This study is about the design of an elastic support system to isolate the structural noise of the low accumulator of the naval artillery among the equipment mounted on a warship. As the structural noise measurement value of the low accumulator transmitted to the ship exceeded the standard value, a method of applying an elastic mount between the equipment and the ship was devised to isolate the structural noise. By calculating the target vibration isolation efficiency, the vibration isolating system was designed in consideration of design factors such as the system's natural frequency and static displacement. Finally, the performance of the structural noise reduction of the designed vibration isolating system was verified by evaluating the structural noise transmitted to the foundation plate of the equipment from the low accumulator to which designed elastic support system was applied.
OWEC(Overtopping Wave Energy Converter)는 월파된 파도를 이용한 파력발전시스템이라한다. OWEC의 성능 및 안전성은 파고, 주기 등 파도의 특성에 의해 영향을 받는다. 따라서 해역 특성에 따른 OWEC의 최적 형상과 구조안전성에 관한 연구가 필요하다. 본 연구 에서는 울릉읍 연안 해양 환경 데이터를 이용하였으며, SPH(Smoothed Particle Hydrodynamics) 입자법 해석을 통해 기존 케이슨 하부 구조에 변화를 준 모델 4개를 비교하여 월파 효율을 분석하였다. 그 결과, 하부 구조의 변경 및 경량화가 가능함을 확인하였다. 최적화 해석을 통 해 설계 하중에 내하력을 가지는 하부 구조인 새로운 트러스형 구조를 제안하였다. 이후 부재 직경 및 두께를 설계변수로 하는 사례 연구 를 통해 허용응력조건 하에서 구조 안전성의 확보를 확인하였다. 주기적인 파랑 하중을 받기 때문에 제안하는 구조의 고유 진동수와 해 당 해역의 파주기를 비교하였으며, 1년 재현 주기의 파랑을 하중으로 한 조화응답해석을 수행하였다. 제안하는 하부 구조는 동일 가진력 에서 기존 설계 대비 응답의 크기가 감소하였으며, 기존 대비 32% 이상의 중량 절감을 수행하였다.
일반적으로 부유식 해상풍력발전 에너지의 수급성과 효율을 극대화하기 위해서는 하부구조물의 파랑 감쇠로 인한 운동을 저 감시키는 것이 중요하다. 선행 연구들에 따르면 파도 중 하부구조물에 설치된 감쇠판에 의해서 발생한 와류점성으로 인해 운동 응답이 감소되는 것으로 나타났다. 본 연구에서는 5MW급 반잠수식 OC5 플랫폼과 감쇠판이 부착된 두가지 플랫폼을 설계하고, 와류점성으로 인 한 운동저감효과를 확인하기 위해 자유감쇠실험과 수치계산을 수행하였다. 모형시험 결과로 낙하 높이를 30 mm, 40 mm, 50 mm에서의 상하 자유감쇠실험을 수행하였을 때 OC5 플랫폼 대비 두 가지의 형태의 감쇠판이 부착된 플랫폼이 상대적으로 운동감쇠성능이 향상되었다. 모형시험과 수치계산 결과에서 형상화한 감쇠판 모델(KSNU Plate 1, KSNU Plate 2)들이 각각 OC5 대비 상하운동 진폭이 1.1배, 1.3배 각각 감소했으며, KSNU Plate 2 플랫폼은 KSNU Plate 1 플랫폼보다 OC5 대비 약 2배 감쇠성능이 좋아진 것으로 나타났다. 본 연구에서는 감쇠 판의 면적과 와류점성이 상하동요의 감쇠율과 밀접한 관련을 보여준다.
신재생에너지 신규설비 보급이 매년 꾸준히 증가하고 있으며, 그중 개발 확장성이 풍부하고 생산유발계수가 큰 해상풍력 시장이 급성장하고 있다. 특히 서남해 권역은 최고 수준의 해상풍력 잠재량을 보유하고 있으며, 관련 프로젝트들이 추진 중이다. 본 연구는 점토층 지반에 효과적인 해상풍력 하부구조물의 개발에 있어 EUROCODE에 의한 구조물의 설계 절차를 제시하고 구조 안전성을 고찰하여 관련 기술 분야에 이바지함을 목표로 한다. 선행연구에서는 풍력발전기 용량이 5MW급을 주요 대상으로 하였으나, 서남해 해상 풍력발전기 시장의 기술 추세에 부합하는 발전 용량 8MW급을 연구 모델로 선정하였다. 이에 본 연구에서는 서남해 지질 조건에 부합하는 하부구조물을 개발하고, 구조 안전성을 유한요소법을 활용하여 검증하였다. 초기 설계안에서 일부 구간을 보강하여 구조 안전성을 확보하였다. 본 연구 결과를 기반으로 하여, 향후 다양한 형태의 하부구조물에 대한 구조 안전성 평가가 가능하며, 전문화된 구조 설계 및 평가 기준을 확립하였다.
