검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 174

        61.
        2013.11 구독 인증기관 무료, 개인회원 유료
        In this study, the air pollutant removal such as sulfur oxides was studied. A combination of the plasma discharge in the reactor by the reaction surface discharge reactor Calcium hydroxides catalytic reactor and air pollutants, hazardous gas SOx, changes in gas concentration, change in frequency, the thickness of the electrode, kinds of electrodes and the addition of simulated composite catalyst composed of a variety of gases, including decomposition experiments were performed by varying the process parameters. The experimental results showed the removal efficiency of 98% in the decomposition of sulfur oxides removal experiment when Calcium hydroxides catalysts and the tungsten(W) electrodes were used. It was increased 3% more than if you do not have the catalytic. If added to methane gas was added the removal efficiency increased decomposition.
        4,600원
        62.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Sulfur content of diesel fuel has been cut down to under 10 ppm ULSD (ultra low sulfur diesel) level by environmental regulation with the aim of reducing exhaust emissions. This review discusses the methods and principles of sulfur reduction in diesel and presents an overview of new approaches for ultra-deep desulfurization. The deep HDS (hydrodesulfurization) problems of diesel streams is exacerbated by the inhibiting effect of co-existing aromatics, nitrogen compounds and H₂S. The new approaches to deep desulfurization includes non-HDS type processing schemes such as adsorptive, extractive and oxidative desulfurization.
        4,500원
        63.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        황화수소 등 유황계 악취물질은 매우 낮은 최소감지농도를 갖고 있기 때문에 악취를 제거하기 위해서는 출구에서 악취가 검출되지 않는 적정 부하량에 대해 검토가 이루어져야 한다. 본 연구에서는 활성탄을 가공하여 제작한 습윤 상태의 활성탄소섬유를 이용하여 현장조건과 유사하게 황화합물악취 H2S 10 ppm, MT 3 ppm, DMS 1.5 ppm 3성분의 혼합가스에 대해 약 130일 동안 제거실험을 수행하였다. 그 결과, H2S는 유입부하량을 0.78 g-H2S / kg ACF·d 이하로 설정하여 운전하는 것이 필요하며, MT는 불완전산화 부산물인 DMDS가 출구에서 검출되어 악취를 유발하므로 안정적인 운전을 위해서는 유입부하량을 0.27 g-MT / kg ACF·d 이하로 설정하여 운전하는 것이 필요한 것으로 나타났다. DMS는 유입부하량의 변화에 관계없이 거의 제거되지 않는 것으로 나타났다.
        4,000원
        67.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we present a more electrochemically enhanced electrode using activated carbon (AC)-sulfur (S) composite materials, which have high current density. The morphological and micro-structure properties were investigated by transmission electron microscopy. Quantity of sulfur was measured by thermogravimetric analysis analysis. The electrochemical behaviors were investigated by cyclic voltammetry. As a trapping carbon structure, AC could provide a porous structure for containing sulfur. We were able to confirm that the AC-S composite electrode had superior electrochemical activity.
        4,000원
        68.
        2013.04 구독 인증기관 무료, 개인회원 유료
        In this study, a combination of the plasma discharge in the reactor by the reaction surface discharge reactor complex catalytic reactor and air pollutants, hazardous gas SOx, change in frequency, residence time, and the thickness of the electrode, the addition of simulated composite catalyst composed of a variety of gases, including decomposition experiments were performed by varying the process parameters. 20W power consumption 10kHz frequency decomposition removal rate of 99% in the decomposition of sulfur oxides removal experiment that is attached to the titanium dioxide catalyst reactor experimental results than if you had more than 5% increase. If added to methane gas was added, the removal efficiency increased decomposition, the oxygen concentration increased with increasing degradation rate in the case of adding carbon dioxide decreased.
        4,600원
        69.
        2013.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 연료극 또는 공기극에 함유된 불순물인 황화합물의 도입을 차단할 수 있는 GDL을 제조하여, 이를 평가용 단위전지에 체결하여 H2S와 SO2를 연료극과 공기극에 각각 동시에 공급하여 PEMFC의 성능 저하 및 회복에 관한 연구를 수행하였다. 그 결과 H2S와 SO2의 농도가 증가함에 따라 전지의 성능이 감소하며 특히 10 ppm 이상의 농도에서는 10분 이내에 약 10-15% 정도 성능이 감소하였다. 특히 GDL 표면의 기공이 없는 CN-2 GDL을 체결한 단위전지의 경우 피독에 의한 성능 감소 속도가 더 빠른 것을 확인하였다. 그리고 단위전지 피독 후 황화합물이 혼합되지 않은 순수 가스를 1시간 이상 공급하였을 때 전지의 성능이 GDL의 종류에 따라 90%에서 95% 이상 회복되며 CN-1 GDL의 경우가 가장 회복이 우수하였다.
