검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 5,768

        121.
        2023.11 구독 인증기관·개인회원 무료
        Bis (2-ethylhexyl)phosphoric acid (HDEHP) is a renowned extractant, favored for its affinity to selectively remove uranium via its P=O groups. We previously synthesized HDEHP-functionalized mesoporous silica microspheres for solid-phase uranium adsorption. Herein, we investigated the kinetic and isothermal behavior of uranyl ion adsorption in mesoporous silica microspheres functionalized with phosphate groups. Adsorption experiments were conducted by equilibrating 20 mg of silica samples with 50 mL of uranium solutions, with concentrations ranging from 10 to 100 mgU L−1 for isotherms and 100 mgU L−1 for kinetics. Three distinct samples were prepared with varying HDEHP to TEOS molar ratios (x = 0.16 and 0.24) and underwent hydrothermal treatment at different temperatures, resulting in distinct textural properties. Contact times spanned from 1 to 120 hours. For x = 0.16 samples, it took around 50 and 11 hours to reach equilibrium for the hydrothermally treated samples at 343 K and 373 K, respectively. Adsorbed quantities were similar (99 and 101 mg g-1, respectively), indicating consistent functional group content. This suggests that the key factor influencing uranium adsorption kinetics is pore size of the silica. The sample treated at 373 K, with a larger pore size (22.7 nm) compared to 343 K (11.5 nm), experienced less steric hindrance, allowing uranium species to diffuse more easily through the mesopores. The data confirmed the excellent fit of pseudo-second-order kinetic model (R2 > 0.999) and closely matched the experimental value, suggesting that chemisorption governs the rate-controlling step. To gain further insights into uranium adsorption behavior, we conducted an adsorption isotherm analysis at various initial concentrations under a constant pH of 4. Both the Langmuir and Freundlich isotherm models were applied, with the Langmuir model providing a superior fit. The relatively high R2 value indicated its effectiveness in describing the adsorption process, suggesting homogenous sorbate adsorption on an energetically uniform adsorbent surface via a monolayer adsorption and constant adsorption site density, without any interaction between adsorbates on adjacent sites. Remarkably, differences in surface area did not significantly impact uranium removal efficiency. This observation strongly suggests that the adsorption capacity is primarily governed by the loading amount of HDEHP and the inner-sphere complexation with the phosphoryl group (O=P). Our silica composite exhibited an impressive adsorption capacity of 133 mg g-1, surpassing the results reported in the majority of other silica literature.
        122.
        2023.11 구독 인증기관·개인회원 무료
        Radiation from spent nuclear fuel (SNF) is one of key factors affecting the dissolution process of SNF and the source term from repository. The dissolution rate of uranium dioxide (UO2) matrix of SNF is expected to control the release of radionuclides from SNF in contact with water under geological disposal conditions. Based on the oxidative dissolution mechanism, the solubility of UO2 can increase significantly if the reducing environment near the fuel surface is altered by water radiolysis caused by radiation from SNF. Therefore, the analysis of water radiolysis products such as radicals (·OH, ·OH2, eaq, ·H) and molecules (H3O+, H2, H2O2) is perquisite for studies on the rate of such dissolution process to determine oxidation/dissolution mechanism and related rate constants. In this study we examined the two-known spectroscopic methods developed for H2O2 determination; one is the luminol-based chemiluminescence (luminol-CL) method and the other is the spectrophotometry using ferrous oxidation-xylenol orange complexation (FOX). Their applicability for quantitative analysis of H2O2 in potential aqueous samples from SNF dissolution studies was evaluated in terms of the analytical dynamic range (ADR), the limit of detection (LOD) and the interfering effects of various metal ions possibly present in real samples. The luminol-CL method exploits the chemiluminescence reaction caused by luminol; when in the presence of a metallic catalyst (e.g., Cu2+, Co2+), luminol emits a blue light (425 nm) at pH 10- 11 in response to oxidizing agents such as hydrogen peroxide. Although a flow-through reaction system is routinely employed to enhance the analytical sensitivity we achieved the ADR up to ~200 μM and LOD < 1 μM by a batch-wise CL detection using conventional cuvette cells and an intensified charge-coupled device (ICCD). Interestingly, it turned out that the interfering effects of other metal ions (e.g., UO2 2+, U4+, Fe2+ and Fe3+) is minimal, which should be advantageous for the luminol-CL method to be employed for samples potentially containing other metal ions. On the other hand, the FOX method spectrophotometrically analyzes H2O2 based on the difference in color (or absorption spectra) of Fe-xylenol orange (XO) complexes. Initially, the Fe2+-XO complex was provided in working solutions at pH 3, which was subsequently mixed with samples having H2O2 and allowed for quantitative oxidation of Fe2+ to Fe3+. Typically, by monitoring the absorbance of Fe3+-XO complex at 560-580 nm (λmax) the ADR up to ~100 μM and LOD ~1.6 μM were achieved. However, it is found that interfering effects from M3+ and M4+ ions are significant; these interfering metal ions can form XO complexes so as to directly contribute the measured absorbance. In contrast, the influence from M2+ ions was found to be negligible. To summarize we conclude that both methods can be applied for H2O2 determination for aqueous samples taken from SNF dissolution tests. However, prior to applying the FOX method the metal ion composition in those samples should be thoroughly identified not to overestimate the H2O2 concentration of samples. More details of underlying chemical reactions in both methods will be discussed in the presentation.
