        검색결과 119

        1.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study evaluated the effectiveness of odor reduction when spraying inside the Bio-curtain (hereinafter referred to as curtain) according to the exhaust fan operating rate. Spraying is a main factor affecting the ability to odor reduction of curtains. The curtain (total area: 37.9m3) was constructed with two layers of light-shielding screens stretched over a rectangular parallelepiped structure installed around an exhaust fan (630 mm) on the side wall of a pig barn. Air samples for odor analysis were collected from inside the pig barn and outside the curtain. The main odorous compounds such as volatile fatty acids, phenols, indoles, and ammonia were measured. The odor reduction effectiveness was evaluated by total odor activity values (TOAVs) summed to the odor activity values of each odorous compounds. Depending on the exhaust fan operating rate, the reduced rate of TOAVs gradually decreased to the range between 15.67% and 68.80%. Because the contact time between the spraying liquid and the air velocity of the exhaust fan becomes shorter (or there is a reduction in liquid to gas flow ratio) as the exhaust fan operating rate increases. The results of this study can be used as basic data for research into spraying conditions to improve the odor reduction effectiveness of curtains.
        4,000원
        2.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The levels of Indoor radon can increase in newly built apartments that mainly use construction materials such as concrete. However, radon measurement in newly built buildings has only been implemented recently, and there is a lack of sufficient data for radon management purposes. This study aimed to determine the levels of indoor radon in newly built apartments by regions, sizes of household, and floor (lower, middle, upper floor), and to explore the trend of radon reduction by time according to ventilation methods. Indoor radon was measured in 48 households in four regions (Gyeonggi-do and Gangwon-do). Measurements were performed for 48 hours and 24 hours under closed and ventilated conditions using real-time measurement devices FRD400 and RAD7, respectively. To analyze changes in radon concentration by floors, data were collected by dividing households into lower, middle, and upper floors according to their vertical height. The concentrations of indoor radon ranged from 12.1 Bq/m3 to 559.0 Bq/m3 when windows were closed and 12.0 Bq/m3~500.0 Bq/m3 when ventilated (including both mechanical and natural ventilation). On average, the concentration of closed conditions of household when sealed (arithmetic average 185.3 Bq/m3) was 1.5 times higher than the concentration during ventilation (including mechanical and natural ventilation: 123.8 Bq/m3), and around three times higher than the average for mechanical ventilation (65.7 Bq/m3). It was found that the indoor radon concentration statistically increased as the height increased and the size of the house became smaller. Typically, it took 7 to 8 hours to exceed the standard of 148 Bq/m3 after windows were closed. It decreased to less than 148 Bq/m3 within 3 to 4 hours after operating the mechanical ventilation system. However, in the case of natural ventilation, it takes more than 24 hours to reach below the standard value, and the concentrations stagnated after 24 hours. In conclusion, radon concentration in narrow spaces can be relatively high if ventilation is not sufficient due to the nature of apartments with wall-type structures. Therefore, it is necessary to prepare various radon reduction measures according to floor, size, and ventilation methods.
        4,000원
        4.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, two ventilation holes were considered to prevent condensation in the circular column supporting the provision crane on a training ship(Saenuri) for Mokpo National Maritime University. The ventilation holes could be understood as the most simple and inexpensive way to prevent condensation because it was formed only by drilling. If sufficient ventilation is provided, the insulation and corrosion of an electric motor can be improved, and a comfortable state can be ensured in the circular column. The circular column had an electric motor for driving the provision crane so that the basic principle was to utilize the kinetic energy for the flow field from a cooling fan in the circular column. The ventilation holes attenuated the low-velocity area in the circular column and contributed to internal flow circulation with updrafts. The results were discussed through numerical analysis based on computational fluid dynamics.
