일반차량과 자율주행차량이 혼재하는 상황에서 발생가능한 미래 재난상황에 대한 관리방안 준비가 필요하다. 특히 재난 상황 중 안 개 발생 시 시야 확보가 어려운 일반차량 운전자와 센서기반 자율주행차량의 주행 특성이 다를 수 있다. 해당 상황에서의 문제점을 도출하고 이를 극복하기 위해 혼합교통류 관리 방안을 제안하고자 한다. 본 연구에서는 다양한 재난 상황 중 안개를 연구 대상으로 설정하였다. 과거 기상 상황별 일반차량을 주행 특성을 이력자료로 분석한 후, 안전한 교통흐름을 유지하기 위하여 자율주행차에게 정 보를 제공하는 방안을 제안한다.
PURPOSES : This study proposes brief guidelines for traffic engineers in the field to refer to when operating tram priority signals based on the "early green" and "green extension" methods.
METHODS : A set of VISSIM simulation analyses was conducted considering various traffic and control conditions in a hypothetical corridor consisting of two signalized intersections. The traffic conditions were varied at five different levels. The control conditions were varied at twenty-five levels by changing the tram priority traffic signal control parameters, i.e., the early green unit time and green extension unit time. A total of 125 simulation runs were from these combinations. A set of optimal signal timings for ordinary non-tram vehicles was prepared with TRANSYT-7F and implemented for the simulation. A tram priority signal control module based on VISVAP was exclusively developed for this study.
RESULTS : As expected, no specific trend was found in the relationship between the two tram priority control parameters (early green time and green extension time). However, a trend was observed when assuming that the early green and green extension operations were mutually exclusive. Specifically, an inverse trend appeared between the tram priority control parameter values and level of congestion according to the performance measure (average network delay).
CONCLUSIONS : For the early green control parameters, it is better to provide six seconds when undersaturated and four seconds when near-saturated. For the green extension control parameter, four seconds is suitable.
메타바나듐산 암모늄으로 제조한 전해액과 양이온교환막인 Nafion117을 활용하는 바나듐 레독스 흐름 전지 (vanadium redox flow battery, VRFB)의 전기화학적 성능을 평가하였다. VRFB의 전기화학적 성능은 전류밀도 60 mA/cm2에 서 측정하였다. 메타바나듐산 암모늄으로 제조된 전해액을 사용한 VRFB의 평균 전류효율은 94.9%, 평균 전압효율은 82.2%, 평균 에너지효율은 78.0%를 보였다. 그리고 메타바나듐산 암모늄으로 제조된 전해액을 사용한 VRFB의 각 효율은 바나딜 설 페이트(VOSO4)로 제조된 전해액을 사용한 VRFB의 각 효율과 비교하여 거의 동등한 값을 갖는다는 것을 확인하였다.
This research proposes an optimal flushing operation technique in an effort to prevent secondary water pollutions and accidents in aged pipes, and to improve the cleaning effect of unidirectional flushing. Water flow directions were analyzed using EPANET 2.0, while flushing and air scouring experiments in forward and reverse directions were performed in the field. In 42 experiments, average residual chlorine concentration and turbidity were improved after cleaning compared to before cleaning. It was found that even when the same cleaning method was used, further improvement of cleaning effect was possible by applying air injection and reverse direction cleaning techniques. By means of one-way ANOVA(Analysis of variance), it was also possible to statistically verify the need of actively utilizing air injection and reverse direction cleaning. Based on correlation between turbidity and TSS, the total amount of suspended solids removal was estimated for 874 flushing operations and 194 air scouring operations. The result showed that air scouring used more discharge water than flushing by an average of 4.9 m3 yet with larger amounts of suspended solids removal by an average of 145.9 g. The result of analysis on turbidity values from 887 flushing operations showed low cleaning effect of unidirectional flushing for the pipes with diameters over 300 mm. In addition, the turbidity values measured during cleaning showed an increasing tendency as pipe age increased. The methodology and results of this research are expected to contribute to the efficient maintenance and improvement of water quality in water distribution networks. Follow-up research involving the measurement of water quality at regular time intervals during cleaning would allow a more accurate comparison of discharge water quality characteristics and cleaning effects between different cleaning methods. To this end, it is considered necessary to develop a standardized manual that can be used in the field and to provide relevant trainings.
