In this paper, we examined how large beams were developed in Korea, China, and Japan in the 6th and 8th centuries, and how this pattern affected Korean architecture later. A large inner space was required to symbolize the authority of the emperor and king and to achieve the purpose of enshrinement of a large Buddha statue forming a cluster, and a large beam over 9m was used to implement this. The use of large beams is confirmed from the late 4th century in China and from the late 5th century at the Seoyeongchonsa Temple Site in Nanjing. In Korea, it is identified from the Lecture hall of Neungsan Risa Temple Site in Baekje(567) and from the middle Buddhist shrine Temple in Hwangnyongsa Temple in Silla(584). Goguryeo is presumed to be around the 6th century, a little earlier than that. In Japan, large beams were used for the first time at the the Lecture hall of Bijosa Temple in 588, which was built by a Baekje engineer. From ancient times to the modern era, the inner space length of the Korean, Chinese, and Japanese architecture was exceptional in some cases, but 9-12m was common. This is judged to be the result of the experience of the material limitation of wood and the size of the inner space established in ancient architecture affecting future generations as a precedent.
Automated structural design methods for reinforced concrete (RC) beam members have been widely studied with various techniques to date. Recently, artificial intelligence has been actively applied to various engineering fields. In this study, machine learning (ML) is adopted to make automated structural design model for RC beam members. Among various machine learning methods, a supervised learning was selected. When a supervised learning is applied to development of ML-based prediction model, datasets for training and test are required. Therefore, the datasets for rectangular and t-shaped RC beams was constructed by commercial structural design software of MIDAS. Five supervised learning algorithms, such as Decision Tree (DT), Random Forest (RF), K-Nearest Neighbor (KNN), Artificial Neural Networks (ANN), eXtreme Gradient Boosting (XGBoost) were used to develop the automated structural design model. Design moment (Mu), design shear force (Vu), beam length, uniform load (wu) were used for inputs of structural design model. Width and height of the designed section, diameter of top and bottom bars, number of top and bottom bars, diameter of stirrup bar were selected for outputs of structural design model. Performance evaluation of the developed structural design models was conducted using metrics sush as root mean square error (RMSE), mean square error (MSE), mean absolute error (MAE), and coefficient of determination (R2). This study presented that random forest provides the best structural design results for both rectangular and t-shaped RC beams.
This study investigated benthic macroinvertebrates and fish in the Yeongsangang River weir and analyzed stomach contents of Squalidus chankaensis tsuchigae. Length distribution of individuals varied by site, with 91.3% and 72.7% falling within the 70-90 mm range in SC-U (upstream location of Seungchon weir) and SJ (location between Seungchon and Juksan weirs), respectively, and 77.5% within 70-80 mm and 100 mm range in JS-D (downstream location of Juksan weir). Chironomidae spp. (nonred type) were the most abundant food sources, comprising 46.3%, 76.9%, and 88.3% of the diet at SC-U, SJ, and JS-D, respectively. The Electivity Index (EI) indicated a strong preference for Chironomidae spp. (non-red type) (0.927) and avoidance for the red type (-0.929) and Limnodrilus gotoi (-0.995). The proportion of burrowers (BU) increased downstream, while swimmers (SW) decreased. The condition factor (K) varied by site, decreasing in SC-U and increasing in SJ and JS-D, showing a significant positive influence on the number of food sources (p<0.05). Among food sources, Chironomidae spp. and Baetidae sp. were predicted to be utilized across a broad range of lengths and weights, with strong connectivity observed among Tanypodinae sp., Hymenoptera sp., and Baetiella tuberculata.
