검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 53

        21.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: This study, compared and verified the test results of post-bearing capacity and the test results of a full-scale vehicle crash test on flat ground and slope ground. METHODS: The results of the bearing capacity test on the barrier post show that, the bearing capacity of the banking section ground and flat ground was relatively large. In the full-scale vehicle crash test, the maximum deformation of the barrier was not large, and the occupant safety indexes(THIV, PHD) were relatively similar. The post-bearing capacity test is a static load test. RESULTS: Therefore, there was a large difference on the flat ground and on the banking section ground because of the effect of soil failure. On the other hand, the full-scale vehicle crash test is close to the impact load. CONCLUSIONS: Therefore, it can be concluded that the whole barrier system was not affected by soil failure alone.
        4,000원
        22.
        2018.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Existing reinforced concrete building structures have seismic vulnerabilities due to their seismically-deficient details resulting in non-ductile behavior. The seismic vulnerabilities can be mitigated by retrofitting the buildings using a fiber-reinforced polymer column jacketing system, which can provide additional confining pressures to existing columns to improve their lateral resisting capacities. This study presents dynamic responses of a full-scale non-ductile reinforced concrete frame retrofitted using a fiber-reinforced polymer column jacketing system. A series of forced-vibration testing was performed to measure the dynamic responses (e.g. natural frequencies, story drifts and column/beam rotations). Additionally, the dynamic responses of the retrofitted frame were compared to those of the non-retrofitted frame to investigate effectiveness of the retrofit system. The experimental results demonstrate that the retrofit system installed on the first story columns contributed to reducing story drifts and column rotations. Additionally, the retrofit scheme helped mitigate damage concentration on the first story columns as compared to the non-retrofitted frame.
        4,000원
        23.
        2018.05 구독 인증기관·개인회원 무료
        Roller-compacted concrete (RCC) has been widely used for construction of pavements [1]. The strength of RCCP can be obtained from not only hydration of binder but also the aggregate interlock resulted from roller-compaction [2]. For this reason, RCCP normally achieves higher strength compared to conventional concrete pavement with similar cement content. Even though RCCP can be provided a good structural performance, it has been difficult to verify the long-term performance though actual field construction. Therefore, this study aimed to investigate the fatigue characteristics and crack development in RCCP based on full-scale fatigue test and accelerated pavement test. In case of full-scale fatigue tests, fatigue behavior was evaluated by using 1 m × 1 m dimensional RCC slab specimens obtained from the field in order to consider the field variability. Fatigue equation derived from this study shows that the number of load repetitions which causes fatigue failure at the same stress level is slightly larger than that of PCA fatigue equation. In order to evaluate the performance of RCCP, two phases of accelerated pavement test (APT) were conducted. In phase one, the performance of RCCP at two different strengths (35.6 and 30.4 MPa) was evaluated. In phase two, the performance of RCCP with different thickness (5, 7.5 and 10 cm) was investigated. The number of load repetition of fatigue crack occurrence in each section was compared to the estimated fatigue failure determined from fatigue equation of RCCP. The crack development in each section was compared to the AASHTO crack model for JPCP. Overall, it was confirmed that RCCP has equal or better performance compared to JPCP the estimation in term of fatigue cracking. The fatigue equation from PCA and cracking model from AAHTO can be used on RCCP at certain design thickness range.
        24.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the current research, a seismic ceiling system as one of non-structural elements in buildings has been developed by applying newly designed vertical hanger clips combined with M-bar channel clips. In order to evaluate the seismic performance of the developed system, full-scale shaking table tests of one story frame structure with the conventional ceiling system or the developed seismic ceiling system were performed with time-history responses under earthquake loads. The developed system was also evaluated by the time-history dynamic analysis. From seismic test and analysis, it was shown that the developed seismic ceiling system could give improved seismic performances to minimize displacements and damages of ceiling systems as well as enhance seismic safety of the ceiling system.