Spatial structure does not have columns and walls installed inside, so they have a large space. There are upper structure and substructure supporting them. The response of seismic loads to the upper structure may be increased or decreased due to the effects of the substructure. Therefore, in this study, the seismic response of the upper structure and the floor response spectrum of the substructure were compared and analyzed according to the height of the substructure in the spatial structure where the LRB was installed. As a result, the possibility of amplification of response was confirmed as seismic waves passed though the substructure, which is likely to increase the response of the upper structures.
Large space structures exhibit different natural vibration characteristics depending on the aspect ratio of structures such as half-open angle. In addition, since the actual large space structure is mostly supported by the lower structure, it is expected that the natural vibration characteristics of the upper structure and the entire structure will vary depending on the lower structure. Therefore, in this study, the natural vibration characteristics of the dome structure are analyzed according to the natural frequency ratio by controlling the stiffness of the substructure. As the natural frequency of the substructure increases, the natural frequency of the whole structure increases similarly to the natural frequency of the upper structure. Vertical vibration modes dominate at 30° and 45°, and horizontal vibration modes dominate at 60° and 90°.
PURPOSES : This study mechanically analyzed the performance of road substructures with focus on infiltration trenches of pavement substructures. METHODS: Water contents and response times for precipitation of pavement substructures were investigated via sensors buried near the infiltration trench to measure water contents. RESULTS : The results of the water contents of pavement systems constructed with an infiltration trench yield levels that were slightly increased by approximately 2% compared to those measured from general pavement systems. This water content difference of 2% resulted in a decrease in service life of less than two years. CONCLUSIONS: Service life reduction due to an infiltration trench is minimal, particularly when the trench is installed with proper caution.
This study analyze the dynamic response property of latticed domes according to natural frequency ratio of substructure. Through eigenvalue analysis, it is was confirmed that the half-open angle 30° and 45° dominate vibration mode of the vertical direction and the half-open angle 60° and 90° dominate vibration mode of the horizontal direction. Through the dynamic response analysis, it is was confirmed that the first frequency about total structure largely appears about the vertical and the horizontal direction regardless of half-open angle.
As a preparation of a design standard regarding road facilities, such as cantilever columns for traffic lights, optimum design and risk assessment for foundation of street lights on highways are proposed. The preliminary evaluation of optimization with reliability assessment resultantly makes it possible to reduce not only the duration of construction but the cost of construction as well. Ultimate limit states and constraints functions are selected for the sliding, overturning and settlement of the foundation under external loads from super and sub-structures itself. An example foundation under the super structure of height 12m, is optimized as 30% decreased embedded depth of foundation, in which as increasing the depth of embedded connection parts, the necessary depth of foundation is deceased. However, the optimum depths and the reliability indices are sensitively dependent with earth properties and dimensions of foundation.
일반적으로 건축물의 구조해석과 설계에 있어 작업효율을 확보하기 위하여 상부구조물과 하부구조물을 별도로 모델링하여 해석 및 설계를 진행하는 분리해석 방법을 사용한다. 하지만, 상기 분리해석을 사용할 경우, 상부구조물의 고정지점과 변형된 기초구조물과는 실제 연결된 지점에서 변위차가 발생하여 구조해석의 기본요건인 변형적합성 조건을 만족하지 못하게 되고 상부구조-하부구조의 상호작용을 고려하지 못하기 때문에 실제와는 다른 구조해석 및 설계결과를 초래할 수 있다. 본 연구에서는 초고층 철골구조물을 대상으로 구조물의 부등침하 등에 큰 영향을 미치는 상재(常載)하중에 대한 분리해석과 일체해석의 해석결과 차이를 비교 분석하였다. 분석결과에 따르면 분리해석방법을 사용할 경우, 상부구조물의 구조해석에 있어 기초의 변형을 고려하지 못하기 때문에 부재력을 과소평가할 수 있고 이로인해 비안전측 설계결과를 가지고 올 수 있다. 하부 기초구조물을 분리해석으로 해석하였을 경우, 상부구조물의 강성을 고려하지 못하기 때문에 기초의 부등침하 과대평가, 부재력의 과대/과소 평가를 초래할 수 있어 비경제적이고 불안전한 설계결과를 가져올 수 있다. 특히, 기초의 변형이 상부구조물에 큰 영향을 미칠 수 있는 건축구조물, 지반의 강성이 작아서 기초에 큰 변형이 예상되는 건축물, 지반조건이 불균질하여 부등침하가 예상되는 건축구조물 등에는 분리해석을 지양해야 할 것이다.