        123.
        2023.11 구독 인증기관·개인회원 무료
        The objective of this study is to investigate the safety awareness and effectiveness of the education and training for employees engaged in radiological emergency organization of the Korea Atomic Energy Research Institute (KAERI). In 2022, the questionnaire for the education satisfaction survey was revised to regulary evaluate the effect of edcation on perceptions of importance on emergency preparedness for nuclear research facilities. In line with, a standard questionnaire was created which covers 3 factors and 9 attributes, and the evaluation indicatior is based on a 5-point Likert scale. In 2023, the education on radiological emergency preparedness was conducted for 235 emergency staff. From May 24 to July 13, 2023, data was collected from a total of 235 emergency response personnels, including 28 new staffs and 207 maintenance staffs. Aa a result of response analysis, it was identified that education for radiological emergency response had a significant correlation with the promoting safety culture. It was found that senior emergency personnel with more years of experience are highly interested in radioactive disaster prevention and actively participate in and training. On the other hand, it was presented that new and less experienced groups tend to have a relatively high scored of the risk perception of nuclear research facilitites. Therefore, it is necessary to improve the practical curriculum in order to increase the participation of junior disaster prevention personnel in education and training, ensuring that they correctly recognize the risk of research facilities. This results are expected to be used to improve the quality of education and drills for radiological emergency response at KAERI.
        124.
        2023.11 구독 인증기관·개인회원 무료
        One of the important components of a nuclear fuel cycle facility is a hot cell. Hot cells are engineered robust structures and barriers, which are used to handle radioactive materials and to keep workers, public, and the environment safe from radioactive materials. To provide a confinement function for these hot cells, it is necessary to maintain the soundness of the physical structure, but also to maintain the negative pressure inside the hot cell using the operation of the heating, ventilation, and air conditioning (HVAC) systems. The negative pressure inside the hot cells allows air to enter from outside hot cells and limits the leakage of any contaminant or radioactive material within the hot cell to the outside. Thus, the HVAC system is one of the major components for maintaining this negative pressure in the hot cell. However, as the facility ages, all the components of the hot cell HVAC system are also subject to age-related deterioration, which can cause an unexpected failure of some parts. The abnormal operating condition from the failure results in the increase of facility downtime and the decrease in operating efficiency. Although some major parts are considered and constructed in redundancy and diversity aspects, an unexpected failure and abnormal operating condition could result in reduction of public acceptance and reliability to the facility. With the advent of the 4th Industrial Revolution, prognostics and health management (PHM) technology is advancing at a rapid pace. Korea Hydro & Nuclear Power, Siemens, and other companies have already developed technologies to constantly monitor the integrity of power plants and are applying the technology in the form of digital twins for efficiency and safety of their facility operation. The main point of PHM, based on this study, is to monitor changes and variations of soundness and safety of the operation and equipment to analyze current conditions and to ultimately predict the precursors of unexpected failures in advance. Through PHM, it would be possible to establish a maintenance plan before the failure occurs and to perform predictive maintenance rather than corrective maintenance after failures of any component. Therefore, it is of importance to select appropriate diagnostic techniques to monitor and to diagnose the condition of major components using the constant examination and investigation of the PHM technology. In this study, diagnostic techniques are investigated for monitoring of HVAC and discussed for application of PHM into nuclear fuel cycle facilities with hot cells.
        125.