        4,000원
        5.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Climatologists have warned rapid climate change of the earth and it will cause a big disaster worldwide. the rapid climate change is mostly due to emission of greenhouse gases. To reduce greenhouse gases, many countries have prepared protocols, agreements, and treaties. IMO(International Maritime Organization) have established the protocol to decrease ship’s greenhouse gases emission and they consider the nuclear power source is an option to replace fossils fuels. Our study focused on elemental technologies related to a nuclear powered ship and, the passive residual heat removal system(PRHRS) is one of topics in our study. As the mandatory of the post Fukushima accident, PRHRS for a nuclear powered ship has been studied. We invented the new concepts of PRHRS which is optimized to a nuclear powered ship. The numerical analysis results indicated that the system is very reasonable. Based on the numerical analysis, an experiential loop was set and we preliminary tested the performance of the system under the reduced scale. The experimental results came with the numerical analysis results well.
        4,000원
        6.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        수소는 산소와 반응하여 전기에너지를 만들고 부산물로 물을 생성하므로 친환경 선박의 대체 연료로 대두되고 있다. 그러나 수소는 일반 화석연료와는 달리 낮은 점화 에너지와 높은 가연성 범위로 인하여 폭발의 위험성이 높은 물질이다. 그래서 선박에서 사용 되는 수소의 안전성을 확보하기 위해서 수소의 누출․확산에 관한 유동 특성을 연구하는 것은 매우 중요하다. 본 연구에서는 선박 내부 와 같은 밀폐공간에서 수소가 누출되었을 때 누출량, 통풍량, 환기 방식 등이 환기 성능에 어떤 영향을 미치는지에 대하여 수치적 해석을 수행하였다. 수치해석에는 CFD 상용 소프트웨어인 ANSYS CFX ver 18.1을 이용하였다. 누출량은 1  = 1 g/s로 하여 1 , 2 , 3 로 변경하 였고, 통풍량은 1 Q = 0.91 m/s로 하여 1 Q, 2 Q, 3 Q로 변경하였으며 환기 방식은 typeⅠ, typeⅡ, typeⅢ로 변경하면서 환기 성능을 분석하였 다. 누출량이 1 에서 3 로 증가할수록 저장실 내의 수소 몰분율(HMF)는 약 2.4 ~ 3.0배 높게 나타났으며 통풍량 증가는 누출량에 대비하 여 약 62.0 ~ 64.8 % 정도 환기 성능이 개선에 효과가 있었다. 그리고 폭발의 위험성을 낮추기 위한 통풍량은 최소 2 Q 이상 되어야 하며, 수 소탱크 저장실 내부의 부압 형성을 위해서는 type Ⅲ가 가장 적합한 방식이라고 판단하였다.
        4,000원
        7.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 권취식 측창을 갖는 아치형 단동 플라스틱 온실 내 강제환기장치 설치 및 운용, 환기 성능 개선방안 등을 제안 하기 위해 온실 내부에 유동팬과 배기팬을 설치하여 강제환기 장치 사용에 따른 온실 내부기온 강하 특성을 정량적으로 조 사하였다. 시험은 3가지 환기 조건(측창, 측창+순환팬, 측창+ 순환팬+배기팬)에서 수행되었다. 각 조건 데이터로거를 이용 하여 환기 시작과 동시에 온실 내외부 기온 및 외부환경 변화 를 측정·기록하였고, 환기 방식별 기온차 변화의 평균값으로 부터 정규기온차를 계산하여 기온 강하 효과를 비교하였다. 오전(11:00-12:00)에는 환기 방식에 상관없이 환기 초반 정 규기온차가 일시적으로 증가했다가 감소하는 것으로 나타났 다. 강제환기장치가 더 많이 사용될수록 최대 정규기온차는 1.158에서 1.037로 감소하였고 최대 정규기온차에 도달하는 시간도 340초에서 110초로 단축되었다. 강제환기장치의 사 용은 정규기온차가 0.8까지 감소하는데 소요된 시간을 1,030 초에서 550초로, 0.6까지는 1,610초에서 915초로, 0.4까지는 2,315초에서 1,360초로, 자연환기의 약 60% 수준으로 감소 시켰다. 오후(14:00-15:00)에는 정규기온차의 증가가 관측되지 않았지만, 환기 시작과 동시에 기온차가 감소하기 시작 했다. 또한 강제환기장치가 더 많이 사용될수록 정규기온차 가 0.8까지 내려가는 시간을 560초에서 345초로, 0.6까지는 825초에서 540초로, 0.4까지는 560초에서 345초로, 약 70% 수준으로 감소시켰다. 따라서, 보다 효과적이고 경제적인 환 기를 위해 강제환기장치는 오전과 같이 열부하가 높은 환경에 서 적극적으로 사용하는 것이 바람직하다고 판단된다.
