        2009.09 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        In order to improve indoor air quality of apartment, indoor ventilation system had to be installed in each unit, from 2006 in Korea. However, a duct which is connecting each room in ventilation system became a flanking path of sound. Sound which is generated in one room can easily transmitted into the adjacent room by the duct and speech privacy in apartment room can be seriously degraded. In this study, low noise duct system consisted of noise diffuser and multi drop chamber was developed and noise reduction performance was measured in mock-up system. Noise reduction performance of low noise duct system was compared with conventional duct system. From the result of measurement, it was found that noise diffuser reduce more than 10 dB in the range of 200 Hz and higher frequency band, also multi drop chamber was effective in 2000 HZ and higher frequency band. Noise reduction performance of low noise duct system is effective in the frequency range (from 300 Hz to 4000 Hz bands) of speech conversation.
        4,000원
        62.
        2009.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        In this paper, it is intended to investigate the condensation characteristics of a supply vent cap, which is designed and developed for natural ventilation systems for ondol heating spaces. Numerical simulations are conducted using a CFD package to analyze airflow and thermal conditions around the vent cap. Temperature and humidity distributions are obtained to predict condensation on the surface, depending on the material properties. As the thermal conductivity decreases, decreased is the condensation surface area. The thermal conductivity of the vent cap is found to be less than 1 W/mK in order to prevent condensation under the winter design condition of Seoul. An experimental technique is introduced to visualize condensation on surfaces using water-absorbing mud film. Analytical results are in good agreement with experimental observations. Discussion are also included for the thermal comfort and flow characteristics around the vent cap observed by the flow visualization and temperature visualization studies.
        4,000원
        66.
        2007.03 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        지하 동굴식 처분장의 건설, 운영 및 중-저준위 방사성폐기물을 처분한 이후 발생하게 되는 오염물질(Rn, CH CO, HS, Radiolysis에 의한 방사능 가스 등)은 적절한 공기량을 필요로 한 곳에 정확히 분배시킬 수 있는 환기시스템에 의해 통제되도록 하여야한다. 특히 지하 처분장은 여러 개의 진입 터널, 저장 터널, 공기 유입-배기 터널, 수직갱 등으로 이루어진 복잡한 회로망의 형태로 나타나기 때문에 이에 적절한 기술적 접근이 필요하다. 본 논문에서는 이러한 환기시스템 구축을 위한 기술적 접근을 위해 미국의 WIPP (Waste Isolation Pilot Plant)처분장과 스웨덴의 SFR (Slutforvar for Reaktoravfall) 중-저준위 처분장을 모델로 하여 두 처분장의 소요환기량을 선정하고 설계상 통풍로의 단면적, 길이, 표면 거칠기 등을 고려한 환기회로를 구성하였으며, 수학적으로 계산되는 각 회로의 저항에 대해 기술하였다. 또한 이를 바탕으로 적절한 선풍기의 용량과 수직갱 운용방안을 설계하였다. 두 처분장의 지형상의 규모 및 환기시설 비교 결과, SFR 처분장에 비해 WIPP 처분장에서와 같이 병렬구조가 많을수록 처분장 전체의 저항이 감소되며 이러한 결과로 환기시스템의 운용비 절감효과를 얻을 수 있다는 결론을 얻었다. 따라서 처분용량 증대를 위한 대단면의 SFR 처분장 구조와 전체 저항 감소를 위한 WIPP 처분장의 병렬구조를 조합한 형태가 가장 합리적이며 효율적인 환기가 이루어질 수 있을 것으로 사료된다.
        4,600원
        67.