        2023.11 구독 인증기관·개인회원 무료
        The first commercial operation of Kori-1, which commenced in April 1978, was permanently shut down in June 2017, with plans for immediate dismantling. The decommissioning process of nuclear power plants generates a substantial amount of radioactive waste and poses significant radiation exposure risks to workers. Radioactivity is widely distributed throughout the primary coolant system of the reactor, including the reactor pressure vessel (RPV), steam generator (SG), and pressurizer. In particular, the SG has a considerable size and complex geometry, weighing approximately 326 tons and having a volume of 400 m3. The SG tubes are known to contain high levels of radioactivity, leading to significant radiation exposure to workers during the dismantling process. Therefore, this study aims to evaluate the workers’ radiation exposure during the cutting of SG tubes, which account for approximately 95% of the total radiation dose in the SG. Firstly, the CRUDTRAN code, developed to predict the behavior of soluble and particulate corrosion products in a PWR primary coolant system, is used to estimate the radioactive inventory in the SG tubes. Based on decontamination factors (DF) obtained in the SG tubes through overseas experience, the expected reduction in radioactivity during the Kori-1 reactor’s full-system decontamination (FSD) process is considered in the CRUDTRAN results. These results are then processed to estimate the radioactivity in both the straight and bent sections of the tubes. Subsequently, these radioactivity values are used as inputs for the MicroShield code to calculate the worker radiation exposure during the cutting of both straight and bent sections of the tubes. The cutting process assumes that each SG tube section is cut in a separate, shielded area, and the radiation exposure is assessed, taking into account factors such as cutting equipment, cutting length, working hours, and working distance. This study evaluates the worker radiation exposure during the cutting of SG tubes, which are expected to have a significantly high radioactivity due to chalk river unidentified deposit (CRUD). This assessment also considers the reduction in radioactivity within the steam generator tubes resulting from the FSD process. Consequently, it enables an examination of how worker radiation exposure varies based on the extent of FSD. This study may provide valuable insights for determining the scope and extent of the FSD process and the development of shielding methods during the dismantling of SG tubes in the future.
        126.
        2023.11 구독 인증기관·개인회원 무료
        In the event of a radiological emergency at a nuclear facility, the exchange of information on the accident situation is very important in the response process. For this reason, international organizations such as the IAEA and the EU operate systems to exchange information in the event of a radiological emergency. In south korea, the emergency response information exchange system (ERIX) developed by KINS is operated for use by the national radiological emergency response organization. The ERIX enables the exchange of emergency response information between organizations such as the government, nuclear operators, local authorities, KINS and KIRAMS. The KAERI has developed the KAERI emergency response information exchange system (KAERIX) for the exchange of accident information and emergency response information between the emergency response organizations of the KAERI in the event of a radiological emergency. This system is web-based using HTML, runs on internal network and is only available to KAERI staff. Recently, as the need for optimizing and upgrading KAERIX has arisen, improvements have been derived. The main improvement is optimizing KAERIX for Microsoft Edge to minimize errors. At present, it is optimized for Internet Explorer, but optimizing it for Microsoft Edge mode has become essential due to Microsoft discontinuing support for Internet Explorer. Another major improvement involves adding functions in ERIX to KAERIX, such as displaying the deletion/ correction status of input information and providing notifications for important information registration. Ultimately, KAERIX will be upgraded and optimized in 2024, reflecting improvements.
        127.
        2023.11 구독 인증기관·개인회원 무료
        The nuclear licensee must ensure that the nuclear or radiological emergency preparedness and response organization is explicitly defined and staffed with adequate numbers of competent and assessed personnel for their roles. This paper describes the responsibilities of medical and support personnel for the medical action of casualties in the event of a radiological emergency at the KAERI. Currently, there is one medical personnel (nurse) in KAERI, and a total of eight medical support personnel are designated for medical response in the event of a radiological emergency. These medical support personnel are designated as one or two of the on-site response personnel at each nuclear facility, operating as a dedicated team of A, B (4 people each). In the event of a radiological emergency, not all medical support personnel are mobilized, but members of the dedicated medical team, which includes the medical support personnel of the nuclear facility where the accident has occurred, are summoned. Medical and support personnel will first gather in the onsite operational support center (OSC)/technical support center (TSC) to prepare and stand by for the medical response to injured when a radiological emergency is declared. They should take radiation protective measures, such as wearing radiation protective clothing and dosimeters, before entering the onsite of a radiological emergency, because injuries sustained during a radiological emergency may be associated with radioactive contamination. In the event of an injury, direct medical treatment such as checking the patient’s vitals, first aid, and decontamination will be carried out by medical personnel, while support personnel are mainly responsible for contacting the transfer hospital, reporting the patient’s condition, accompanying the ambulance, filling out the emergency medical treatment record, and supporting medical personnel. In order to respond appropriately to the occurrence of injuries, we regularly conduct emergency medical supplies education and medical training for medical support personnel to strengthen their capabilities.
        128.
