        검색결과 31

        2.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the present study, the experimental study was conducted using a multi-calorie meter, to investigate the cooling performance and cycle operation changes of the multi-heat pump (3 indoor units) for the low outside temperature in summer. The test temperature condition was the low cooling temperature, and the normal performance and dynamic behavior of 3 rooms, 2 rooms, and 1 room were measured to understand the operating characteristics of seven 7 indoor unit combinations. As a result of the experiment, the cooling capacity and COP of the multi-heat pump at low cooling temperature were about 10% and 6% higher than those of the cooling standard temperature. In addition, the dynamic behavior of the indoor units of 3 and 2 rooms was observed differently due to the load difference according to the indoor unit combinations and the non-uniformity of the refrigerant amount. And, when starting the heat pump, the compressor had a maximum peak value and stabilized by repeating the decrease and increase for each indoor unit combination.
        4,000원
        3.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Diesel engine has the advantages of strong power, low fuel consumption and good durability, so it has been widely used in transportation, automobile, ship and other fields. However, the nitrogen oxides(NOx) and particulate matter(PM) emitted by diesel engines have become one of the main causes of air pollution. Especially during idling, the engine temperature is low, and there are more residual exhaust gases in the combustion chamber, resulting in the formation of more harmful emissions. In this study, performance of a single cylinder, four-stroke, direct injection (DI) diesel engine fueled with diesel–biodiesel mixtures has been experimentally investigated. The findings show that a remarkable improvement in PM–NOx trade-off can be achieved by burning diesel-bioethanol blend fuels.
        4,000원
        4.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to experimentally investigate the operation characteristics of the multi-heat pump with 3 indoor units, the dynamic characteristics of the cooling cycle is studied using the psychrometric multi-calorimeter. The compressor of the heat pump is the scroll inverter type, and since 3 indoor units operate cooling at the same time, it is operated at 100% full load. In particular, 3 types of indoor unit temperatures (20, 24, 26°C) are selected to understand the operation process of the multi-heat pump by the setting temperature. From this experiment, the compressor controls the EEV opening for each indoor unit while varying the frequency according to the initial start, transient, and steady operation. In addition, as the setting temperature increases in the steady range, the frequency of the compressor and the average opening degree of the EEV decrease.
        4,000원
        6.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, blending oils of diesel oil and butanol were used as fuel oil for diesel engine to measure combustion pressure, fuel consumption, air ratio and exhaust gas emission due to various operating conditions such as engine revolution and torque. Using these data, the results of analyzing the engine performance, combustion characteristics and exhaust emission characteristics such as NOx (nitrogen oxides), CO2 (carbon dioxide), CO (carbon monoxide) and soot were as follows. The fuel conversion efficiency at each load was highest when driven in the engine revolution determined by a fixed pitch propeller law. Except 30% butanol blending oil, fuel conversion efficiency of the other fuel oils increased as the load increased. Compared to diesel oil, using 10% and 20% butanol blending oil as fuel oil was advantageous in terms of thermal efficiency, but it did not have a significant impact on the reduction of exhaust gas emissions. On the other hand, future research is needed on the results of the 20% butanol blending oil showing lower or similar levels of smoke concentration and carbon monoxide emission rate other than those types of diesel oil.
        4,000원
        8.
        2021.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Eutrophication and algal blooms can lead to increase of taste and odor compounds and health problems by cyanobacterial toxins. To cope with these eco-social issues, Ministry of Environment in Korea has been reinforcing the effluent standards of wastewater treatment facilities. As a result, various advanced phosphorus removal processes have been adopted in each wastewater treatment plant nation-widely. However, a lot of existing advanced wastewater treatment processes have been facing the problems of expensive cost in operation and excessive sludge production caused by high dosage of coagulant. In this study, the sedimentation and dissolved air flotation (SeDAF) process integrated with sedimentation and flotation has been developed for enhanced phosphorus removal in wastewater treatment facilities. Design and operating parameters of the SeDAF process with the capacity of 100 m3/d were determined, and a demonstration plant has been installed and operated at I wastewater treatment facility (located in Gyeonggi-do) for the verification of field applicability. Several empirical evaluations for the SeDAF process were performed at demonstration-plant scale, and the results showed clearly that T-P and turbidity values of treated water were to satisfy the highest effluent standards below 0.2 mg/L and 2.0 NTU stably for all of operation cases.
