검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 150

        81.
        2017.04 서비스 종료(열람 제한)
        Studies on the lattice girder of the cross sectional form and construction works through laboratory experiments have been performed. The numerical analysis for structural behavior such as deflection and stresses on the lattice girder, however, are insufficient. In this study the stiffness of a lattice girder was examined by using MIDAS.
        82.
        2017.04 서비스 종료(열람 제한)
        In this study, experiment using H-beam specimens was carried out and finite element analysis was conducted using the same method as the test. As a result, although experimental strength value was approximately 10% higher than analytical value, load-strain relationships from the experiment and analysis were relatively similar to each other.
        83.
        2017.04 서비스 종료(열람 제한)
        In this paper, the flexural behavior of RC member recycled heavy weight waste glass as fine aggregate was evaluated by finite element analysis. From the results, yield point and maximum load decreased with decreasing concrete strength and elastic modulus. Also, the finite element analysis program does not reflect the ductility loss of RC members using heavy weight waste glass as fine aggregate.
        84.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        This paper presents the flexural test results of steel fiber reinforced concrete (SFRC) prisms with different lengths of steel fibers. The specified compressive strength of SFRC is 40 MPa. Two types of steel fiber used in this study have lengths (0.5 and 0.9mm). Test results indicated that steel fibers with longer length is more effective to improve the flexural performance of concrete prisms than steel fibers with shorter length.
        85.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        본 논문은 폴리머 모르타르로 보수된 철근콘크리트 보의 휨거동을 실험적 ·해석적으로 분석한 결과를 제시한다. 실험적 연구에서 는 보수위치, 모르타르 재령을 실험변수로 고려하여 제작된 13개의 보에 대한 3점 휨실험이 실시되었다. 인장측 및 압축측을 보수한 실험체들 의 파괴는 모르타르와 콘크리트의 계면에서 발생하지 않았으며, 폴리머 모르타르의 인장변형률이 극한변형률을 초과하는 순간 발생하였다. 압축측을 보강한 실험체들은 기준실험체의 최대하중과 유사하였다. 그들의 연성지수는 기준실험체보다 훨씬 컸다. 인장측을 보수한 실험체 는 매우 취성적으로 파괴되었으며, 연성지수가 크게 감소하였다. 폴리머 모르타르로 보수된 철근콘크리트의 보의 휨거동을 예측하기 위해 Opensees을 사용한 재료비선형 해석을 진행하였다. 해석 모델을 단순화하기 위해 2차원 골조요소를 적용하였으며, 재료 비선형성을 고려하기 위해 파이버 모델을 적용하였다. 해석결과는 비선형 구조해석은 압축측 보수 실험체의 휨거동을 적절하게 예측하나, 인장측 휨거동는 다소 과 대 평가하는 것으로 나타났다.
        86.
        2016.11 KCI 등재 서비스 종료(열람 제한)
        이 연구에서는 고연성과 낮은 탄성계수를 갖는 PET 섬유로 보강한 철근콘크리트 보의 부착특성과 휨거동을 각각 부착실험 및 휨실 험을 통하여 규명하고자 하였다. 부착실험은 CSA S806에 따라 수행하였고, 실험변수는 섬유 종류와 보강량(CF 및 GF 시트 각 1겹, PET 시트 10겹)이었다. 총 8개의 보 실험에서 주요 실험변수는 단면의 연성비(μ = 3.4, 7.0), 보강섬유 종류(CF, GF, PET) 및 보강량이었다. 보 단면의 모 멘트-곡율 해석을 병행하였다. 부착실험의 결과, CF, GF 시트 1겹 보강에서 유효 부착길이는 각각 120, 60 mm 이었고 최대부착응력은 각각 3.25, 2.99 MPa 이었다. PET 10겹 보강에서 유효 부착길이는 60 mm, 최대 및 평균 부착응력은 각각 2.30, 2.10 MPa 이었다. 또한 최대 강도 시 CF, GF, PET의 변형율은 각각 0.36%, 0.49%, 6.29% 였으며 CF, GF 부착실험체는 계면에서 시트가 최종적으로 탈락하였지만 PET 부착 실험 체에서 박리현상은 나타나지 않았다. 휨실험의 결과, PET 10, 20, 30겹으로 보강한 RC 보의 휨강도, 휨강성이 모두 무보강 보에 비해 증가하였 고, 연성적인 휨파괴 양상을 보였으나 PET 30겹의 경우 20겹에 비하여 연성이 감소하였다. 모멘트-곡율 해석의 결과, PET 보강 보에서 접착제 의 물성을 해석에 포함시키면 해석의 정확도가 향상하였다. 한편 PET 의 내구성에 대해서는 보고된 문헌이 없어서 현재 연구 진행 중이다.
        87.
