The suspension system of special tracked vehicle is using hydraulic piston pump to adjust track tension and control vehicle position change. During operation of vehicle on rough field, failure of suspension control was occurred due to the piston pump failure. In this study, investigation was performed to analyze the cause of hydraulic piston pump failure. Main reason of piston pump failure is strong peak pressure and insufficient structural safety of shoe. The static stress analysis considering peak pressure was performed to find the weak point of the shoe. From the result, it is confirmed that pass hole of lubrication is the weakest point. Improved piston shoe shows 27% decrease in maximum stress and satisfies the design target which is less than 40% of stress margin.
Finite Element analysis were carried out to investigate the deformation behaviours of a buckled automotive seat frames made of three different types of materials, i.e., SAPH440, Al6082-T6 and Al7021-T7, when they were subject to external load, based on the ECE R14 regulation to achieve lightweight structure. Also, several thicknesses were applied to the seat frame structures of each material for characterising deformations. It was found that light weight seat frame structure was obtained compared to conventional steel structure when it was made of aluminium under the condition of satisfying ECE R14 regulation. Interpretation result, when changing from SAPHH440 material has a thickness of 1.5mm to Al material has a thickness of 3.0mm, that could checking weight lightening about 47%.
본 연구는 완도수목원 내 붉가시나무 천연림에 대한 솎아베기 강도에 따라 임분의 식생구조 변화를 분석하였다. 붉가시나무림 솎아베기 대상지에서 24과 33속 36종이 출현하였다. 그 중 대조구의 교목층 에서 타 처리구에 비해 출현종수가 많았으며, 아교목층 이하에서의 출현종수는 솎아베기 강도구, 약도 구, 대조구 순으로 나타났다. 식생 층위별 중요치 분석 결과, 교목층은 붉가시나무, 아교목층은 붉가시 나무와 동백나무의 중요치가 높았으며, 관목층에서는 동백나무가 주로 우점하고, 초본층은 마삭줄이 우 점하는 것으로 나타났다. 종 다양도 분석 결과는 솎아베기 강도구가 가장 높았고, 약도구, 대조구 순으 로 나타나, 솎아베기가 하층 식생의 경쟁을 유도하는 것으로 판단되었다. 본 연구 결과는 산림관리와 생물다양성의 보전에 유용하게 활용될 수 있을 것으로 판단된다.
본 연구는 해상에서의 안전사고의 경감과 국민의 생명을 보호하기 위한 목적으로 자체 연구를 수행하여 FRP의 수리공법인 Butt Joint, Lap Joint, V-Scarf Joint(12t, 16t, 20t), X-Scarf Joint(12t 16t, 20t)의 인장강도와 굽힘강도를 통해 이음방식에 따른 구조강도 특성을 실험하였다. 이음 방법에 따른 인장강도와 굽힘강도의 시험편을 종합 분석한 결과, 인장강도의 강도와 굽힘강도의 그래프 패턴은 비슷한 양상으로 증가와 감소를 하였으며, 인장강도와 굽힘강도 모두 X-Scarf-Butt Joint-V-Scarf-Lap Joint 순으로 강도가 우수하였다. 인장강도는 강도특성이 가장 우수한 X-Scarf라 하더라도 Basic Material의 57% 수준의 강도를 나타내었고 굽힘강도는 X-Scarf가 Basic Material의 77% 수준의 강도를 나타내었다. 종합적으로 Over-Lay 구분을 포함하여 X-Scarf 12t 이음이 인장강도, 굽힘강도 특성이 우수하였으며 Lap Joint가 가장 좋지 않았다. Scarf 이음시 Taper 길이에 따른 강도의 차이는 V-Scarf 이음은 Taper의 길이가 가장 큰 20t가 인장강도, 굽힘강도 특성이 우수한 반면 X-Scarf 이음은 Taper의 길이가 가장 짧은 12t가 인장강도, 굽힘강도 특성이 우수하여 상반되는 결과를 나타내었다. 선박에는 많은 Stress가 작용하여 시험편만을 가지고 실험한 본 연구와 직접적인 비교는 힘들지만, 재료의 가장 기본 특성을 인장강도와 굽힘강도 시험을 통해 확인할 수 있다. FRP 국부적인 수리 방법인 Butt Joint, Lap Joint, V-Scarf, X-Scarf 4가지의 이음방법에 따른 시험값과 모재 대비 감소되는 비율을 제시하였고 추가적으로 V-Scarf와 X-Scarf의 Taper 길이별 특성을 12t, 16t, 20t로 구분한 결과값을 제시함으로써 수리 현장에서의 위치별 특성에 맞는 수리 방법의 응용이 가능하도록 하였다.