This study investigate the dynamic response changes of rib dome structure according to property changes of Substructure. Eigenvalue analysis is conducted in first natural frequency of rib dome versus substructure and searched in the dominant mode of horizontal and vertical direction. Resonance frequency by each first natural frequency of the rib dome structure, substructure and total structure is applied for a seismic wave. That is analyzed about maximum displacement response ratio and maximum acceleration response ratio.
2009년 아이폰의 국내 출시 이후 스마트폰의 보급이 급격히 증가하여 기존에 다양한 장비로 수행되어 오던 작 업이 스마트폰으로 대체되었다. 이 과정에서 스마트폰의 작은 화면을 통하여 글자를 읽는 과제를 수행하는 비중 이 상당히 증가하였다. 본 연구에서는 일상적인 스마트폰 사용 환경에서 디스플레이 요인(화소 밀집도, 화소 하부구조, 휘도)과 환경 요인(조명 조도)이 글자를 읽을 때의 가독성 관련 불편감에 어떤 영향을 미치는지를 확인 하였다. 그 결과 지각된 가독성 관련 불편감에 영향을 미치는 것은 주로 화소 밀집도로, 화소 밀집도가 300 PPI 미만인 경우 글자를 읽는데 불편함을 느낀다는 것을 확인하였다. 조명 조도는 제한적인 영향을 보였다. 참가자들은 조명 조도가 변화 할 때 변화하지 않을 때 보다 더 큰 가독성 관련 불편감을 보고하였다. 화소 하부구조와 밝기는 가독성 관련 불편감에 영향을 미치지 않았다. 이 결과를 바탕으로 가독성을 고려할 때 다양한 크기를 가지는 스마트 기기(스마트 폰, 태블릿 컴퓨터)에서 가독성을 해치지 않는 해상도의 하한선을 제안하였다.
본 논문에서는 노심용융사고 시 관통노즐이 제거된 원자로용기 하부헤드의 구조 건전성 평가를 수행하였다. 열응력, 노심용융물의 질량 그리고 내압조건의 해석결과를 고려할 때, 하부헤드의 열응력에 의한 영향이 가장 크게 나타났다. 손상 가능성은 파손기준에 따라 평가하였으며, 등가소성변형률이 임계변형률 파손기준보다 낮은 수준으로 평가되었다. 열-구조물 연성해석 결과 하부헤드의 두께 중간층에서 항복강도보다 낮은 응력이 발생한 탄성영역 구간을 확인하였다. 내압이 커지면서 탄성영역 범위가 점차 좁아지면서 탄성영역이 내벽으로 이동하는 결과를 확인하였고, 노심용융사고 시 구조적 건전성을 만족하는 것으로 평가되었다.
본 논문은 교량 하부에서 발생된 화재에 대한 강-콘크리트 합성구조의 전반적·국부적 손상평가를 위한 수치해석적 연구이다. 수치해석의 정확성 및 효율성을 높이기 위해 구성재료의 과도 비선형 열적·열역학적 특성이 고려된 열-구조 연성병렬 화재해석 기법이 제안되고, ANSYS solver와 연결되어 해석이 수행되며, 표준화재시험과 비교·검증된다. 검증된 해석기법을 통해 국내에서 발생된 부천고가교 합성구조에 대한 화재손상해석이 수행된다. 해석결과 강박스 거더의 하부 플랜지 및 복부의 경우 임계온도를 초과하였고 구조적 처짐과 변형 형상이 화재사고 결과와 비교적 잘 일치하였다.
공간구조물은 높이-경간비 또는 개각과 같은 아치의 형상비에 따라 상이한 동적거동특성을 나타내며, 이러한 공간구조물은 지진의 영향을 직접적으로 받는 하부구조의 강성 및 그 접합부에 따라 상이한 지진응답특성을 나타낸다. 따라서 본 연구에서는 수직진동모드와 수평진동모드의 영향이 다른 단층아치구조에 하부기둥의 강성과 접합부에 따른 지진응답특성을 분석하고자 한다. 하부기둥의 영향으로 단층아치구조는 수직방향 응답이 더 많은 영향을 받으며, 기둥의 접합부 회전강성에 있어서는 활절을 제외하고는 큰 영향이 없는 것으로 나타난다.