Evaluating the effectiveness of the radiation protection measures deployed at the Centralized Radioactive Waste Management Facility in Ghana is pivotal to guaranteeing the safety of personnel, public and the environment, thus the need for this study. RadiagemTM 2000 was used in measuring the dose rate of the facility whilst the personal radiation exposure of the personnel from 2011 to 2022 was measured from the thermoluminescent dosimeter badges using Harshaw 6600 Plus Automated TLD Reader. The decay store containing scrap metals from dismantled disused sealed radioactive sources (DSRS), and low-level wastes measured the highest dose rate of 1.06 ± 0.92 μSv·h−1. The range of the mean annual average personnel dose equivalent is 0.41–2.07 mSv. The annual effective doses are below the ICRP limit of 20 mSv. From the multivariate principal component analysis biplot, all the personal dose equivalent formed a cluster, and the cluster is mostly influenced by the radiological data from the outer wall surface of the facility where no DSRS are stored. The personal dose equivalents are not primarily due to the radiation exposures of staff during operations with DSRS at the facility but can be attributed to environmental radiation, thus the current radiation protection measures at the Facility can be deemed as effective.
The Nuclear Cycle Experiment Research Center is one of the facility of the Korea Atomic Energy Research Institute (KAERI). This facility is a laboratory-scale version of pyro-processing technology. Mixture depleted Uranium (DU) and depleted Uranium (DU) feed material are used in this facility for pyro-research. During summer, air conditioners that maintain temperature and humidity are always in operation to protect analysis equipments. 15 air conditioners are installed in this facility. The condensate which is generated in 15 air conditioners is collected in one place to analyze. Sampling was performed to check the level of contamination, U, pH and gamma radiation test were performed. This paper shows the degree of contamination of air conditioner condensate which is generated in the radiation management area.
Starting with the permanent shutdown of Kori Unit 1, the first waste treatment facility in Korea will be built on the Kori site. In this facility, major process such as decontamination, cutting, radiation measurement and volume reduction of decommissioning waste are performed, and radioactive liquid waste is generated by the waste treatment process and personnel decontamination. The generated liquid waste is finally discharged to the sea through radioactive monitoring system after sufficient treatment to meet the standard radiological effluent control. Whereas the treated liquid waste is additionally diluted through the circulation water discharge conduit and discharged to the sea in the operating nuclear power plants, there is no circulation water in the waste treatment facility. Therefore, a new discharging method for dilution after treatment should be considered. In this paper, the treatment concept and discharge method of radioactive liquid waste system in waste treatment facility are reviewed.
This paper is to study the technology of inspection and history management systems for wind power that are continuously increasing around the world. In the past, inspections and analysis of major devices in renewable energy system have been operated in an analog way that identifies problems through photography and passive method. To improve this problem, we conduct a study on VR-based inspection history management system using 3D texturing technique of drone image. The paper describes the current status and prospects of wind power, research and development of wind power blade inspection and history management systems, experiments and reviews in the field, and expected effects and future utilization of this technology. It is expected that the latest technology for inspection and management of renewable system will be secured and introduced to the site through the development research of this system to reduce maintenance costs and power generation costs.
The purpose of this paper is to understand the key factors for efficient maintenance of rapidly aging facilities. Therefore, the safety inspection/diagnosis reports accumulated in the unstructured data were collected and preprocessed. Then, the analysis was performed using a text mining analysis method. The derived vulnerabilities of tunnel facilities can be used as elements of inspections that take into account the characteristics of individual facilities during regular inspections and daily inspections in the short term. In addition, if detailed specification information and other inspection results(safety, durability, and ease of use) are used for analysis, it provides a stepping stone for supporting preemptive maintenance decision-making in the long term.
PURPOSES : Since the 1990s, underground utility projects have been conducted to solve the problem of aerial communication cables. The purpose of this study is to derive optimal measures for preventing collisions with existing underground utilities and for future maintenance in the implementation of the utilities undergrounding projects. This study considered the identifier sensor and tested the optimal sensor performance for more accurate and systematic management. METHODS : In this study, three representative technologies were selected from identifier sensors generally used in air and the possibility for their use in soil and asphalt was confirmed by simulating the environment via a test construction. Three identifier sensors were selected: BLE (Bluetooth low energy) beacon, ultra-high frequency radio frequency identification (UHF RFID), and a geomagnetic recognizer. The long-term recognition performance of each identifier sensor was tested using the underground depth as a variable and the results were analyzed for comparison.
