검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 19

        1.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Because the inner environment of greenhouse has a direct impact on crop production, many studies have been performed to develop technologies for controlling the environment in the greenhouse. However, it is difficult to apply the technology developed to all greenhouses because those studies were conducted through empirical experiments in specific greenhouses. It takes a lot of time and cost to develop the models that can be applicable to all greenhouse in real situation. Therefore studies are underway to solve this problem using computer-based simulation techniques. In this study, a model was developed to predict the inner environment of glass greenhouse using CFD simulation method. The developed model was validated using primary and secondary heating experiment and daytime greenhouse inner temperature data. As a result of comparing the measured and predicted value, the mean temperature and uniformity were 2.62°C and 2.92%p higher in the predicted value, respectively. R2 was 0.9628, confirming that the measured and the predicted values showed similar tendency. In the future, the model needs to improve by applying the shape of the greenhouse and the position of the inner heat exchanger for efficient thermal energy management of the greenhouse.
        4,000원
        2.
        2020.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        겨울철 벤로형 유리온실(W59×L68×H5.9m) 보온스크린 높이의 차이에 따른 실내온도 변화를 파악하기 위하여 00시부터 04시까지 30분 간격으로 열유동해석을 하였다. 초기에는 상대적으로 난방 외부접촉면적이 큰 보온스크린 설치높이 5.9m에서 보온스크린 설치높이 4.1m에 비해 온도감소가 빨라 낮은 온도를 나타냈으나 해석 2시간 이후부터는 상대적으로 온도감소가 느렸고 04시에는 0.6°C 높았다. 그러나 해석시작 1시간 후 실내온도가 약 13°C까지 내려가고, 그 이전에 난방기가 작동해야 된다고 볼 때, 해석 2시간 동안 온도감소가 상대적으로 느렸던 보온스크린 설치높이 4.1m에서 5.1m에 비해 난방에너지 절감에 유리할 것으로 판단되었다. 토마토가 자라는 지면 2m 높이에서의 유동은 보온스크린 설치높이 5.9m에서 4.1m에 비해 상대적으로 넓고 빨랐으며 유동해석 1시간 후인 01시의 평균차이는 0.034m·s-1였다. 여름철 차광스크린 설치높이를 5.7m와 3.9m로 달리하되 70%닫힘 조건에서 12시부터 13시까지는 온실하부덕트 외부 공기유입량 0.67m3·s-1 상태 그 후부터는 외부 유입공기를 3배로 증가하여 냉방효과를 비교하였다. 초기 12시부터 13시까지는 차광스크린 70%닫힘 상태에서 무차광에 비해 오히려 평균 약 0.9°C 높았지만 외부공기유입량이 증가하는 13시 이후 부터는 차광스크린 70%닫힘 조건에서 온도가 감소하였고 14시 30분에는 무차광에 비해 0.5°C 낮았다. 차광스크린 70% 닫힘 조건에서 바닥면의 온도분포는 스크린 설치높이와 개방 정도에 비례하여 낮았으며 무차광에 비해 8°C이상 낮았다. 온실 내 상대습도는 차광스크린을 30% 개방하는 조건에서는 차광스크린의 높이나 개방정도에 따른 차이가 미미하였다.