        4,000원
        25.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 실대형 실험과 구조해석을 통하여 현장에서 사용되는 기둥-서까래-도리, 기둥-도리-방풍벽 접합부를 적용한 강관 골조 플라스틱 연동온실의 정적 구조 성능을 분석하였다. 실대형 재하실험 결과는 접합부를 강접합으로 가정한 구조해석 결과와 비교하여 구조물의 횡방향 강성과 각 부재의 하중분담률에서 많은 차이를 보였다. 동고 높이에서 측정한 수평변위는 실험과 구조해석의 차이가 40% 이었고 수직변위는 89%의 차이를 보였다. S3 부재의 발생응력을 기준으로 한 각 부재별 하중분담률을 비교한 결과 실험과 구조해석에서 두 배 이상의 차이를 보이는 부재가 있었으며, 하부측벽이음(S2), 기둥 상부(S7) 등 주요 부재의 실험결과가 구조해석의 하중분담률을 재현하지 않았다. 현장에서 사용하는 접합부가 충분한 강성을 확보하지 않음으로써 구조물에 작용하는 외력을 각 부재에 적절하게 전달하지 못했으며 이로 인해 구조물의 강성이 저하되는 현상이 나타났다. 설계 단계에서 일반적으로 구조 해석에 의해 결정되는 구조성능의 신뢰도는 접합부의 특성을 보다 면밀하게 고려했는지 여부에 따라 좌우 될 수 있다. 따라서 온실 구조 성능에 대한 신뢰성을 높이기 위해서는 온실에 사용되는 다양한 접합부를 고려할 수 있는 구조해석 기술의 개발이 필요하며 설계 기준에서 상세 설계 방법을 보다 명확히 규정해야 할 것으로 판단된다.
        4,000원
        26.
        2016.03 KCI 등재 구독 인증기관·개인회원 무료
        대형마트를 운영하는 회사들은 2012. 1. 17. 「유통산업발전법」이 개정 되어 지방자치단체장들로부터 영업시간 제한 및 의무휴업일 지정의 영업 규제를 받자 이에 불복하여 소송을 제기하였고, 대법원은 2015. 11. 19. 선고 2015두295 전원합의체 판결로 지방자치단체장들의 대형마트에 대 한 영업시간 제한 및 의무휴업일 지정 처분은 적법하다고 판시하였다. 위 대법원 판결에서 다수의견·반대의견·보충의견이 첨예하게 대립한 논쟁의 쟁점은 대형마트 내에 입점하여 있는 용역제공 장소가 영업시간 제한 및 의무휴업일 지정 규제의 대상이 되는지와 관련하여 대형마트로 등록된 대규모점포 의 요건에 관한 구 「유통산업발전법」 및 동법시행령의 해석에 관한 것이었다. 위와 같이 대법원 전원합의체에서 다수의견·반대의견·보충의견이 나 뉠 정도로 「유통산업발전법」 체계가 혼란스럽고 내용이 불명확하여 많은 문제점이 발생하고 있다. 이러한 문제점을 해결하기 위해서는 「유통산업 발전법」상 용어인 매장·점포·시장 등에 대한 개념의 명확화, 대규모점 포 등의 영업형태 분류의 현실화 및 체계화, 영업형태와 관련한 영업규 제의 필요성 등이 반영된 입법 수정작업을 하여 대형마트의 용역제공 장 소를 둘러싼 논쟁을 근본적으로 해결하여야 할 것이다. 또한 「유통산업 발전법」의 입법취지에 반하여 특정한 영업형태를 규제하려는 것은 오히 려 영업형태의 발전과 진화를 막는 결과를 초래하고 유통산업의 발전을 저해하는 결과를 초래할 것이므로 출점규제 내지 영업규제를 최소화 하 여야 하는 방향으로 입법이 이루어져야 할 것이다. 궁극적으로는 대형마 트를 비롯한 대규모점포의 규제는 중소유통업자를 보호하기 위한 경제적 목적 규제 가 아닌 외국 선진 입법례와 같이 환경, 교통, 토지의 효율적 이용 등을 목적으로 하는 사회적 목적의 규제 로 전환하는 입법이 이루 어져야 할 것이다.
