In conventional construction practices, roof-parapet junction structures inevitably disrupt the insulation installation's continuity, leading to energy loss and thermal bridging. To address this issue, parapet thermal breaks were installed to interrupt the heat flow between the roof and the parapet, effectively preventing thermal bridging and energy loss and thereby reducing overall energy loss in buildings. This study equipped three experimental specimens with the developed parapet thermal breaks to verify their structural performance. These specimens were subjected to unidirectional loading under displacement-controlled conditions. The structural performance of these insulation structures was evaluated by comparing and analyzing the test results with corresponding analytical studies conducted using a finite element analysis program. In addition, five analytical models with varying parameters of the parapet thermal breaks were developed and compared against the baseline model. Consequently, the most efficient shape of the parapet thermal break was determined.
The precast concrete (PC) method allows for simple assembly and disassembly of structures; however, ensuring airtight connections is crucial to prevent energy loss and maintain optimal building performance. This study focuses on the analytical investigation of the shear capacity of precast ultra-high-performance concrete (UHPC) ribs combined with standard concrete PC cladding walls. Five specimens were tested under static loading conditions to evaluate their structural performance and the thermal behavior of the UHPC rib shear keys. Test results indicated that the specimens exhibited remarkable structural performance, with shear capacity approximately three times greater than that of standard concrete. Numerical models were subsequently developed to predict the shear capacity of the shear keys under various loading conditions. A comparison between the experimental results and finite element (FE) models showed a maximum strength difference of less than 10% and a rib displacement error of up to 1.76 mm. These findings demonstrated the efficiency of the FE model for the simulation of the behavior of structures.
The aim of this study is to evaluate the possibility of damage to cultural assets resulting from vibrations generated by construction vehicle traffic. The cultural heritage's natural vibration frequency was determined to be 150Hz by measurement. The damping ratios were calculated as 4.7% using the logarithmic decrement approach and 4.3% using the half-power method. The vibration measurements obtained during vehicle operation indicated that, despite an increase in vehicle velocity of up to 15 km/h, the vibrations remained below the detectable level of 0.13 mm/sec. When the road is curved and the terrain is sloped, a suitable speed for vehicle operation was found to be around 17 km/h, at which point vibrations were seen. The highest recorded vibration amplitude at this velocity was 0.217 mm/sec, which remains below the stringent regulation limit of 2 mm/sec. Thus, it can be concluded that there is no actual harm caused by vibrations.
최근 수십 년 동안, 데이터는 기업 조직 경영의 핵심 요소로 부상하였다. 많은 조직들이 데이터를 활용 하여 전략적인 의사결정을 내리고 시장 변화에 적극적으로 대응하고 있다. 이러한 상황에서 본 연구는 데이터 기반 의사결정 조직 운영과 그에 영향을 미치는 요인을 살펴보고자 한다. 상시적 디지털 전환이 일어나고 있는 현대에 데이터 중심 의사결정은 조직의 성과 향상에 매우 중요한 역할을 한다. 그러나 데 이터 기반 의사결정 조직에 영향을 미치는 선행 요인과 실제로 기업 내에서 데이터 기반 의사결정이 어떻게 일어나는지에 대한 연구는 아직 많이 부족한 실정이다. 본 연구는 기업의 밸류체인 디지털화 정도가 데이터 기반 의사결정 조직 구축에 중요한 영향을 미칠 것임을 가설로 설정하고, 이를 국내 기업 임직원 1,059명을 대상으로 한 설문응답 데이터로 검증하였다. 또한, 본 연구는 데이터 분석 능력을 포함한 디지 털 역량을 갖춘 인재가 데이터 중심 의사결정 조직에 중요한 환경적 요건으로 작용할 수 있음을 고려하 여, 기업의 밸류체인 디지털화와 데이터 중심 의사결정 조직 구축 간의 관계에 디지털 인재 준비도가 미 치는 조절효과를 가설로 설정하고 통계적으로 검증하였다. 본 연구의 결과는 데이터 중심 의사결정 조직 형성과 운영에 대한 이해를 넓히고 기업 조직이 데이터를 효과적으로 활용하여 의사결정을 내리는 과정 에 대한 유용한 시사점을 제공할 수 있다. 실무적 측면에서는 기업들이 자신의 데이터 전략을 개발하고 구현하는 데 중요한 시사점을 제공할 수 있을 것으로 기대한다.