        4,000원
        3.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 유리온실 경영비 절감을 위한 고효율 난방기술을 개발하기 위하여 지하수열원 히트펌프, 알루미늄 다겹보온커튼, 근권부 국소난방장치를 조합한 난방 패키지 모델을 구성하고 파프리카 재배 벤로형 유리온실에 적용 시험을 수행하였다. 적용효과 분석을 위하여 관행 경유온수보일러와 일반 보온커튼을 설치한 대조구 온실과 비교시험을 통해 온실환경, 난방비용, 작물생육 등을 검토하였다. 알루미늄 다겹보온커튼과 일반 부직포 보온커튼을 설치한 온실에 대한 무가온 조건에서의 야간 온도 비교시험에서 알루미늄 다겹보온커튼 설치 온실의 온도가 일반 부직포 보온커튼 설치 온실에 비해 평균 2.2oC 더 높게 유지됨을 확인하였다. 또한 근권부 국소 난방장치를 설치한 온실에서 미설치 온실에 비해 야간 난방 중의 베드내부 근권온도가 4.7oC 더 높게 유지됨을 확인하였다. 난방패키지를 구성하는 지하수열원 히트펌프의 난방성능을 분석한 결과 지하수를 직접 열원으로 이용하는 시스템 특성상 난방성능계수는 평균 3.7로 비 교적 높게 나타났다. 난방패키지를 적용한 처리구 온실과 관행 난방의 대조구 온실에 대하여 연료소비량을 계 측한 결과 10a(1,000m2)당 대조구 온실은 경유 14,071L, 전력 364kWh를 소비하였고, 처리구는 전력 35,082kWh 를 소비하여 난방비용 기준으로 대조구 온실의 비용 절감율은 87%로 나타났다. 처리구 및 대조구 온실의 작물 생육을 비교한 결과 초장과 엽록소 함량에서 차이가 발생하였으나 두 온실의 난방온도가 거의 동일하므로 전체적인 생육은 큰 차이가 없는 것으로 분석되었다. 원예시설의 난방에너지 절감효과를 극대화하기 위해서는 본 연구의 난방패키지를 구성하는 개별 기술뿐 아니라 이미 개발된 고효율 공조기 이용기술, 보온성 향상기술, 온도 관리 기술 등을 지역, 시설, 작목, 작형 등에 최적화하여 조합할 수 있는 추가적 패키지 모델의 개발 연구가 필요한 것으로 판단되었다.
        4,000원
        4.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A new design concept for integrated thermal energy storage system is suggested to increase energy saving rate for heating and cooling system of the closed glass greenhouse. Heat pump of air source is installed in the mechanical room and air flows then controlled by damper system located between the greenhouse and outdoor environments. A damper control algorithm is designed to enhance the usage of excessive energy in the glass greenhouse. Since the proposed system is installed at the actual glass greenhouse site for experimental verification of energy savings, the proposed system with damper control is compared with conventional greenhouse heating and cooling system. From results, it is found that more than 10% increase of energy saving rate is achieved.
        4,000원
        5.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        새만금 인근의 간척지 유리온실에서 파프리카의 암면재배시LED 보광처리효과를 실험하기 위하여 본 연구를 시행하였다.식물체는 자연광, LED로 처리하여 일출 후 점등하여 일몰 약1시간전에 소등하였다. 실험의 결과는 다음과 같다. 1. 파프리카 초장은 ‘더비’품종에서는 자연광처리구에서 1월측정 초장이 29cm 더 신장되었다. 2. 1-2월 파프리카의 1주당 수량은 LED 보광처리구 및 자연광처리구에서 ‘쿠프라’품종에서는 764g 및 392g로, LED보광처리구에서 95% 증수되었으며, ‘콜레티’품종에서는 624g 및292g로, LED보광처리구에서 114% 증수되었다. 3. 재배기간 전체의 파프리카 상품수량은 ‘쿠프라’품종에서LED보광처리구에서 7,342g/㎡로 자연광처리구의 4,878g/m2에 비하여 51% 증수되었다.
        4,000원
        6.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        간척지에서 대단위 유리온실 단지 조성에 대비하여 현장에서 필요한 기술을 개발하고자 전북 부안군 계화면에 벤로형 고측고 유리온실을 설치하여 파프리카를 품종별로 재배하여 일반농가와 생육과 수량을 비교하였다. 재배방식은 행거식 벤치시스템을 사용하여 암면 수경재배를 실시하였으며, LPG를 연소한 액화탄산가스를 낮동안 평균 500~600mg․L-1이 되게 공급하였고, 수평식 지열히터펌프를 활용하여 주로 야간에 22~24℃ 이하가 되도록 온도를 관리하였다. 양액의 관리는 순환식 시스템을 이용하였으며, 누적일사량 500J 마다 공급하여 배액을 20~40% 정도 유지하게 하였다. 재배기간 동안 칠레이리응애 등 9종의 천적을 응애, 진딧물, 총채벌레, 가루이, 나방류가 발생이 확인될 때 투입하여 무농약으로 재배하였다. 농가에서 많이 재배되는‘쿠프라’,‘콜레티’,‘부기’의 3품종을 재배한 결과 10a당‘콜레티’의 수량이 가장 많은 21.18ton,‘쿠프라’가 18.54ton,‘부기’가 15.45ton 순이었다. 경남과 전북의 일반농가와 10a당 수량을 비교한 결과 함안농가는 14.52ton, 창원농가는 20.89ton, 김제농가는 16.21ton을 각각 수확하여 수량성은 큰 차이가 없었다. 월별 수량을 비교한 결과 1그룹이 수확되는 12월에 수량이 높았으나, 1월에 감소한 후에 일사량이 많아지는 7월까지 증가하였다. ‘쿠프라’품종에 대하여 생육상황을 일반농가와 비교한 결과 평균 분지길이(방아다리)는 경남 창원의 유리온실에서 가장 짧았고, 경남 함안의 비닐하우스에서 재배한 경우 계화도의 유리온실과 비슷하게 길었다. 초장과 마디수는 계화도 유리온실에서 가장 양호하였으나, 착과수는 전북 김제의 유리온실에서 가장 많은 19.6개/주 정도였다. 이상의 결과로 볼 때 전북 계화면 간척지에서 유리온실을 설치하여 파프리카를 재배할 경우 다른 농가와는 큰 차이 없이 수량을 확보할 수 있었고, 천적을 활용한 무농약 재배 및 순환식 수경재배가 가능하였다.
