검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 57

        1.
        2024.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to propose an improvement of fire safety management plans for buildings, such as apartment complexes and schools, within a 10 km radius of industrial complexes. It utilizes an off-site consequence analysis program to reflect the toxic impact on national industrial complexes and surrounding areas. The ALOHA program was utilized to analyze the impact of toxicity due to a hydrogen chloride leak, a hazardous material. The results showed that the area with AEGL-2 and above ranged from 3.1 km to 10 km, the AEGL-3 area ranged from 1.9 km to 7.3 km. The ASET was measured to be between 3 and 24 minutes. Due to the impact of toxicity, it is necessary to prepare fire safety management plans for buildings, such as apartment complexes and schools that are within a 10 km radius from industrial complexes. These safety plans incorporate the hydrogen chloride risk assessment results, ASET, weather conditions, and coordination with the local community.
        4,200원
        2.
        2024.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        STCW 협약 A-VI에 의거, 승선 필수 증서를 발급받기 위해 소화 과정 최저 훈련 이수를 거치게 되는 공간이 수소화 훈련장 이다. 선박 화재의 상황과 유사한 장소에서 발생한 화재 진압 훈련을 위한 실습 장소의 특성상, 재실자의 안전을 보장할 수 있는 운영 을 위해 안전성을 수치화하여 평가하고 기준을 수립하는 연구의 필요성이 대두되었다. 화재 안전 평가를 위해 FDS를 기반으로 한 Pyrosim을 활용하여 제연설비 유무에 따른 Case를 설정, vector의 분석을 통한 연기 유동 및 열기에 대한 평가를 수행하였다. 피난 안전 평가는 Pathfinder를 통해 허용 피난시간, 총 피난시간을 수치화된 결과로 해석, 비교하여 안전성을 분석하였다. 각 Case에 대한 안전성 을 평가함으로 제연설비별 기능의 적정성을 수치, 시각적으로 나타내었으며, 현재 운영 상태는 안전성이 양호한 것으로 평가하였다. 집 진설비가 정지한 비상상황은 각 피난시간과 111.2초의 여유시간으로 나타내어 수소화 훈련장의 비상상황에 대한 피난시간의 기준으로 활용할 것을 제시하였다.
        4,000원
        3.
        2024.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 원자력 지진 PSA(Probabilistic Safety Assessment)를 토대로 산업시설물의 지진 PSA를 수행하는 연구가 진행되었다. 해당 연 구는 원자력 발전소와 산업시설물의 차이를 파악하고, 최종적으로 운영정지를 목표로 하는 고장수목(Fault Tree)를 구축한 후 시각적 확률도구인 베이지안 네트워크(Bayesian Network, BN)으로 변환하였다. 본 연구는 선행연구를 기반으로 지진으로 유발된 구조손상 으로 인해 발생 가능한 화재・폭발에 대해 PSA를 수행하고자 하였다. 이를 위해 화재・폭발을 사건수목(Event Tree)으로 표현하고, BN 으로 변환하였다. 변환된 BN은 화재・폭발 모듈로서 선행연구에서 제시된 고장수목 기반 BN과 연계되어 최종적으로 지진 유발 화재・ 폭발 PSA를 수행할 수 있는 BN 기반 방법론이 개발되었다. 개발된 BN을 검증하기위해 수치예제로서 가상의 가스플랜트 Plot Plan을 생성하였고, 가스플랜트의 설비 종류가 구체적으로 반영된 대규모 BN을 구축하였다. 해당 BN을 이용하여 지진 규모에 따른 전체시 스템의 운영정지 확률 및 하위시스템들의 고장확률 산정과 더불어 역으로 전체시스템이 운영 정지되었을 때 하위시스템들의 영향도 분석과 화재・폭발 가능성을 산정하여 다양한 의사결정을 수행할 수 있음을 제시함으로써 그 우수성을 확인하였다.
        4,300원
        4.
        2024.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As the distribution of vehicles and logistics increases due to the development of human civilization and the increase in population, various roads play an important role in domestic traffic and transportation. However, the recent emergence of large cities and new cities is causing traffic problems, and the increase in roads is inevitable for the smooth distribution of vehicles and logistics. In Korea, mountainous regions occupy 70% of the country, so tunnels are used to open roads. Without this, it is difficult to open the road. Currently, there are 3,720tunnels (as of December 31, 2023) installed on high-speed national highways, general national highways, and local roads nationwide, with a length of 2.499 and increasing every year. Accordingly, fire accidents in tunnels will also increase, and due to the nature of tunnel fire accidents, there is a high probability that they will escalate into large-scale disasters, resulting in casualties and property damage, as well as significant social losses due to the disruption of logistics transportation, etc. As the possibility of potential hazards is increasing, the purpose of this study is to build a safe and efficient tunnel system by optimizing maintenance and management for fire and disaster accidents in tunnels.