        2023.11 구독 인증기관·개인회원 무료
        South Korea’s first commercial nuclear reactor, Kori Unit 1, was permanently shut down in 2017, and preparations are currently underway for its decommissioning. After the permanent shutdown, the spent nuclear fuel from the reactor core is removed and stored in a spent fuel storage facility. Subsequently, steps are taken for its permanent disposal, and if a permanent disposal site is not determined, it is stored in an interim storage facility (or temporary storage facility). Therefore, the activation criteria for radiation emergency plans vary depending on the movement of spent nuclear fuel and the storage location. In this study, it reviewed emergency plans in the U.S. NRC Regulatory Guide (Draft) titled ‘Emergency Planning for Decommissioning Nuclear Power Reactors’ to determine the requirements for radiation emergency plans needed for decommissioned nuclear power plants. Additionally, by examining emergency plans applied to decommissioning nuclear power plants in the United States, this study identified emergency plan requirement that could be applicable to future decommissioned nuclear power plants in South Korea. This study will contribute to the establishment of appropriate radiation emergency plans for decommissioning nuclear power plants in Korea for providing accurate information on overseas cases and relevant guidelines.
        129.
        2023.11 구독 인증기관·개인회원 무료
        When the parent radionuclide decays, the progeny radionuclide is produced. Accordingly, the dose contribution of the progeny radionuclide should be considered when assessing dose. For this purpose, European Commission (EC) and International Atomic Energy Agency (IAEA) provide weighting factors for dose coefficient. However, these weighting factors have a limitation that does not reflect the latest nuclide data. Therefore, in this study, we analyzed the EC and IAEA methodology for derivation of weighting factor and used the latest nuclide data from ICRP 107 to derive weighting factors for dose coefficient. Weighting factor calculation is carried out through 1) selection of nuclide, 2) setting of evaluation period, and 3) derivation based on ICRP 107 radionuclide data. Firstly, in order to derive the weighting factor, we need to select the radionuclides whose dose contribution should be considered. If the half-life of progeny radionuclides sufficiently short compared to the parent radionuclide to achieve radioactive equilibrium, or if the dose coefficient is greater of similar to that of the parent radionuclide and cannot be ignored, the dose contribution of the progeny radionuclide should be considered. In order not to underestimate the dose contribution of progeny radionuclides, the weighting factors for the progeny nuclides are taken as the maximum activity ratio that the respective progeny radionuclides will reach during a time span of 100 years. Finally, the weighting factor can be derived by considering the radioactivity ratio and branch fraction. In order to calculate the weighting factor, decay data such as the half-life of the radionuclide, decay chain, and branch fraction are required. In this study, radionuclide data from ICRP 107 was used. As a result of the evaluation, for most radionuclides, the weighting factors were derived similarly to the existing EC and IAEA weighting factors. However, for some nuclides, the weighting factors were significantly different from EC and IAEA. This is judged to be a difference in the half-life and branch fraction of the radionuclide. For example, in the case of 95Zr, the weighting factor for 95mNb showed a 35.8% difference between this study and previous study. For ICRP 38, when 95Zr decays, the branch fraction for 95mNb is 6.98×10-3. In contrast, for ICRP 107, the branch fraction is 1.08×10-2, a difference of 54.7%. Therefore, the weighting factor for the dose coefficient based on ICRP 107 data may differ from existing studies depending on the half-life and decay information of the nuclide. This suggests the need for a weighting factor based on the latest nuclide data. The results of this study can be used as a basis for the consideration of dose contributions for progeny radionuclides in various dose assessments.
        130.