        4,000원
        7.
        2011.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 한국형 온실 표준설계도 및 Greenhouse Structure Design Manual(1999)에 의거하여 최대설계 하중을 받는 와이드스팬형파 2-bay벤로형 온실시스템에 대하여 해석적 연구를 진행하였다. 상부구조물을 라멘형식으로 단순화한 구조형식에 BOX형 및 I형 단면을 적용하여 다음과 같은 결과를 얻을 수 있었다. 한국형 유리용실 표준도를 활용하여 라멘형식의 단순화된 와이드스팬형 및 2-bay 온실구조시스템의 안전성 평가결과 기존의 트러스 등의 보강재가 적용되지 않을 경우 안전성확보에 문제가 발생할 수 있음을 확인할 수 있었다. 또한 유리온실 표준도를 라멘형식으로 단순화하고 Greenhouse Structure Design Manual (1999)이 제안하고 있는 최대하중에 대해 경량I형 단면 부재를 적용할 경우 안전성을 확보할 수 있다. 본 연구에서는 경제적인 경량 I형 단면 3가지의 적용성을 평가하였으며, 검토조건에 부합하는 최소 기둥단면(H200×175×3.2×6)을 제시하고 있다. 와이드스팬형 및 벤로형 온실형식의 안전성평가에서 발생되는 처짐은 매우 작은 값을 나타내고 있으며, 발생되는 응력이 보다 민감하게 발생하는 것을 알 수 있다. 따라서 검토된 온실표준단변형식이 전체적인 구조변형에는 안전하나 응력발생이 일부부재에서 취약함으로 변단면 등을 활용하여 경제성을 확보할 수 있다. 온실의 채광량, 시공성 및 안전성을 고려하여 벤로형 구조시스템이 널리 사용되고 있으며, 지붕높이의 변화를 통하여 보다 경제적인 형식이 개발가능하며, 3-bay 벤로형의 추가적인 연구가 필요하다.