In this study, shaking table test has been carried out for the dual frame passive control system for seismic performance verification of the proposed system. The proposed system was separated into two independent frameworks that are strength resistant core and frame structure by connecting to the damper. Moreover, the seismic performance improvement of the proposed system has been verified by comparing and analyzing the experimental results of the proposed system with an existing core system. As a result of the shaking table test, acceleration and displacement responses of dual-frame vibration control system are decreased than those of the existing strength resistant type core system. In the case of the core system, while the damage was concentrated on the column of first floor, the damage of the dual system was dispersed in each layer. The damage also was concentrated on the damper, almost no damage occurs to the structural members. It has been emphasized that installed dampers in the proposed dual system reduce the input energy of whole structure by absorbing seismic input energy, which leads overall system damage to be reduced.
1970년대 전국적인 조림정책으로 식재된 낙엽송인공림이 국립공원 내 위치하고 있어 이를 생태적으로 건전하고 종다양성이 풍부한 활엽수림으로 유도하고자 하였다. 이에 오대산국립공원내 월정사지역의 낙엽송림을 대상으로 2009년 밀도별(30%, 50%, 70%) 솎아베기(간벌) 후 2010년부터 2013년까지 활엽수의 천연갱신 양상을 조사하였다.
최근 2012년에서 2013년 사이에 새로이 유입된 흉고직경 2㎝ 이상의 수목은 없었으며 하층에 상당히 많은 양의 초본이 유입되었으며 이와 더불어 복자기나무, 층층나무, 국수나무, 고추나무 등의 교목성 치수들과 관목류들이 상당수 유입되고 있었다. 그러나 목본류의 많은 개체들이 초본과의 경쟁에서 도태되어 고사하고 새롭게 발생됨을 반복하고 있다. 30% 벌채구내의 치수의 발생량은 2013년 440개체로 매년 2배가량 증가하고 있다. 50% 벌채지 또한 목본류의 개체수는 증가하는 경향을 나타냈으며, 발생 1~2년만에 대부분의 개체들이 초본 및 조릿대와의 경쟁에서 도태되어 고사하고 있다. 70% 벌채지는 타 솎아베기(간벌) 시험구와 달리 2012년의 748개체서 오히려 감소한 608개체의 활엽수가 조사되었다. 이는 임상으로 전광이 유입되면서 조릿대의 번성, 두릅나무의 급격한 증가 때문인 것으로 나타났다. 초본류는 조릿대의 영향으로 거의 발생되지 않았다. 낙엽송인공림의 천연활엽수림으로 유도시 50%이상의 상층의 솎아베기(간벌) 밀도는 임상으로 전광을 유입시킴으로 조릿대와 초본류가 번성할 것을 고려하여 일정 수준 이상의 적정 밀도를 유지한 산림작업이 실시되어야 할 것이다.