        2006.09 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Vehicle drivers are subject to be exposed to high concentrations of airborne pollutants emitted from vehicles on roads. To investigate the indoor air quality of vehicles on roads, black carbon (BC) was measured inside a passenger car commuting between the residential area in southern Seoul and the Korea Institute of Science and Technology (KIST) in northern Seoul using a portable aethalometer. When the vehicular windows were closed, the ventilation mode was set to fresh air mode (or circulation mode) for a total of thirteen runs made during May 2005. When the windows were open, the analysis was made with the system turned off (for twelve runs in October 2005). The BC concentration depended on such parameters as spatial location, time of day, and ventilation mode. The average BC concentration measured on non-express ways was higher than those measured on express ways, inside KIST, and nearby the residential area for most runs. On circulation mode, the average BC concentration was 5.9±1.7 ㎍/㎥ in the afternoon or evening, which was similar to a 24-hr average BC concentration for ambient air at 200 m apart from a road in Seoul. In the case of fresh air mode, the average BC concentrations measured in the morning rush hour, in the afternoon or evening, and after midnight were 22.8±3.4, 15.9±7.7, 3.7 ㎍/㎥, respectively. The average BC concentrations measured with the vehicular window open were 31.9±9.2, 19.4±5.9 ㎍/㎥, respectively in the morning rush hour and in the afternoon or evening. These measured values were higher than those measured with the windows closed. The average BC concentrations inside a passenger car with a fresh mode operation or open-window driving were significantly higher than a 24-hr average BC concentration measured at 200 m apart from a road in Seoul.
        4,500원
        69.
        2006.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Culex pipiens complex larvae were found at the septic tanks in Susan and Ulsan cities located in South-eastern area of Korean peninsula. The larvae were collected in 25, 35 and 75 septic tanks out of 3,527, 622 and 1,111 septic tanks which the breeding rates were averages of 0.7%, 5.6% and 6.8% in Susan from January to May, 2003, Susan from February to March, 2004, and Ulsan from January to April, 2005, respectively. The average numbers of the mosquitoes in the tanks were 38.8, 14.9 and 13.7 larvae/dip with a 355-㎖ dipper. The larval densities were from 25.4 larvae/dip in January to 43.7 larvae/dip in April. 2003 which were not significantly different between them. It was the first report to find mosquito breeding at septic tanks in Republic of Korea. Culex pipiens larvae were found in 6 out of 379 septic tanks at complex buildings (over 2,000㎡ in size) in Ulsan from June to September, 2005, having an average of 1.6% for mosquito breeding rate. The mosquito larvae were collected in 8 and 530 septic tanks out of 210 and 3,729 septic tanks at large (over 300 homes) and small apartments (below 300 homes) with 3.8% and 14.2% of the average breeding rates, respectively. At the septic tanks of private houses for below 50 persons, 708 out of 7,178 septic tanks had Cx. pipiens larvae and pupae with 9.9% of the average breeding rate. Total average of the mosquito breeding rate was 10.9% of the investigated septic tanks of residential buildings in Ulsan. The number of mosquito larvae in the septic tanks were 15 to 75 larvae/dip. The bent net sets of septic tanks prevented from mosquito breeding to the rate of 93.1 %.
        4,000원
        70.
        2005.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        자주초롱꽃(Campanula punctata 'Rubriflora')의 자가영양배양시 CO2 농도,환기횟수 및 광도가 소식물체의 생장에 미치는 영향을 조사하였다. 1,500μmol·m-1고농도CO2에서는 광도를 높일수록 초장, 엽수가 증가되었으나, 최대근장은 유의성이 인정되지 않았다 엽록소의 함량은 광도가 높을 때보다는 낮은 경우인 70μmol·m-2s-1에서 가장 많이 증가되었다 엽면적은 광도가 높을수록 작아지는 경향을 보였으며, CO2 1,500μmol·mol-1 환기횟수 2.8h-l, PPF 220μmol·m-2·s-1에서 가장 큰 차이로 작게 나타났다. 생체중과 건물중은 CO2 농도, 환기횟수, PPF가 높을수록 증가되었다. 특히 CO2 1,500μmol·mol-1, 환기횟수 2.8h-1, PPF 220μmol·m-2·s-1에서 가장 크게 증가되었다. 환기횟수의 영향은 전반적으로 적었다. 종합적으로 자주초롱꽃 소식물체의 기내 자가영양배양 차량번식을 위해서는 CO2 1,500μmol·mol-1, PPF 220μmol·m-2·s-1의 조건이 적합하였다.
        4,000원
        71.