        2023.11 구독 인증기관·개인회원 무료
        The demand for transportation is increasing due to the continuous generation of radioactive wastes. Especially, considering the geographical characteristics of Korea and the location characteristics of nuclear facilities, the demand for maritime transportation is expected to increase. If a sinking accident happens during maritime transportation, radioactive materials can be released into the ocean from radioactive waste transportation containers. Radioactive materials can spread through the ocean currents and have radiological effects on humans. The effect on humans is proportional to the concentration of radioactive materials in the ocean compartment. In order to calculate the concentration of radioactive materials that constantly flow along the ocean current, it is necessary to divide the wide ocean into appropriate compartments and express the transfer processes of radioactive materials between the compartments. Accordingly, this study analyzed various ocean transfer evaluation methodologies of overseas maritime transportation risk codes. MARINRAD, POSEIDON, and LAMER codes were selected to analyze the maritime transfer evaluation methodology. MARINRAD divided the ocean into two types of compartments that water and sediment compartments. And it was assumed that radionuclides are transfered from water to water or from water to sediment. Advection, diffusion, and sedimentation were established as transfer process for radionuclides between compartments. MARINRAD use transfer parameters to evaluate transer processes by advection, diffusion, and sedimentation. Transfer parameters were affected by flow rate, sedimentation rate, sediment porosity, and etc. POSEIDON also divided the ocean into two types that water and sediment compartment, each compartments was detaily divided into three vertical sub-compartment. Advection, diffusion, resuspension, sedimentation, and bioturbation were established as transport processes for radionuclides between compartments. POSEIDON also used transfer parameters for evaluating advection, diffusion, resuspension, sedimentation, and bioturbation. Transfer parameters were affected by suspended sediment rates, sedimentation rates, vertical diffusion coefficients, bioturbation factors, porosity, and etc. LAMER only considered the water compartment. It divided the water compartment into vertical detailed compartments. Diffusion, advection and sedimentation were established as the nuclide transfer processes between the compartments. To evaluated the transfer processes of nuclides for diffusion and advection, LAMER calculated the probability with generating random position vectors for radionuclides’ locations rather than deterministic methods such as MARINRAD’s transfer parameters or POSEIDON’s transfer rates to evaluate transfer processes. The results of this study can be used as a basis for developing radioactive materials’ ocean transfer evaluation model.
        131.
        2023.11 구독 인증기관·개인회원 무료
        The operation of nuclear facilities involves the potential for on-site contamination of soil, primarily resulting from pipe leaks and other operational incidents. Globally, decommissioning process for commercial nuclear power plants have revealed huge-amounts of soil waste contaminated with Cs-137, Sr-90, Co-60, and H-3. For example, Connecticut Yankee in the United States produced approximately 52,800 ton of contaminated soil waste, constituting 10% of the total waste generated during its decommissioning. Environmental remediation costs associated with nuclear decommissioning in the US averaged $60 million per unit, representing a significant 10% of the whole decommissioning expenses. Consequently, this study undertook a preliminary investigation to identify important factors for establishing a site remediation strategy based on radionuclide- and site-specific media- characteristics, focusing the efficiency enhancement for the environmental remediation. The factors considered for this investigation were categorized into physical/environmental, socioeconomic, technical, and management aspects. Physical/environmental factors contained the site characteristics, contamination levels, and environmental sensitivity, while socio-economic factors included the social concerns and economic costs. Technical and management factors included subcategories such as technical considerations, policy aspects, and management factors. Especially, technical factors were further subdivided to consider the site reuse potential, secondary waste generation by site remediation, remediation efficiency, and remediation time. Additionally, our study focused the key factors that facilitate the systematic planning for the site remediation, considering the distribution coefficient (Kd) and hydrogeological characteristics associated with each radionuclide in specific site conditions. Therefore, key factors in this study focus the geochemical characteristics of site media including the particle size distribution, chemical composition, organic and inorganic constituents, and soil moisture content. Moreover, the adsorption properties of site media were examined concerning the distribution coefficient (Kd) of radionuclides and their migration characteristics. Furthermore, this study supported the development of a conceptual framework, containing the remediation strategies that incorporate the mobility of radionuclides, according to the site-specific media. This conceptual framework would necessitate the spatial analysis techniques involving the whole contamination surveys and radionuclide mobility modeling data. By integrating these key factors, the study provides the selection and simulation of optimal remediation methods, ultimately offering the estimated amounts of radioactive waste and its disposal costs. Therefore, these key factors offer foundational insights for designing the site remediation strategies according the sitespecific information such as the distribution coefficient (Kd) and hydrogeological characteristics.
        132.
        2023.11 구독 인증기관·개인회원 무료
        KEPCO KPS is the contractor for the full system decontamination (FSD) of Kori Unit 1 and under preparation such as modification, lay out for equipment installation, setting up tie-in/out point for chemical injection and way to pressurize the system, of its successful performance. In this research, KPS introduced how KPS has designed and prepared for the FSD project and how will the chemical decontamination process be implemented. As described in the previous research, chemical decontamination process is planned to be conducted for three cycles and each cycle is consisted of oxidation, reduction, decomposition, and purification. Oxidation and reduction process were conducted at 90°C. Chemical decomposition and purification process were conducted at 40°C due to the damage of IX by the heat. If the decontamination result does not meet the target DF and the dose rate, additional cycle can be conducted. Expected volume of process water for FSD is 200 m3. Three systems have been designated as decontamination targets: reactor coolant system (RCS), residual heat removal system (RHRS), chemical volume control system (CVCS). For the steady flow rate, existed plant equipment such as reactor coolant pump (RCP) will be operated and modifications on some components will be conducted. Due to the limited space for installation, decontamination equipment and other resources are distributed to three different places. KPS designed the layout of equipment installed inside the containment vessel. The layout contains the information of shielding for highly radiated equipment such as IX and filter skid.