LNG 선박에서 발생하는 슬로싱 충격하중은 다상유동 및 기체의 압축효과에 따라 CCS에서 발생하는 압력과 구조응답에 큰 영향을 미칠 수 있다. 본 연구에서는 슬로싱 운동 시 LNG의 유동에 의해 발생하는 슬로싱 충격을 시뮬레이션하기 위해서 다상유동을 적용한 수치해석 모델을 제시하였으며, 그 결과를 실험과 비교하여 타당성을 검토하였다. 또한 효율적인 구조응답 계산을 위해 분사모델을 이용한 유체구조 연성해석 방법에 대해서 검토하고 멤브레인형 Mark III 화물창의 강도평가에 적용하여 LNG 화물창의 강도평가를 위한 가능성을 검토하였다.
본 논문에서는 액화천연가스 운송을 위해 사용되는 맴브레인형 Mark Ⅲ 화물창 시스템의 주요 구조물인, 방열 판 구조물의 파손 강도 평가를 수행한 내용을 다루고 있다. Mark Ⅲ 방열 판 구조물을 복합적층 구조물로 고려하였으며 상용화된 범용 유한요소 프로그램인 MSC사의 PATRAN과 MARC를 사용하여 Mark Ⅲ 방열 판 구조물의 유한요소 모델을 개발하였다. 특히, 액화천연가스 화물의 특성으로 인해 Mark Ⅲ 방열 판 구조물이 접하는 상온에서 극저온에 이르는 광범위한 온도분포에 따른 재료 물성치 변화를 유한요소 모델에 포함하였다. 이 유한요소 모델을 기반으로 파손 강도 평가 절차가 확립되었으며, 이 때 Mark Ⅲ 방열 판 구조물의 파손 발생 여부를 판단하기 위해 Hashin, Hill, Hoffman, maximum stress, 그리고 Tsai-Wu와 같은 이방성 파손 기준들을 사용하였다. Mark Ⅲ 방열 판 구조물의 전반적인 구조적 거동을 이해하였으며 이후 초기 파손 영역에서 강도 평가를 수행하여 파손이 발생되었을 때의 위치와 하중 등을 알 수 있었다.
LNG 방열 시스템의 선형 동적해석 모델을 사용하여 슬로싱 충격 압력을 구조해석에 적용 시 사용되는 이상화된 삼각파 압력에 대해서 검토하였다. 삼각파 압력의 최대값, 지속시간, 비대칭성의 충격파에 대한 구조 안전성 평가를 위해서 멤브레인 구조의 허용기준과 슬로싱 압력에 관련된 간략화된 파괴압력에 대해 검토하고, 슬로싱 충격 압력의 지속시간과 비대칭성으로 특징 지워진 이상화된 삼각파 형상의 압력을 고려한 일련의 선형 동적해석을 수행하여 설계기준으로 사용할 파괴압력을 도출하였다. 본 논문에서 제시한 방법을 통해서 방열시스템 구조 요소의 안전성을 평가하기 위한 파괴 압력을 선정할 수 있고 모형실험을 통한 슬로싱 압력과의 비교를 통하여 방열시스템의 구조안전성을 평가할 수 있을 것이라 판단된다. 또한 해석결과를 통해 방열시스템에서의 최대 응력은 매우 짧은 순간의 충격하중 하에서는 압력의 비대칭성 보다는 하중 지속시간에 많은 영향을 받고 있음을 검토하였다.
W-10vol.%ZrC composites reinforced by micrometric and nanosized ZrC particles were prepared by hot-pressing of 25 MPa for 2 h at 1900˚C. The effect of ZrC particle size on microstructure and mechanical properties at room temperature and elevated temperatures was investigated by X-ray diffraction analysis, scanning electron microscope and transmission electron microscope observations and the flexural strength test of the W-ZrC composite. Microstructural analysis of the W-ZrC composite revealed that nanosized ZrC particles were homogeneously dispersed in the W matrix inhibiting W grain growth compared to W specimen with micrometric ZrC particle. As a result, its flexural strength was significantly improved. The flexural strength at room temperature for W-ZrC composite using nanosized ZrC particle being 740 MPa increased by around 2 times than that of specimen using micrometric ZrC particle which was 377 MPa. The maximum strength of 935 MPa was tested at 1200˚C on the W composite specimen containing nanosized ZrC particle.