The purpose of this paper is to find out how each districts(Gu) of Seoul are related based on the apartment price trends. All the data used in this paper comes from a public data sources, Seoul apartments transaction data provided by ‘Ministry of Land Infrastructure and Transport Korea’ and the apartments properties from NAVER’s real estate service. To analyze the similarities between the price trends of each apartments, this study uses FastDTW algorithm which is quite popular in time series analysis domain. After figured out the distance matrix from FastDTW, this study uses Hierarchical Clustering algorithm and Chi-squared test to compare each districts’ relationship. The analysis result shows that which districts in Seoul are similar and which districts are not.
바나듐 산화환원 흐름 전지에 핵심적으로 사용되는 이온교환막은 일반적으로 양이온교환막을 사용하고 있으나 co-ion인 바나듐 이온의 투과에 의한 장기적 성능 저하 문제를 해결하기 어렵다. 따라서 본 연구에서는 바나듐 투과도 및 장 기 운전 안정성의 특성을 파악하기 위해 세 가지 다른 관능기를 보유한 음이온교환막을 제조하였다. 기저막으로는 다공성 폴 리에틸렌 필름에 benzyl chloride (VBC)과 divinylbenzene (DVB)을 충진 및 가교 중합하여 제조한 후, 세 가지 다른 아민 관 능기를 각각 도입하였다. 제조된 음이온교환막들에 대해 바나듐 이온 투과 정도 및 장기 운전 안정성을 관찰한 결과 triethylamine을 관능기로 적용한 음이온교환막에서 높은 에너지효율을 유지하면서도 가장 장기적 운전 안정성을 확보할 수 있었다.
이 연구의 목적은 한국과 미국의 테러대응 입법 및 개정과정에서의 정 책의 변동과정을 정책흐름모형을 적용하여 심층 검토함으로써 정책적 함 의를 찾고 향후, 우리나라의 테러방지법을 발전을 위한 의사결정과정의 효율성을 제고하는데 있다. 이를 위해 9/11 테러사건 이후 현재 적용되 고 있는 테러대응 법률 입법과정에 대한 기존연구와 정책흐름 모형의 선 행연구를 검토하였다. 그리고 우리나라의 테러방지법과 미국의 애국법· 자유법의 입법절차와 법적용에 있어서의 쟁점사항을 분석하였다. 연구 결과, 첫 번째 김대중 정부(16대 국회)∼노무현 정부(17대 국 회)∼이명박 정부(18대 국회)에서는 국가전체의 절박성과 정책선도자의 의지가 부족하여 정치의 흐름을 이끌지 못하였지만, 박근혜 정부(19대 국회)에서는 여당의 국회의원들은 강한 의지를 가지고 입법안을 발의하 는 등 정책선도자로서 정부의 강력한 법제정 추진의지에 의해서 법을 제 정할 수 있었다. 또한 2015년 11월 파리 동시다발 테러사건과 북한의 핵 문제 등 안보현안이 정책변동의 영향력으로 결정적으로 활용될 수 있 었다. 그러나 국회를 통과하는 과정에서 진보진영의 반대에 대한 타협안 을 만들면서 테러의 정의, 테러위험인물의 범위 등 중요한 법 목적에 관 련된 사항을 양보하여 정책의 성과 면에서 실효성이 부족하다는 평가를 피하지 못하고 있다. 두 번째, 미국의 경우 9/11 테러사건이라는 전대미문의 테러의 공포가 미국 전체를 패닉상태로 몰아넣었다. 부시행정부(114대 연방의회)는 안 보매파의원의 주도로 국가정보기관에게 무차별적 개인정보 수집 등 시민 의 자유와 사생활 보장이라는 선진민주주의의 가치를 희생시키면서 애국 법을 제정하는데 성공하였다. 테러사건 이후 불과 20여일 만에 이룬 법 제정의 성과였다. 그 후 여러 인권관련 사건을 거치면서 시민의 자유와 사생활 보장을 위한 법의 개정을 주장하였고 10여 년 동안 꾸준히 애국 법 개정안을 내놓았다. 그러나, 2013년 에드워드 스노든(Edward Joseph Snowden) 폭로사 건은 애국법을 개정하기 위한 결정적인 계기로 작용하였다. 애국법 연장 에 대한 안보매파들의 법 수호 의지는 극렬했으나 오바마 대통령은 상원 을 압박하여 자유법을 통과시켰다. 이 과정에서 정략적 차원을 넘어서 공화당원 중에서도 애국법 제정을 주장하였고, 긍정적 정책변동과정은 국가안보’와 ‘미국시민의 기본권 보장’의 균형을 이루었다는 평가를 받으 면서 현재까지 현행법으로써의 역할을 다하고 있다. 2016년 3월 3일 우리나라도 숱한 정책변동을 겪으면서 테러방지법을 보유한 국가가 되었지만 정책성과면에서 부족한 점이 많다는 비판을 받 고 있다. 테러의 정의, 테러위험인물의 범위 등 개정해야 할 여지가 많다 는 관계자들의 의견이 또한 비등하다. 무엇보다도 이러한 정책산출(정책 성과)의 실효성이 부족한 우리의 정치문화를 되짚어봐야 한다. 그리고 앞으로 정책산출이 높은 테러방지법으로 개정·보완하기 위하여 의사결 정 과정에 있어서 효율성을 제고할 수 있어야 할 것이다.