        27.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 인천공항 제2계류장 관제소에 설치될 예정인 AMD에 선형제어알고리즘인 속도피드백 알고리즘을 적용하여 제어효율 및 안전성을 평가하였다. 공장성능시험 결과와 수치해석 프로그램의 해석결과를 비교하여 AMD가 설계의도대로 제어를 수행하는지 여부를 분석하였다. 또한 제어알고리즘에 의한 순수제어력에 추가되는 게인스케줄링과 원점보정신호가 제어력에 미치는 영향을 실험을 통해 확인하였다. AMD의 성능시험 결과 게인스케줄링과 원점보정신호는 제어효율에 큰 영향을 미치지 않음을 확인하였으며, 구조물에 큰 외력이 작용하는 경우에 발생하는 AMD 질량체의 과도한 이동으로 인해 구조물에 손상을 입힐 수 있는 문제에 대한 안전성을 검증하였다. 추가적으로 제어효율지수를 도입하여 AMD의 제어 상태를 모니터링한 결과, 적용된 알고리즘이 효과적으로 구조물을 제어함을 확인하였다.
        4,000원
        28.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: This study aimed to evaluate the appropriateness of safety with the standard for threshold zone luminance as specified in the Recommendation for Lighting of Traffic Tunnel, which has been widely adopted worldwide. METHODS: A driving test of the subject in a full-scale road tunnel was conducted. The adaptation luminance and threshold zone luminance, which should be known for the driver to perceive an object within stopping sight distance, were obtained. These values were compared with the adaptation luminance and threshold zone luminance obtained by the existing reduced model test and tunnel lighting standard that has served as a guideline for the current threshold zone luminance standard. RESULTS : According to this study, threshold zone luminance should be increased to at least 1.8 times the value proposed in the existing studies and to twice the domestic tunnel lighting standard (KS C 3703: 2014). CONCLUSIONS : The threshold zone luminance proposed in this study differs largely from that obtained from indoor tests and from the current tunnel lighting standard used worldwide; this difference may be attributed to the fact that the indoor tests did not incorporate driving workload, non-uniformity of luminance distribution in terms of sight, and factors that reduce the visibility of the driver, such as the light reflected into the driver’s eyes. Hence, it is necessary to further review the factors that reduce the visibility of drivers approaching tunnels in order to determine the rational tunnel threshold zone luminance.
        4,200원
        29.
        2015.04 구독 인증기관·개인회원 무료
        In this study, a real-scale specimen of Steel-Confined Prestressed Concrete (SCP) composite girder was tested in a three points bending. Furthermore, vibration tests were performed to verify the dynamic stability of the SCP composite girder for railway bridges. The results of the experimental test were similar to stable rigidity behavior until the static actuator limit load (6300 kN). That is, the SCP composite girder showed a stable rigidity behavior in the ultimate load (3,174 kN) as well as the service load (1,076 kN). Finally, the possibility of resonance of the SCP composite girder has been found to be low.
        30.
        2013.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        항공기 연료셀은 추락 상황에서 승무원의 생존성과 직결되는 중요 구성품으로 회전익 항공기에 적용되고 있는 내충격성 연료셀은 추락시 승무원의 생존성 향상에 큰 역할을 하고 있다. 미육군은 항공기가 처할수 있는 다양한 상황에서 연료셀이제 기능을 발휘할 수 있도록 1960년대 초부터 MIL-DTL-27422 이라는 연료셀 개발규격을 제정하여 현재까지 적용해 오고있다. 해당 개발규격에 규정된 시험 중에서 충돌충격시험은 연료셀의 내충격 성능을 검증하는 시험으로써, 해당 시험을 통과하는 연료셀은 생존가능 충돌환경에서 화재가 발생하지 않아 승무원의 생존성이 대폭 향상될 수 있음을 의미한다. 그러나 충돌충격시험은 작용하는 하중 수준이 너무 높기 때문에 실패 위험성이 가장 큰 시험이기도 하다. 연료셀이 해당 시험을 통과하지 못하는 경우에는 재시험을 위한 비용과 준비기간이 상당히 소요되어 항공기 개발일정에 심각한 지장을 초래할 가능성도 높다. 따라서, 연료셀 설계 초기부터 내충격성능 만족여부에 대한 예측을 위해 충돌충격시험의 수치해석을 통한 실물시험에서의 실패 가능성을 최소화해야 한다는 필요성이 제기되어 왔다. 본 연구에서는 충돌모사 프로그램인 LS-DYNA에서 지원하는 유체-구조 연성해석 방법인 SPH 방법을 사용하여 연료셀 충돌충격시험 수치 모사를 수행하였다. 수치해석 조건으로 MIL-DTL-27422에서 요구하는 시험조건을 고려하였고, 실물 연료셀의 시편시험을 통해 확보한 물성데이타를 해석에 반영하였다. 그 결과로 연료셀 자체의 응력수준을 평가하고 취약부위에 대한 고찰을 수행하였다.
