검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 10

        1.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Vulnerable populations in healthcare facilities are more sensitive to exposure to indoor air pollutants, and therefore are more affected by such pollutants than the general population. This was the underlying reason why studies of indoor air pollutant concentration distribution and health risk assessment have been conducted targeting facilities, such as daycare centers, medical facilities, elderly care facilities, and postnatal care centers. However, previous studies have mainly focused on daycare and medical facilities for their research, and relatively speaking, studies conducted on the other venues are lacking. Therefore, this study aims to present the current status of indoor air quality and perform a health risk assessment in regard to Formaldehyde exposure at postnatal care centers and elderly care facilities. Here, the study focused on facilities that had undergone pollution level inspections from January 2017 to December 2021. A total of 81 postnatal care centers and 48 elderly care facilities were selected as the subject of the study. Then, the study utilized concentrations of five elements (CO2, HCHO, PM10, PM2.5, TBC) to determine the status of indoor air quality of both postnatal care centers and elderly care facilities. For health risk assessment, HCHO concentration was used. The investigation demonstrated that the yearly average concentration of the five elements stood within the indoor air quality maintenance standards, and the ratio of PM2.5 to PM10 in the two types of facilities was distributed as high as about 70%. In addition, the study showed that HCHO and TBC demonstrated a positive correlation when the relationship between indoor temperature and humidity with the five elements was examined. The health risk assessment showed that the cancer risk level of postnatal care center users stood below 10-6, below the level that is perceived as an acceptable risk. The cancer risk of workers from both postnatal care centers and elderly care facilities and elderly care facility users exceeded the acceptable risk level of 10-6, but was shown to be below 10-4, the maximum acceptable risk.
        4,000원
        2.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Following the social requirement to strengthen field supervision of the asbestos containing materials (ACM) abatement process with regard to asbestos school buildings, this study was conducted to understand the status and characteristics of airborne asbestos that may potentially occur after the ACM abatement process is completed. In the area where a series of asbestos abatement processes were finally completed, comprehensive area air sampling was performed. For sample analysis, Transmission Electron Microscopy (TEM) was used according to The Asbestos Hazard Emergency Response Act (AHERA) method and Phase Contrast Microscopy (PCM) analysis was also performed. Airborne asbestos was detected in 29.5% of the total samples, and the average concentration was 0.0039 ± 0.0123 s/cc (12.3 ± 38.9 s/mm2). 4.5% of the total samples exceeded the AHERA standard (70.0 s/mm2) and the average concentration was 0.0528 ± 0.0256 s/cc (167.2 ± 82.0 s/mm2). Airborne asbestos was no longer detected at the point when AHERA is exceeded after re-cleaning. Most of the detected asbestos was chrysotile (94.4%) and the structure types of asbestos were Matrix (41.4%), Fiber (39.9%), Bundle (10.8%), and Cluster (7.8%). Among the asbestos structures detected through transmission electron microscope analysis, the asbestos structures satisfying PCM-equivalent structures were found to be 6% of the detected asbestos, indicating that there is a limitation of the PCM analysis to check the airborne asbestos in that area. As a result of reviewing the status of airborne asbestos that may potentially occur and the type and dimensions of asbestos structure detected in the area, since the airborne asbestos exposure caused by poor field supervision for the ACM abatement process could not be ruled out, thorough management is necessary. In addition, the result of this study could be used as scientific evidence for establishing and strengthening policies related to ACM abatement, including cases of school buildings.
        4,300원
        3.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated 180 students’ indoor environmental awareness of rest spaces and measured the indoor and outdoor concentrations of PM10, TVOCs, and HCHO in 8 rest spaces from October 2019. 89.4% of the students responded that they use rest spaces at least once a day and most of the respondents are using rest spaces in the university. The largest number of students responded to the tight space as the main cause of air pollution in rest spaces. 62.1% of the students answered they experienced health symptoms from using rest spaces. Among them, 32.5% said they experienced irritation symptoms of eyes, neck, nose, and 12.1% answered that they experienced headaches. Indoor PM10, TVOCs, and HCHO levels did not exceed indoor air quality recommendations nor the maintenance standard for multi-use facilities. Indoor PM10, TVOCs, and HCHO levels did not exceed indoor air quality recommendations nor the maintenance standard for multi-use facilities. According to the type of rest space, concentrations of PM10, TVOCs, and HCHO were higher among the closed-type than open-type rest space. Even if the concentration of pollutants is less than the environmental standard, continuous exposure may cause negative health effects. In addition, considering that 62.1% of the respondents experienced health symptoms, it is deemed necessary to take measures to manage indoor environments in rest spaces and to develop measures to reduce pollutants.
        4,000원
        4.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study conducted a survey on environmental awareness and analyzed outdoor PM10 and heavy metals (cadmium, lead) for 60 local residents living in the Gwangyang national industrial complex from July 2019. 40.0% of subjects responded that local environmental pollution was serious. Especially, there was a high proportion of residents living near the industrial complex or roads where it was perceived that local environmental pollution was serious. The average concentration of PM10 in the outdoors of the houses was 10.95 μg/m3 and the average concentration of heavy metals in PM10 was 1.90 ng/m3 for Cd and 24.92 ng/m3 for Pb. Overall, the average concentration of PM10 and heavy metals revealed a tendency to be high in the houses located near the industrial complex or the roads. As a result of a risk assessment carried out, the cancer risk of Cd was estimated to exceed 106 in the CTE, RME and Monte Carlo analysis. These results suggest that the urgent implementation of specific environmental health education for local residents is necessary.