A membrane bioreactor by sequentially alternating the inflow and by applying a two-stage coagulation control based on pre-coagulation was evaluated in terms of phosphorus removal efficiency and cost-savings. The MBR consisted of two identical alternative reaction tanks, followed by aerobic, anoxic and membrane tanks, where the wastewater and the internal return sludge alternatively flowed into each alternative reaction tank at every 2 hours. In the batch-operated alternative reaction tank, the initial concentration of nitrate rapidly decreased from 2.3 to 0.4 mg/L for only 20 minutes after stopping the inflow, followed by substantial release of phosphorus up to 4 mg/L under anaerobic condition. Jar test showed that the minimum alum doses to reduce the initial PO4-P below 0.2 mg/L were 2 and 9 mol-Al/mol-P in the wastewater and the activated sludge from the membrane tank, respectively. It implies that a pre-coagulation in influent is more cost-efficient for phosphorus removal than the coagulation in the bioreactor. On the result of NUR test, there were little difference in terms of denitrification rate and contents of readily biodegradable COD between raw wastewater and pre-coagulated wastewater. When adding alum into the aerobic tank, alum doses above 26 mg/L as Al2O3 caused inhibitory effects on ammonia oxidation. Using the two-stage coagulation control based on pre-coagulation, the P concentration in the MBR effluent was kept below 0.2 mg/L with the alum of 2.7 mg/L as Al2O3, which was much lower than 5.1∼7.4 mg/L as Al2O3 required for typical wastewater treatment plants. During the long-term operation of MBR, there was no change of the TMP increase rate before and after alum addition.
The influencing factors to remove phosphate were evaluated by converter slag (CS). Experiments were performed by batch tests using different CS sizes and column test. Solutions were prepared at the different pH and concentrations. The maximum removal efficiency was obtained over 98% with the finest particle size, CSa within 2 hours in batch tests. The removal efficiency was increased in the order of decreasing size with same amount of CS for any pH of solutions. The adsorption data were well fitted to Freundlich isotherm. From the column experiment, the specific factors were revealed that the breakthrough removal capacity (BRC) xb/mcs, was decreased by increasing the influent concentration. The breakthrough time, tb was lasted shorter as increasing the influent concentration. The pH drop simultaneously led to lower BRC drop during the experimental hours. The relation between the breakthrough time and the BRC to influent concentration was shown in the logarithmic decrease. Results suggested that the large surface area of CS possessed a great potential for adsorptive phosphate removal. Consequently particle size and initial concentration played the major influencing factors in phosphate removal by converter slag.
