검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 14

        1.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the occurrence frequency of earthquake has increased in Korea, and the interests for seismic reinforcement of existing school buildings have been raised. To this end, the seismic performance evaluations for school buildings that did not accomplish the seismic design are required. In particular, this study checks the eigenvalue analysis, pushover curves, maximum base shears, performance points and story drift ratios, and then analyzes the seismic performance characteristics according to bracing configuration of steel frame system reinforcement. Also, this study presents the practical field application methods through the comparison of analysis results for the seismic performance characteristics.
        4,200원
        2.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Following the social requirement to strengthen field supervision of the asbestos containing materials (ACM) abatement process with regard to asbestos school buildings, this study was conducted to understand the status and characteristics of airborne asbestos that may potentially occur after the ACM abatement process is completed. In the area where a series of asbestos abatement processes were finally completed, comprehensive area air sampling was performed. For sample analysis, Transmission Electron Microscopy (TEM) was used according to The Asbestos Hazard Emergency Response Act (AHERA) method and Phase Contrast Microscopy (PCM) analysis was also performed. Airborne asbestos was detected in 29.5% of the total samples, and the average concentration was 0.0039 ± 0.0123 s/cc (12.3 ± 38.9 s/mm2). 4.5% of the total samples exceeded the AHERA standard (70.0 s/mm2) and the average concentration was 0.0528 ± 0.0256 s/cc (167.2 ± 82.0 s/mm2). Airborne asbestos was no longer detected at the point when AHERA is exceeded after re-cleaning. Most of the detected asbestos was chrysotile (94.4%) and the structure types of asbestos were Matrix (41.4%), Fiber (39.9%), Bundle (10.8%), and Cluster (7.8%). Among the asbestos structures detected through transmission electron microscope analysis, the asbestos structures satisfying PCM-equivalent structures were found to be 6% of the detected asbestos, indicating that there is a limitation of the PCM analysis to check the airborne asbestos in that area. As a result of reviewing the status of airborne asbestos that may potentially occur and the type and dimensions of asbestos structure detected in the area, since the airborne asbestos exposure caused by poor field supervision for the ACM abatement process could not be ruled out, thorough management is necessary. In addition, the result of this study could be used as scientific evidence for establishing and strengthening policies related to ACM abatement, including cases of school buildings.
        4,300원
        3.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We investigated the distribution of asbestos in Seoul for 16 school buildings built before and after 1990, includingkindergartens, elementary schools, middle schools and high schools. The risk assessment standards of AHERA,HSE and ASTM were reviewed and a comparative analysis of assessment standards was conducted in schoolbuildings. For the risk assessment of 16 schools, 170 samples were selected, each of which was assessed usingstandards of AHERA, HSE and ASTM. The school buildings included the ACM (asbestos containing materials)ranged 3-4% of chrysotile and 1-3% of amosite in classroom ceilings and has 7-8% chrysotile in partitions of studenttoilets. The airborne concentrations of fiber materials were ranged with 0.002-0.022 fiber/cc in school buildingsby PCM. In this study, a simplified rating scale was used three categories of Good, Damaged and SignificantlyDamaged. In the result of comparative analysis for the risk assessment criteria, it was found that 113 samples, 132samples and 82 samples were classified as Good when assessed by AHERA, HSE and ASTM, respectively; and46 samples, 29 samples and 53 samples as Damaged, respectively; and 12 samples, 8 samples and 34 samples asSignificantly Damaged, respectively. From the distribution of asbestos and the comparative analysis for the riskassessment criteria, the management plan and new risk assessment were made based on the Korea backgroundshould be established to control asbestos exposure to students from damaged ACM and will be revealed that theassessment for the current condition and potential for disturbance on asbestos in school buildings.
        4,000원
        4.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The core aim of this paper is to empirically scrutinize a strength characteristic and ductility of the beam-column frame of reinforced with steel subjected to the cyclic lateral load. First and foremost, I the author embarks upon making four prototypes vis-à-vis this research. Through this endeavour, the author has analysed cyclic behavior, fracture shape, ductility and energy dissipation of the normal beam-column frame and a beam-column frame of reinforced with steel. In addition, the survey has revealed the exact stress transfer path and the destructive mechanism in order to how much a beam-column frame of reinforced with steel has resistance to earthquake regarding all types of building, as well as school construction. To get the correct data, the author has compared the normal beam-column frame and three types of the beam-column frame of reinforced with steel following these works, the characteristic of cyclic behavior, destructive mechanism, ductility, and Energy dissipation of normal beam-column frame and a beam-column frame of reinforced with steel have been examined clearly.