This study aims to analyze the natural frequency characteristics of multi-cracked extensible beams. The model and governing equations of the multi-cracked beam were derived using Hamilton's principle while considering crack energy. The eigenmode functions were obtained through eigenvalue analysis by applying the patching conditions of the cracks, and the equations for the discretized cracked beam were formulated and solved. The displacement responses from nonlinear system analysis were used to calculate frequencies via Fast Fourier Transform (FFT), and the frequency characteristics were systematically analyzed with respect to the number of cracks, crack depth, and cross-sectional loss. Additionally, the natural frequencies and orthonormal bases of the linear system were derived by exploring the solutions of the characteristic equation reflecting the cracks. Numerical analyses showed that the natural frequency of a cracked extensible beam was higher than that of a cracked EB beam. However, as the number or depth of cracks increased, the natural frequency gradually decreased. Notably, in extensible beams with large deflections, the dynamic changes caused by cracks demonstrated results that could not be obtained through the EB beam model.
The purpose of this study is to experimentally analyze the seismic performance of a vertical irregular beam-column specimen reinforced with RBS (Replaceable Steel Brace System), a steel brace system. To evaluate the seismic performance of RBS, three specimens were manufactured and subjected to cycle loading tests. The stiffness ratio of beam-upper column of the non-retrofitted specimen was 1.2, and those of the two retrofitted specimens were 1.2 and 0.84. The stiffness ratio of the beam-lower column of all specimens was 0.36. And the stiffness ratio were used for variable. As a result of the experiment, the specimen retrofitted with RBS showed improved maximum load, effective stiffness and energy dissipation capacity compared to the non-retrofitted specimen with the same beam-upper column stiffness ratio. The specimen with 0.84 beam-upper column stiffness ratio showed improved performance compared to the specimen with 1.2 stiffness ratio.
This study proposes an economically affordable method for retrofitting non-seismic detailed roof reinforced concrete beam-column joints (BCJs). The proposed method presents an innovative arrangement of steel plates designed to delay the propagation of joint shear cracks by externally applying compressive stress to the area surrounding the BCJs. Two full-scale sub-assemblage specimens for each exterior and interior roof BCJ, i.e., control and retrofitted specimens, were subjected to reversed cyclic loading to evaluate the proposed method. The retrofitted specimens displayed a preferable ductile behavior to the corresponding control specimen, with an enhancement in lateral strength by at least 100%. Furthermore, retrofitted specimens dissipated up to 13 times more energy than the control specimen by initiating a plastic hinge on beams or columns. These results indicated the effectiveness of the proposed method in preventing joint shear failure and improving the seismic behavior of roof BCJs.
PURPOSES : This study was conducted to prevent slip accidents on manhole covers located on sidewalks and local roads as well as to propose reasonable slip resistance management standards for manhole covers. METHODS : Using field surveys, test groups were classified based on the patterns and wear amounts of the manhole covers. Standards for measuring the equipment and methods for slip resistance were established, and the slip resistance values were compared and analyzed for each manhole cover test group. RESULTS : According to the slip resistance test results, micro-protrusions on the non-slip manhole covers were found to be effective in improving slip resistance. However, in areas without microprotrusions, the improvement in slip resistance was minimal and yielded results similar to those of standard manhole covers. In addition, among the pattern types of standard manhole covers, the radial pattern was found to be the most susceptible to slipping. Under the current wear measurement standards, the change in slip resistance at different wear stages was found to be relatively small. Moreover, manhole covers had the lowest slip resistance among road surface structures, indicating the need to establish management standards for them. CONCLUSIONS : To prevent pedestrian slip accidents on sidewalks and local roads, it is necessary to ensure that the slip resistance standards of manhole covers are higher than those of sidewalks.
최근 전 세계적으로 탄소 배출을 줄이기 위한 노력이 계속되고 있다. 이에 따라 건설 부문에서도 시공 과정에서 탄소 배출 을 줄일 수 있는 방안을 모색하고 있다. 그중 하나가 RC 건물에서 철근을 CFRP 보강근으로 대체하는 것이다. KDS 기준에 따라 설계 된 7개 건물의 설계 자료를 바탕으로 구조부재의 철근 비율을 비교하여 철근을 CFRP 철근으로 대체할 가능성을 분석했다. 그 결과, 건물의 구조부재 중에서 슬래브가 CFRP 철근의 대체 효과가 가장 큰 것으로 나타났다. 일반적인 건물 슬래브의 경간이 1.25∼4.1 m인 것을 감안할 때 RC 슬래브에서 CFRP 철근을 철근으로 대체할 경우 CFRP 철근의 양을 철근의 1/2∼1/3까지 줄일 수 있었다.