In this study, the models before and after improving the support structure of seat motor gear nut are investigated by comparing with vibration analysis. The maximum deformation model 1 becomes higher than model 2. The natural frequency of model 2 becomes higher model 1. The design model to be applied into the safe driving is useful effectively by using the analysis result of the height driving module for automotive power seat.
The purpose of this study is to increase applicability of high strength steel, HSA800 to the structure. Selected study of structure is to consider high strength steel, and following parts, 1) Tensile member with no consider of buckling, 2) Truss existing both tension and compression members with small slenderness ratio. This studied structure is included tension column hang on to the upper bridge truss. The structure element quantity with apply HSA800 instead of SM570 is reduced about 38.9% of tension column and 29.7% of bridge truss. In addition, the number of element's division is reduced about two sections due to reduction of self weight that the crane is able to lift up. This improves to reduce erection sequence and construction period which can save about a month. All connections are reviewed as welding and bolt. Also, the cost of welding is reduced about 41.3% due to apply HSA800. In conclusion, applying HSA800 to the hanging structure aggressively can secure economic and constructability.
이 연구의 목적은 축소된 탱크 모델에서 측정되어진 슬로싱 압력을 이용하여 실제 크기의 탱크 모델에서의 압력을 예측하는 것이며, 또한 예측된 압력으로 LNG 코너 블럭의 슬로싱 하중에 의한 구조 강도를 평가하는 것이다.
이 목적을 위하여, Ansys CFX 프로그램을 이용하여 138K급 LNG 화물창 시스템의 크기 비율에 따른 슬로싱 해석을 수행 하였으며, 크기 비율에 따른 슬로싱 평균 압력 및 최대 피크 압력을 측정하였다. 또한, 측정된 압력은 프루드 법칙에 의해 실제 138K 크기의 압력으로 변환하여 실선 크기의 KC-1 코너블럭에 대한 구조강도 평가를 수행하였다.
In this study, a novel-processing route for fabricating microcellular zirconia ceramics has been developed. The proposed strategy for making the microcellula zirconia ceramics involved hollow microspheres as pore former. Compared to conventional dense microspheres pore former, well-defined pore structured zirconia ceramics were successfully fabricated. Effects of hollow microsphere content and sintering temperature on microstructure, porosity, pore distribution, and strength were investigated in the processing of microcellular zirconia ceramics.
An evaluation of the concrete strength has very important meaning in the maintenance and the structural safety. The reliability of ferroconcrete building is weakening and enlarging the life is strongly demanded due to the early deterioration of concrete. Like this social demand, concrete strength presumption is being indirectly executed using the result in parallel with the concrete pouring by material age. This data is usually different as concrete poured practically and the way of hardening and curing. Although existing concrete strength presumption formula is proposed, the material used and the concrete strength is different. And as a matter of remicon, the concrete strength varies according to the site and the way of curing. So the objective of this research is strength evaluation of the structural body concrete according to the concrete pouring and curing temperature change seasonally after using the system which evaluates the structural body concrete strength which is applied the transparent junction-separation mold that is presented. Also there is an objective to present the fundamental data for the constructional quality technique proposal of the structural body concrete developed in relation to field specimen and the strength evaluation method by non-breaking.