        4,000원
        8.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        수소는 지구 온난화의 주범인 온실가스(GHG) 배출을 감소시키고 선박용 친환경 연료로서 대두되고 있다. 수소는 가연 하한계 (Lower Flammability Limit, LFL)가 4 ~ 75 %이고 폭발 위험성이 큰 물질이다. 그래서 선박용으로 사용되려면 누출에 대비한 안전성이 충분히 확보되어야 한다. 본 연구에서는 수소탱크 저장실에서 수소 누출이 발생한 경우, 급․배기구의 면적 변화가 환기 성능에 미치는 영향을 분석하였다. 급․배기구의 면적은 1A = 740 mm × 740 mm이며 저장실 표면에 크기 및 위치 변경이 쉽도록 설정하였다. CFD 상용 소프트웨 어인 ANSYS CFX ver 18.1을 이용하여 급․배기구의 면적을 1A, 2A, 3A, 5A로 변경하였고, 면적 변화에 따른 저장실 내의 수소 몰분율을 분석하였다. 그 결과 급기구 면적이 배기구 면적 증가에 비해 누출 수소의 농도를 더 감소시켰으며 단일 급기구보다 최소 2A 이상에서 환기 성능이 향상되었다. 급기구의 면적이 증가할수록 수소 층화가 저장실 상부부터 균일하게 형성되었지만 LFL 범위는 벗어나 있었다. 그러나 배기구는 면적을 단순히 증가하는 것만으로는 환기 성능에 미치는 영향은 미비하였다.
        4,000원
        9.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was carried out to investigate the effect of side vent heights on temperature and relative humidity inside and outside the single-span plastic greenhouse (W: 7 m, L: 40 m H: 3.9 m) during natural ventilation. Four different heights (120, 100, 80, 60 cm) of the side vent were used as an experimental condition. Variations of temperature and relative humidity inside and outside the greenhouse and the differences between heights were compared by using one-way ANOVA. In the daytime, the difference in temperature between inside and outside the greenhouse was dropped from 14.0°C to 7.1°C as the side vent height increased. The temperature difference in the nighttime was less than 0.2°C regardless of the height. One-way ANOVA on the temperature difference between heights presented that the statistical significance was founded between all of the combinations of height in the daytime. The difference in relative humidity between inside and outside the greenhouse was grown from –13.8% to – 22.2% with a decrease in the side vent height. The humidity difference in the nighttime was less than 1% regardless of the height. One-way ANOVA on the humidity difference revealed that most of the side vent heights showed significance in the daytime but between 100 and 80 cm was not significant. It seemed because the external air became cooler during the experiment with a height of 80 cm. Conclusively, this study empirically demonstrated that the higher side vents resulted in the decrease of differences in temperature and relative humidity between inside and outside the greenhouse, and also the effect of side vent height was statistically significant. This study may be helpful for deciding the height of the side vent effective for controlling temperature and relative humidity in a single-span greenhouse during natural ventilation.