        4,000원
        5.
        2024.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : Carbon dioxide (CO2) is a cheaper and easier to installer fire suppressant than other extinguishing gases and is easy to install, but extinguishes fires by is suffocation. As a result, suffocation accidents continue to occur in facilities equipped with CO2 fire-extinguishing facilities, Emission standards have yet to be established. This study aims to address the issue. METHODS : To effectively remove CO2 emitted from installed systems, we reviewed and analyzed previous related research and existing international standards. RESULTS : In protected areas where CO2 fire-extinguishing systems are installed, emission facilities should discharge the emitted CO2 before it enters the protected spaces. CO2 sensors can determine whether safe entry is possible or whether respirators are required. CONCLUSIONS : This study presented a specific installation method for emission facilities capable of actively discharging CO2. Applying this method is expected to contribute to improving safety in facilities equipped with CO2 fire-extinguishing facilities.
        4,000원
        6.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to verify the impact of a metaverse-based safety education program on the fire safety awareness of elementary school students. Utilizing the National Fire Agency's 119 metaverse program, an educational program was implemented for two months, and the experimental group was examined using paired-sample t-tests, while comparisons with the control group were made using independent-sample t-tests. The results revealed statistically significant differences between the experimental and control groups in the area of fire prevention. Although no statistically significant differences were observed over time within each group, the overall average scores for the entire class improved across all areas. Based on these findings, the effectiveness of metaverse-based safety education is suggested; however, a significant difference compared to traditional education was not detected. The study concludes by exploring implications for considerations in the implementation of metaverse safety education in the future.
        4,000원
        8.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study attempted to analyze the comparative advantage in terms of disaster safety costs in verifying the effectiveness and economic feasibility of the high-performance water-bulwark system in the pole tunnel, which was recently promoted as a part of the acceleration of vehicles. The tunnel to be analyzed was divided into a short tunnel(Anyang, Cheonggye) and a long tunnel(Suraksan, Sapaesan). As a result, it was analyzed that 25% of the improvement effect would occur if one lane was secured by applying the Water-Bulwark System. It was analyzed that this is because the time value cost, which accounts for a large proportion of the traffic congestion cost of short tunnels and pole tunnels, differs depending on the congestion time and traffic volume, not the length of the tunnel.
        4,000원
        10.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In school safety education, it was difficult to apply how to link the safety education according to grades year, and student’s interest was reduced due to the repetition of existing safety education contents and the absence of new teaching methods and tools. In this study, as a new type of safety education, a performance forms fire safety education program was developed. This program aims to increase students’ interest and satisfaction in safety education, and to this end, it was connect with korean elementary science curriculum and combined various engineering teaching materials or tools and methods. Developed program was applied to 2,231 students, 25 schools in 10 regions of Gyeonggi-do and surveyed 476 fifth and sixth grade students program satisfaction and 3 factors of interest in fire safety education who could respond to the survey. As a result of applying the program, more than 90% of students responded more than 'satisfied' in all areas. and statistical test(independent t-test and non-parametric test) indicates over-all satisfaction and interest factors in the program are high regardless of gender and grade, so the effectiveness can be guessed indirectly and there is a universal applicability also. Moreover, examining the influence of student interest level in the satisfaction of the fire safety program, it was found that in order to increase the satisfaction of fire safety education, students should have more fun with the content and feel interest in the teacher's teaching method or explanation.
        4,000원
        11.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study attempted to explore how the perception of the necessity of safety education for adolescents affects fire safety consciousness and whether personality factors control the relationship. To this end, a survey was conducted at a high school in region C, and data of 1,049 people who agreed to the survey and responded faithfully were used for analysis. Hayes’ macro was used to analyze the moderating effect, and as a result of the analysis, adolescents’ awareness of the need for safety education increased, and their relationship was significantly regulated by extroversion, openness, and conscientiousness among the five personality factors. A simple regression line analysis was conducted to find out the specific direction, and it was found that the higher the need for safety education in both the group with high extroversion, openness, and conscientiousness, the higher the awareness of safety education. These results suggest that changes in educational methods and contents are needed to raise awareness of the necessity of education in fire safety education and to improve educational motivation, and that it may be helpful to actively utilize students’ personality strengths in education.
