        81.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In contemporary society, vibration and noise in the road nearby buildings have become social problems as vehicles operation has increased. Especially, in the case of the building used to art performance, available suitability of the building is tested by the indoor noise class. Therefore, the purpose of this paper is the measurement of the structure-borne noise of Seoul Art Center nearby Umyeonsan tunnel and analyzing the effects of countermeasure to it. To measure the effects of countermeasure, not only structure-borne noise is measured, but also the vibration is measured, before and after the construction of pavement using pad and porous asphalt. Consequently, the sound pressure level in art center 1st floor is reduced after mat pavement method, structure-borne noise that was high in 25Hz wide-band before pavement decreased regardless of experimental vehicle's velocity. Using porous asphalt pavement the noise was reduced about 3 dB(A).
        4,000원
        82.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The retractable roof structure is used in various fields and it is classified for steel retractable system and soft retractable system. For the domestic industry, it is in the initial phase now and the demand of the retractable roof structure is expected to increase in the future. Therefore, this paper is classified for steel retractable system and soft retractable system from the retractable roof structures in overseas to survey and analyze the cases of wind velocity on retractable roof structure in Japan that uses the same wind velocity criteria like Korea regarding the open-close time and average open-close time for retractable roof area.
        4,000원
        83.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to establish a seismic resistance performance evaluation method that makes sure to secure the seismic resistance performance of the existing mid-low story reinforced concrete structures. This study focuses on the development of the seismic resistance performance evaluation method for the overall seismic resistance performance evaluation on the buildings by applying fuzzy theory. This seismic resistance performance evaluation method considers the mutual relations among the type of force, the type of member, the type of story, and the states of deterioration of the buildings. The total seismic resistance performance index from this method was calculated by the intensity weight of each evaluation item, fuzzy measure, fuzzy integration. Moreover, the evaluation methodology was established in this study to identify the performance level of the Immediate Occupancy, Life Safe, Collapse Prevention by applying the fuzzy theory.
        4,000원
        86.
        2017.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, it is covered in detail the process of generating structural alternatives with geometry change and its optimization by StrAuto. The main roof structure of the Exhibition Center is modelled parametrically and the optimal alt is derived by observing volume changes according to geometry change of main roof truss. Existing studies performed optimization process through sections and properties due to the limitations of shape change, but this study have meaning of performing the optimization with geometry changes which is the most critical skills of StrAuto. By the process of securing a sufficient margin by geometry changes and reducing volume with the optimization of sections, despite of a partial optimization of large space structure, it could be reduced by 11.7% of the total volume.
        4,000원
        87.
        2017.04 구독 인증기관 무료, 개인회원 유료
        Since 1995 the special act for safety management of public facilities have been enacted in Korea. Since then undergoing safety accidents great and small, legal system was revised several times for safety promotion. As part of its efforts Korea Infrastructure Safety & Technology Corporation have periodically evaluated the building safety inspection or diagnosis reports based on Special Act for Safety Control of Public Structures and published annual casebook. This study investigates and examines the cases of bad or poor reports until now. This paper aims at reasoning out the technical and institutional improvement plan for error-prone problems when safety inspection of buildings.
        4,000원
        89.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed indoor and outdoor thermal performance among different types of green roofs and green walls in order to provide information for building greening. When temperature reduction effects of green roofs and green walls were compared to the control, the effects was highest at the green roof and wall treatment, followed by green wall, green roof, and the control, which means there was temperature reduction effects by building greening. Also these temperature reduction effects was influenced by outdoor weather condition such as being typically high in sunny days but not notable in rainy days. In addition temperature reduction was effective as the air temperature was up but was not influenced by wind velocity. As for directions, the west side showed the highest temperature followed by the south and east in the order. Heat flow was found greater in control than in green roof and green wall. In addition, heat flow reversal was found as time went on.
        4,000원
        90.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Nonlinear analysis for seismic performance evaluation of existing building usually takes 4~5 times more than linear analysis based on KBC code. To obtain accurate results from the nonlinear analysis, there are a lot of things to be considered for nonlinear analysis modeling. For example, reinforcing layout, applied load and seismic details affect behavior of structural members for the existing building. Engineer-oriented computerized system was developed for engineers to evaluate effective seismic performance of existing buildings with abiding by seismic design principles. Using the engineer-oriented program, seismic performance evaluation of reinforced concrete building was performed. Nonlinear hinge properties were applied with real time multiple consideration such as section layout, section analysis result, applied load and performance levels. As a result, the building was evaluated to satisfy LS(Life Safety) performance level. A comparison between engineer-oriented and program-oriented results is presented to show how important the role of structural engineer is for seismic performance evaluation of existing buildings.
        4,000원
        91.
        2017.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Seismic analyses of a pile under a large rigid basement foundation embedded in the homogeneous soil layer were performed practically by a response displacement method assuming a sinusoidal wave form. However, it is hard to take into account the characteristics of a large mat foundation and a heterogeneous soil layer with the response displacement method. The response displacement method is relevant to the 2D problems for longitudinal structures such as tunnel, underground cave structure, etc., but might not be relevant with isolated foundations for building structures. In this study, seismic pile analysis by a pseudo 3D finite element method was carried out to compare numerical results with results of the response displacement method considering 3D characteristics of a foundation-soil system which is important for the building foundation analyses. Study results show that seismic analyses results of a response displacement method are similar to those of a pseudo 3D numerical method for stiff and dense soil layers, but they are too conservative for a soft soil layer inducing large soil pressures on the foundation wall and large pile displacements due to ignored foundation rigidity and resistance.