현대사회는 기후변화, 지구 온난화, 생물다양성 감소 등 의 환경문제를 해결하기 위한 일환으로 저탄소사회의 구현 을 지향하고 있으며, 이를 실현시킬 수 있는 저탄소도시가 새로운 패러다임으로 등장하게 되었다(Lee, 2005; Lee, 2012). 저탄소도시는 도시내 탄소 배출량을 감소시키는 것 을 목표로 자원순환, 탄소흡수원 확충, 신재생에너지, 자연 재난예방, 기후계획 등의 다양한 대안을 제시하고 있다 (Koh et al., 2011). 특히 도시내 생태조경공간은 탄소흡수 원으로서의 중요성이 더욱 강조되고 있으며, 이러한 관점에 서 탄소배출을 최소화하여 저탄소사회를 실현가능하게 하 는 요소로 이루어진 저탄소경관의 개념이 등장하게 되었다. 저탄소경관이란 기존 경관의 형성과 관련된 구성자원 중 기후변화, 특히 온실가스인 탄소에 초점을 둔 개념으로 (You et al., 2015), 저탄소경관을 창출하기 위해서는 생태 조경공간 내 시설, 재료, 식재의 탄소흡수와 배출에 대한 복합적인 관계를 시간변화에 따라 동태적으로 파악해야 할 필요가 있다. 옥상습지는 녹지가 부족한 도시에서 탄소를 저감시킬 수 있는 식생, 토양, 습지 등의 요소들로 이루어져 (Lee et al., 2013) 저탄소경관을 창출할 수 있는 공간으로 기대되고 있다. 따라서 본 연구의 목적은 생태조경공간의 탄소흐름 변화에 대한 시뮬레이션 모형을 구축하기 위해, 저탄소경관 구성자원인 시설, 재료, 식재를 활용하여 옥상 습지 내 탄소흐름구조를 모형화하는 것이다. 본 연구에서는 탄소의 흐름에 대한 구조와 시뮬레이션 모형의 구축을 위해, 탄소흐름현상에 대한 인과순환적 분석 과 시간의 흐름에 따른 시스템의 동태적인 분석이 가능한시스템 다이내믹스(System Dynamics) 이론을 적용하였다 (Williams and Richard, 2010). 본 연구의 절차는 3단계에 걸쳐 이루어졌으며 시뮬레이션 모형을 구축하기 위한 기초 연구를 수행하였다. 첫째, 옥상습지의 시설, 재료, 식재에 따른 탄소흐름구조를 파악하고 시뮬레이션 모형에 활용될 식과 데이터를 수집하였다. 둘째, 시뮬레이션 모형에 사용 될 변수 유형을 저량변수(Stock variable), 유량변수(Flow variable), 보조변수(Converter)로 구분하고 수집한 식과 데 이터를 변수의 유형에 맞춰 분류하였다. 셋째, 분류한 변수 를 바탕으로 전체적인 탄소의 흐름을 모형화하였다. 연구의 공간적 범위는 주변의 낮은 녹지율로 인한 생태네트워크의 단절과 지역주민들이 이용 가능한 야외녹지 시설의 부족으 로 인해 2008년 준공된 서울시 강남구청 본관의 옥상습지 로 한정하였다. 강남구청 옥상의 녹지면적(1,477m2)은 전 체 옥상의 면적(1,799.3m2)중 80% 이상의 공간에 조성되었 으며 옥상습지 내부에는 안내판, 파고라, 벤치, 조명등과 같 은 시설과 습지, 데크, 토양, 잔디와 같은 재료로 구성되어 있으며 교목, 관목, 초본류 등 다양한 수목이 식재되어 있어 탄소흐름의 시스템 구조를 파악하기 위한 대상지로서 적합 하다. 연구의 내용적 범위는 옥상습지를 중심으로 하여 일 어나는 탄소의 흐름으로 한정하였다. 먼저 옥상습지의 시설, 재료, 식재에 따라 시뮬레이션 모 형에 활용될 식과 데이터를 수집하여 분석한 결과는 다음과 같다. 저탄소경관의 구성자원 중 시설에 해당하는 건물에서 탄소를 배출하는 요소는 전력, 수도, 가스 등으로 나타났으 며, 강남구청에서 실제로 구축된 전력, 수도, 가스 사용량에 대한 자료와 2006 IPCC 가이드라인(이하 2006 IPCC G/L) 을 기준으로 사용량과 탄소배출계수를 이용하여 탄소배출 량을 산정하였다(Ahn et al., 2012). 또한 저탄소경관의 구 성자원 중 재료에 해당하는 토양에서 탄소를 흡수하고 저장 하는 요소는 토양 자체로 나타났으며 토양의 탄소저장량도 건물에서의 탄소배출량과 마찬가지로 2006 IPCC G/L에 의거하여 토지이용, 관리체계, 유기물 투입에 대한 계수들 과 각 지목의 면적을 곱하여 산정하였다(Hwang et al., 2014). 마지막으로 강남구청 옥상습지의 식재는 소나무, 황 금측백 등의 상록교목과 산수유, 자작나무, 청단풍, 홍단풍 등의 낙엽교목, 눈향나무, 영산홍, 회양목 등의 상록관목과 등나무, 병꽃나무, 백당나무, 산수국, 조팝나무, 황매화 등의낙엽관목 등으로 구성되어 있었다. 식재의 탄소 흡수와 배 출에 관한 식은 기존 교목과 관목류의 수목들을 토대로 임 목축적을 기초로 하거나 상대성장식을 활용하는 방법, 흉고 직경 또는 근원직경을 이용하여 다양하게 탄소저장량이나 흡수량을 산정하는 방법이 있지만, 본 연구에서는 수목의 흉고직경, 근원직경 및 개체수를 이용하여 수목의 탄소흡수 량과 저장량을 산정하였다(Park, 2009; Hwang and Park, 2011). 이후 탄소흐름의 식과 계수를 추정하여 시뮬레이션 모형을 구축하기 위해 시설, 재료, 식재의 변수들을 저량변 수(Stock variable), 유량변수(Flow variable), 보조변수 (Converter)로 구분하였다. 