2개의 PE 부이가 클램프 및 벨트로 고정되고 그 위에 발판을 지지하기 위한 프레임 등으로 구성된 단위 틀이 외부 재질이 고무 성분인 힌지로연결된 어업용 프레임 구조물의 강도 및 변형을 해석하여 구조적 안정성을 평가하고자 유한 요소법을 이용하여 그것의 구조 해석을 수행하였으며, 해석에서 얻어진 결과는 다음과 같이 요약할 수있다. 1) 고무 힌지로 구성된 어업용 프레임 구조물의 구조적인 안정성을 해석하기 위해서는 힌지 부분을 정확하게 모델링하는 것이 중요하며, 특히 해석 결과는 모델링의 기법에 따라 다르게 나타났다. 2) 고무 힌지의 경우 먼저 재료 시험을 통해 그것의 정확한 불성치를 확보한 후 구조 해석을 수행해야 하며, 단순히 영 계수 E만을 인자로서 해석하는 경우 신뢰성이 있는 결과를 얻을 수 없다는 것을 확인하였다. 3) 초탄성 거동을 하는 고무는 대변형을 하지만 하중과 변형이 선형 관계를 유지하고 있으므로 영 계수 E 등의 물성치를 적절히 사용하면, 힌지를 단순하게 선형 문제로 이상화하여 구조해석을 수행할 수 있을 것으로 사료된다. 4) 동일한 조건에서 파랑 하중에 대한 어업용 프레임 구조물의 구조 응답은 Hogging 상태 즉, 파정이 그것의 중앙부에 오는 것이 정수 중이나 Sagging 상태인 경우보다 크게 나타났다.
본 논문에서 알루미늄 하니콤 샌드위치판 구조(AHSP)의 특성에 대해 해석한 결과는 다음과 같다. 1) AHSP의 H/T비가 낮아질수록 응력이 감소하며, 셀 크기(H)보다는 코어의 두께(T)가 두꺼워질수록 강도와 강성이 증가함을 알 수 있다. 2) AHSP 구조가 동일한 질량에서부터 증가하면서 EASP 구조에 비해 2.5~6.0배 정도의 높은 강도를 보이는 것을 알 수 있다. 3) AHSP의 면재의 두께변화는 AHSP 전체의 강성에 별로 영향을 미치지 못했으나, 심재의 두께가 증가할수록 단면 2차 모멘트의 값이 커지기 때문에 AHSP의 강성이 매우 커짐을 알 수 있다. 4) EASP보다 강성이 큰 AHSP의 고유진동수가 크며, 진동 모드 사이의 차도 커짐을 알 수 있다. 5) 비교연구 결과 AHSP 구조가 EASP 구조보다 적은 질량으로 훨씬 더 높은 강성을 갖는, AHSP 구조의 우수성이 입증된다. 따라서 중량경감이 가장 중요한 문제 중의 하나인 초고속선 및 대형선의 경우 AHSP 구조가 높은 굽힘강성을 갖고 다른 재료에 비해 상대적으로 적은 중량이 필요하므로 구조 재료로서의 적합성을 알 수 있다.
고강도 PSC 콘크리트 휨부재의 비선형 수치해석을 위해 적층법과 설계기준에 의한 비선형 모멘트 -곡률 관계의 계산방법이 제안되었다. 제안된 수치해석에 의한 모멘트-곡률 관계와 처짐계산을 위한 비선형 수치해석 과정에 의한 계산결과는 해석적인 방법에 의한 모멘트-곡률 관계 그리고 기존의 고강도 PSC 콘크리트 휨부재에 대한 실험결과와 비교되었다. 이 논문의 적층법에 의한 에너지흡수율은 강도설계법과 CEB-FIP 제안식보다 약 30%크게 계산되었다. 적층법에 의한 극한하중과 외부일은 각각 실험결과의 92%와 85%로 안전하게 계산되었으며, 강도설계법은 97%와 122%로 극한하중에 대해서는 안전하나 외부일은 과대 평가되었다. CEB-FIP 제안식은 극한하중과 외부일에서 실험결과의 113% 와 173%로 고강도 콘크리트에 대한 극한변형률 0.0035의 적용에 문제가 있었다 제안된 비선형 수치해석 과정은 고강도 PS 콘크리트 휨부재의 거동을 극한상태까지 안정적으로 해석할 수 있었으며, 극한하중의 80%가지 하중-처짐 관계와 균열의 전파정도의 계산결과는 실험결과와 유사하였다