        4,200원
        5.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was performed to investigate the characteristics of VOCs and carbonyl compounds emitted by smallscale master, offset, and screen printing facilities. During the printing process, concentration measurements of indoor samples were made at each on the printer equipment and the indoor center of the facility. In each case, the window or door served as natural ventilation, and concentration measurements of outdoor samples were made at each air exit point. The results showed that in all printing facilities, the levels of VOCs and carbonyl compounds were much higher in printer equipment compared to indoor levels. Comparative examination of VOCs between printer equipment and the indoors of the facility, the main species of master and offset printer equipment were Methyl isocyanide, 2,2,6-Trimethyloctane, 2,2-Dimethyldecane, 3,7-Dimethyldecane, Toluene, Acetonitrile, and 3- Methoxy-3-methylbutanol. The main species of the indoors of master and offset facilities were Toluene, 2,2,6- Trimethyl-octane, Isopropyl alcohol, 3-Methoxy–3- methylbutanol, Nonane, and Acetone. However, in the screen printing facility, the printer and indoor emission compounds were the same such as 2-Methyl-cyclopentanone, Cyclohexanone, Ethylbenzene, and p-Xylene. Among the compounds released to the outside, Toluene and Acetone were the most abundant species of VOCs and carbonyl compounds, respectively.
        4,300원
        6.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study examined the relevance of impact factors using survey data, standardized mortality rates, and medical utilization rates of study subjects in the Namhae and Hadong regions. The study subjects were found to have lived in the area for more than 20 years, and in terms of lifestyle, they did not smoke, but the rate of drinking was high and showed little exercise. As a result of analysis through logistic regression analysis, it was found that angina pectoris, myocardial infarction and anemia were affected by exercise status, and allergic rhinitis disease showed significant results depending on the presence of smoking. The standardized mortality rate of men in chronic lower respiratory tract diseases in the Namhae and Hadong regions was higher than in the nation. In the case of allergic rhinitis, both men and women in Namhae were slightly lower than those in Nation, and in Hadong, both men and women were higher than in Nation.
        4,000원
        7.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The use of printing inks containing organic solvents by the master, offset and screen printing process implies the release of volatile organic compounds (VOCs) to the work environment. In this study, the volatile content of inks was evaluated by using a thermogravimetric analyzer (TGA), in which the solvent is evaporated. And, to identify the the characterization of VOCs emissions from printing inks, air samples were collected in a thermal extractor (TE) and analyzed by thermal desorption-gas chromatography/mass spectrometry (TD-GC/MS). Weight loss curves suggest that there are two main stages, such as dry fastening and chemical curing. As the result, the first stage of mass loss (below 100oC) was due to VOC evaporation. At this stage, master and offset inks are slightly stable thermally up to 100oC, but screen inks weight loss increases distinctly beyond 25oC. The volatile content is higher in screen inks than in the master and offset inks. The results of the mass-specific TVOC emission rate of the master, offset, and screen inks were 6.3 μg/(g·h), 8.4 μg/(g·h), and 212.2 μg/(g·h), respectively. Then the TVOC emission rate of the screen inks was 25~33 times higher than that of the master and offset inks. The main species were 1-Ethyl-2-pyrrolidinone, 1,2,4-Trimethylbenzene, 1,2,3-Trimethylbenzene, 1,2,4,5-Tetramethylbenzene, 1-Methoxy-2- propanol, Decane, Undecane, and Nonane.
        4,600원
        8.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was performed to assess particulate matter removal efficiency of domestic air cleaner products in a field condition. The assessment also included air cleaners with different air removal mechanisms. The particulate matter (PM2.5) removal test with a different air removal mechanism using air cleaners showed that the electrostatic precipitation technique showed better performance compared with HEPA filters and other types of systems. Its removal efficiency was almost 95% in one of our operation times in the given test condition. It was assumed that not only the type of removal system but also the individual design, supply and exhaust system, and the automatically controlled air volume are involved in the removal efficiency. With respect to the area of application, tests with air cleaners for 40 m2, 60 m2, and 80 m2 areas revealed that particulate matter removal efficiency increased with the air cleaner that had a broad area of application. However, particulate matter removal efficiency by air cleaners did not correspondingly increase with the increase of the area of application. Moreover, the installation location did not influence particulate matter removal efficiency. Our results are expected to be used as the basic information for indoor air quality improvement and prediction using air cleaners.
        4,000원
        10.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to characterize the concentration of and evaluate the pollution level of indoor air pollutants among the public-use facilities located in Seoul that are mainly used by medically sensitive users. The data used in this study were analyzed based on the supervision data provided by Seoul Metropolitan Government Research Institute of Public Health and the Environment. There were 399 nursery schools, 188 medical facilities, 42 elderly care facilities and 96 postnatal care centers. The indoor air pollutants to be investigated were analyzed for PM10, CO2, HCHO, TAB and CO. Through the analysis, it was found that among the surveyed pollutants, TAB levels exceeded the criteria most often, in 54 facilities. Among the surveyed facilities, nursery schools exceeded the criteria most often, in 49 facilities. There was a statistically significant difference between the pollutants in each facility (p<05). However, considering the characteristics of the data used in this study, additional factors should be investigated for factors affecting the concentration of each indoor air pollutant for a more rational evaluation.
        4,200원