RESULTS : The results of the test under limited conditions and environment demonstrated that the BLE Beacon had advantages in equipment composition, recognition range, and speed but exhibited problems with batteries in winter. The geomagnetic recognizer did not show the exact location and its influence on the surrounding environment was a disadvantage.
CONCLUSIONS : Although the performance of UHF RFID has been demonstrated to be relatively suitable under these test conditions, it seems that the impact of the more diverse installation depth or medium should be reviewed for actual commercialization.
절화 국화 ‘백마’를 재배하고 있는 관행농가와 스마트팜의 시설현황, 재배환경, 절화생육 및 경영성과를 비교 분석하였 다. 관행농가는 비닐하우스에서 토경으로, 스마트팜은 유리온 실에서 양액재배하고 있었다. 스마트팜은 광량, 온도, 습도, CO2, 풍속, 강우, 양액 pH와 EC 측정을 위한 센서들을 갖추어 자동제어하고 있었으며, 실시간으로 컴퓨터와 휴대전화 어플 리케이션을 이용하여 온실을 관리하고 있었다. 반면에 관행농 가는 환경 측정용 센서와 관비재배용 pH와 EC 센서들이 전혀 없었고, 모든 시스템들을 수동으로 작동하고 있었다. 시설 내의 주간과 야간온도는 관행농가에서 생육 적온보다 낮게 관리되고 있었다. 관행농가의 토양 EC는 3.2dS・m-1로 높게 나타나 절화 생육에 적합하지 않은 것으로 나타났고, 스마트팜은 1.1dS・m-1 로 적절하게 관리하고 있었다. 재배방법에 있어서 토양소독은 관행농가에서는 실시하지 않았으며, 스마트팜에서는 과산화수 소를 이용하여 토양소독을 실시하고 있었다. 그 외에 재배방 법은 큰 차이가 없었으나, 관행농가에서 응애가 많이 발생하 여 피해증상이 나타났다. 절화장, 화폭, 생체중, 엽록소 함량 등과 같은 절화 생육은 관행농가보다 스마트팜에서 더 양호한 것으로 나타났다. 경영성과 측면에서 1,000m2 기준으로 순이 익은 관행농가에서 -419천원이었고, 스마트팜은 4,484천원이 었으며, 생산량과 수취가격이 관행농가보다 스마트팜에서 각 각 22%와 52% 더 높은 것으로 나타났다. 이와 같은 절화의 생육과 경영성과의 차이는 스마트팜의 자동화 설비에 의해 정 밀 생육관리가 가능했기 때문이라고 판단되었다.
Looking at recent safety accidents in buildings, most of them due to lack of FM expertise, and this is due to human resources. In each all industry areas, some companies are competitive, representational, and leading in the market through long-term expertise and research in their respective fields. In the field of FM industry, some companies offer core-competencies in internal and external innovative building management through competition with others. However, old custom and old management form still exist in the FM field. However, an old custom and old management system still exist in the FM field; it forces cost-cutting and caused by carelessness in technical development competitiveness and safety measures. The government control by safety inspection and facility inspection through legislation of building management, but the management is still weak as a side of in the facility management section due to inspect sth as a mere formality and submit a paper report. These facts exist different kind of usage of the building have a three-party encounter between a building owner, user, and FM enterprises. In this research identify survey, especially building owner (manager)’s choice perception priority for optional factors to choose FM enterprises. Based on this, FM enterprises will be forced to seek a new dimension for better building management. In this light, the purpose of the research is to shape changes in the FM market culture safely and providing better service in building management and understanding building owner's insight through this research's information.
본 연구는 레저스포츠 종목 중 사고 위험도가 높은 번지점프시설에 대해 분야별, 국·내외 사고사례 및 우리나라의 번지점프시설 안전점검 관련 자료를 중심으로 분석하였다. 번지점프시설의 심화과정에서 시설분야, 장비분야, 운영분야, 위생분야 내용에 대한 문제점을 도출하고 개선방향을 제시하였다. 그리고 안전사고의 근본적인 원인을 찾고, 운영자 및 종사자의 설문을 통하여 현장에 적합하고 필요한 사항, 운영자 측면의 합리적 운영, 운영요원의 교육 및 안전매뉴얼 숙지, 이용자 측면의 안전성 확보 등을 찾아 관련 법안인 「레저스포츠 진흥 및 안전에 관한 법률」의 기초자료에 적용 및 도움을 줌으로써 안전사고 감소에 의한 재해를 사전에 예방할 수 있을 것으로 기대된다.