국내에서는 고속도로에는 콘크리트 포장을 적용하고 있지만 도심지에서는 콘크리트의 양생기간으로 인해 장기간 교통차단이 필요없 는 아스팔트 포장을 주로 적용하고 있다. 그러나 아스팔트 포장은 공용수명이 길지 않아 잦은 유지보수 작업으로 인해 사용자들의 불 편을 초래하고 있다. 본 연구에서는 현장타설 콘크리트 포장 공법을 적용하더라도 즉시 통행이 가능한 포장 임시보호판 개발을 위하 여 임시보호판의 하부 지지보 설치 간격 최적화를 목적으로 3차원 유한요소해석 프로그램을 이용하여 차륜 하중에 대한 응력분포를 분석하였다. 해석에 사용된 임시보호판은 길이 6m, 폭 3m, 두께 0.3m의 콘크리트 슬래브로 구성하였으며, 임시보호판의 하부 지지보 간격을 0.5m, 1m, 1.5m, 3m, 6m로 구성하였다. 하중 조건은 중차량인 버스를 고려하여 타이어 접지 면적당 33,540N의 분포하중을 지지 보 사이에 적용하여 분석하였다. 해석 결과, 하부 지지보 사이의 간격이 좁아질수록 응력이 감소하는 것을 확인하였다.
본 논문은 염해 환경에 노출된 CFRP Grid로 보강된 콘크리트 보의 휨 거동에 대한 실험적 연구를 보고한다. 실험을 위해 길 이 2,200 mm, 폭 250 mm, 높이 125 mm의 실험체가 제작되었다. 실험변수로 염화물 수용액의 종류(NaCl: 염화나트륨, CaCl2: 염화칼 슘), 사전 하중 가력의 유무 및 염화물 용액 침지 기간(40일, 120일)이 고려되었다. 제작된 실험체는 침지 후 3점 휨 실험이 수행되었다. 초기 균열 하중은 침지 40일 후 증가하였으나, 120일 이후 다시 감소하였다. 파괴 모드는 사전 하중 가력을 통해 균열이 발생되지 않은 실험체에서는 대부분 콘크리트 압축부가 파쇄되는 휨파괴 양상을 보였으며, 사전 하중 가력을 통해 균열이 발생된 실험체는 모두 Pull-Out 파괴가 발생되었다. 염화칼슘에 침지된 실험체에서는 120일 이후 약 10%의 극한하중의 감소가 나타났으며, 염화나트륨에 침지 된 실험체의 극한하중은 미미하게 증가하였다. 균열이 발생된 실험체에서는 모두 120일 이후 극한하중 및 처짐이 급격하게 감소되었다.
철근은 콘크리트와 결합하여 인장 능력을 보완하고 표면 피막으로 부식을 방지하지만, 탄산화 및 염화물 침투로 인해 부식이 발생하면 내력이 저하된다. 이를 해결하기 위해 내부식성이 뛰어난 GFRP(Glass Fiber Reinforced Polymer) 보강근이 철근 대채제로 주 목받고 있다. 본 연구는 직경에 따른 GFRP 보강근의 부착특성을 철근과 실험적으로 비교 분석하였다. 콘크리트는 약 39MPa의 고강도 에 가까운 콘크리트를 사용하였으며, 보강근의 직경은 D10과 D13을 사용하였다. 실험 결과, GFRP 보강근의 평균 부착 응력은 17.21MPa로 철근의 18.14MPa와 유사하게 나타났다. GFRP 보강근의 슬립 양은 3.05mm로 철근의 1.53mm 보다 크게 나타났다. 또한 GFRP의 경우 인발 과정에서 표면에 국부손상이 발생하는 것을 확인하였다.