This study aims to evaluate the structural safety of a structural thermal barrier, installed inside the structure of a building and performed the role of a load-bearing element and an insulation simultaneously, contributing to the realization of net-zero buildings. To ensure the reliability of the analysis model, the analysis results derived from LS-DYNA were compared with the experimental results. Based on the results shown through the flexural experiment, the reliability of the thermal cross-section insulation structure model for slabs was validated. In addition, the effect of the UHPC block on the load support performance and its contribution to vertical deflection was verified.
High-temperature oxidation of a Ni-based superalloy was analyzed with samples taken from gas turbine blades, where the samples were heat-treated and thermally exposed. The effect of Cr/Ti/Al elements in the alloy on high temperature oxidation was investigated using an optical microscope, SEM/EDS, and TEM. A high-Cr/high-Ti oxide layer was formed on the blade surface under the heat-treated state considered to be the initial stage of high-temperature oxidation. In addition, a PFZ (γ’ precipitate free zone) accompanied by Cr carbide of Cr23C6 and high Cr-Co phase as a kind of TCP precipitation was formed under the surface layer. Pits of several μm depth containing high-Al content oxide was observed at the boundary between the oxide layer and PFZ. However, high temperature oxidation formed on the thermally exposed blade surface consisted of the following steps: ① Ti-oxide formation in the center of the oxide layer, ② Cr-oxide formation surrounding the inner oxide layer, and ③ Al-oxide formation in the pits directly under the Cr oxide layer. It is estimated that the Cr content of Ni-based superalloys improves the oxidation resistance of the alloy by forming dense oxide layer, but produced the σ or μ phase of TCP precipitation with the high-Cr component resulting in material brittleness.
대용량 화학 및 청정에너지의 운반체인 수소는 석유화학 산업 및 연료전지 등에서 많이 활용되는 중요한 산업용 기체이다. 특히 수소는 주로 증기개질 및 가스화를 통해 화석 연료에서 생성되며 부산물로 이산화탄소가 발생한다. 따라서 고 순도 수소를 얻기 위해서는 이산화탄소를 제거해야 한다. 본 총설에서는 배러 단위[1 Barrer = 10−10 cm3 (STP) × cm / (cm2 × s × cmHg)]로 보고된 이산화탄소로부터 수소를 분리하는 프리스탠딩 고분자 분리막 및 혼합매질 분리막에 초점을 맞추었 다. 최근 보고된 다양한 논문들을 분석하여 분리막의 구조, 형태, 상호 작용 및 제조 방법에 대해 논의하고 구조-물성 관계를 이해하여 향후 더 나은 분리막 소재를 찾는 데 도움이 되고자 한다. 다양한 분리막의 성능 및 특성 검토를 통해 수소/이산화 탄소 분리에 대한 Robeson 성능 한계선을 제시하고, 가교, 혼합 및 열처리 등의 기술을 사용하여 분리 특성을 개선하는 다양 한 혼합매질 분리막에 대해 논의하였다.
In this study, defects generated in the YSZ coating layer of the IN738LC turbine blade are investigated using an optical microscope and SEM/EDS. The blade YSZ coating layer is composed of a Y-Zr component top coat layer and a Co component bond coat layer. A large amount of Cr/Ni component that diffused from the base is also measured in the bond coat. The blade hot corrosion is concentrated on the surface of the concave part, accompanied by separation of the coating layer due to the concentration of combustion gas collisions here. In the top coating layer of the blade, cracks occur in the vertical and horizontal directions, along with pits in the top coating layer. Combustion gas components such as Na and S are contained inside the pits and cracks, so it is considered that the pits/cracks are caused by the corrosion of the combustion gases. Also, a thermally grown oxide (TGO) layer of several μm thick composed of Al oxide is observed between the top coat and the bond coat, and a similar inner TGO with a thickness of several μm is also observed between the bond coat and the matrix. A PFZ (precipitate free zone) deficient in γ' (Ni3Al) forms as a band around the TGO, in which the Al component is integrated. Although TGO can resist high temperature corrosion of the top coat, it should also be considered that if its shape is irregular and contains pore defects, it may degrade the blade high temperature creep properties. Compositional and microstructural analysis results for hightemperature corrosion and TGO defects in the blade coating layer used at high temperatures are expected to be applied to sound YSZ coating and blade design technology.