does not exceed the limitation according to current standards.
        4,000원
        105.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Along with industrial development, various architectural structures have become bigger and higher, leading to an expansion in the size and capacity of construction equipment. And with the development of public transportation, the use of subways as a means of transportation in the city center is increasing, so that vibrations and structural noises are emerging as a new environmental issue. Considering that architectural structures may be used from several decades to hundreds of years after the time of construction, they can be seen as semi-permanent. Due to changes in the vibration-proof polyurethane mats installed in the foundation of these structures, settling may occur and vibration reduction may become inadequate. Therefore, in view of service life, it is necessary to have a high-level standard of reliability and stability. In accordance with this, the Floating Floor System, which uses soft polyurethane foam and can be constructed within a relatively short period of time, has excellent vibration resistant characteristics. It is presented as a great alternative solution to the issue of vibrations caused by subways, railways and building structures. At present, vibration-proof polyurethane mats have been developed up to the same product level as in other advanced countries. However, in the construction of structure foundations, the physical properties of this product and its shape incur changes. If they are installed as such in the structure of a building, it may cause significant impact on stability, requiring that this cause be urgently identified and improved.
        4,000원
        106.
        2019.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: Compared to healthy people, patients with chronic lower back pain have reduced balance abilities which may cause proprioception problems, patients with chronic lower back pain avoid physical activities due to pain, and reduced activity levels lead to muscle weakening, which can further exacerbate pain. Recently, there have been many studies on the use of sensory stimulation; and among these studies, interventions that use vibrational stimulation have shown functional improvements in the patients. Objects: This study examined the effects of a stabilization exercise with vibration stimulation on the balance ability and disability in patients with chronic back pain. Methods: The subjects of the study were 30 persons who were randomly assigned to the experimental group and the control group, with 15 subjects in each. The subjects were evaluated before and after intervention via a balance ability test, the Korean Oswestry disability index (KODI) test, a pain test, and a proprioceptive sensory test. Both groups received general physical therapy. The experimental group performed the stabilization exercise with vibration stimulation, and the control group performed a general stabilization exercise, three times a week for six weeks. Results: After the intervention, both groups showed significant improvements in the balance ability test, the KODI test, the pain test, and the proprioceptive sensory test. The experimental group showed statistically significant, higher improvements than the control group in the balance ability test, the KODI test, and the proprioceptive sensory test. Conclusions: The stabilization exercise with vibration stimulation for patients with chronic back pain has been reported to provide greater functional improvements than the conventional intervention method. Therefore, the stabilization exercise in a vibration stimulation environment could be a useful intervention for patients with chronic back pain.
        4,000원
        107.
        2018.12 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to determine the effects of vibration on primary (e.g. plasma cortisol), secondary (e.g. plasma glucose, aspartate aminotransferase (AST), alanine aminotransferase (ALT), Na+, K+ and Cl- and tertiary (e.g. mortality) stress responses in cultured eel, Anguilla japonica. For this purpose, three groups (including one control group and two stress groups) were set up. The control group was made exposed to vibration corresponding to 48 decibel (dB, V) (produced using electric vibrators) for 15 minutes per hour every day, and the two stress groups was made exposed to vibration corresponding to 58 and 68 dB (V) (produced using the same electric vibrators), equally, for 15 minutes per hour every day. Blood was sampled at day 0 (before starting vibration stress tests, BS), and days 1, 3, 5, 7, 9 and 11 (after starting vibration stress tests). As a result, plasma cortisol showed trend to continuously rise by consecutive stress from 4.1±0.1 ng/ml in BS. In 48 dB group (control), cortisol showed the highest level with 7.6±0.9 ng/ml after 7 days (p <0.05), but at 9 and 11 days was not significantly compared with BS level. In 58 dB group, the cortisol showed the highest level with 43.1±4.8 ng/ml after 1st day. Cortisol of 68 dB group increased significantly during the experimental period (14.4±2.3~32.0± 5.7 ng/ml) (p<0.05). In 58, and 68 dB groups during the experimental period differed significantly compared to 48 group (p <0.05). Glucose in 48 dB were increased from 42.0 ±5.7 (BS) to 52.5±2.1 (1 day), the level was not significantly from 1 to 11 days. Glucose in 58 and 68 dB groups was increased significantly than BS during experimental period (p <0.05). K+ in 68 dB increased significantly (p <0.05) from 2.3±0.2 mE/ql (BS) to 3.3± 0.5 mE/ql at 5 days. In 48 and 58 dB groups during the experimental period differed significantly (p <0.05). Na+ and Cl- levels were not differed significantly during the experimental period. AST and ALT in 58 and 68 dB groups showed trend to continuously rise by consecutive stress. At 7 and 9 days in AST, between 48, 58 and 68 dB groups differed significantly (p <0.05). In 48, 58 and 68 dB groups at 1 day, blood hematocrit increased significantly higher than BS. The 11 days after vibration stress, the mortality in 48, 58 and 68 dB groups was 1.1, 5.1 and 5.8%, respectively. The present results have shown that A. japonica exhibited ''typical'' physiological responses when exposed to chronic vibration stress. These data suggested that chronic vibration stress caused substantial stress in the fish; especially the persisting elevated plasma AST and ALT levels observed would be expected to adverse effect. In conclusion, chronic vibration stress could greatly affects the hematological characteristics in A. japonica.
        4,000원
        108.
        2018.11 구독 인증기관 무료, 개인회원 유료
        Accompanied with the industrial development, and enlarging and heightening buildings, building equipments are also enlarging. These changes are serious to the cause of structure noises. The Floating Floor System which uses the soft foam polyurethane are becoming popular in construction areas for its short construction period and well vibration proof ability, hence it is becoming wide in the marketing volume. We were able to enhance the physical characteristics of the vibration proof polyurethane mat with this study. As a result, we were also able to secure material competitiveness by meeting the requirements of customer satisfaction through enhancement in estimated material lifetime and physical characteristics.
        4,000원
        114.
        2018.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the fatigue and vibration analysis were performed by using Solidworks program to investigate the damage percentage, life cycle and vibration mode depending on the types and positions of load applied to the table (Cases 1, 2, 3, 4). The farther the point of action of the load was, the more the fatigue damage and stability of the table were greatly reduced. The life cycles of Case 1 and 4 were over 100,000 cycles and the fatigue damage was less than 70%. From the vibration analysis, five modes and natural frequencies of Case 1 were confirmed. As the natural frequency increases, the shape of the corresponding mode is predicted not to be deformed.
        4,000원
        115.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Large space structures exhibit different natural vibration characteristics depending on the aspect ratio of structures such as half-open angle. In addition, since the actual large space structure is mostly supported by the lower structure, it is expected that the natural vibration characteristics of the upper structure and the entire structure will vary depending on the lower structure. Therefore, in this study, the natural vibration characteristics of the dome structure are analyzed according to the natural frequency ratio by controlling the stiffness of the substructure. As the natural frequency of the substructure increases, the natural frequency of the whole structure increases similarly to the natural frequency of the upper structure. Vertical vibration modes dominate at 30° and 45°, and horizontal vibration modes dominate at 60° and 90°.
        4,000원
        116.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A base isolation system is widely used to reduce seismic responses of low-rise buildings. This system cannot be effectively applied to high-rise buildings because the initial stiffness of the high-rise building with the base isolation system maintains almost the same as the building without the base isolation system to set the yield shear force of the base isolation system larger than the design wind load. To solve this problem, the mid-story isolation system was proposed and applied to many buildings. The mid-story isolation system has two major objectives; first to reduce peak story drift and second to reduce peak drift of the isolation story. Usually, these two objectives are in conflict. In this study, a hybrid mid-story isolation system for a tall building is proposed. A MR (magnetorheological) damper was used to develop the hybrid mid-story isolation system. An existing building with mid-story isolation system, that is “Shiodome Sumitomo Building” a high rise building having a large atrium in the lower levels, was used for control performance evaluation of the hybrid mid-story isolation system. Fuzzy logic controller and genetic algorithm were used to develop the control algorithm for the hybrid mid-story isolation system. It can be seen from analytical results that the hybrid mid-story isolation system can provide better control performance than the ordinary mid-story isolation system and the design process developed in this study is useful for preliminary design of the hybrid mid-story isolation system for a tall building.