        2005.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        자연환기는 처분장의 작업 환경 및 위생, 부유 방사성 핵종의 노출 등과 같은 안전문제에 있어 자연환기 자체만으로는 기계적 강제 환기에 비해서 덜 효과적이지만 처분장 내의 수분제거, 작업 환경 조성과 관련하여 라돈 (Rn) 가스의 희석과 같은 향후 처분장의 장기적 환경을 위해서는 중요한 역할을 할 수 있고, 환풍기와 같은 환기 설비를 이용해야하는 기계환기에 비해 경제적으로 매우 효과적 일수 있다. 본 논문에서는 지하 처분장의 건설 및 운영 기간동안 자연환경 조건에 따라 처분장에 스스로 생기는 자연 환기의 타당성에 대하여 기술하였다. 자연 동굴을 통한 자연환기 유사에 의해 밝혀진 증거들과, 수직갱을 갖는 산악 도로터널에서의 자연 환기 측정, 그리고 주어진 자연환기 압력에 의한 공기 발생량 계산 등을 통해서 자연 환기는 한국형 지하 방사성 폐기물 처분장에 잠재적으로 매우 유익함을 알 수 있다. 효과적으로 유도된 자연 환기는 방사성 폐기물 처분장 내에 발생하는 열과 습도, 그리고 라돈 가스를 제어하기에 경제적으로 좋은 방법이 될 수 있다. 자연환기를 통해 처분장의 전반적 열적 특성은 개선될 수 있고, 수분으로 포화된 공기는 효과적으로 건조되고 그 건조상태 유지 기간은 확장 될 수 있을 것이다.
        4,000원
        73.
        2005.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        A ventilation system comprising a dielectric barrier discharger and UV‐TiO2 photocatalyst filters was designed and tested for simultaneous removal of gaseous and particulate contaminants in a test chamber. The DBD was used as the 1st stage of ESP for particle charging and gas decomposition. Charged particles were collected in the 2nd stage of ESP by an applied DC electric field. The UV‐TiO2 photocatalyst filters were used for decomposing gaseous species including O3 which was inherently produced by the DBD. Particle removal efficiencies based on mass and number were approximately 83.0% and 88.8%, respectively, after the ventilation system was operating for 5 hours. HCHO removal efficiency was approximately 100% for 1∼5ppm of upstream concentration condition. TVOC removal efficiency was 99.0% and 99.6% for 1 ppm and 5 ppm of upstream concentration conditions, respectively.
        4,200원
        74.
        2005.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        We performed numerical analyses on the optimal discharge angle of a 4-way cassette air conditioner, which is mounted on the ceiling of the classroom, by using thermal comfort and ventilation indices. We analyzed the effective draft temperature, the local mean age and the local mean residual life time with respect to the variation of the air discharge angle of the air conditioner in all occupied zone. Air diffusion performance index, local supply effectiveness and local exhaust effectiveness were used to investigate the optimal value of air discharge angle. From the results, we found out that the optimal discharge angle of the air conditioner is about 40 degrees in the present model.
        4,000원
        75.
        2005.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        방사성 폐기물의 지층 처분장 건설 및 운영을 위한 개념 선정 단계에서는 폐기물 운반 및 거치뿐 아니라, 처분장의 건설/운영/폐쇄 기간 동안 지하 처분장의 작업 환경 및 위생, 안전, 그리고 처분장내의 수분 제거와 같은 향후 처분장의 환경을 위해 처분장 환기시스템에 대한 고려가 향후 처분장의 환경을 위해 반드시 필요하다. 본 논문은 동굴처분 방식의 중-저준위 처분장 및 지하 심부에 위치하게 될 고준위 처분장에 대한 환기시스템 개념설계 기준 및 요구사항에 대한 내용이다. 방사성폐기물 처분장의 환기 시스템에서 가장 주된 기본 설계 개념은 처분장 건설과 폐기물저장을 위한 작업활동을 위해 각각 독립적이고 분리된 환기시스템을 적용하여야 한다는 것이다. 본 논문에서는 방사성폐기물 처분장의 환기시스템의 설계과정에 대해 기술하고 환기회로 모델링 방법, 자연 환기, 환기 모니터링 시스템과 실시간 환기 시뮬레이션, 화재 시뮬레이션 및 비상 방재 시스템에 관한 사항도 논의하였다
        4,600원
        76.
