검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 218

        181.
        2015.02 서비스 종료(열람 제한)
        유지관리를 고려하여 도시철도 자갈도상을 콘크리트 도상으로 교체함에 따라 증가되는 소음진동을 저감하는 방안으로 흡음판을 기존 운행 중인 터널 내부에 부착하는 방안이 다양하게 시도되고 잇다. 기존의 설계에 반영되어 있지 않은 새로운 유지관리, 안전, 화재 등 여러가지 간섭현상이 주요 문제점으로 부각되었다. 국내외 설계기준과 시도된 방안들의 문제점과 시공 및 유지관리를 고려한 요구조건을 비교 검토하여 현실성있는 설치방안을 제한하고자 한다.
        182.
        2014.10 KCI 등재 서비스 종료(열람 제한)
        Carbon dioxide generated from construction materials and construction material industry among the fields ofconstruction is approximately 67million tons. It is about 30% of the carbon dioxide generated in the fields of construction.In order to reduce carbon dioxide in the fields of construction, it is necessary to control the use of fossil fuel consumedand decrease carbon emission by reducing the secondary and tertiary curing generating carbon dioxide in constructionmaterial industry. Therefore, this study produced an extrusion panel by using cement as the base materials and substitutingbinding materials up to 40% to analyze strength characteristics. According to the results of strength characteristics bythe replacement binder (Low energy curing Admixture) showed an apparent active strength improvement. In particular,specimens substituting binder as 45% indicated the greatest strength improvement. When binding materials was used withsubstitution, it showed strength characteristics similar or higher than specimens made from tertiary autoclave curing assecondary steam curing.
        183.
        2014.04 서비스 종료(열람 제한)
        Typically low-rise dormitory designed bearing wall system. So, insulated concrete sandwich panel for the application of a rigid frame structure was changed. This study presents field application of insulated concrete sandwich panel through applying Test-Bed.
        184.
        2014.02 서비스 종료(열람 제한)
        샌드위치패널은 시공상의 용이함과 비용대비 높은 단열효과를 가지는 장점으로 공장 및 창고등 많은 분야에서 시공이 이루어지고 있다. 하지만 지난 안성 냉동창고 화재사고에서 볼 수 있는 가연성 패널이 가지는 화재확산 위험성이 상존하고 있어 대형 화재사고의 주범으로 지목되고 있으며, 소방활동을 하는 일선 소방관들에게 큰 위해 요인으로 작용하고 있다. 본 연구에서는 이러한 샌드위치패널의 화재위험성을 평가하기 위하여 가연성 패널과 글라스울 패널의 비교실험을 실시 하였다. 실험을 위하여 ISO 9705에서 제시된 구획실을 구성하였으며 내부에는 목재크립을 적재하여 화재를 모사하였다. 실험결과 가연성 패널의 경우 화재발생 후 약 2분후에 플래쉬오버가 발생하여 붕괴가 진행되었으며, 내부 최대온도는 976℃로 고온으로 측정되었다. 따라서 현재의 시편크기의 시험에서는 평가하기 어려운 구조적 안정성등 종합적인 화재 안전 평가를 위한 실규모의 화재 성능 평가법(KS F ISO 9705등)의 도입이 적극 검토되어야 할 것으로 평가된다.
        185.