        4,000원
        8.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        경상대학교 농장 벤로형 유리온실(280m2)에 적외선등 난방 시스템을 설치하였다. 분식물 호접난, 홍콩야자나무, 무늬고무나무, 장미에 대한 적외선등 난방 시스템의 가 열효과를 알아보고자 열화상 카메라를 이용하여 온도 변화를 측정하였다. 그리고 난방의 효과를 적외선등 난방 시스템 ‘On’과 ‘Off’로 달리하여 실험을 수행하였고 적외 선등 난방 시스템의 경제성을 분석하였다. 온실 내부 설 정온도가 18oC일 때 식물체의 엽온도는 22.8~27oC, 화분 에 담겨 있는 배지의 온도는 21.3~24.3oC이었다. 관엽식 물과 같이 키가 큰 작물은 상부의 온도가 홍콩야자나무와 무늬고무나무 각각 24.0oC와 26.9oC로 가장 높았고, 아래 로 내려오면서 점점 온도가 내려가는 경향을 보였다. 열 화상 카메라를 이용한 온도 변화 관찰을 통하여 적외선등 난방 시스템을 이용한 온실내 작물의 가열 효과는 충분함 을 알 수 있었다. 장미의 경우 적외선등 난방 시스템을 이용한 난방의 경우 밤과 새벽 사이 외부 기온이 많이 떨어지는 시점에도 설정온도(18oC)에 가깝게 유지되고 있었다. 특히 ‘On’ 상태에서 근권부 평균온도는 21.8oC 이었고, 엽의 평균온도는 17.8oC이었다. ‘Off’ 상태의 경우 근권부 평균온도가 20.4oC이었고, 엽의 평균온도는 15.5oC 로 뚜렷한 차이를 보였다. 난방부하량은 약 24,850~ 35,830 kcal·h−1 정도로서 이 때 난방비를 경유로 환산 하면 약 27,000~40,000원 정도였다. 소비전력량과 전력요 금은 각각 330~560 kWh 및 8,600~14,800원 정도였다. 즉 전체적으로 단순비교해 볼 때, 적외선등 난방 시스템을 사용할 경우 경유 온수보일러에 비해 난방비용이 약 35% 정도 밖에 소요되지 않는 것을 알 수 있다. 적외선등 난방 시스템을 이용한 난방의 경우 야간 시간대에 공기온도가 설정온도 보다는 다소 낮게 유지되고 있음을 알 수 있다. 즉, 유리온실의 경우 밀폐성이 좋지 않아서 공기온도를 설정한 온도수준으로 유지되지 못하는 것으로 판단되어 향후 유리온실에서 적외선등 난방 시스템을 이용하는 경우 설치간격, 센서 부착위치 및 공기대류 등에 대한 연구가 더 필요하다고 생각된다.
        4,000원
        9.
        2009.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 현재 대일 수출중인 상업적인 유리온실과 플라스틱 온실에서 파프리카 'Derby'를 공시품종으로 하여 국내 온실 간 생산량 차이 발생을 분석하여, 생산성 차이를 개선하고자 시설내부의 광량, 작물의 생장량 및 수량을 두 온실간 기간별로 비교 분석하였다. 재배기간 동안 평균 일중 광량은 유리온실 9.03MJ/m2/day, 플라스틱 온실 7.37MJ/m2/day로 23%정도 유리온실의 시설내부 광량이 많았다. 총 조사기간 동안 파프리카의 생장량은 유리온실 1759.9g·m-2, 플라스틱 온실 1308.5g·m-2으로 유리온실의 작물 생장량이 높았다. 총 건물생산량 대비 영양생장생식생장 기관의 건물분배는 시설내부 광량이 높은 유리온실에서 생식생장 기관의 건물분배는 높았고, 영양생장 기관의 건물분배는 낮았다. 두 온실의 파프리카 생산성은 유리온실 14.1kg·m-2, 플라스틱 온실 7.8kg·m-2으로 유리온실이 매우 높은 생산성을 보였다. 본 연구결과는 온실 간 파프리카의 기간별 동적인 건물생산량과 건물 분배 패턴, 수량을 분석함으로써 파프리카의 수량을 예측하고 우리나라 파프리카 생산성 향상을 위한 재배기술 분야의 기초 자료와 농가 간 생산성 차이 원인을 분석하고 그에 따른 생산성 극복 기술을 개발하는데 중요한 자료가 될 것이라고 판단된다.
        4,000원
        10.
        2009.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Without pesticide applications, mass-trapping by sex pheromone was successful to control Spodoptera litura (Fabricius) in a large scale tomato glasshouse (10,000 ㎡) at a low cost of 60 won/㎡. Pheromone traps were placed both inside and outside of the glasshouse. Inside the glasshouse traps were installed in a regular space, one trap per 500 ㎡, to catch the moths that were present in the glasshouse, and traps were also set outside of the glasshouse, at intervals of ca. 20 m, to prevent the moths from invading the glasshouse. In the experiment, more than 400 S. litura were captured per trap.
        4,000원
        11.