        4,600원
        10.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Desalination plants are generally studied with higher operating costs compared to water supply facilities. This study was conducted to reduce the cost of water production and to preserve existing water resources. Therefore, the purpose of this study was to utilize the control valves to increase maximum efficiency, thereby reducing the power of the pumps and operating costs. Specific energy consumption was shown to reduce the process operating power by up to 1.7 times from 6.17 to 3.55 kWh/m3 based on seawater reverse osmosis 60 bar. In addition, the water intake process was divided into pre, inter, and post-according to the use method of blasting, and the water treatment process was divided into pre, inter, and post blending. In order to reduce power consumption, the blending process was combined to operate the facility, which resulted in the reduction of power consumption in the order post > pre-inter> inter blending.
        4,000원
        11.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the performances of the refrigeration unit for the box under actual operating conditions were examined by using the constant temperature and humidity chamber (air enthalpy method). For this purpose, the degree of superheat, pressure, and temperature were measured while changing the EEV opening, the compressor speed, the outdoor temperature, and the load in the refrigeration cycle of the refrigeration unit. The highest cooling performance was found at EEV 33%. However, EEV 35% with low compression ratio and degree of superheat was the most reliable in terms of reliability. Considering the compressor speed and cooling performance, the refrigeration unit was in an optimal condition at the compressor speed 3,040RPM. The results of this study will be provided as basic data for the optimal design of refrigeration units for box.
        4,000원
        12.
        2019.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to the concern on global warming, refrigerants having high GWP(Global Warming Potential) are being replaced to low GWP refrigerants. As for small slush maker, R-134a is being to replaced to R-290, whose GWP is 3. In this study, performance tests were conducted on the slush maker having dual evaporator, which was designed to operate using R-290. Results showed that the optimum refrigerant charge amount was 100g. At the charge amount, 61 minutes was needed to make a slush from a raw milk substance, which contained 10% sucrose. The power consumption was 0.89 kW, which yielded COP of 0.252. Tests were further conducted changing the outdoor air temperature. It was resulted that slush-making was possible at all outdoor temperatures except at an extreme temperature of 43°C. Even at the temperature, slush-making was possible if the machine operated with a single evaporator. The COP increased with the decrease of the outdoor temperature.
        4,000원
        13.
        2018.11 구독 인증기관·개인회원 무료
        본 실험에서는 조류 제거 및 농축을 위해 Silicon Carbide(SiC) 재질의 침지형 세라믹막을 적용하여 운전 특성을 평가하고자 하였다. SiC 세라믹막은 막표면이 음전하를 띄어 음전하를 띄는 조류 제거에 적용이 가능하고 고유량으로 역세척(Backwashing)을 할 수 있어 고농도의 조류 농축시에도 적용이 가능하다. 역세척 유량과 역세척 시간, 역세척수 수온, 역세척수에 차아염소산나트륨 주입 유무, 여과/역세시 air scrubbing 유량에 따라 역세척 효율을 평가하였으며 Jar test를 통해 선정한 농도로 응집제 주입 유무에 따라 운전 특성을 비교하였다. 또한 동일한 조건에서 세라믹막과 유기막의 운전 특성과 비교하였다. 본 연구는 환경부의 “환경정책기반공공기술개발사업”으로 지원받은 과제입니다.
        14.
        2018.11 구독 인증기관·개인회원 무료
        본 연구는 비용매 상분리법(nonsolvent induced phase separation, NIPS)을 사용하여 제조한 분리막의 배출수 처리 현장 적용성 test를 위한 최적 유효막 길이 선정 하기 위해, 동일한 원수, 기본 공정 조건으로 유효막 길이를 변화시켜 운전에 따른 역세 효율 및 운전압을 관찰하였다. 동일한 공정조건에서 유효막 길이의 변화를 주어 500㎜, 1,000㎜, 1,500㎜의 유효막 길이에 따라 1.5일간 고탁도의 가혹한 조건에서 공정을 지속하여 측정을 실시하였다. 유효막 길이별 운전 결과 유효막 길이에 따른 역세에 의한 효율차이를 확인할 수 있었으며 고탁도의 원수를 사용하여 중공사 막의 내부 폐색이 진행되었으며 유효막 길이가 길수록 폐색되지 않은 bore쪽으로만 역세가 진행되어 여과 후 역세에 의한 회복이 현저히 떨어짐을 확인하였다.
        15.