        4,000원
        92.
        2017.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, to estimate the combination of earthquake magnitude (Mw) and distance (R) corresponding to the design spectrum defined in Korean Building Code (KBC) 2016, the response spectra predicted from the attenuation relationships with the variation of Mw (5.0~7.0) and R (10~30km) are compared with the design spectrum in KBC 2016. Four attenuation relationships, which were developed based on local site characteristics and seismological parameters in Southern Korea and Eastern North America (ENA), are used. As a result, the scenario ground motions represented by the combinations of Mw and R corresponding to the design spectrum for Seoul defined in KBC 2016 are estimated as (1) when R =10 km, Mw = 6.2~6.7; (2) when R = 15 km, Mw = 6.5~6.9; and (3) when R = 20 km, Mw = 6.7~7.1.
        4,000원
        93.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        바람이 불어오는 과정에서 지형 및 지물을 지나칠 경우 바람은 흐트러진다. 이 흐트러짐에 의해 풍속은 빨라질 수도 있고 느려질 수도 있다. 특히 건축물이 밀집되어 있는 도심지에서는 주로 속도가 느려지는 현상이 발생한다. 본 연구에서는 실물축척의 도심지를 재현하여 풍동실험을 통해 도심지에서의 차폐효과에 의한 풍속이 느려지는 현상을 정량적으로 평가하였다. 차폐효과에 큰 영향을 미칠 인자들을 도로폭과 주변건축물들의 평균적인 높이로 선정하였고 각각의 조건에 따른 차폐의 정도를 차폐계수로 정의하여 나타내었다. 연구의 결과로부터 도로방향으로 바람이 불 경우 왕복4차선 이하의 도로변에서의 차폐계수는 0.85 이하로 나타났고, 도로직 각방향으로 바람이 불 경우 왕복6차선 이하의 도로변에서의 차폐계수는 0.9 이하로 나타났다.
        4,000원
        95.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        After an earthquake occurred in the Gyeongju, 2016, many low-story buildings have been questioned in terms of the seismic performance since mostly they have been exempted from the seismic design requirement since 1988. In this study, a 3-story moment resisting frame (MRF) building was analyzed and evaluated the seismic performance. Due to the insufficient seismic performance required for the seismic performance levels, three different seismic retrofit schemes were proposed and their seismic performances were re-evaluated. While steel brace and open shear wall retrofit systems mainly focused on the strength retrofit, the VES damper retrofit system is mainly to enhance the energy dissipation capacity of the system and resultes in the increased ductility. The original building and 3 retrofitted buildings were evaluated using the nonlinear static and nonlinear dynamic analyses and suggestions were proposed. Through the analysis of nonlinear time history and push-over using MIDAS/Gen program, damages of the building in terms of top story and average story drift and effect of reinforcement were analyzed.
        4,000원
        96.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper investigates seismic performance of a small-sized single story building in Korea. Nonlinear pushover anlaysis is performed to verify shear failure of RC short columns eventually led to performance degradation. Also, nonlinear time history analysis is performed using the same earthquakes from Gyeongju. Similar failure mode was obtained as in the report where a sudden rupture of the RC columns happened.
        4,000원
        97.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, some popular intensity measures of earthquakes including magnitude, MMI, and PGA as well as their empirical relationships are briefly reviewed since they have been widely used without prudence by mass media, the public, and even the government when asking or expressing the seismic capacity of buildings. The basic concept of current seismic design is also presented in order to facilitate relevant discussions. It is emphasized that expressing the building seismic capacity simplistically in terms of seismological quantities or terminologies like magnitude and MMI is inherently irrational, may be misleading the stakeholders, and should be avoided. Alternative expressions, more rational and consistent with current seismic design philosophy and practice, are recommended.
        4,000원
        98.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Secure operation of hospitals during and right after earthquake is essential. Past lessons from earthquake damages have shown that most of the injured and the death occurred within 30 minutes after earthquake and the portion of nonstructural damage has become significant. However, hospital buildings in Korea have not prepared fully to address such rising issues. This paper is to study what type of damage patterns are related to hospital buildings and how to develop a preparedness plan to keep hospitals operational at all earthquakes if possible. This paper first reviews on past earthquake damages reported as critical to hospital buildings while classifying them into four groups: (1) structural element; (2) architectural-nostructural element; (3) medical equipments and contents; and (4) utility facility. Upon such classification, some detailed concerns can be specified under each group explicitly. Then a hierarchy for hospital building is also developed for the classified groups, which enables us to identify required things for the enhancement of seismic performance of hospital building that consists of heterogeneous elements. To upgrade the level of seismic performance for existing hospital buildings, the concept of performance-based approach can be adopted to address the heterogeneous problems in a systematic and stepwise manner. Finally a conceptual framework for the seismic risk assessment for hospital building is proposed toward the seismic enhancement of hospital buildings using performance-based approach.