        2014.02 서비스 종료(열람 제한)
        강합성 박스거더는 박스거더를 교량 주형으로 하는 강교량의 한 형식으로서, 휨 강성과 비틀림 강성이 뛰어난 강교량이다. 박스거더 설계는 강교량의 합리적 설계를 통하여, 안정성과 경제성을 추구하고 있다. 합리적 설계란 후판 및 고강도 강판을 사용하여 부재의 수를 줄이며, 설계 상세를 단순화한 교량 설계를 의미한다. 합리적 설계는 고성능강재의 사용, 부부재 최소화 등을 목표로 경제적이며 구조적으로 안전한 강합성 박스거더 설계를 한다. 이 중, 부부재의 최적설계를 위해서는 강합성 박스거더의 정확한 단면강도가 산정되어야 하지만, 도로교 설계기준(2012)에 제시되어 있는 박스거더 전단강도 산정식은 플레이트거더 전단강도과 동일한 식을 적용하도록 제시되어 있다. 이는 강합성 박스거더 복부판의 전단강도는 합성으로 인한 상부플랜지의 강성의 증가와 두 개의 복부판이 연결된 하부플랜지에 의한 복부판의 전단강도 증가를 고려하지 않고 있어 보수적인 전단강도 산정식을 제시하고 있다. 탄성전단좌굴강도에 대한 연구로는 Timoskenko와 Gere(1961)가 판의 전단좌굴강도 식을 유도하였으며, Galambos (1988)는 판의 경계조건에 따른 탄성전단좌굴계수 연구를 하였으며, Lee 등 (1996)은 플레이트 거더에서 상·하 플랜지의 영향을 고려한 탄성전단좌굴강도를 산정하는 연구를 수행하였다. 박스 거더의 연구는 합성전 박스 거더를 전단좌굴 실험을 하여, 플레이트 거더의 전단강도 보다 증가된 전단강도 실험연구가 있지만(Lee et al., 2003), 합성 후 강합성 박스거더의 복부판 전단강도에 대한 연구는 없었다.본 연구에서는 수치해석을 통하여 지지조건에 따른 강합성 박스거더 복부판의 탄성전단좌굴강도를 검토하였다. 도로교 설계 기준(2012) 및 AASHTO(2012)에 제시된 강합성 박스 거더 복부판의 전단강도산정식과 , Galambos (1988) 및 Lee 등 (1996)의 연구된 식들과 비교를 통하여 강합성 박스 거더 복부판의 전단강도를 비교-분석을 수행하였으며, 이를 통하여 강합성 박스 거더 복부판은 플랜지의 지지강성의 변화에 따라 탄성전단좌굴계수가 변화함을 알 수 있었다.
        186.
        2013.12 KCI 등재 서비스 종료(열람 제한)
        Purpose The paper tested the – relationship between the stock markets of the Middle East and the USA with the oil price and US dollar index as threshold variables. Research design, data, and methodology – The stock price indices of the USA, the Middle East (Abu Dhabi, Jordan), WTI spot crude oil price, and US dollar index were daily returns in the research period from May 21, 2001 to August 9, 2012. Following Hansen (1999), the panel threshold regression model was used. Results – With the US dollar index as the threshold variable, a negative relationship existed between the stock price indices of Jordan and the USA but no significant result was found between the stock price indices of Abu Dhabi and the USA. Conclusions – The USA is an economic power today:even if it has a closer relationship with the US stock market, the dynamic US economy can learn about subsequent developments and plan in advance. Conversely, if it has an estranged relationship with the US stock market, thinking in a different direction and different investment strategies will achieve good results
        187.
        2013.12 KCI 등재 서비스 종료(열람 제한)
        Municipal solid wastes incinerator (MSWI) bottom ash and melting slag are used to prepare external panel for increasingthe recycling rate of them in this study. In case of external panel, the most important property is flexural strength. Becauseit is easily distorted by external force. Wasted glass fiber (below WGF) is used to increase the flexural strength of externalpanel. Flexural strength of prepared panel was 14.6MPa of the mixing ratio of 3.0wt% WGF. But compressive strengthwas decreased with the addition of WGF. Because L/S ratio has to be increased to enhance the workability at high additionamount of WGF. High liquid content hinders geopolymer formation. But compressive strength (about 20MPa) was notlow at this condition.
        188.
        2013.10 서비스 종료(열람 제한)
        In this study, to Assess the impact resistant performance of steel fiber reinforced concrete(SFRC), SFRC panels with different thickness impacted by spherical object. As a result, impact resistant perfirmance is increased when the thickness and SFRC increased in
        189.