대기 중의 탄소량과 토양에 저 장되는 탄소량, 그리고 식물이 저장하는 탄소량은 물리적으 로 축적이 계속 이루어지므로 저량변수(Stock variable)로 설정하였으며, 건물에서 배출되는 탄소량과 토양과 식생이 흡수하거나 저장하는 탄소량의 변화는 물리적인 축적이 일 어나게 하는 흐름이므로 유량변수(Flow variable)로 설정하 였다. 마지막으로 이러한 흐름변수를 결정짓는 계수나 상수 등의 값들은 보조변수(Converter)로 설정하였다. 이를 통해 강남구청 옥상습지의 시설, 재료, 식재의 탄소흐름 관계 파 악을 위한 변수들 간의 관계를 통합하여 옥상습지 전체의 탄소흐름을 모형화하였다. 본 연구는 생태조경공간인 강남구청 본관 옥상습지에서 저탄소경관 구성자원인 시설, 재료, 식재의 탄소흐름과 그 변수에 투입될 식 또는 계수를 탐색하여 탄소흐름 시뮬레이 션 모형 구축을 위한 기초연구를 수행하였다. 이를 위해 옥 상습지 시설의 탄소 배출량에 대한 산정식을 파악하였고 재료에 해당하는 토양의 탄소 흡수량 및 저장량과 옥상습지 식생의 탄소 흡수량과 저장량을 산정하였다. 아울러 시설, 재료, 식재와 같은 단일 구성자원들 간의 관계를 하나의 모 델로 통합하여 시간에 따른 변화 양상에 대한 모형을 구축 하기 위한 기초연구를 진행하였다는데 의의가 있다. 향후, 본 연구에서 구축한 기초모델에 대한 타당성 검토를 통해 탄소의 흐름이나 패턴, 변화가 모델에서 적절하게 구현되었 는지에 대한 검증작업을 수행할 예정이다. 궁극적으로는 옥 상습지의 탄소흐름 모델링을 통해 저탄소경관 창출을 위한 디자인요소를 개발할 수 있을 것으로 기대한다.
PURPOSES: As a part of our research into repair techniques for roads that have collapsed as a result of a natural disaster, this study set out to find the optimum mix proportion for gravels to be used to restore a damaged area.
METHODS: This study considered flow and strength-development characteristics. The experimental variables were the W/C ratio, the usage of the admixture, the types of cement, and the quantity of fine aggregate over three different experimental stages. The compressive strength was measured at 12 hours, one day, three days, and seven days.
RESULTS : The flow varied with the amount of fine aggregate and the use of a high-range water-reducing (HRWR) admixture. The compressive strength also varied with respect to the type of cement and the W/C ratios. The strength satisfied the expected requirement of 21 MPa after one day, provided the mix proportion was appropriate.
CONCLUSIONS: A gravel-filling high-flow cement-based mortar exhibited strength and consistency with a W/C ratio in the range of 0.40 to 0.45, assuming the use of HRWR at 0.5 to 0.7% and a fine aggregate/cement ratio of 1.0 to 1.5.
두 종류의 막(다공성 막, 양이온교환막)을 사용하여 아연-브롬 레독스-흐름 전지(ZBRFB, Zn-Br redox-flow battery)의 성능을 평가하였다. ZBRFB의 성능평가는 20mA/cm2의 전류밀도에서 진행하였다. 다공성 막인 SF-600을 사용한 ZBRFB의 기전력(SOC 100%에서의 OVC)은 1.87 V, 양이온교환막인 Nafion117 막을 사용한 ZBRFB의 기전력은 1.93 V를 나타냈다. 각 막을 사용한 ZBRFB의 성능은 7회 충 방전 실험을 진행하여 평가하였다. SF600 막을 사용한 ZBRFB의 평균 전류효율은 89.76%, 평균 전압효율은 83.46%, 평균 에너지효율은 74.88%를 나타냈으며, Nafion117 막을 사용한 ZBRFB의 평균 전류효율은 97.7%, 평균 전압효율은 76.33%, 평균 에너지효율은 74.56%를 나타냈다.