        4,000원
        31.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Rubber laminated bearings with lead core are highly affected by changes in temperature because key materials which are rubber and lead have temperature dependencies. In this study, two full scale LRB(D800, S=5) are manufactured and temperature dependency tests on shear properties are accomplished. The shear properties at the 3rd cycle are used at -10℃, 0℃, 10℃,20℃, 30℃, 40℃ respectively. The double shear configuration, simultaneously testing two pieces, is applied for compression shear test in order to minimize the friction effects due to the test machine, described in ISO 22762-1:2010. Characteristic strength, post-yield stiffness, effective stiffness, equivalent damping ratio are estimated and presented coefficient due to the temperature changes.
        4,000원
        32.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        부재 교차 결합부 조건에 따른 초기강성은 고정 조건인 경우와 비교하여 반고정 조건인 경우 33% 작게 나타났으나 부재 교차 결합부 특성에 의하여 재하지점과 3m 떨어진 지점에서는 9% 크게 나타났다. 즉, 고정 조건인 경우 구조물 전체로 하중이 분산되어 재하지점과 떨어진 지점에서는 상대적으로 반고정 조건 구조물의 강성이 높게 나타났다. 기초 조건에 따른 초기 강성은 강관 삽입 기초의 경우에는 고정기초 조건과 비교하여 31% 크게 나타났으며, 휨강성은 20% 높게 나타났다. 인터페이스 요소(beam interface element, BIE) 및 지반요소(3-D solid element)를 사용하여 재하시험 결과를 기반으로 각종 계수를 산정하고 시험조건과 동일하게 수치모델링하여 유한요소해석을 수행한 결과 실험결과와 유사한 구조거동을 나타냈다. 그러나 극한하중 조건에서는 비선형 특성의 발현 등에 의하여 다소 상이한 결과 값을 보였다. 이상의 결과로부터 플라스틱 필름 온실의 설계 및 구조성능 평가에서 절점 및 지점 조건에 대한 임의 또는 과다한 이상화는 구조물의 성능 평가에 적지 않은 영향을 줄 수 있음을 알 수 있었다. 한편 플라스틱 필름 온실은 세장한 부재로 구성된 유연한 철골 구조물이므로 구조성능 산정에 있어서 좌굴과 함께 대변형 및 지반의 비선형 특성 등을 충분히 고려해야 할 것으로 판단된다.
        4,000원
        33.
        2008.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        실시간 하이브리드 실험법(real-time hybrid testing method)은 구조물의 수치해석부와 실험부 부분구조를 운동방정식으로 통합하여 실시 간으로 동시에 계산과 실험을 수행하는 방법이다 본 연구는 실시간 하이브리드 실험법을 사용하여 수동 및 준능동 MR감쇠기가 설치된 건축구조물의 내진성능을 정량적으로 평가한다. 건물 모델은 실물 크기 5층 건물을 강제진동실험 결과를 통해 식별한 수치모델로 사용하였고, MR감쇠기는 실험적 부분구조르 UTM에 설치되었다. 본 연구에서 수행되는 실시간 하이브리드 실험은 사인파 및 지진파 가진을 통하여 얻은 결과와 전류에 따른 MR감쇠기의 제어력을 이용하여 얻은 Bouc-Wen모델을 사용하여 얻은 해석모델과 일치함으로 그 유효성을 입증하였다. 또한 예비연구로써 구조물의 응답을 최적으로 제어하기 위한 clipped-optimal 제어알고리즘과 modulated homogeneous friction 준능동 제어알고리즘을 MR감쇠기에 적용하였다. 각 전류별 Bouc-Wen모델을 곡선맞춤하여 각각의 Bouc-Wen모델 파라미터를 식별하였으며 그 결과를 준능동 제어알고리즘 수치해석에 적용하였다. 또한 실시간 하이브리드 실험법을 이용한 준능동 제어 실험결과와 해석결과를 비교하여 준능동 제어알고리즘의 성능을 평가함에 있어 실시간 하이브리드 실험이 합리적임을 보여준다.