        4,000원
        13.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, fire and evacuation safety of environmental energy facilities using fire and evacuation simulation was examined as part of performance-oriented design. The worst-case fire scenarios in which fire-fighting facilities such as sprinkler fire extinguishing and smoke control systems are not working, and the FDS analyzes the visibility, temperature distribution, and carbon monoxide concentration distribution through FDS. The safety was examined. As a result, it was proved that evacuation could limit the visibility, temperature, and carbon monoxide concentration in a smooth range, based on the safety standards set by relevant laws. In other words, it was possible to verify the safety of fire and evacuation for environmental energy facilities where a large amount of combustibles and fires coexist.
        4,000원
        15.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper describes result of a study on safety against a fire of charging cable for mobile phone for vehicle. Combustion on the USB cable in the car was happened while driving. Gas coming from the burning USB cable could be a reason which can make a secondary car accident since the driver also can be embarrassed while driving. In order to prevent a secondary car accident connected on the road, to research a reason why USB cable can emit gas and be burned in charging. We did simulation test with abnormal fault condition for the electronic component on the board in the USB cable. So we get the result from abnormal fault condition simulation test, for instance, shorted test for output terminal of 8 pin switch, shorted test for chip resistor after thermal aging in the condition 25 ℃ , 93 % RH during 48 hours. To analysis the result of all test, Combustion on the USB cable was not the 8 pin but other electrical component such as a chip resistor. Therefore we guess that the reason for USB cable combustion in charging in a car was not 8 pin and a LED but another defective component.
        4,000원
        16.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Currently many geriatric hospitals have been built in Korea because younger people don’t want to care their parents and have been decreasing for labor. However, the increasing geriatric hospitals make the increasing fire safety accidents. Therefore, this study is conducted by survey and face-to-face talk for analyzing fire safety problem of twelve among 15 geriatric hospitals in the north of Chung-Buk area. The result of this study is that infection and fall accident are higher than others and fire safety implement rate of safety rule followed by CEO is 71%. Monthly safety training rate is 49% and initial fire safety training not conducted is 33%. Yearly outside fire safety training rate is 97% but workers who know how to use fire evacuation facility are 61%. Furthermore, safety instruction rate of fire safety manager is much higher than supervisor’s safety instruction. The cause of accident is facility (33%). In conclusion, the institution and rule improvement need for decreasing infection and falling, increasing implement level of fire safety rule and fire safety training, participation rate of supervisor for fire safety, quality of fire safety training, and investment of fire safety facility.
        4,000원
        17.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Because National Fire Safety Codes is mixed performance criteria and specification, and it defines the fire extinguish equipment type and standards that need to be installed in a building as one method. Therefore, to fully reflect the fire risk characteristics of the building, such as the wooden building there is a limit. In this study, suggested to the performance criteria drawn methodologies through fire load of wooden buildings studies, theory on performance and performance analysis to fire extinguish equipment of the wooden buildings is installed according to current fire safety codes.
        4,000원
        18.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Currently many geriatric hospitals have been built in Korea because increasing aging rapidly. However the increasing geriatric hospitals make the increasing safety accidents. Therefore this study is conducted by survey and face-to-face talk with the fire safety managers for analyzing safety problem of geriatric hospitals which number is twelve among 15 geriatric hospitals in the north of Chung-buk area. The result of this study is that geriatric hospitals are very old. Fire safety managers holding the fire safety license are a level 2 issued by the Korea Fire Safety Association(KFSA). And the fire safety inspection ability of them is normal (58%). Furthermore a fire safety budget ratio is 83% (A little) in the company yearly budget. And ratio having the fire inspection equipment in the building is 42% (A little) and 33% (Nothing). Satisfaction ratio of their duty is 66% and they also get stress from heavy duty and heavy responsibility. In conclusion, CEO needs to invest and interest the improvement of job performance, satisfaction ratio and fire safety facility. Also government needs the improvement of system to support and supervise the fire safety of geriatric hospitals consistently.
        4,000원
        19.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The leisure life pattern of people is changing to a familial and enthusiastic way that eventually develops the camping culture. Thus, the number of campers and the size of camping market have been dramatically increased due to significant expansion of camping people. However, many camp grounds and facilities are operating without a proper registration by government rules and regulations. In addition, many of electronic and gas equipment and tools are not used in a safe way and in a safety regulatory boundary. Therefore, campers at the camping ground is situated in a fire and safety hazard. In addition, there is limitation in rules and regulations associated with camping ground safety and fire. This study analyzed the fire and hazard guidelines and rules regulations of developed countries of campground and compared them to the current situation in South Korea. Therefore, this study is to develop a safety and fire hazard guidelines and rules and regulations related to camp ground operation, gas and electronic equipment operation and management. The study will eventually reduce the future fire and safety incidents in a campground in South Korea.
        4,000원
        1 2 3