        2004.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This paper describes to evaluate the performance of ventilation as a change of CO2 concentration with ventilation rate under 35 occupants in a school classroom. Variations of the CO2 concentration as a function of time are measured at center point of classroom with air ventilation rates by the CO2 gas monitor. For 800 m3/h of ventilation rate in the classroom, the average CO2 concentration is 913 ppm. The ventilation rate is sufficient to meet acceptable indoor air quality (≤ 1,000 ppm of CO2, KS school standard) in the classroom of 35 students.
        4,000원
        77.
        2004.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 도시기후를 고려한 도시계획이 많은 나라에서 실용화되고 있다. 도시기후의 고려는 주로 도시의 바람 길 조성이라는 개념으로 구체화되고 있다. 도시의 바람 길 조성은 주로 하계에 도시지역의 열적 쾌적성을 개선하는 것을 목표로 한다. 아울러, 과학적 조사에 근거하여 도시의 단지계획을 합리적으로 함으로써 청정한 냉기류의 도심유입을 원활히 하여 도심의 대기오염을 저감하고자 하는 것도 목적으로 한다. 이 연구에서는, 수치실험을 통하여 전형적인 난후기일을 대상으로 대구지역의 국지순환풍이 지나는 바람의 길을 조사하였다. 그리고 이 바람에 의한 대기오염의 수송도 조사하였다. 수치실험에 사용한 모형은 RAMS(지역규모 대기모델)이다. 수치실험의 관심지역은 대구광역시 일대(약900km2)이다. 수평규모는 약 30km이다. 수치실험은 일반풍이 약하고 쾌청한 일기조건을 갖는 늦봄의 기상조건 하에서 수행되었다. 수치실험의 결과 다음과 같은 3가지 결과를 얻었다: (1) 대구의 대표적 산지인 팔공산과 앞산에서 야간에 산정에서 복사냉각으로 생성된 국지풍이 지나는 길을 발견할 수 있었다. 그 바람은 대구의 동쪽 지역에서 중력류의 형태로 계곡을 따라서 흘러내렸다. (2) 평지에서는, 그 바람이 대구의 중심지를 지나 서쪽으로 흘러갔다. (3) 그 결과로, 대기오염물질은 야간에 국지풍에 의해 서쪽지역으로 수송되어졌다.
        4,000원
        80.
        2003.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 양봉사 내부환경을 보다 효율적으로 조절할 수 있는 환기팬 작동방식을 구명하기 위하여 시뮬레이션을 통해 얻어진 환기팬 작동방식에 대한 연 구결과를 양봉사에 직접 적용하여 실험을 실시하였으며, 양봉사 내부의 온도 및 습도변화에 대한 시율레이션과 실험결과를 비교 · 분석하여 양봉사 설계시 양봉사 열환경 해석 프로그램의 적용성을 검토하고, 실험결과를 이용하여 환기팬 작동방식별 양봉사 내부환경의 조절 성능을 분석하였다. 기 개발된 양봉사 열환경 해석 프로그램은 앞으로 양봉사 설계에 적절하게 이용할 수 있을 것으로 판단되었다. 외부기온이 비슷한 조건에서는 환기팬 작동방식 B의 경우가 A의 경우보다 양봉사의 내부온도가 대체로 더 낮았으며, 평균적으로 벌통 내부는 2.8℃, 양봉사 내부는 2.1℃ 더 낮았다. 이것은 Lee 등(1998b)이 제시한 환기팬 작동방식에 따라 양봉사 내부의 승온억제를 최고 2.8℃까지 할 수 있다는 내용을 뒷받침하는 실험결과이다. 환기팬 작동방식 A와 B 모두 꿀벌이 월동하기에 적합한 상대습도 범위 (50~75%) 였으나, 방식 B가 A 보다 양봉사 내부 습도의 최고 및 최저편차가 약 2%, 평균습도가 약 5% 적게 나타나 습도환경조절에 있어 좀 더 안정적인 것으로 판단되었다. 따라서 환기팬 작동방식 B는 A 에 비하여 양봉사 내부환경조절 성능이 더욱 우수하고 효율적인 것으로 판단되었다.