        4,000원
        35.
        2007.02 구독 인증기관 무료, 개인회원 유료
        To improve water quality of Buji Stream and Shenzhen River, the Bujihe Wastewater Treatment Plant has been reconstructed from the original coagulkation-flocculation sedimentation system into the enhanced hybrid submerged biofilm-activated sludge (EHYBFAS)system developed by the authors. The main design parameters of the EHYBFAS system, process characteristics, operational performance, techno-economic index, and experience in design, construction and operation are described,which set up an example of the municipal wastewater treatment plants using the novel process of EHYBFAS, which has lots of advantages, such as stable and high operational performance with the final effluent quality well meeting 1A-1B standard of GB 18918-2002( Chinese national standard for pollutants of effluent from the MWWTPs), much less footprint of 1ha/(100×103m3/d)) vs 4-5ha/(100×103m3/d), much lower capital and operation costs of 700-800 Yuan(RMB)/(m3/d) and 0.5 Yuan(RMB)/m3 vs 1200-1500 Yuan/(m3/d)and 1.0-1.2 Yuan/m3 and much less sludge production of 0.3g dry solid/g removed BOD5 vs 0.7 g dry solid/removed BOD5 respectively for the MWWTP with AS process.
        5,100원
        36.
        2006.02 구독 인증기관 무료, 개인회원 유료
        This paper presents a design process for viscoelastic dampers and a full-scale test of a 5-story steel structure with added viscoelastic dampers. The mechanical properties of viscoelastic dampers and the dynamic characteristics of the model structure were obtained from experiments, and the results were used in the design process. The additional damping ratios required to reduce the maximum response of the structure to a desired level were obtained first by the convex model. Then the size of dampers to realize the required damping ratio was determined using the modal strain energy method by observing the change in modal damping ratio due to the change in damper stiffness. The designed viscoelastic dampers were installed in the first and the second inter-stories of the model structure, and the system was excited by a hybrid mass driver located on the fifth floor. The experimental results indicated that after the dampers were installed the dynamic response of the full-scale model structure reduced as desired in the design process.
        4,000원
        39.
        2003.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 동반논문에서 연구된 가진방법과 응답특성을 바탕으로, 실물크기의 철골건물에 설치될 점탄성 감쇠기의 설계과정을 다루었으며 가진실험을 수행하여 감쇠기의 진동제어효과를 검증하였다. 최대변위응답을 주어진 수준까지 감소시키기 위하여 요구되는 추가적인 감쇠비를 컨벡스 모델을 이용하여 구하였다. 모드변형에너지법을 이용하여 감쇠기 강성 변화에 따른 모드 감쇠비의 차이를 분석함으로써 감쇠기의 크기를 구하였다. 가새 강성의 효과 또한 모드의 특성을 구하는 과정에 반영하였다. 점탄성 감쇠기는 1층과 2층의 층간에 각각 2개씩 설치되었으며 응답효과를 검증하였다.
        4,000원
        40.
        2003.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        점탄성 감쇠기의 설계를 위한 자료를 얻기 위해 실물크기 5층 건물에 대해 가진과 시스템 식별을 수행하였다. 5층 바닥에 설치된 HWD는 건물을 움직이는 외부 가진력으로 작용하였고, 각 층의 응답을 측정하여 점탄성 감쇠기의 용량과 최적위치에 필요한 자료를 확보하였다. 고유진동수, 감쇠비, 모드와 같은 동적특성을 파악하기 위해 건물에 HMD로 조화하중과 백색잡음 하중을 주어 실험을 수행하였다. 동반논문에서는 건물의 층간에 설계된 점탄성 감쇠기를 설치한 후 응답 거동을 얻기 위한 실험 연구를 수행하였다.
        4,000원
        1 2 3