        133.
        2023.11 구독 인증기관·개인회원 무료
        The thermal treatment of radioactive waste attracts great attention. The thermal treatment offers lots of advantages, such as significant volume reduction, hazard reduction, increase of disposal safety, etc. There are various thermal technologies to waste. The developed technologies are calcination, incineration, melting, molten salt oxidation, plasma, pyrolysis, synroc, vitrification, etc. The off-gas treatment system is widely applied in the technologies to increase the safety and operation efficiency. The thermal treatment generates various by-product and pollutants during the process. The dust or fly ash are generated as a particulate from almost every radioactive waste. The treatment of PVC related components generates hydrogen chloride, which usually brings corrosion of facility. The treatment of rubber and spent resin generates sulfur oxide, SOx. The treatment of nitrile rubber generates nitrogen oxide, NOx. The incomplete combustion of radioactive waste usually generates carbon oxide, COx. The process temperature also affects the generation of off gas, such as NOx and/or COx. Various off gas treatment components are organized for the proper treatment of the previously mentioned materials. In this study systematical review on off gas treatment will be reported. Also, worldwide experiences and developed facility will be reported.
        134.
        2023.11 구독 인증기관·개인회원 무료
        The primary purpose of high temperature process of radioactive waste is to satisfy the waste acceptance criteria and volume reduction. The WAC offers the guideline of waste form fabrication process. The WAC is defined as quantitative or qualitative criteria specified by the regulatory body, or specified by and operator and approved by the regulatory body, for radioactive waste to be accepted by the operator of a repository for disposal, or by the operator of a storage facility for storage. The main objective of WAC is to protect staff and general public and environment by the containment of radioactive material, limit external radiation level, and prevent criticality. The WAC also offers systematic management of radioactive waste by standardization of waste management operations, facilitation waste tracking, ensure safe and effective operation of operating facilities, etc. Since the high temperature process for radioactive waste is considered in many countries, lots of codes and standards are considered. In many WACs, compressive strength, thermal cycle stability, radiation exposure stability, free liquid, and leachability are evaluation to understand the effect of solidified form to the disposal facility. In this paper, systematical review on waste form will be discussed. In addition, brief result of characterization of waste form will be compared.
        135.
        2023.11 구독 인증기관·개인회원 무료
        In 2017, the permanent shutdown of Kori Unit 1 was decided, marking the initiation of preparations for the decontamination and decommissioning of Kori Unit 1. The dismantling of radiologically contaminated equipment and concrete structures such as the Reactor Vessel (RV), Reactor Vessel Internals (RVI), and the Bio shield is crucial in the nuclear decommissioning process. These components became radiologically contaminated due to nuclear fission reactions occurring in the reactor during its operational period. The RVI dismantling at Spain’s Jose Cabrera Nuclear Power Plant involved the use of mechanical saws and disk cutters to divide it into approximately 430 pieces, taking 16 months to complete. Germany’s Stade Nuclear Power Plant employed mechanical circular saws to segment their RVI into about 170 pieces, which took 30 months to accomplish. Meanwhile, the RVI at Germany’s Wurgassen Nuclear Power Plant was subdivided into approximately 1,200 pieces using a combination of mechanical saws and abrasive water jets, requiring 61 months for completion. Due to the radioactivity in Kori Unit 1’s Reactor Vessel (RV) and Reactor Vessel Internals (RVI), remote-controlled systems were developed for cutting within the cavity to reduce radiation exposure. Specialized equipment was developed for underwater cutting operations. This paper focuses on modeling related to RVI operations using the MAVRIC code. The upper and lower parts of the RVI are classified as low-level radioactive waste, while the sides of the RVI that come into contact with fuel are classified as intermediate-level radioactive waste. Therefore, the modeling presented in this paper only considers the RVI sides since the upper and lower parts have a minimal impact on radiation exposure. Accurate calculations were performed through geometric modeling and radiation dose modeling. These research findings are anticipated to contribute to enhancing the efficiency and safety of nuclear reactor decommissioning operations
        136.