        4,000원
        71.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        고분자 전해질막 연료전지는 연료극의 연료와 공기극의 공기에 각각 H2S와 SO2이 포함되어 있을 때 그 성능이 심각하게 감소한다. 본 연구는 고분자전해질막 연료전지의 공기극과 연료극에 1 ppm에서 10 ppm의 불순물 가스를 공급하여 전기적 성능측정을 통해 복합적인 황불순물이 단위전지에 미치는 영향을 확인하였다. 최적의 운전조건에서 불순물가스를 피독하였을 때 SO2와 H2S의 농도가 증가할수록 성능이 급격히 감소하였다(단위전지 온도 65℃, 상대습도 100%). 그리고 황의 흡착은 MEA의 백금 촉매층 표면서 일어나며, 불순물 가스가 MEA에 누적되는 것을 확인하였다. 1, 3, 5, 및 10 ppm 4회의 연속적인 피독 후 연료전지의 성능이 0.71 V에서 0.54 V(76 %)로 감소하였다.
        4,000원
        72.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 2년간 '홍로'/M.9 및 '후지'/M.9 품종의 적과를 위한 석회유황합제 및 어유와의 혼합처리 효과를 조사하기 위해 진행하였다. '후지' 1년 차에 있어, 만개 시 석회유황합제 1% 또는 2% 처리는 대조구에 비해 정과 및 액과의 유과수를 감소시켰다. 하지만 2차년도에는 석회유황합제 1% 또는 2% 단용처리에서는 정과 유과수의 차이를 나타내지 않았다. 다만 석회유황합제 1%의 3회 처리에서는 1차년도와 2차년도 모두 유의적인 적과효과를 나타내었다. 석회유황합제 1%의 다중처리는 '홍로'에서 가장 효율적인 적과효과를 나타내었다. 1차년도의 경우, 석회유황합제 1%의 2회 또는 3회 살포가 효과적인 적과효과를 보였으며, 2차년도에서는 석회유황합제 1% 1회처리를 제외하고는 모두 유의적인 적과효과를 나타내었다. 첨가된 어유의 경우 대부분의 경우 석회유황합제의 적과효과를 강화하지 않았다. 본 시험에 사용된 모든 처리구는 과실의 동녹 형성에 악영향을 미치지 않았으며, 또한 '후지' 및 '홍로'의 과실 중량, 경도, 가용성고형물 및 적정산도와 같은 과실품질에 영향을 미치지 않았다.
        4,000원
        73.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to evaluate the relationship with the concentration and odor intensity using the odor sensory method for 4 types of sulfur compounds, ammonia, and trimethylamine. For the measurement, 13 panelists were selected by several criteria through a panel test. Panelists chosen for their closely similar sensitivities provide more reproducible values. The estimation showed that the correlation of the concentration with odor intensity for the 6 compounds can be reasonably expressed by the equation I=Aㆍlog C+B (I: Odor Intensity, C: material concentration, A: material constant, B: constant). The result of this study is suggested to be used as a base data for research on measures to improve the regulation standards for complex odor concentration on site boundary in operation, as well as a correlation between the concentration and odor intensity for the designated foul odor substances, and their characteristics.
        4,000원
        76.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Since 2011, proficiency test for the air dilution olfactory method started in Korea for the evaluation of the authorized odor inspection agencies’ analysis skill. For this purpose, sulfur compounds of PTMs (proficiency test materials) were made and investigated for the application to the proficiency test as a complex malodor sample. Time stability and homogeneity between samples were analysed for the PTM which was made with 10 ppm of DMS and 10 ppm of DMDS. As the results, the stability of sample concentration with GC analysis was shown around 6%RSD through the time of 6~48 hr. In addition, dilution number during the same test period appeared almost stable, less than 6%RSD in air dilution olfactory method. The reproducibility results of four laboratories showed very similar results except one lab which was caused by the elder panel characteristics.