        4,000원
        10.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Ammonia (NH3) is a basic gas in the atmosphere and is known to play an important role in producing adverse health and environmental effects. Atmospheric NH3 causes stunted livestock growth, decreased visibility, and induces lung diseases when high concentrations occur. In addition, atmospheric NH3 reacts with acidic species (sulfuric acid, nitric acid, etc.) and produces secondary inorganic aerosol. In this study, the NH3 concentration and ventilation of Rooms 1 to 3 inside a sow facility were measured during the period from March 25 to May 31, 2021. It was difficult to conduct long-term field experiments at housing where pigs are raised. However, in order to improve the accuracy and reliability of the data, repeated experiments were conducted in three pig rooms in the same environment. The average concentration of NH3 in Rooms 1 to 3 was measured to be 7.6 ± 2.7 ppm, 8.2 ± 2.8 ppm, and 8.2 ± 2.7 ppm, respectively. The average internal temperatures were 21.0 oC, 21.2 °C, and 21.8 °C, and the internal humidity was 49.3%, 49.2%, and 49.2%, respectively. The ventilation per pig in Rooms 1 to 3 was measured as 60.4m3/hour∙pig, 62.5m3/hour∙pig, and 64.9m3/hour∙pig, respectively. At this time, NH3 emissions from Rooms 1 to 3 were found to be 6.9 ± 0.8 g/day∙pig, 7.9 ± 1.5 g/day∙pig, and 8.2 ± 1.3 g/day∙pig, respectively. As a result of the correlation analysis, the NH3 concentration was analyzed as producing a negative correlation between the ventilation (r=-0.73) and the internal temperature (r=-0.60) increase. Finally, as a result of calculating the national NH3 emission factor, the NH3 emission of one sow room in spring was 7.7 ± 1.4 g/day∙pig, and the NH3 emission of one year was 2.8 kg/ year∙pig.
        4,000원
        11.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we learned about the effects of indoor radon concentration reduction associated with the operation of a mechanical ventilation system at an apartment house. The experimental parameters were mainly the indoor radon level and air change rate, which were controlled by the amount of emissions released and fan motor speed. Even at the high level of radon diffused in an apartment house, indoor radon concentrations converged to the Korean national guideline level within 3 to 4 hours when the air was ventilated at 0.5 ACH and 0.7 ACH. In the case of 0.3 ACH, however, where the degree of ventilation was insufficient compared to the legal air change rate, the high concentration indoor radon could not be sufficiently removed even if the mechanical ventilation system was operated for more than 14 hours continuously. When the indoor radon level was high, the reduction rate was 34.3% for 0.3 ACH, 70.4% for 0.5 ACH, and 69.7% for 0.7 ACH at 6 hours-operation, while at the medium-level, indoor radon can be reduced by 46.2% (0.3 ACH) to 73.2% (0.7 ACH). Depending on the indoor concentration range, it may be required to secure a ventilation rate of 0.5 ACH or more at all times. In addition, in apartment houses with excellent airtight performance, even if indoor radon is at a level similar to the national guideline, it is difficult to expect a reduction in the concentration due to natural decay. Therefore, it is desirable to lower the indoor concentrations as much as possible.
        4,000원
        12.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to identify and assess key parameters affecting greenhouse gas emissions and odor intensity at a naturally ventilated dairy farm. Measurement data of greenhouse gases (CO2, CH4, N2O), odorants (NH3 and H2S), and meteorological data (wind speed, temperature, relative humidity, and solar radiation) were posited as the parameters influencing those emissions. Carbon dioxide and methane emissions correlated well to CO2-equivalent emissions and the contribution of carbon dioxide emissions (R2=0.9181) was greater than that of methane emissions (R2=0.8854). Hydrogen sulfide emissions were highly correlated with odor intensity (R2=0.9989), but the contribution of ammonia emissions to odor intensity was not significant (R2=0.0081). No correlation among CO2-equivalent and odor intensity emissions and meteorological parameters was observed. In this study, the relationship between emissions of greenhouse gases and odor intensity in a naturally ventilated dairy barn mainly depended upon carbon dioxide and hydrogen sulfide emissions. The results in this study will be helpful in the mitigation planning of greenhouse gases and odor in animal feeding operations (CFOs).