        2013.10 서비스 종료(열람 제한)
        In this study, the GFRP resisting force panel was designed through the 3dimensional analytical modeling using ABAQUS which is the commonly used finite element analyzing program. For components in the resisting force panel, the shape and resource was decided based on the destruction pattern by buckling behavior.
        190.
        2013.10 서비스 종료(열람 제한)
        The corrosion is a main cause of degradation damage in the steel bridges. The evaluation whether the repair or reconstruction would be need or not for the corroded steel member, is based on cross section and quantity of corroded portion. It is considered reasonable that the evaluation will be base on the endurance of the corroded member. In this study, the bending endurance of the I-shaped steel girder with the local corrosion on the lower flange is discussed by using elastic-plastic finite element analyses. That simple way of estimating it is also proposed.
        191.
        2013.10 서비스 종료(열람 제한)
        In this study, shear buckling behaviors of a web panel with local corrosion in a plate girder bridge were numerically examined because severe corrosion damage has been reported in plate girder bridges. The web corroded condition and boundary condition were changed to evaluate the effect of corrosion condition on the shear buckling behaviors of the web panel.
        192.
        2013.09 KCI 등재 서비스 종료(열람 제한)
        Recent climate change has led to fluctuations in agricultural production, and as a result national food supply has become an important strategic factor in economic policy. As such, in this study, panel data was collected to analyze the effects of seven meteorological elements and using the Lagrange multipliers method, the fixed-effects model for the production of five types of food crop and the seven meteorological elements were analyzed. Results showed that the key factors effecting increases in production of rice grains were average temperature, average relative humidity and average ground surface temperature, while wheat and barley were found to have positive correlations with average temperature and average humidity. The implications of this study are as follow. First, it was confirmed that the meteorological elements have profound effects on the production of food crops. Second, when compared to existing studies, the study was not limited to one food crop but encompassed all five types, and went beyond other studies that were limited to temperature and rainfall to include various meterological elements.
        193.
        2013.05 KCI 등재 서비스 종료(열람 제한)
        최근 콘크리트 구조물의 보강방법으로 FRP (Fiber Reinforced Polymer)를 이용한 외부부착보강공법이 많이 활용되고 있다. FRP 외부 부착보강은 중량에 비하여 높은 강도 및 강성, 우수한 내구성과 시공성 등 여러 가지 장점을 가지는 공법이다. 그러나 외부부착보강은 구조물이 투수성이 낮은 보강재로 밀폐되고 수분이 외부로 배출되지 못함으로 인하여, 장기적인 구조물의 손상을 발생시키는 문제점이 있다. 본 연구에서는 계면의 수분을 적절하게 배출할 수 있는 GFRP 보강재를 개발하고 투수성능을 측정하는데 주목적을 두고 있다. 이를 위하여 본 연구에서는 기존에 많이 사용되고 있는 보강공법을 투수가능한 구조로 변형하고 GFRP 함량을 변수로 보강재의 투수과정을 모사하는 실내 투수시험을 수행하여 보강재의 투수계수를 측정하였다. 또한 보강재의 투수과정에 대한 수치해석을 수행하여 측정된 투수계수 값을 이론적으로 검증하고자 하였다. 그 결과 섬유 함량중 75%의 섬유 함량에서 가장 많은 0.5129 g/h m2의 수분이 배출되었으며, 인장강도 역시 75%였을 때 최대인장강도인 4,76.6MPa를 나타내어 75% 유리섬유 함량의 COSREM GP패널이 통기성 및 구조적으로 가장 우수한 것으로 나타났다.
        194.