        2008.05 구독 인증기관·개인회원 무료
        김제시 만경읍에 위치한 5,000㎡ 규모의 토마토 유리 온실에서 담배가루이의 분포 특성을 조사하였다. 유리온실을 66개(11×6)의 구획으로 나누고 구획 별로 토마토 한 주를 임의로 선택한 다음, 각 결과소지 바로 위에 있는 우상복엽에서 한 잎을 절취하여 현미경을 이용하여 검경하였다. 선택된 잎은 상부에서부터 차례로 번호를 부여하였다. 대체로 1번 잎은 신초 부위, 2번 잎은 한 개 이상의 꽃이 핀 결과소지의 바로 위쪽, 3번 잎은 꽃이 모두 만개하였거나 한 개 이상의 과실이 형성되기 시작한 결과소지 바로 위쪽에서 선택되었으며, 주당 평균 7개의 잎을 조사하였다. 조사기간은 2008년 1월 초부터 4월 초까지이며, 1~2주 간격으로 총 10회에 걸친 조사가 이루어졌다. 조사 기간 동안 담배가루이의 밀도가 기하급수적으로 증가하였기 때문에, 6회 조사 직후인 3월초에 스피로메시펜을 처리하여 방제하였다. 약제처리 직후 담배가루이 알의 밀도는 급격하게 감소하였지만, 약충의 밀도는 일시적인 증가추세를 유지하였다. 담배가루이의 토마토 주내 분포는 잘 분화된 층위구조를 보였는데, 알은 3번 잎에서 가장 많았고, 1령 약충은 4~5번 잎에서 가장 많았으며, 나머지 약충과 번데기ㆍ탈피각은 6~7번 잎에서 가장 많았다. 온실 전체의 담배가루이 밀도 분포 또한 안정적인 구조를 유지하였는데, 조사를 시작할 때 담배가루이 밀도가 높았던 곳이 조사 종료시점까지도 높은 밀도를 유지하였다. 한편 담배가루이는 이웃한 열로 확산되어 옮겨가기 보다는 같은 열의 작업경로를 따라 확산되는 경향을 보였다.
        12.
        2000.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        자연열(태양열)을 효율적으로 이용하기위해 1999년부터 2000년 까지 2년간 상면적이 100m2인 3동의 유리온실에 각기 다른 집열시스템을 설치하였다. 즉, 집열면적과 경사도가 각각 24m2, 50˚로서 현재 시판되고 있는 태양열 집열기(평판형, Solar hart Inc.)를 이용하는 방법, 직경과 송풍량이 각각 1m, 2.5m-3.m-2 .min로서 라디에이터가 부착된 2개의 유동팬을 천장부에 설치하고 천창을 밀폐한 후 온실상부의 열을 집열하는 방법, 온실의 중도리 전부를 물이 순환되는 각관 (75x45x3t, 1m 간격x10줄x온실길이 12m=120m)으로 설치하여 집열하는 방법 등으로 하였다. 각 동마다 지하에 26톤의 저수 능력을 갖는 D2000xW1500xL8600의 축열조를 설치한 후 중간을 막아 저온수조와 고온수조로 구분하였고, 수조 중간 1.5m 높이에 통수로를 내어 일정량의 물(약 15톤)이 지속적으로 순화될 수 있도록 하였다. 최저기온 9℃로 설정하여 1,000m2를 공간 난방할 경우 난방연료 절감율은 태양열 집열기, 유동팬 및 각관에서 각각 7%, 19%, 28%로 나타났다. 태양열 집열기를 이용하는 대부분의 농가에서는 40~50m2 정도의 집열면적을 갖는 집열기를 이용하고 있는데 이 경우 년간 난방연료 절감율은 14% 정도로서 경제성이 없으며, 유동팬도 집열효율에 비해 제작, 설치 및 유지비가 과다하게 소요되므로 경제성이 없다. 각관의 경우 관 자체의 자재비나 설치비에 추가부담이 적으면서 집열효율이 비교적 높기 때문에 관의 부식, 골조 표면적 증가에 의한 시설내 차광 증가, 중도리의 각형 구조로 인한 강도저하 등의 문제가 해결되면 집열 방법으로 고려될 수 있을 것이다.
        4,000원
        13.
