검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6,484

        115.
        2023.11 구독 인증기관·개인회원 무료
        In this study, we introduce the validation of the analysis guidelines through preliminary experiments of the draft analysis guidelines before analyzing waste materials (non-combustible). This validation data was applied the accuracy and efficiency of the separation and analysis for the waste such as steel generated from NPP. Steel (non-flammable) was leached the mixed acid and the leaching solution was separated by using the separation guidelines. Steel was corroded with radioactive RM (Co-60, Cs-137) and mixed acid. After drying, the corroded steel was measured the initial radioactivity by a HPGe detector (10,000 seconds). The sample was inserted in a beaker and leached with mixed acid (10 M HNO3 + 4 M HCl) for 2 hours. In this solution, it added 2 ml of H2O2 to increase the leaching effect. The ultrasonic device was adjusted so that the temperature does not exceed 60°C. After elution, the surface of the sample was washed with pure water. The weight of the sample was measured accurately, and recorded the weight loss rate after infiltration. The leaching sample was measured radioactivity by a HPGe detector (10,000 seconds). It was calculated the recovery rate based on the difference in total radioactivity before and after leaching. Before the test, radioactive RM (Co-60, Cs-137) was radioactive deposited by corrosion, but Cs- 137 was not detected in the initial gamma measurement and only Co-60 nuclides were deposited. The recovery rate test results were confirmed to be about 100%.
        116.
        2023.11 구독 인증기관·개인회원 무료
        In the decommissioning process of nuclear power plants, Ni-59, Ni-63 and Fe-55 present in radioactive waste are crucial radionuclides used as fundamental indicators in determining waste treatment methods. However, due to their low-energy emissions, the chemical separation of these two radionuclides is essential compared to others. Therefore, this study aims to evaluate the suitability of various pre-treatment methods for decommissioning waste materials by conducting characteristic assessments at each chemical separation stage. The goal is to find the most optimized pre-treatment method for the analysis of Ni-59, Ni-63 and Fe-55 in decommissioning waste. The comparative evaluation results confirm that the chemical separation procedures for Fe and Ni are very stable in terms of stepwise recovery rates and the removal of interfering radionuclides. However, decommissioning waste materials, which mainly consist of concrete, metals, etc., possess unique properties, and a significant portion may be low-radioactivity waste suitable for on-site disposal. Considering that the chemical behavior and reaction characteristics may vary at each chemical separation stage depending on the matrix properties of the materials, it is considered necessary to apply cascading chemical separation or develop and apply individual chemical separation methods. This should be done by verifying and validating their effectiveness on actual decommissioning waste materials.
        117.
        2023.11 구독 인증기관·개인회원 무료
        Concrete is the primary building material for nuclear facilities, making it one of the most common forms of radioactive waste generated when decommissioning a nuclear facility. Of the total waste generated at the Connecticut Yankee and Maine Yankee nuclear power plants in the United States, concrete waste accounts for 83.5% of the total for Connecticut Yankee and 52% for Maine Yankee. In order to dispose of the low- to medium-level radioactive concrete waste generated during the decommissioning of nuclear power plants, it is necessary to analyze the radioactivity concentration of gamma nuclides such as Co-58, Co-60, Cs-137, and Ce-144. Gamma-ray spectroscopy is commonly used method to measure the radioactivity concentration of gamma nuclides in the radioactive waste; however, due to the nature of gamma detectors, gamma rays from sequentially decaying nuclides such as Co-60 or Y-88 are subject to True Coincidence Summing (TCS). TCS reduces the Full Energy Peak Efficiency (FEPE) of specific gamma ray and it can cause underestimation of radioactivity concentration. Therefor the TCS effect must be compensated for in order to accurately assess the radioactivity of the sample. In addition, samples with high density and large volume will experience a certain level of self-shielding effect of gamma rays, so this must also be compensated for. The Radioactive Waste Chemical Analysis Center at the Korea Atomic Energy Research Institute performs nuclide analysis for the final disposal of low- and intermediate-level concrete waste. Since a large number of samples must be analyzed within the facility, the analytical method must simultaneously satisfy accuracy and speed. In this study, we report on the results of evaluating the accuracy of the radioactivity concentration correction by applying an efficiency transfer method that appears to satisfy these requirements to concrete standard reference material.
        118.