        4,000원
        77.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to evaluate the relationship with the concentration and dilution factor using the Air Dilution Olfactory Method, which is suggested in the Standard Method of Odor Compounds, by measuring dilution factor for 4 types of sulfur compounds, ammonia, and trimethylamine. For the measurement, 13 panelists were selected by several criteria through a panel test. Panelists chosen for their closely similar sensitiviyies provide more reproducible values. The estimation showed that the correlation of the concentration with dilution factor for the 6 compounds can be reasonably expressed by the equation logC=AfㆍlogD+F (Af: material costant, F: constant). The result of this study is suggested to be used as a base data for research on measures to improve the regulation standards for complex odor concentration on site boundary in operation, as well as a correlation between the concentration and dilution factor for the designated foul odor substances, and their characteristics.
        4,000원
        78.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was investigated to determine the contents of sulfur dioxide residues in medicinal herbs in Seoul Yang Nyoung Shi in 2010 (1,522 samples of 189 kinds). Samples were measured by modified Monier-Williams method. Of the total samples, 618 samples (84 kinds) were domestic, and 904 samples (158 kinds) were imported. The content of sulfur dioxide in the domestics showed the range of 0.0 to 1,298.0 mg/kg (average 12.7 mg/kg), while those in imported samples were the range of 0.0 to 3,982.2 mg/kg (average 42.4 mg/kg). The average (mg/kg) amount of sulfur dioxide by parts in medicinal herbs was as follows; Tuber 122.3, Radix 69.3, Rhizoma 37.4, Cortex 33.3, Fructus 8.8, Ramulus 4.9, Semen 4.6, Folium 3.4, Flos 2.7, Perithecium 1.4. Of the total samples (1,522), 52 samples (3.4%) were violated the KFDA regulatory guidance of sulfur dioxide. Among these 52 unsuitable samples, 16samples (7 kinds) were domestic, and 36 samples (23 kinds) were imported. Approximately 88.1% of the total samples was less than 10 mg/kg of sulfur dioxide and 6.3% of the total samples showed more than 30 mg/kg of sulfur dioxide.
        4,500원
        79.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The average sulfur content of crude oil is 2.2%. Coal is about 0.3 to 4.0 percent of the sulfur gases or particles being discharged into the atmosphere through the chimney as 1 to 2% SO3(Sulfur trioxide) and about 95% of the SO2 is reported. SO3 gas, which has many different causes of, as the combustion of sulfur containing fuel during the air due to the excess SO2 gas is oxidized to SO3 gas. Sulfur trioxide emitted from high sulfur heavy oil fired boiler caused white plume in stack and high temperature and cold end corrosion of facilities. So, in order to control sulfur trioxide concentration of Fuel gas in boiler, various of additives are used in other foreign. They are injected to Fuel Oil and consumed in boiler and reduce ash and the conversion rate of sulfur trioxide. In domestic, MgO compounds are used as additives but the total volume of them are made from other foreign company. In this study, MgO compounds were developed with liquid MgO compounds and field application was accomplished. The effect of newly developed chemicals and process were nearly equal to foreign products. In Consequent, the chemicals and process produced by newly developed technology can be substituted for foreign products and reduce the cost of plant operation.
        4,000원
        80.
        2011.10 구독 인증기관·개인회원 무료
        Aschersonia aleyrodis was well-known to be a biological control agent for citrus whitefly, Dialeurodes citri. This entomopathogenic fungus is naturally occurred in organic farming citrus orchards in Jeju. Both lime-sulfur and Bordeaux mixtures are extensively used today to control citrus diseases like citrus melanose and citrus scab, especially in organic farming pest management program. The high concentrated lime-sulfur is also used for pest control such as pink citrus rust mite and scale insects. This study was focused to test the conidial germination and sporulation of Aschersonia aleyrodis on potato dextrose agar (PDA) medium containing different concentrations of two fungicides. The conidia of Aschersonia aleyrodis grown on PDA mixed with commercial bordeaux mixtures, CM150-505, at dilution rate 1:200 (water : bordeaux mixture) were well-germinated but not sporulated at all. On the other hand, Aschersonia aleyrodis did not sporulate and germinate on lime sulfur treated PDA medium even at extremely low dilution rate 1:2,048,000 (water : lime sulfur). However, when the mycelial cells grown at 25o C for at least 7 days at soluble starch-tryptone medium were added to PDA, they were well-sporulated even at high dilution rate 1:100 (water : lime sulfur). This result suggested that the spore mixtures of Aschersonia aleyrodis should be applied to field quite long after lime-sulfur spray.
        1 2 3 4 5