        4,200원
        5.
        2010.09 구독 인증기관 무료, 개인회원 유료
        Many school buildings are not applied seismic code because of small size structures. But it must be designed to show enough structural performance when subject to earthquake. Especially, most of school buildings are generally used as public shelters when the natural disasters such as flood and earthquake occur. In this study, the seismic risk of the reinforced concrete school building structure was evaluated by using the seismic performance evaluation methods of low-story RC structures developed in Japan and the required seismic performance index. In this paper, the seismic performance of the school building is evaluated by considering this short-column effects, building shape and deterioration.
        4,000원
        6.
        2009.03 구독 인증기관 무료, 개인회원 유료
        In this study, the seismic performance of RC school buildings which were not designed according to earthquake-resistance design code were evaluated by using response spectrum and push-over analyses. From the results of analysis, the efficiency of the seismic retrofitting methods RC shear wall, steel frame, RC frame and PC wing wall for existing RC school buildings was evaluated and analysised. The analysis result indicate that the inter-story drift concentrated in the first floor and most plastic hinge forms in the column of the first story. And results of analysis of the efficiency of the seismic retrofitting indicate that inter-story drift significantly reduced and ductile behavior is expected.
        4,000원
        7.
        2009.03 구독 인증기관 무료, 개인회원 유료
        Since the school buildings are generally used as public shelters when the natural disasters such as flood and earthquake occur, it must be designed to show enough structural performance when subject to earthquake. Major failure mode of the school buildings observed in past earthquakes were shear failure of column of which length is shortened by infilled masonry blocks. ln this study, the seismic risk of the reinforced concrete school building structure was evaluated by using the seismic performance evaluation methods of low-story RC structures developed in Japan and the required seismic performance index which is obtained according to the KBC2008 seismic hazard map and soil types. ln this paper, the seismic performance of the school building is evaluated by considering this short-column effects, building shape and deterioration.
        4,000원
        8.
        2019.10 서비스 종료(열람 제한)
        본 연구는 전단파괴가 예상되는 기둥 실험체에 부착형 및 구속형 보강재를 적용하여 전단능력 향상과 연성 및 에너지 소산능력을 평가하는데 목적이 있다. 이를 위해 축하중과 횡하중을 동시에 저항하면서 전단파괴가 예상되는 실험체를 제작하였으며, 부착형 및 구속형 보강재를 적용한 실험체의 전단보강 성능을 확인하기 위하여 축하중과 동시에 횡하중을 가력실험을 수행하였다. 실험이 진행되면서 기록된 결과를 토대로 하중-변위 곡선을 작성하여 전단보강을 통한 기둥의 보강효과를 비교·분석하였다. 보통모멘트골조 실험체는 8.00%의 층간변위비에서 하중이 급격히 감소함이 나타났다. 그러나 유리섬유 복합체 보강 실험체는 마지막 8.00%의 층간변위에서도 하중이 크게 줄지 않았으며, 이후 더 큰 층간 변위비에서도 하중을 부담할 수 있음을 보여준다. 이러한 차이는 보통모멘트골조보다 유리섬유 복합체로 보강된 실험체의 내진성능확보능력을 보여 준다.
        10.
        2014.02 서비스 종료(열람 제한)
        본 연구에서는 학교 건축물에 발생할 수 있는 화재 상황을 시뮬레이션 하는 기법에 대해 알아보기로 한다. 이에, 기존의 국내외 연구를 통해 화재 상황을 시뮬레이션 하는데 있어 고려해야 할 기본적인 요소를 파악하고 다양한 화재의 원인과 발화량에 따라 나타는 화재양상을 살펴봄으로써 적절한 화재 시뮬레이션 기법을 도출하도록 한다. 화재를 시뮬레이션 하는 방법으로는 CFD (Computational Fluid Dynamics)를 기반으로 하는 공용 소프트웨어인 FDS(Fire Dynamic Simulator)를 이용하였으며, 시뮬레이션의 결과로 시간과 장소에 따라 나타나는 온도정보 및 화염의 전파 양상을 시각화하여 비교분석하였다. 본 연구에서 도출된 화재 시뮬레이션 기법을 이용하여 화재시 피난 대책, 대응인력의 투입 방법을 수립하는데 반영할 수 있으며, 화재 시뮬레이션 결과로부터 얻은 온도 정보를 이용하여 건축 구조부재의 안전성을 평가하는 데에도 활용할 수 있다.