        2013.05 KCI 등재 서비스 종료(열람 제한)
        최근, 프리캐스트를 통한 모듈화에 대한 관심으로 인해 교량 및 빌딩 뿐만 아니라, 원전구조물, LNG 가스탱크, 중소형 강합성 구조물 등 특수구조물에도 프리캐스트 모듈화에 대한 연구가 활발하게 이뤄지고 있다. 본 연구에서는 프리캐스트 제작의 시공 및 작업성, 원활한 자재의 조달할 수 있는 방법으로 페로시멘트 (ferrocement)를 바탕으로 한 스틸메쉬로 보강된 모르타르 프리캐스트 패널을 제작하였다. 모르타르는 고강도 및 고유동성을 지니도록 실리카퓸과 고로슬래그의 배합율에 대한 변수연구를 통해 최적의 배합을 선정하였으며, 1,200×600×150mm의 패널을 제작하여 스틸메쉬로 보강한 모르타르 시편과 일반 철근콘크리트 시편을 보강비 2%와 4%로 각각 제작하였다. 제작된 스틸메쉬로 보강한 모르타르의 프리캐스트 모듈화의 적용 가능성을 판단하기 위하여 기본적인 재료물성실험과 자유건조수축실험을 수행하였으며, 선하중으로 하중을 재하하여 3점 휨 시험으로 스틸메쉬로 보강한 모르타르의 구조성능을 검토하였다. 실험결과를 통해, 스틸메쉬로 보강된 모르타르 프리캐스트 패널은 높은 휨성능 및 연성효과가 있으나, 4%로 보강된 스틸메쉬 모르타르 프리캐스트 패널은 전단보강에 대한 고려가 필요하다고 판단되며, 이에 대한 조치가 이루어진다면 프리캐스트 모듈화 부재로 적용이 가능하다고 판단된다.
        195.
        2013.04 서비스 종료(열람 제한)
        Recent advancement of domestic industries and imports and exports due to increased economic power with the rise, demands the construction of the harbor structures, and a variety of structures have been constructed of reinforced concrete. Most of these harbor facilities located in the uppe rpart of the repair and reinforcement does not work smoothly. In this paper, FRP Composite Panel shows the effect applied to the harbor facilities.
        196.
        2013.04 서비스 종료(열람 제한)
        The purpose of this study is to evaluate the flexural performance of a SHCC (Strain Hardening Cementitious Composites) panel which was manufactured by steam curing method for precast slab system. From the bending test result, it was found that the SHCC panel showed approximately 7.32 MPa of maximum flexural strength, 58 mm of mid-span deflection appearing excellent strain hardening behavior and multiple micro cracks between bending moment section of the specimen.
        197.
        2013.04 서비스 종료(열람 제한)
        Heat insulator materials can be classified inorganic and organic. The organic material is due to toxic gas emission, when a fire occurs. And it has lower water resistance. The inorganic material is heavy and worse thermal performance than organic materials. This study focused on evaluation of the physical properties of light-weight inorganic foam panel for using industrial by-products materials and performance evaluation by mock up test.
        198.
        2013.04 서비스 종료(열람 제한)
        Five specimens were planned and conducted the experimental study in order to understand flexural performance of the pre-stressing hybrid FRP panel. As the result of test, The reinforced specimen with hybrid FRP panel and the pre-stressing specimen show the structural behavior comparison with the non-reinforced specimen
        199.
        2012.11 서비스 종료(열람 제한)
        Shear panel steel damper has been widely used as seismic energy absorption device because it is economical and effective. It dissipates seismic energy by plastic deformation and fatigue resistant around welded part. However, due to early deformation of the panel under cyclic loading, the resisting strength decreases, so that the resisting capacity of the panel needs to be increased. In this paper, to investigate the improved damper called advanced shear panel damper (ASPD), both plastic deformation and resisting capacity was carried out non-linear FEA. In addition, the analysis result was compared with static loading test for verification.
        200.
        2012.11 서비스 종료(열람 제한)
        This study is to evaluate performance of two-way acting insulated sandwich wall panels through flexural experiment. The two-way acting panel resists wind loading on the panel and on the window. In this study, GFRP(Glass Fiber-Reinforced Polymer) Grid-type shear connectors are used for the composite action of the sandwich wall panels. Layouts of shear connector are considered as main parameter of this experimental study.