        2023.11 구독 인증기관·개인회원 무료
        The radiological characterization of SSCs (Structure, Systems and Components) plays one of the most important role for the decommissioning of KORI Unit-1 during the preparation periods. Generally, a regulatory body and laws relating to the decommissioning focus on the separation and appropriate disposal or storage of radiological waste including ILW (intermediate level waste), LLW (low level waste), VLLW (very low level waste) and CW (clearance waste), aligned with their contamination characteristics. The result of the preliminary radiological characterization of KORI Unit-1 indicated that, apart from neutron activated the RV (reactor vessel), RVI (reactor vessel internals), and BS (biological shielding concrete), the majorities of contamination were sorted to be less than LLW. Radiological contamination can be evaluated into two methods. Due to the difficulties of directly measuring contamination on the interior surfaces of the pipe, called CRUD, the assessment was implemented by modeling method, that is measuring contamination on the exterior surfaces of the pipes and calculating relative factors such as thickness and size. This indirect method may be affected by the surrounding radiation distribution, and only a few gamma nuclides can be measured. Therefore, it has limitation in terms of providing detailed nuclide information. Especially, α and β nuclides can only be estimated roughly by scaling factors, comparing their relative ratios with the existing gamma results. To overcome the limitation of indirect measurement, a destructive sampling method has been employed to assess the contamination of the systems and component. Samples are physically taken some parts of the systems or components and subsequently analyzed in the laboratory to evaluate detailed nuclides and total contamination. For the characterization of KORI Unit-1, we conducted the radiation measurement on the exterior surfaces of components using portable instruments (Eberline E-600 SPA3, Thermo G20-10, Thermo G10, Thermo FH40TG) at BR (boron recycle system) and SP (containment spray system) in primary system. Based on these results, the ProUCL program was employed to determine the destructive sample collection quantities based on statistical approach. The total of 5 and 8 destructive sample quantities were decided by program and successfully collected from the BR and SP systems, respectively. Samples were moved to laboratory and analyzed for the detail nuclide characteristics. The outcomes of this study are expected to serve as valuable information for estimating the types and quantities of radiological waste generated by decommissioning of KORI Unit-1.
        137.
        2023.11 구독 인증기관·개인회원 무료
        The Derived Concentration Guideline Level (DCGL) is required to release the facility from the nuclear safety act at the stage of site restoration of the decommissioning nuclear power plant. In order to evaluate DCGL, there are various requirements, and among them, the selection of input parameters based on the application scenario is the main task. Especially, it is important to select input parameters that reflect site characteristics, and at this time, a single deterministic value or a probabilistic distribution can be applied. If it is inappropriate to apply a particular single value, it may be reasonable to apply various distributions, and the RESRAD code provides for evaluation using probabilistic methods. Therefore, this study aims to analyze the difference between the application of the deterministic method and the application of the probabilistic method to the area and thickness of the contaminated zone among the site characteristics data. This study analyzed the thickness and area of the contaminated zone, and in the case of thickness, the deterministic method was applied by changing the thickness at regular intervals from the minimum depth considered by MARSSIM to the thickness of the unsaturated zone identified in previous research data. In addition, a probabilistic analysis was performed by applying a distribution to the thickness of contaminated zone. Second, for the area of the contaminated zone, the dose was evaluated for each area in consideration of the areas to be considered when deriving Area Factor (AF), and the resulting change in DCGL was observed. As a result, the DCGL tends to decrease as the thickness increases, and it seems to be saturated when the thickness exceeds a certain thickness. Therefore, It was confirmed that the level of saturated values is similar to that of entering a probabilistic distribution, and in the case of a parameter that is reasonable to enter as a distribution rather than as a single value, it is sufficiently conservative to perform a probabilistic evaluation. In the case of area change, the DCGL evaluation result showed that the DCGL increased as the scale decreased. The magnitude of the change varies depending on the characteristics of each radionuclide, and in the case of radionuclides where external exposure gamma rays have a major exposure effect, the change is relatively small. It can be seen that the change in DCGL according to the area has the same tendency as the AF applicable to the survey unit for small survey units applied in the final status survey.
        138.