본 연구에서는 철근의 부식 문제를 근본적으로 해결하기 위하여 고속도로 교각 두부보에 GFRP 보강근을 적용하고 구조설계 및 3차원 유한요소해석을 수행하였다. AASHTO LRFD 설계기준에 근거하여 교란영역(D-region)인 두부보를 설계하였으며, 기존 연구결 과를 바탕으로 설계기준보다 완화된 계수를 적용하여 결과를 비교하였다. 또한, 두 가지 설계에 대해 각각 3차원 유한요소해석을 수행 하여 설계 결과를 검증하였다. 본 연구의 결과로부터 완화된 계수 적용을 통해 GFRP 보강 교각 두부보의 경제성 확보가 가능하다는 결과를 얻었으며, 이는 다양한 GFRP 보강 콘크리트 구조물의 실용화에 기여할 수 있을 것이라 기대된다.
이 연구는 의사소통 중심 교수법을 바탕으로 학습자 중심⋅주도형으로 이루어진 A 보건 대학교 간호학부 교과목 ‘고전과 인성’ 수업 운영 사례 를 1차 사전 설문조사, 수업 운영 방법, 수업 활동 분석, 2차 사후 강의 만족도 설문조사 결과 분석 후 개선점을 제시함으로써 대학 고전 교육의 방향을 모색한 데 의의가 있다. 먼저 전체 수업에 대한 만족도 조사 결 과, 조별 수업 주제 요약 및 관련 도서 읽은 후 요약, 간호 업무에 적용 하기, 소감 말하기, 발표와 토론, 나의 생각 쓰기로 구성된 수업에 전체 학습자(120명) 중 83%(매우 만족 38%, 만족 45%)가 ‘만족하는 것’으로 나타났다. 게다가 ‘고전과 인성’ 교과목 수업계획서에 명시한 학습 목표 5가지가 달성되었고, 92% 학습자가 후배 학습자들에게 이 교과목을 추 천하겠다고 하였으므로 유의미하다. 그러나 교육부는 ‘국어과 교육과정 (읽기, 쓰기, 듣기⋅말하기)을 관리⋅감독 강화 및 개편해야 한다. 왜냐하 면 ’고전과 인성‘ 수업 운영 사례 결과, 이것을 학습자들이 어려워했거나 제대로 수행하지 못하였기 때문이다.
본 연구는 보강 콘크리트로 철근 대신 복합재료를 사용한 구조물의 설계에 대하여 다양한 파라미터 연구를 수행하여 철근콘크리트 대비 강점을 비교, 분석하였다. FRP 콘크리트는 ACI 440.1R-15를 적 용하였으며, 철근콘크리트 설계는 KDS 14(2021)의 최신 규정을 적용하여 다양한 파라미터 연구를 수 행하였다. 파라미터 변수로 콘크리트 밑단에서 철근의 중심까지의 거리, 보강량, FRP의 탄성계수 및 극한 변형률의 4개로 설정하여 다음과 같은 결론을 얻었다. (1) FRP의 탄성계수와 극한 변형률이 클 수록 FRP 콘크리트의 휨성능이 우수하지만, 극한 응력이 동일할 때 극한 변형률보다 탄성계수를 크게 하는 것이 유리하며, 보강량이 작을수록 유리한 것으로 분석되었다. (2) FRP 콘크리트가 인장지배 단 면이나 변화구간 일 때 극한 변형률 증가에 휨성능이 비례해서 증가하지만 압축지배 단면일 경우에는 극한 변형률이 증가해도 휨성능은 증가하지 않는다. (3) FRP 콘크리트의 휨성능은 FRP의 탄성계수와 극한 변형률을 적절하게 조절하여 선택함으로서 최적의 성능을 나타낼 수 있다. (4) 또한, FRP 콘크리 트는 최소 피복두께가 필요하지 않아 추가적인 휨성능이 17~33% 증진 효과가 나타났다.
