        1.
        2023.11 구독 인증기관·개인회원 무료
        The radwaste repository consists of a multi-barrier, including natural and engineered barriers. The repository’s long-term safety is ensured by using the isolation and delay functions of the multi-barrier. Among them, natural barriers are difficult to artificially improve and have a long time scale. Therefore, in order to evaluate its performance, site characteristics should be investigated for a sufficient period using various analytical methods. Natural barriers are classified into lithological and structural characteristics and investigated. Structural factors such as fractures, faults, and joints are very important in a natural barrier because they can serve as a flow path for groundwater in performance evaluation. Considering the condition that the radioactive waste repository should be located in the deep part, the drill core is an important subject that can identify deep geological properties that could not be confirmed near the surface. However, in many previous studies, a unified method has not been used to define the boundaries of structural factors. Therefore, it is necessary to derive a method suitable for site characteristics by applying and comparing the boundary definition criteria of various structural factors to boreholes. This study utilized the 1,000 m deep AH-3 and DB-2 boreholes and the 500 m deep AH-1 and YS- 1 boreholes drilled around the KURT (KAERI Underground Research Tunnel) site. Methods applied to define the brittle structure boundary include comparing background levels of fracture and fracture density, excluding sections outside the zone of influence of deformation, and confining the zone to areas of concentrated deformation. All of these methods are analyzed along scanlines from the brittle structure. Deriving a site-specific method will contribute to reducing the uncertainties that may arise when analyzing the long-term evolution of brittle structures within natural barriers.
        2.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the early of Joseon Dynasty, Royal Tomb developed from stone chamber tomb to lime chamber tomb through precedents. The lime chamber tomb consists of main-chamber(JeongGwang) and sub-chamber(ToeGwang). This separation makes character to construct tumulus of the Royal Tomb half and half. By this character, the Royal Tomb are not constructed by separate structure but constructed by coadjustment. The underground structure and tumulus of the Royal Tomb affect each other in the size and method of construction. The selecting type of Royal Tomb is generally made decision through terrain and politics. This study prove the architectural structure is also one of the major cause the that select type of Royal Tomb.
        4,300원
        3.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        일반적으로 지중구조물은 지상구조물보다 지진하중 작용 시 상대적으로 작은 영향을 받는다. 그러나 많은 연구자들은 심각한 지중구조물 손상에 대해 보고하고 있으며 동적 흙-구조물 상호작용에 대한 지속적인 연구를 수행하고 있다. 본 연구에서는 유한요소해석 프로그램을 활용한 흙-구조물 상호작용을 지중구조물에 적용하고 지중구조물 하중저감기법인 ETI의 지오폼을 해석변수로 경감효과 및 최적 지오폼을 제안하고자 한다. 해석연구에 고려된 지오폼은 EPS 12, EPS 15, EPS 19이다. 해석 결과로부터 지진하중시 최대 50%까지 지중하중이 경감되었으며, 수평처짐은 26%, 수직처짐은 8%이 경감되었다. 본 해석연구를 토대로 ETI 공법을 적용한 지중구조물이 정적 및 지진하중 하에서도 하중의 영향을 경감시키는 것을 확인할 수 있었다.
        4,000원
        4.
        2018.04 구독 인증기관·개인회원 무료
        In order to solve the limitation of the long span arch structures, a numerical analysis was carried out to investigate the effects of embedded trench installation technique to the earth pressure of an underground arch-rib shaped structure. For the arch-rib shape, the parabolic curve and the circular shape were analyzed according to the span-rise ratio varying from 0.1 to 0.5. The finite element analysis program, ABAQUS (2016), was used to consider the soil - structure interaction. The results from the analysis was verified through comparison with the existing Geofoam application technique.
        6.
        2007.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 1편에서 얻어진 온도분포와 박리시간이력을 이용하여 지하박스구조물의 열응력을 산정하고 이에 기반한 열모멘트를 산청하였다. 또한 이때의 온도분포를 바탕으로 구조물의 열적비선형성을 고려한 극한모멘트를 산정하여 구조물의 내하력을 산정하였다. 그 결과 상부슬래브의 부모멘트 구간은 단면의 온도경사에 의해서 발생하는 열모멘트에 의해 지배받는 것으로 나타났다. 반면 정모멘트 구간은 박리에 의해 화염에 노출된 철근의 항복응력에 의해 지배받는 것으로 나타났다.