        2023.11 구독 인증기관·개인회원 무료
        According to acceptance of radioactive waste, homogeneous waste such as concentrated liquid waste and spent resin must be solidified to reduce radiological hazards and protect public health and the ecology. However, when using a High Integrity Containers (HIC), it is stated that homogeneous waste can be disposed of without applying the solidification test requirements. PCHIC, developed in korea, is composed of polyethylene (PE, interior), polymer concrete (PC, filler), and steel (external reinforcement). Currently, PC-HIC will be used as a packaging container for low-level liquid waste and spent resin waste. PE has a lower shielding efficiency compared to PC, but it offers the economic advantage of lower production costs. Therefore, cost savings can be expected if very low-level waste is packaged and disposed of HIC made only of PE materials (PEHIC). Despite the economical advantage of PE-HIC, PE-HIC has not been used domestically since NRC (Nuclear Regulatory Commission) reported that PE-HIC couldn’t meet the mechanical integrity criteria for radiation exsure. However, according to IAEA (International Atomic Energy Agency) research, it has been reported that mechanical integrity of PE-HIC is not affected when the absorbed dose is below 50 kGy. Therefore, in this study, Radiological impact of VLLW packaged into PE-HIC is evaluated to confirm that the absorbed dose is below 50 kGy, which then be used to assess feasibility of PE-HIC to be used as packaging and disposal container for radioactive waste. Radiological impact of VLLW packaged into PE-HIC is evaluated to confirm that the absorbed dose is below 50 kGy, which then be used to assess feasibility of PE-HIC to be used as packaging and disposal container for radioactive waste. The feasibility of using PE-HIC as packaging-disposal containers for radioactive waste will be reviewed. In this study, the radiation effects of only waste packaged in PE-HIC were considered, and additional assumptions are as follows. - Nuclides subject to radioactivity evaluation: Co-60, Cs-137 - Radioactivity concentration: very low-level radioactive wastel concentration limit - Target waste: waste resin - PE-HIC dimensions: outer diameter: 1,194 mm, height: 1,290 mm, and thickness 88 mm (PCHIC internal PE shape) Considering the above assumption, the exposure rate was evaluated using the MicroShield program. Since the density of PE-HIC in the MicroShield program was assumed as the density of air. The absorbed dose was recalculated through density correction of the derived exposure rate. As a result, it was confirmed that absorbed dose was about 2-3 mGy over 300 years. As a result of dose evaluation by MicroShield, it is judged that the mechanical integrity of PEHIC as an packaging of VLLW can be proved by confirming that the absorption dose irradiated to PE-HIC by internal waste is less than 50 kGy.
        139.
        2023.11 구독 인증기관·개인회원 무료
        The treatment process for Spent Filter(SF) of Kori-1 was developed that includes the following : 1) Taking out by robot system 2) Screening by ISOCS 3) Collection of representative samples using a sampling machine 4) Compression 5) Immobilization 6) Packaging and nuclide analysis and 7) Delivery/disposal. Although the robot system, ISOCS, sampling machine and immobilization facility are essentially required for building the above processing but decision to build the compression system and nuclide analysis system must be made after reviewing the need and cost benefit for their construction. In addition, for effcient SF treatment, it is necessary to determine the nuclide concentration range of the SF to which immobilization will be applied. In this study, a cost benefit analysis was performed on existing and alternative methods for processes related to compression treatment, nuclide analysis and immobilization methods, which are greatly affected by economics and efficiency according to the design. First, although the disposal cost is reduced with reducing the number of packaging drums by compressed and packaged but the expected benefits not be equal to or greater than the cost invested in building a compression system. As a result, non-compressed treatment of SF is expected to be economical because the construction cost of compression system is more expensive than the benefits of reducing disposal costs by compression. Second, a cost benefit analysis of direct and indirect nuclide analysis methods was performed. For indirect analysis, scaling factors should be developed and the drum scanner suitable for the analysis for DAW should be improved. As a result, direct analysis applied grouping options is expected to be more economical than indirect analysis requiring the cost for developing scaling factors and improving the scanner. Third, it is timeconsuming and inefficient to distinguish and collect filters that are subject to be immobilized according to the waste acceptance criteria among the disorderly stored SFs in the filter rooms. If the benefits of immobilization of the SFs selectively are not greater than the benefits of immobilization of all SFs, it can be economical to immobilize all SFs regardless of the nuclide concentration of them. As a result, it is more economical to immobilize all SFs with various nuclide concentrations than to selectively immobilize them. The conclusion of this study is that it is not only cost-effective but also disposal-effective to design the treatment process of SF to adopt non-compressed processing, direct analysis and immobilization of all SFs.
        140.
        2023.11 구독 인증기관·개인회원 무료
        Korea Atomic Energy Research Institute (KAERI) has been operating the Post Irradiation Examination Facility (PIEF) for fuel examinations. The facility has pools and hot cells for handling and examining fuel assemblies and rods. Among the hot cells, the second cell is for measuring rod internal pressure (RIP) and then cutting the rod to make samples for destructive tests. Currently, the cutting machine is broken, so it has to be replaced. Because the existing cutting machine consists of many parts and its size was quite a bit large to handle and treat for the radioactive waste disposal, the disassembly work has been performed to make it smaller using manipulators. The drawings of the cutting machine were reviewed and the disassembly tools were developed considering workability when the work performed at the hot cell using the manipulators. The large parts such as motor, mirror and cable, etc., were able to be disassembled and the machine size became so smaller that it could be easily handled for the disposal.