        2018.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The purpose of this research is to analyze the characteristics of panels that affect the evaluating results of riding quality and to evaluate the appropriateness of roughness management criteria based on ride comfort satisfaction. METHODS: In order to analyze the influence of panel characteristics of riding quality, 33 panels, consisting of civilians and experts, were selected. Also, considering the roughness distribution of the expressway, 35 sections with MRI ranging from 1.17 m/km to 4.65 m/km were selected. Each panel boarded a passenger car and evaluated the riding quality with grades from 0 to 10, and assessed whether it was satisfied or not. After removing outlier results using a box plot technique, 964 results were analyzed. An ANOVA was conducted to evaluate the effects of panel expertise, age, driving experience, vehicle ownership, and gender on the evaluation results. In addition, by using the receiver operating characteristics (ROC) curve, the MRI value, which can most accurately evaluate the satisfaction with riding quality, was derived. Then, the compatibility of MRI was evaluated using AUC as a criterion to assess whether the riding quality was satisfactory. RESULTS: Only the age of the panel participants were found to have an effect on the riding quality satisfaction. It was found that satisfaction with riding quality and MRI are strongly correlated. The satisfaction rate of roughness management criteria on new (MRI 1.6 m/km) and maintenance (MRI 3.0 m/km) expressways were 95% and 53%, respectively. As a result of evaluating the roughness management criteria by using the ROC curve, it was found that the accuracy of satisfaction was the highest at MRI 3.1-3.2 m/km. In addition, the AUC of the MRI was about 0.8, indicating that the MRI was an appropriate index for evaluating the riding quality satisfaction. CONCLUSIONS: Based on the results, the distribution of the panels’age should be considered when panel rating is conducted. From the results of the ROC curve, MRI of 3.0 m/km, which is a criterion of roughness management on maintenance expressways, is considered as appropriate.
        4,000원
        16.
        2018.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study conducted an empirical analysis of the effects of job characteristics on work-family conflict relation and quality of life, as well as moderating effects in accordance with operation type, by targeting 245 dietitian/cooks working for contract foodservice companies. The results of this study are as follows. First, the autonomy and feedback had negative (−) effects on work-family conflict while functional diversity had positive (+) effects on work-family conflict. Job identity and job importance had no relation with work-family conflict. Second, work-family conflict had negative (−) effects on job satisfaction, work-family relation, job support, general happiness, and job environment while having positive (+) effects on job stress. Third, in all paths except for the path with effects of work-family conflict on job stress, there were no differences between the group of shops operating 365 days and the group of shops operating 5 days a week. It would be helpful to the effective operation of human resources by emphasizing the necessity of differentiated management for companies with shops operating 365 days and shops operating 5 days a week, as well as managing employees’ job characteristic factors, work-family conflict, and even quality of life.
        4,000원
        17.
        2015.11 구독 인증기관·개인회원 무료
        MBR 공법의 처리수 중의 총인을 흡착하는 탈인장치를 50m³/일 규모로 운영하였다. 탈인장치는 Ф1m x 2.5mH(2mEH)로 원통형 구조이며, 내부에 모래 및 흡착제가 0.7m³ 및 0.3m³ 충진되었다. MBR 처리수는 탈인장치 하부에서 상부로 이동하면서 총인이 흡착되고, 모래와 흡착제는 중심부의 원형관을 통하여 상부로 이송되고, 재생용액인 ClO2/Ca(OH)2에 의하여 재생된 후 상부로 재 보충된다. MBR 처리수의 총인은 1.0~1.8mg/L였으며, 탈인 장치 처리수 중의 총인은 0.4~0.8mg/L로 나타났다. 흡착제 재생시 발생한 세척수는 약 4% 이내로 운영되었다.
        18.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study is to investigate the effect of operating conditions on the performance of small HSDI compression ignition engine. Combustion and exhaust emission characteristics of engine were studied by using CFD simulation with ECFM-3Z combustion model. The conditions of simulation were varied with injection timing, injection pressure, and operating speed, and the results were compared in terms of combustion pressure, rate of heat release, NOx and soot. It was found that as injection timing was advanced and injection pressure is increased, combustion pressure and rate of heat release were increased. As a result, NOx generation is increased. Soot generation is also increased due to the wall film caused by the increase of the injection pressure and locally the rich mixture caused by the effect of the advancing of injection timing.
        4,000원
        20.
        2015.03 구독 인증기관 무료, 개인회원 유료
        The heating & cooling performance of vapor compression heat pump using seawater heat source has been investigated experimentally for fish farm heat supply system. The principal parts of the heat pump systems are compressor, condenser, expansion devices and evaporator. The evaporator and condenser are both heat transfer devices. We used double pipe H/E(CASE-1) and shell&coil H/E(CASE-2) as evaporator, condenser of heat pumps. The experimental results were higher Uvalue 25% of double pipe heat exchanger compared to shell & coil H/E. The COPc is 4.74 and the COPH is 6.18 of the heat pump with shell & coil H/E.