        4,000원
        7.
        2007.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 전력구나 공동구와 같은 지하 콘크리트박스구조물의 화재발생시 온도분포와 박리거동에 대한 수치해석을 수행하였다. 해석에 사용된 온도장은 터널화재에 사용하는 화재곡선을 기본으로 하고 화재시 내부공간에 대한 열유체해석을 수행하여 온도분포를 결정하였다. 박리거동은 탈수화도를 따라 콘크리트의 온도가 기준값에 도달하였을때 발생하는 것으로 하였다. 이때 박리가 일어난 요소를 제거하고 경계조건과 요소망을 재생성하여 해석을 반복수행하였다. 3개의 화재 시나리오에 따라 해석을 수행하였고, 해석결과는 각 시나리오별로 타당한 박리거동을 보여주었다. 각 시나리오에 따른 구조물의 내하력은 본 논문의 2편에서 산정되었다.
        4,000원
        8.
        2002.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 다단계방법(multi-step method)을 사용하여, 지진시 지반과 지하구조물 경계가 가장 미끄러지기 쉬운 상태일 수 있는 지반 공진시에 대하여 지하구조물 축방향 동지반강성계수와 미끄러지기 쉬운 조건들을 구하였다. 상재하중에 의한 지반과 지하구조물 경계에서의 전단저항력과 지진시 발생되는 미끄러짐 부분의 전단력을 비교함으로써 미끄러짐 조건을 결정하였다. 그리고 매개변수 해석을 통하여 지하구조물의 크기와 위치, 지반조건, 표층지반의 형상 및 경계마찰계수에 대하여 미끄러지기 쉬운 조건을 구하였다.
        4,000원
        9.
        1997.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 지하암반구조물의 구조해석시 불연속암반체의 물성변이를 고려할 수 있는 확률론적해석기범을 개발하였다. 수치해석적 접근은 몬테칼로모사기법의 단점을 보완한 LHS기법을 사용하였고, 불연속변의 영향은 단층,벽개 등과 같이 불연속성이 뚜렷한 지역에서 적용성이 높은 절리유한요소모델을 사용하였다. 재료특성에 대한 확률변수는 불연속변의 수직강성과 전단상성을 다확률변수로 사용하였으며, 이들은 확률공간에 정규분포를 갖는 경우에 대하여 고려하였다. 본 연구에서 개발된 수치해석프로그램은 검증예제를 통하여 타당성을 확인하였으며, 가상의 불연속면군의 존재하는 지하원형공동에 대한 해석을 통하여 프로그램의 적용성을 확인하였다.
        4,300원
        10.
        2017.04 서비스 종료(열람 제한)
        There are many cases where large areas of the underground parking lots of residential buildings do not have proper measures against prevention of leakage, resulting in condensation, growth of infectious microogranisms and increase of pollution in the air. This paper discusses a study conducted to understand the awareness of leakage problems and the damage that follows in the underground structures of residential buildings.
        11.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        There are many cases where large areas of the underground parking lots of residential buildings do not have proper measures against prevention of leakage, resulting in condensation, growth of infectious microogranisms and increase of pollution in the air. This paper discusses a study conducted to understand the awareness of leakage problems and the damage that follows in the underground structures of residential buildings.
        12.
        2016.10 서비스 종료(열람 제한)
        By amending of the special law on the safety management of the facility, underground structure have been incorporated into kinds of facilities. In this paper, an inspection manual for the underground structure will be introduced.
        13.