        2000.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        여름철 시설내 온도강하를 위해 차광, 포그, 미스트, Fan and Pad 등 다양한 방법들이 행해지고 있고 그 효과에 대해서도 잘 알려져 있다. 그러나 대부분의 효과가 처리방법간 일 최고 기온시의 상대적인 비교를 나타낸 것이므로 실제로 일평균, 순평균하게 되면 그효과는 미미하게 된다. 더구나 우리나라는 8월중 맑은날이 10일 미만이고 상대습도가 놀기 때문에 기화냉각 효과는 더욱 떨어지게 된다. 따라서 여름철 토마토 재배시 온도강하 방법으로 포그처리는 냉방효파에 비해 설치 및 유지관리비에 많은비용이 소요되는 문제가 있고, 온도제어 차광은 지나치게 차광되어 수량감소가 많아 부적합하므로 팬+일사제어 자동차광으로 외기온 가까이 온도를 내리는 것을 목표로 하는 것이 경제적일 것으로 생각된다.
        4,000원
        14.
        1999.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        김과 이(1997, 1998a, 1998b)가 개발한 컴퓨터 시뮬레이션 모형을 이용하여 온실의 골조율과 동길이가 직달일사 및 산란일사 투과율에 미치는 영향을 분석한 결과를 요약하면 다음과 같다. 글조율의 증가에 따라 산란일사 투과율이 조금씩 감소하였으나, 산란일사 투과율에 미치는 골조율의 영향은 작게 나타났다. 동일한 골조율에서 산란일사 투과율에 미치는 동수의 영향은 거의 없는 것으로 나타났다. 단동 또는 연동온실의 기본 골조물을 14.9%로 설정하였을 때 11.3%의 골조율에서 직달일사 투과율은 약 1.5∼3.0% 증가하였으며, 골조율이 18.3%일 때에는 1. 5∼3.0% 낮게 나타났다. 연동 온실에서 골조율의 증가 또는 감소가 직달일사 투과율에 미치는 효과는 동서동과 남북동 온실에서 유사하게 나타났다. 직달일사 투과율의 차이가 동계에 온실내의 식물 생육에 미치는 영향이 크기 때문에, 온실을 설계할 때 구조물의 안전이 유지되는 범위 내에서 내구력을 지닌 경량의 구조재를 사용하여 일사 투과를 각 대화시키는 것이 바람직하다 한편, 동길이가 24.5m 이상인 경우 동서동 또는 남북동에서 직달일사 투과율에 미치는 동길이의 영향은 거의 없는 것으로 나타났다.
        4,000원
        15.
        1998.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        온실내의 일사 투과율을 해석하고자 김과이(1997, 1998)가 개발한 컴퓨터 시뮬레이션 모형을 사용하여 지붕경사각이 온실내의 직달일사 및 산란일사 투과율에 미치는 영향을 분석하였다. 국내의 서울, 전주 및 제주 지역의 10연동 유리온실을 대상으로 지붕경사각이 온실내의 직달일사 및 산란일사 투과율에 미치는 영향에 관한 결과를 요약하면 다음과 같다. 지붕경사각이 15˚, 20˚, 24.6˚ 일 때 산란일사 투과율은 61.3~61.7%로서 거의 일정하였으나, 30。와 35。에서는 56.8~58.6% 로 다소 작게 나타났다. 동계(12월 초순~익년 1월 하순). 춘계(2월 중순~4월 초순) 및 추계(9월 하순~ll월 초순)에 동서동 연동온실에서 직달일사 투과율은 지붕경사각의 영향을 크게 받으나, 하계(5월~8월)에서 직달일사 투과율은 지붕경사각의 영향을 크게 받지 않았다. 즉 동계의 경우 직달일사 투과율이 30˚와 35˚의 지붕경사각에서 높게 나타났으나, 춘계와 추계에서는 20˚의 지붕경사각에서 높게 나타났다. 20˚의 지붕경사각을 갖는 국내의 동서동 온실에서 위도에 따른 직달일사 투과율의 차이가 10월~익년 2월 사이에 나타났으며, 이 시기에 직달일사 투과율은 위도가 낮은 지역에서 높게 나타났다. 남북동 온실의 직달일사 투과율에 미치는 지붕경사각의 영향은 동서동 온실에 비해서 상대적으로 작게 나타났으나, 20˚의 지붕경사각에서 직달일사 투과율이 가장 높게 나타났다. 그러므로 국내에서 직달일사를 많이 확보할 수 있는 온실의 지붕경사각은 20。인 것으로 판단된다. 한편 연동온실의 직달일사 투과율에 미치는 영향은 위도보다 지붕경사각에서 크게 나타났다.
        4,000원
        16.