        11.
        2011.02 서비스 종료(열람 제한)
        최근 세계 곳곳에서 대규모 지진이 발생하여 건축물 붕괴에 따른 피해가 속출함에 따라 지진에 대비하기 위해 기존 건축물의 내진 성능을 보강방안에 대한 관심이 높아지고 있다. 그러나 현재 우리나라의 경우, 교육생활의 터전임과 동시에 가구 재난 발생 시 지역주민들의 응급피난장소인 학교 건축물조차 내진설계가 제대로 이루어져 있지 않고 있어, 지진 발생 시 막대한 피해가 예상된다. 현 상황을 극복하기 위해 기존 노후화 학교 건축물의 내진성능을 향상시키기 위한 적절한 보강방안이 제시되어야한다. 본 논문에서는 범용해석프로그램을 통해 기존 노후화 학교 건축물에 대한 비선형정적해석에 결과에 따른 내진보강 후 비선형 시간이력해석을 실시하여 지진하중에 의한 구조물의 비선형 거동을 규명하고 내진 보강 효과를 검증하고자 한다.
        12.
        2011.02 서비스 종료(열람 제한)
        전 세계적으로 대규모 지진이 빈번히 발생하고 있는 가운데 국내의 경우 특히 사람이 집중되어 있는 학교 건축물에 대한 내진성능 보강이 시급한 것으로 조사되었다. 전국적으로 18,329 동 내진설계대상 학교 건축물 중 내진설계가 적용된 건축물은 약 13%인 2,417동에 불과하다. 본 연구에서는 학교 건축물의 내진보강 활성화를 위해 내진보강에 따른 경제성 분석을 수행하였다. 내진보강에 따른 경제성 분석 방법은 건축물의 내진보강으로 인해 발생하는 경제적 편익(benefit)과 내진보강에 소요되는 비용(cost)을 금액으로 산출하여 실제 투자한 비용 대비 효과가 얼마나 있는지를 평가하였다. 대상으로는 국내 내진설계 적용이전인 2000년 이전과 적용이후인 2000년 이후에 지어진 실제 학교 건축물을 선정하였다. 지진으로 인한 건축물의 총 손실은 건축물 구성요소 손실의 합으로 계산되어 짐으로 건축물을 대표적인 구성요소인 기둥, 보, 슬라브 등 3가지 구조부재와 내부벽, 외벽마감, 외부창호, 천정, 기계전기설비 등 5가지 비구조 부재로 구분하였다. 또한 금액 산출방법에는 건축물의 실제피해(physical damage)를 파악하기 위해 개발한 지진취약도 함수와 손상기준별 초과 확률 값을 사용하여 건축물의 지진 손실(loss)을 평가하였다.
        13.
        2011.01 KCI 등재 서비스 종료(열람 제한)
        본 논문은 내진설계규정이 적용되지 않은 국내 철근콘크리트 학교 건물에 관한 해석적 연구이다. 일본의 내진진단과 비선형정적 및 동적 해석을 통하여 대상 건축물의 내진 성능을 평가하였다. 일본의 내진진단 방법에 기초하여 철근 콘크리트 학교 건물의 부족한 내진 성능을 파악하였다. 또한, 횡하중을 받는 학교 건물의 내진거동이 해석적으로 평가되었다. 건축물의 내진 보강을 위하여 1,300kN의 내력을 받는 전단벽과 K형 가새골조가 사용되었다. 비선형 정적해석 결과, 보강에 의한 전단내력은 보강 전에 비하여 30%이상의 향상을 보이는 것으로 나타났으며, 전단벽 보강 시 최대 하중 이후에서 가새골조 보강에 비해 큰강성저하를 나타내었다. 또한, 성능점 산정 결과에서 가새골조로 보강된 건축물이 전단벽으로 보강된 건축물에 비해 30% 이상의 변형능력을 보였다. 한편 비선형 동적해석의 시간이력해석 결과에서는 가새골조와 전단벽에 의해 보강된 건축물의 최대 변위가 보강량이 증가할수록 감소하는 경향을 나타내었다. 본 연구는 이 외에도 지진 지역에서의 건축물의 내진성능 향상을 위해다양한 지반 조건과 지진파를 고려되어야 한다고 판단된다.