        4,500원
        13.
        2022.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        연구는 참외 재배 지에서 흰가루병, 담배가루이 및 두점박이응애가 동시에 발생하였을 때 45, 40, 35°C (대조구)의 온도에서 측창으로 환기 처리 시, 온실 내 온 ․ 습도의 변화, 병충해 발생과 잎말림, 그리고 개화조절에 미 치는 효과를 검토하였다. 3월 3일 ‘히든파워’ 대목에 접붙여진 ‘알찬꿀’ 참외를 40cm 간격으로 격리상에 심었고, 위 에 언급한 병해충이 모든 처리구에서 발생한 6월 18일부터 7월 13일까지 처리하였다. 온실의 온도는 맑은 날에는 설정 온도 지점까지 증가되었고, 45°C 환기 처리에서 고온 고습이 약 9시간 동안 유지되었다. 주간 최고 기온과 최 저 상대습도 차이는 45°C 환기 처리에서 가장 높았다. 환기 처리 11일 후에는 흰가루병과 두점박이응애 피해가 45°C 환기 처리에서 거의 회복되었지만 40°C와 35°C에서는 그렇지 않았다. 처리 14일 후, 담배가루이와 두점박이 응애 밀도는 45°C에서 유의하게 감소하였으나 흰가루병 증상은 유의하게 감소하지는 않았다. 잎말림은 고온에서 유발되었으나 45°C에서도 심하지 않았다. 처리 26일 후, 새로 나온 줄기의 15 마디의 개화수를 조사한 결과, 45°C에 서 암꽃이 전혀 나오지 않았고 수꽃은 1.2개로 나타났다. 이상의 결과는, 고온기에 45°C의 고온에서 2-3주간 환기 처리는 온실 내부의 고온 고습을 유도하여 흰가루병, 담배가루이, 두점박이응애를 통제하고, 개화를 억제하여 참외 의 영양 생장을 회복할 수 있는 방법으로 사료되었다.
        4,000원
        14.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was designed to verify what effect the use of a natural ventilation system can have on improving indoor air quality with regard to radon in various concentration ranges in an apartment house. The results show that both high (2~3 times higher than 148 m3) and low (similar to 148 Bq/m3) levels of indoor radon concentrations can be reduced close to and/or below the Korean IAQ guideline within 6 hours when the natural ventilation system is operated at approximately an air change rate of 0.5. In the case of an air change rate of 0.3, however, the indoor radon levels cannot meet the national guidelines and the reduction effect was insufficient with regard to various radon concentrations. Typically, the air change rate of a natural ventilation system is affected by meteorological factors such as temperature, relative humidity, wind speed, pressure. Its effectiveness varies according to such factors, for that reason, the reduction effects on radon did not increase proportionally with the ventilation time in this study.
        4,000원
        16.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Numerical analysis for flow and noise characteristics of sirocco fan design factors is conducted in this study. 4 cases of blade angle(α=24°~30°) and 5 cases of RPM(390~1170RPM) are calculated. Flow characteristics are compared for the number of blades. Outlet flow rate is tended to decrease as the number of blades increased. There is little difference in the flow characteristics for the angle of blade. The highest outlet flow rate is predicted at α=24°, and the lowest at α=28°. Flow and noise characteristics are compared for α=24° and 26°. Outlet flow rate is almost similar in both cases, but noise for α=24° is predicted higher at high RPM conditions.
        4,000원
        17.