건축물은 사용자의 부주의, 전기적, 기계적 요인 등에 의해 화재가 발생할 수 있고, 화재 발생 시 각 재료의 특성에 따라 강성 및 강도가 감소하여 구조 성능이 저하될 수 있다. 이러한 상황에서 적절 한 성능 복구가 되지 않으면 후에 지진 등의 큰 하중이 가해질 때 건축물 붕괴 등 치명적인 피해가 발생할 수 있다. 현재 내화성능을 높이는 방법으로 내화피복을 사용하는 등 수동적인 방법에 머물러 있으며, 꾸준한 유지관리 등이 필요하다는 단점이 있다. 따라서 변형 후 열을 가하면 원래의 형상으로 돌아가는 성질을 가진 형상기억합금을 사용하여 콘크리트 보를 보강하고, 화재 시, 화재 후에 프리스 트레스트 콘크리트와 유사한 방식으로 콘크리트에 압축응력을 발생시켜 구조 성능을 향상시킬 수 있 는지 ANSYS 구조해석 프로그램을 통해 그 효과를 확인해보고자 한다.
국내 건축물에서는 노후한 철근콘크리트 구조물의 안전성이 중요한 문제로 대두되고 있다. 구조물 부분이나 전체의 무너짐으로 인해 경제적 손실을 초래할 수 있으며, 이는 주로 구성 재료의 내구성 결 함으로 인해 발생한다. 여러 노후화 인자 중 동결융해와 부식은 주요한 열화 요인으로 작용한다. 동결 지역의 구조물은 동결융해가 위험 요소로 작용할 수 있으며, 해양 구조물은 해수에 존재하는 염소이온 에 의해 부식될 수 있다. 이러한 문제를 해결하기 위해서는 복합 열화 작용과 철근콘크리트 부재의 성 능 저하 관계를 이해하는 것이 필요하다. 본 연구는 동결융해와 부식의 복합적 피해가 RC 보의 거동 에 미치는 영향을 실험적으로 조사하였다. 7개의 RC 보를 제작하여 각각 다른 수준의 열화 조건을 부여한 후 휨 시험을 실시하였다.
우리는 콘크리트 세상 속에 살고 있다고 해도 과언이 아니다. 콘크리트 도로를 달리고 콘크리트 건 물 속에서 살고 있다. 그런데 최근 노후화된 구조물의 붕괴 사례들이 지속적으로 발생하고 있으며 이 에 대한 원인 규명과 재발 방지, 그리고 기술적 사전 예측 등이 필요하다. 특히 우리나라의 경우 4계 절의 영향을 받는 철근콘크리트 구조물은 시간이 흐름에 따라 다양한 열화로 인해 강도가 저하되고, 이로 인해 건축물의 심각한 손상 및 붕괴가 발생하게 된다. 전국적으로 기온이 영하로 내려가는 겨울 철에는 동결융해의 영향으로 인한 강도 저하로 노후화가 진행되며, 콘크리트의 공기율에 따라 동결융 해로 인한 노후화 정도가 달라지게 된다. 이는 콘크리트 공기율에 따라 내구성지수가 변화하여 동결융 해의 영향 정도가 변화하기 때문이다. 그러나 기존의 콘크리트에 관한 동결융해 영향 연구는 재료에 대한 연구가 많지만, 상대적으로 큰 철근콘크리트 부재 단위에 대한 연구는 부족하다. 따라서 본 연구 에서는 철근콘크리트 부재를 대상으로 기중 동결융해 시험 방법을 통해 콘크리트의 공기율이 증가함 에 따른 재료 단위의 영향과 철근콘크리트 부재의 휨 거동 특성에 대한 영향을 분석하고자 한다.본 연 구에서는 동결융해를 입은 콘크리트가 공기율이 증가함에 따라 동탄성계수와 내구성지수를 비교하고, 이에 따른 압축강도 실험을 통해 동결융해의 영향을 평가하였으며 철근콘크리트 부재의 휨 실험을 통 해 동결융해가 콘크리트 공기율에 대하여 거동 특성, 탄성 강성 및 항복까지의 에너지 흡수 능력에 미 치는 영향을 비교하여 분석하였다. 또한 ABAQUS 해석 프로그램을 사용하여 유한요소 모델을 제안하 고 휨 거동 성능을 실험값과 비교하여 분석하였다.