        2016.10 서비스 종료(열람 제한)
        This paper describes the effects of tensile strength and aspect ratio of steel fiber on flexural behavior of high-strength SFRC notched beam. Test results indicated that flexural properties of SFRC improved with increasing in aspect ratio and tensile strength of steel fiber.
        88.
        2016.10 서비스 종료(열람 제한)
        This study examined the flexural performance of hybrid steel beam-reinforced concrete beam systems with a relatively simple and ductile connection. Test results showed that the flexural strength of the hybrid beams can be conservatively predicted using the equivalent stress block derived in the ACI 318-14 provisions. The dowel bars arranged within the connection were effective in enhancing the ductility of the hybrid beams.
        89.
        2016.10 서비스 종료(열람 제한)
        The purpose of this paper is to evaluate the flexural strength and deflections developed of FRC beam with tensile bars composed of two layers combinations of steel bar, GFRP bar, and CFRP bar. As a test result, specimen with CFRP bars had the greatest maximum flexural strength. Specimens with FRP bars had more brittle failure behavior than only steel bars.
        90.
        2016.05 KCI 등재 서비스 종료(열람 제한)
        이 논문의 목적은 압축강도 130 MPa급의 고강도 강섬유 보강 콘크리트 보의 휨거동 특성을 파악하는데 있다. 부피비 1.0%의 강섬 유와 철근비 0.02 이하의 철근으로 보강된 고강도 강섬유 보강 콘크리트의 휨거동 특성 실험결과를 제시하였다. 일반강도철근과 고강도철근 을 실험 부재에 사용하였다. 강섬유 보강 콘크리트의 압축 및 인장거동 재료 실험과 모델링을 수행하였다. 강섬유 보강 콘크리트의 하중-균열 개구변위 실험결과를 반영하여 가상균열모델에 근거한 역해석을 통해 인장거동모델링을 제시하였다. 실험결과는 강섬유 보강 콘크리트와 고 강도철근의 사용은 균열제어 및 연성 거동에 유리한 것을 나타낸다. 일반강도철근을 사용한 보의 휨강도 실험값에 대한 수치해석에 의한 예측 값의 비는 0.81~1.42를 나타내고, 고강도철근을 사용한 보의 휨강도 실험값에 대한 수치해석에 의한 예측값의 비는 0.92~1.07을 나타낸다. 수 치해석에 의한 휨강도는 실험결과를 합리적으로 예측하고 있는 것으로 판단된다.
        91.
        2016.04 서비스 종료(열람 제한)
        This paper presents an experimental study on the improvement of ductile and flexural strength for high performance fiber reinforced cementitous composites (HPFRCC). The test was evaluated by compressive and flexural behavior of HPFRCC(compressive strength : 180 MPa) according to aspect ratio and volume contents of steel fiber. The flexural strength was increased by aspect ratio near 100 or increasing volume contents of steel fiber while there is no clearly result on the compressive strength.
        92.
        2016.04 서비스 종료(열람 제한)
        This study is to understand the structural behavior of flexural member according to the splice length of specimens reinforced by GFRP reinforcing bar. As compared with reinforcement, GFRP reinforcing bar has superior material properties such as non-corrosiveness, light weight, non-conduction, etc. However, GFRP reinforcing bar is difficult to use instead of reinforcement owing to brittle fracture when it failed. Therefore, GFRP reinforcing bar mixed with deformed reinforcing bar were used. A total of 5 specimen was produced and tested and the test main variables are the diameter of tension steel, lap splice length of GFRP reinforcing bar which are for investigating the reinforcement effects. The diameter of tension steel set as D10, and D13 and the lap splice length of GFRP reinforcing bar set as 30db, 45db and, 60db. The results of the experimental test, the specimen with GFRP reinforcing bar proved more reinforcement effect than the one without GFRP tie bar. At the same time, the specimen with tension steel of D13 increased an overall strength more than the one with tension steel of D10. The longer lap splice length showed increase the strength.
        93.
        2016.04 서비스 종료(열람 제한)
        The purpose of this study is to compare and analyze the flexural behavior characteristics of the RC(Reinforced Concrete) beam and the SIFCON(Slurry Infiltrated Concrete) beam. Three-point loading test was progressed about a RC beam and SIFCON beams of 6 according to various heights and with or without tensile reinforcement. As a result, producing structure using SIFCON can reduce weight and the use of steel reinforcement because SR300 shows higher maximum load than Control specimen.
        94.
        2015.10 서비스 종료(열람 제한)
        This paper concerns the flexural behavior of hybrid steel fiber-reinforced ultra high performance concrete (UHPC) beams. It presents experimental research results of hybrid steel fiber-reinforced UHPC with steel fiber content of 1.5% by volume and steel reinforcement ratio of less than 0.02. The comparison of moment-curvature curves of the numerical analysis results with the test results shows a resonable agreement.
        95.