        2021.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본고는 17세기 牛疫의 창궐이 개인과 사회에 환기한 것들에 대해 검토하고, 이를 바탕으로 중등 학교 한문교육에서 災難 관련 자료를 어떤 방향에서 다룰 것인가에 대한 생각을 적은 것이다. 우역이라는 충격 앞에서 개인과 사회는 이전의 삶의 방식과 인습적 가치를 되돌아보게 된다. 소의 노동력이 결여된 농경의 삶에서, 사람들은 소가 생활의 중심에 있던 日常의 소중함을 다시 생각하게 된다. 우역의 창궐은 전원적 삶의 안정성을 흔들고 기층민의 연대에 미세한 균열을 일으키기도 한다. 그리고 하나의 連鎖로서 외교 등 의외의 영역에까지도 파장을 일으키는 것을 볼 수 있다. 당시 조정에서는 몇 가지 정책을 서둘러 시행하는데 이 과정에서 전통적인 유교가치와 충돌하는 일이 발생하기도 한다. 우역 창궐은 소의 도살 문제에 대한 사회적 논의를 계속해서 촉발시키는 역할을 한다. 한편 우역은 기상 이변과 함께 발생함으로써 백성의 삶을 더욱 극단으로 내몰았다. 이러한 분위기는 하나의 압력으로서 사회 내에서 해결 구조를 모색하게 했다. 미래 사회에는 기후, 환경 문제가 사회적인 이슈로 부상하게 될 것이다. 이런 점에서 우역 자료가 함의하는 문제의식을 한문교육의 범위 안으로 편입할 필요가 있다.
        5,700원
        18.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        High concentrations of PM2.5 were generated in new apartments before moving in, and PM2.5 reduction efficiencies using air cleaners and ventilation systems were evaluated. The experimental results for different air cleaner capacities showed that the PM2.5 reduction efficiencies for 46.2 m2, 66 m2, and 105.6 m2 areas were 81.7%, 92.9%, and 92.5%, respectively. Thus, the larger the air cleaning application area, the higher the PM2.5 reduction efficiency. However, there was no difference in the efficiency of overcapacity air cleaners above a certain capacity. The efficiencies of air cleaners located at the living room center, interior wall, and edge were 81.7%, 79.2%, and 75.8%, respectively. There was, therefore, no significant difference in the PM2.5 reduction efficiencies of air cleaners in different locations. Furthermore, the PM2.5 reduction efficiencies at distances of 1 m, 2 m, and 3 m were 81.7%, 81.3%, and 81.7%, respectively. Therefore, there was also no significant difference in efficiency with distance. The PM2.5 concentration decreases rapidly during natural ventilation. Therefore, when the indoor PM2.5 is higher than the outdoor PM2.5, the air cleaner should be used after natural ventilation. The efficiency of PM2.5 reduction using an air supply-type ventilation system in apartments was 35%, which is not high. The simultaneous operation of the ventilation system and kitchen range hood was effective, showing a PM2.5 reduction efficiency of 69.1%. However, a water sprayer was not effective, showing a PM2.5 reduction efficiency of 24.3%. The results of this study suggest that PM2.5 reduction performance should be standardized by evaluating the efficiency of different ventilation systems. Effective usage and maintenance standards for ventilation systems need to be disseminated, and ventilation systems and air cleaners should be used effectively.
        4,000원
        20.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the humidity control effect of a counter-flow ventilator was analyzed in a greenhouse with high relative humidity at night in the winter season. A case of the counter-flow ventilator was 0.96 × 0.65× 0.82(W× D × H, m) and there were heat transfer element and two fans for air supply and exhaust in the counter-flow ventilator. Two counter-flow ventilators were used in this study and the setting humidity of the ventilators was 80%. The temperature and relative humidity at night(18:00-8:00) in the greenhouse were measured. In a greenhouse without a counter-flow ventilator, the average temperature and humidity was 14.9°C, 82.8%, respectively. When the counter-flow ventilator was operated, the corresponding averages were 15.1°C, 79.9%. The independent sample t test of monthly temperature and relative humidity showed no difference in temperature, and a significant difference in relative humidity with 1% of the significance level. Therefore, using the counter-flow ventilator helps to control relative humidity in greenhouse and increase yield.. And further research considering the pros and cons of using the counter-flow ventilator is needed.
        4,000원