        4,000원
        117.
        2018.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Existing reinforced concrete building structures have seismic vulnerabilities due to their seismically-deficient details resulting in non-ductile behavior. The seismic vulnerabilities can be mitigated by retrofitting the buildings using a fiber-reinforced polymer column jacketing system, which can provide additional confining pressures to existing columns to improve their lateral resisting capacities. This study presents dynamic responses of a full-scale non-ductile reinforced concrete frame retrofitted using a fiber-reinforced polymer column jacketing system. A series of forced-vibration testing was performed to measure the dynamic responses (e.g. natural frequencies, story drifts and column/beam rotations). Additionally, the dynamic responses of the retrofitted frame were compared to those of the non-retrofitted frame to investigate effectiveness of the retrofit system. The experimental results demonstrate that the retrofit system installed on the first story columns contributed to reducing story drifts and column rotations. Additionally, the retrofit scheme helped mitigate damage concentration on the first story columns as compared to the non-retrofitted frame.
        4,000원
        118.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 기능경사재료 보 고유벡터의 변화도 산정을 위한 해석 정식화를 섭동법에 기초하여 제시한다. 불확실인수로는 기능경사재료 보의 중앙면에서 보의 축을 따르는 방향으로 공간적 불확실성을 가지는 재료탄성계수를 택하였다. 두께 방향으로의 탄성계수 변화는 원래의 지수함수를 따르는 것으로 가정하였다. 정식화에서는 고유벡터에 대한 선형 Taylor전개 를 적용한다. 수치예제로는 보의 중앙면에 대하여 대칭인 탄성계수를 가지는 단순지지보를 택하였다. 몬테카를로 해석을 함 께 수행하여 제안한 정식화가 합리적인 결과를 주는지 확인하였다. 해석을 통하여 몬테카를로 해석과 제안된 방법에 의한 결과가 고유모드의 평균 및 표준편차에서 거의 동일한 결과를 제시함을 볼 수 있었다. 제안된 방법을 통하여 고유모드의 표 준편차 형상을 쉽게 산정할 수 있다. 고유모드의 평균중심 변화량은 고유모드의 차수에 관계없이 그 고유모드 대비 한 개가 더 많은 경사 0인 점을 가지게 된다. 또한 평균 고유모드형상으로부터의 변화량은 저차 모드보다 고차모드에서 더 크게 나 타남을 알 수 있었다.
        4,000원
        119.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, measuring instruments for SHM of structures had being developed. In general, the wireless transmission of sensor signals, compared to its wired counterpart, is preferable due to its absence of triboelectric noise and elimination of the requirement for cumbersome cable. However, the research on the tall buildings with relatively small vibration levels is insufficient. Therefore, in this paper, we used the wireless MEMS sensor and iPad to compare and analyze the vibration measurements of three tall buildings and two towers.
        4,000원
        120.
        2018.05 구독 인증기관·개인회원 무료
        As a surface treatment method of concrete pavement in Korea, transverse tinning has initially been applied to improve drainage and friction at first. Since 2003, in order to reduce the noise of concrete pavement, longitudinal tinning have been studied and proved its superiority. Therefore, Korea Expressway Corporation (KEC) has applied this as surface texturing method in concrete pavement from 2008 to the present. However, the lateral vibration during vehicle running has been continuously raised in the longitudinal tinning section, and lots of efforts have been made to solve this problem. Nonetheless, complaints still occur intermittently in some sections. In this research, three sections in which complaints occur and three test sections were chosen to evaluate characteristics of lateral vibration between tire and longitudinal texturing. Based on the literature survey on the correlation between longitudinal texturing and tire, evaluation of the site and FEM analysis of each road surface were carried out. As a result of the analysis, the lateral vibration occurred most frequently in the random tinning section compared to other sections, and it was relatively few at the other improved tinning of the test section. Further studies on various tire types and timing intervals in the future will provide a standard of longitudinal texturing, which will reduce lateral vibration.