        2015.10 서비스 종료(열람 제한)
        In this study, flexural behavior of recycled coarse aggregate concrete beam is described. Test variable is recycled coarse aggregate replacement ratio and reinforcement ratio.
        96.
        2015.10 서비스 종료(열람 제한)
        Bending test on the steel grid composite deck under different loading conditions are conducted for the evaluation of flexural behaviour. 1m wide two decks are connected by prefabricated joint. The Joint is composed of concrete shear key and high-tension bolts. Test results show that deck subject to concentrated centric loading has greater load bearing capacity than deck subject to eccentric loading because the deck subject to centric loading has larger effective width.
        97.
        2015.10 서비스 종료(열람 제한)
        Flexural behavior of precast concrete sandwich wall panels (PCSW) can be divided into one way or two-way according to their aspect ratio. A total of five specimens were tested to find out the effects of design direction of shear connectors and the type of insulation on flexural behavior of PCSW. Design of shear connector in two-way direction has better performance in terms of initial stiffness than those of design of shear connector in one-way direction. Also, the specimens with extruded polystyrene (XPS) foam has higher performance in terms of initial stiffness and ultimate strength than those of the specimens with for expanded polystyrene (EPS) foam.
        98.
        2015.09 KCI 등재 서비스 종료(열람 제한)
        이 연구의 목표는 학교 건물과 같은 저층 보-기둥 철근콘크리트 구조 건물에서 프리캐스트 벽패널을 사용한 새로운 내진보강 방법을 개발하는 것이다. 1개의 무 보강 보-기둥 실험체와 U형 PC 벽패널로 보강한 2개의 보강 보-기둥 실험체에 대한 정적 이력 하중실험을 진행하였다. 앵커접합 PR1-UA 실험체와 철판접합 PR1-UP 실험체는 무 보강 실험체보다 평균 2.8배(평균 591.8 kN)의 강도 증가를 보여 주었다. 최대 변위비도 1.4%에서 2.7%사이 값을 보여주었다. RC 골조 우측 상단에서 좌측방향으로 가력 할 때 우측에 있는 RC 기둥과 보강 PC 패널의 수직 요소는 완전 합성상태로 가정하였고, 좌측에 있는 RC 기둥과 PC 패널은 완전 비 합성 거동하는 것으로 가정하여 해석한 결과 전체적인 휨 거동은 실험 결과와 대체적으로 부합하는 것으로 판단되었다.
        99.
        2015.04 서비스 종료(열람 제한)
        The ultimate load of beam reinforced with polymer cement slurry(PCS)-coated rebar that is developed to replace the epoxy coated rebar having many defects is almost the same as that using plain rebar, and is higher than that of epoxy-coated rebar. In special, that using EVA 100% with ultra high early strength cement is a little bigger than that using plain rebar. In this study, it is also apparent that PCS-coated rebar can replace epoxy-coated rebar to solve the corrosion problem in marine construction field.
        100.
        2015.02 서비스 종료(열람 제한)
        단일현장타설말뚝교각은 희생강관을 지중에 매입한 후 말뚝부와 교각을 일체화된 철근콘크리트로 형성하는 구조로서 교각과 말뚝 캡의 철근배근 등 연결상세에 따른 시공상의 문제점이 발생하지 않으므로 항타 말둑과 말뚝 캡을 사용하는 일반적인 경우에 비하여 경제성이 우수하다. 그러나 말뚝과 교각의 직경이 동일한 경우 소성힌지가 지표면 이하에 형성되어 지진 작용 후 지반을 굴착하지 않고서는 소성힌지의 형성여부 및 손상 여부를 파악하기 곤란하며 보수 및 보강도 쉽지 않다. 소성힌지가 지표면 이하까지 발생하지 않도록 하기 위해서는 말뚝의 지름을 교각보다 크게 해야 하는데, 이 경우 동일한 지름의 말뚝-교각 일체형 구조에 비하여 소성힌지 길이가 상대적으로 짧아지므로 콘크리트의 피복박리가 빨리 발생하여 소성회전 능력이 감소된다고 알려져 있다. 본 연구에서는 말뚝의 직경이 교각보다 큰 변단면 단일현장타설말뚝교각의 소성힌지영역을 콘크리트 충전 강관(CFT, Concrete-Filled Tube)구조를 활용하여 보강하는 형식, 즉, 말뚝-CFT교각-RC교각을 일체화 연결하는 구조를 제안하였다. CFT형식은 RC구조에 비해 내진성능이 우수한 것으로 알려져 있으며, 일반강재 대비 내진성능을 향상시킬 수 있는 특수용 강재를 적용할 수 있는 장점이 있다. 실험 연구를 통하여 제안된 연결구조와 기존 형식의 휨 성능을 평가하였으며, 실험 결과 새롭게 제안된 형식의 연성이 우수한 것으로 나타났다.
        1 2 3 4 5