        2023.11 구독 인증기관·개인회원 무료
        A comprehensive understanding of actinide coordination chemistry and its structure is essential in many aspects of the nuclear fuel cycle, such as fuel reprocessing, waste management, reactor safety, and non-proliferation efforts. Managing radioactive waste generated during the nuclear fuel cycle has recently become more important, accordingly increasing the importance of designing appropriate waste forms and storage solutions for long-term waste disposal. Compared to the increase in the need for understanding the chemistry of major radioactive elements, the information on the local structure of the radioactive elements, especially actinides, remains unknown. To probe this issue, X-ray absorption fine structure (XAFS) can be applied. By analyzing the EXAFS (extended X-ray absorption fine structure) and XANES (X-ray absorption near edge structure), the local structure around atoms can be determined. However, the radioactive properties of the nuclides hindered the measurement of EXAFS and XANES, due to the difficulties of preparation, containment, and transfer of the sample. To measure the EXAFS of various compounds regarding the back-end nuclear fuel cycle, laboratory-based EXAFS (hiXAS, HP spectroscopy) has been introduced which can measure the EXAFS and XANES at the energy range of 5-18 keV. Compounds of Copper (Cu foil, CuO samples), Zirconium (Zr foil), and Europium (Eu2O3) were used for the verification of the laboratory -based EXAFS at a given energy range. The measured EXAFS spectrum of various compounds exhibit good agreement with the theoretical data, showing an R-factor of less than 0.02. It was found that each graph has a first peak corresponding to 2.55Å for Cu foil (Cu-Cu), 1.93Å for CuO samples (Cu-O), 3.23Å for Zr foil (Zr-Zr), and from 2.32Å to 2.34Å for Eu2O3 (Eu-O), which agree well with other values from the literature. From the result, it can be implied that this equipment can be used especially in the back-end nuclear fuel cycle field to enhance the understanding of local structure in radiochemistry.
        119.
        2023.11 구독 인증기관·개인회원 무료
        In Korea, extensive industry-academia-research research has already established many facilities and technologies for materials and chemical experiments on non-radioactive substances. However, few facilities have been built to analyze the physical and chemical properties of substances irradiated through neutron irradiation. Korea is planning to decommission Kori-1 and Wolsong-1 in 2027. Extensive analysis of low-level and intermediate-level materials is required to begin decommissioning these nuclear power plants. The material’s composition and level can be identified by analyzing the structure’s characteristics, and a cutting and decontamination plan can be established based on this. In addition, by conducting a nuclide analysis on the waste generated after cutting, suitability for disposal can be secured, and stable treatment can be performed. Accordingly, the Korea Decommissioning Research Institute (KRID) plans to secure infrastructure (hot cells) to analyze the characteristics of intermediate-level decommissioning waste. The goal is to secure high-dose/high-radiation decommissioning waste processing technology through Korea’s first intermediate-level hot cell, support domestic nuclear power plant decommissioning projects, and secure and verify procedures related to nuclide analysis of intermediate-level using hot cells. In addition, by possessing these material properties and nuclide analysis technology, KRID can have a foundation to conduct continuous research on low- and intermediate-level radioactive materials and decommissioning. The purpose of KRID’s establishment is to use this foundation in the future to improve the technological level of the nuclear industry as a whole through linkage between industry, academia, and research institutes.
        120.
        2023.11 구독 인증기관·개인회원 무료
        Alpha activities can be used for categorization, transportation, and disposal of radioactive waste generated from the operation of nuclear facilities including nuclear power plants. In order to transport and dispose of such low- and intermediate-level radioactive waste (LILW) to the Wolsong LILW Disposal Center (WLDC) at Gyeongju, the gross alpha concentration of an individual drum should be determined according to the acceptance criteria. In addition, when the gross alpha concentration exceeds 10 Bq/g, the inventory of the comprising alpha emitters in the waste is to be identified. Gross alpha measurements using a proportional counter are usually straightforward, inexpensive, and high-throughput, so they are broadly used to assay the total alpha activity for environmental, health physics, and emergency-response assessments. However, several factors are thoughtfully considered to obtain a reliable approximate for the entire alpha emitters in a sample, which include the alpha particle energy of a particular radionuclide, the radionuclide that is used as a calibration standard, the uniformity of film in a planchet, time between sample collection and sample preparation, and time between sample preparation and counting. Korea Atomic Energy Research Institute (KAERI) have evaluated the inventory of radionuclides in low-level radioactive waste drums to send every year hundreds of them to the WLDC. In this presentation, we revisit the gross alpha measurement results of the drums transported to WLDC in the past few years and compare them with the concentrations of alpha emitters measured from alpha spectrometry and gamma spectrometry. This study offers an insight into the gross alpha measurement for radioactive waste regarding calibration source, self-absorption effect, composition of alpha emitters, etc.