        2016.01 KCI 등재 서비스 종료(열람 제한)
        현재 대형 빌딩이나 공동주택에 건설되는 지하구조물은 건조수축, 시공이음, 폼타이부 등에서 콘크리트 균열로 인한 누수가 많이 발생되고 있다. 누수가 발생하게 되면 구조물의 지하공간은 결로, 곰팡이 등이 발생되어 지하 환경을 악화시키고 구조물의 콘크리트로 흡수되 면 철근의 부식 등을 유발하여 구조물의 안전을 위협한다. 이는 지하구조물의 사용과정에서 장기적인 쾌적성과 구조물에 안전성이 고려되지 않은 설계와 시공의 결과이며 누수 하자에 대하여 유도배수처리로 대응하기 때문에 근본적인 누수보수가 이루어지지 않아 지하구조물은 항시 누수를 허용하고 있는 실정이다. 따라서 본 연구에서는 지하에 적용되는 방수공법을 내방수와 외방수로 분류하고 이를 바탕으로 지하구조물 과 유사한 간이시험체를 제작하였으며, 결로가 많이 발생되는 동절기의 온도조건을 기준으로 지하환경의 방수공법별 습도변화량을 분석할 것 이다.
        14.
        2014.10 서비스 종료(열람 제한)
        With the recent increased awareness of underground water as a resource and detection of radioactive material called radon in underground, underground waterproofing system is newly regard as not only ensuring stability and durability of the structure but also preserving underground water, safety of employee working underground structure, protecting of facilities and comfortable use. For these reasons, constructing industry have highly demanded feasible underground waterproofing system that responding long-life and high-performance new material and developing waterproof performance evaluation techniques. Therefore, this study attempts to build environmental responding waterproof system with high adhesive sealant material and setting a manual of field application in waterproofing construction technique.
        15.
        2014.10 서비스 종료(열람 제한)
        Scanning technic is implemented with the underground structures: subway, tunnel, shaft, drainage path, spillway, and slurry wall. Both optical and laser scanning system have been conducted to the precise inspection of diagnosis and safety. Image and 3D coordinate from scanning can be utilized in monitoring scope and fundamental database of maintenance. There is a high possibility that the scanning will prevail on inspection and diagnosis.
        16.
        2014.05 KCI 등재 서비스 종료(열람 제한)
        서울지역 28개 지하구조물에 대한 정밀안전진단 결과를 활용하여 제안된 균열집중구간 및 탄산화 기반 한계상태함수를 산정하여 우선적인 보수구간을 선별하고자 하였다. 상태평가를 위해 분할된 503개 쉬트에 대한 균열밀도는 로그정규분포, 탄산화 및 피복은 정규분포의 현장조사 결과를 얻었다. 각 구간별 실시한 강도, 초음파속도, CO2농도, 철근부식도, 염화물함유량 등을 고려할 수 있도록 환경지수를 도입하여 합리적인 보수 우선순위를 제안하고자 하였다.
        17.
        2014.04 서비스 종료(열람 제한)
        Important factor of underground structures utilizing precast and rigid wall is joints and connections of wall-to-wall and wall-to-slab for safety performance and durability of underground constructions. In this study, conducting research on the structural safety of the connection as a future laboratory experiments and connection method for the verification of the details of the construction method is expected to proceed research.
        18.
        2014.04 서비스 종료(열람 제한)
        With the recent decreasing of available land, the usage of underground for constructing underground parking lots, subway, underground shopping centers and roads is becoming more frequent than before. Subsequently, due to the changes of the ecosystems and the depletion of ground water in the underground environments are being negatively affected due to coming into contact with corrosive and hazardous substances. In particular, the durability, safety and convenience of the people who reside or utilize these underground structures are reduced by the environmental problems originating from underground ecosystems. Currently there exist a large number of on-going topics of discussion intended to solve the problems, but in order to consolidate a proper and standardized procedure of maintaining waterproofing techniques for these underground structures, a testing method to evaluate the performance of waterproofing and waterleakage resistance in underground structures is necessary.
        19.
        2014.04 서비스 종료(열람 제한)
        Reinforced concrete structures are deteriorated in a few decades due to various causes, such as carbonation. Therefore it is important to evaluate the accurate carbonation depth in order to secure the durability of the structure. In this paper, carbonation depth by drilling excavation and splitting core sample are compared. Also, the procedure for estimating the appropriate repair zone is proposed, with the result of carbonation depth and steel bar detection.