        1997.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        온실의 동방위 및 지붕경사각, 구조물의 재원, 설치 지역의 위도 등이 단동형 유리 온실내의 직달 및 산란일사 투과에 미치는 효과를 분석하고자 컴퓨터 시뮬레이션 모형이 개발되었다. 개발된 모형은 년중 일수, 온실의 방위 및 설치된 지점의 윈도, 지붕경사각이 서로 다른 단동 및 연동 온실에 대하여 적용할 수 있다. 본 연구에서 수행된 온실의 동방위가 온실내의 직달 및 산란일사 투과율에 미치는 영향에서 얻어진 결과를 요약하면 다음과 같다. 1. 단동의 유리온실에서 계산된 산란일사의 투과율은 60.4%로서, 동방위에 무관하게 일정한 값을 갖는 것으로 나타났다. 2. 겨울철에 직달일사의 투과율은 동서동에서 67∼69% 정도이고, 남북동의 경우 51∼55% 정도로서 동서동에서 14∼16% 정도 높게 나타났다. 3. 여름철에 직달일사의 투과율은 동서동에 서보다 남북동에서 높게 나타났다. 4. 직달일사의 투과율에 미치는 국내 지역간의 차이는 거의 없는 것으로 나타났다.
        4,000원
        17.
        1995.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        여름철 온실 온도환경의 효율적인 제어는 온실의 주년재배와 고도활용을 위한 가장 중요한 당면과제이다. 따라서 본 연구는 우리나라 31개 지역의 기후자료를 분석하여 고온기 온실의 기온관리에 있어서 목표 온도 유지를 위한 지역별 적정 최대환기횟수를 결정함으로서 온실의 기온관리를 위한 기본적인 자료를 제공하고자 실시하였다. 그 결과 여름철 유리온실의 설정온도 유지를 위한 강제환기는 40% 차광 유리 온실에서 최대환기횟수 1회/min로 35℃ 유지가 가능하였으나 환기만에 의한 한계 최고실온 30℃ 유지는 불가능하였다.
        4,000원
        18.
        2014.12 KCI 등재 서비스 종료(열람 제한)
        The whole world concentrates on the reduction of greenhouse gas to effectively cope with policy toward global climate change. To effectively react to climate change, even the agricultural sector requires construction of new farming systems that utilizes new and renewable energy because of rising oil prices and regulations for greenhouse gas emissions. For this reason, we need to fuse the new and renewable energy with the horticulture sector of which the light and heat energy cost accounts for great part, moreover, efforts and researches should me done which can increase income of farmers through reducing carbon dioxide and energy cost in agricultural production expenses. Therefore, this study analyzes economic feasibility and applicability of fusing geothermal heat pump and solar power facilities with high-tech glass greenhouse. As a result, it is concluded that there surely are an applicability and economic feasibility if we apply new development system that can be an alternative for problems of securing premises of existing geothermal heat pump and the RPS system as a power generation company in case of solar power. Therefore, using this analysis data, if new empirical studies fusing and implementing agriculture sector with new and renewable energy fields proliferate and be applied to actual rural and agricultural field, it will increase actual income and will become a new advanced agricultural system that effectively deals with world-wide environmental problems.
        19.
        2009.05 KCI 등재 서비스 종료(열람 제한)
        The aim of this study is investigated greenhouse gas emissions of glass industry, and when calculates greenhouse gas emission, using formula(Tier 3) advising in IPCC(Intergovernmental Panel on Climate Change) and using self designed formula(Tier 3+) authors of this study. Studied to propose calculation formula that can compare these two calculation results and apply to domestic. Formula of Tier 3 calculated to theoretical composition of carbonate material, And Formula of Tier 3+ calculated on the basis of chemical substance formation table that get from glass manufacture company(The S company). As a result, Dolomite, Soda ash, Limestone, Industrial Barium carbonate is calculated value of Tier 3+ lower than value of Tier 3, And Industrial Potassium carbonate, Industrial Strontium carbonate was calculated value of Tier 3 lower than value of Tier 3. This study finding, formula of Tier 3+ has higher confidence than formula of Tier 3 when consider revision about purity of injection raw material. And hereafter, When calculate greenhouse gas emissions about nonmetallic mineral industry, use of Tier 3+ is considered that should be encouraged.