중·저준위방사성폐기물 표층처분시설 인간침입시나리오의 ‘평가/해석에 대한 불확실성’의 관리를 위해 GENII를 이용 한 평가결과를 오염토양에 대한 방사선영향평가를 위해 개발된 RESRAD를 이용하여 검증하였다. 중저준위방사성폐기물 표 층처분시설의 인간침입시나리오로 시추후거주시나리오를 선정하여 각 코드의 현상 모사에서 발생하는 한계점을 파악하고 동일한 입력데이터 조건에서 두 코드의 평가결과를 비교분석함으로써 모델링의 불확실성을 분석하였다. 평가결과 각 코드 에서 일부 핵종의 거동모사에 대한 차이는 있었으나 폐쇄후관리기간 이후 선량평가 결과 모든 피폭경로에 대한 경향이 유사 함을 확인하였다. 또한 RESRAD에서 확인한 선량평가 결과를 바탕으로 입력인자에 대한 민감도 분석을 수행하고 주요입력 인자를 도출하였다. 이를 통해 모델링 결과 및 입력인자에 대한 불확실성을 분석하고 안전성평가 결과에 대한 신뢰성을 확 인하였다. 본 연구의 결과는 중저준위방사성폐기물 처분시설의 Safety Case 구축에 활용될 수 있다.
본 연구는 반추동물용 섬유질배합사료(TMR) 제조업체 의 사료안전관리 인식 및 사료 중 위해인자 오염도를 조사 하기 위해 138개소 TMR 제조시설을 대상으로 약 10개월 동안 설문조사를 실시하였다. 조사표는 총 17개 문항으로 구성하였으며, 얻어진 자료는 기술통계분석, 교차분석 및 신뢰도 검정을 통해 분석하였다. TMR 제조시설의 평균 일 일 생산능력은 81.38톤 이었다. 평균 개업연도는 2004년 및 종사인원은 13.7명이었고, 유통경로는 직접거래가 80.4%로 가장 많았다. 사료안전관리 시스템 도입은 사료안전관리의 제도적 여건이 조성된 후 도입이 필요하다는 인식이 주를 이루었으며, 사료안전관리 시스템 구축을 위해서는 사료안 전정보 제공 및 공유가 가장 필요한 조건으로 나타났다. 사료안전성 및 위해물질 관리에 가장 취약한 분야는 곰팡 이 독소인 것으로 조사되었으며, 사료 제조과정에서 가장 위험한 위해인자는 쇠, 파편, 흙 등과 같은 이물질로 나타 났다. 사료 중 위험인자 오염도 조사에서 카드뮴, 비소 및 셀레늄은 허용기준치를 초과한 제품이 일부 조사되었고, 오크라톡신류 및 아플라톡신류는 허용범위내로 조사되었 다. 잔류농약, BSE, 푸모니신 및 살모넬라는 검출되지 않았 으며, 멜라민 및 비단백태질소화합물은 각각 11.35ppm 및 5%로 최댓값을 나타냈다. 규모별 TMR 제조시설의 사료 내 위해인자 오염도는 규모별로 차이가 많았으며, 같은 규 모 내에서도 제조시설에 따라 위해인자의 검출량이 다르 게 나타났다. 또한 소규모에 비해 중규모 및 대규모에서 위해인자 검출량이 더 높아지는 경향을 보였다. 따라서 본 조사결과 TMR 제조시설의 사료안전관리 시스템을 구축하 기 위해서는 사료안전에 대한 정보제공 및 공유가 정책적 으로 제도화되어야 하고, 사료 내 발생하는 곰팡이 독소방 지 및 이물질 제거를 위한 사료관리법의 강화와 원료 공급 처에서 이물질을 제거할 수 있는 장치 도입을 의무화할 필 요가 있다고 판단된다.
Recently, the need for asset management(AM) plan introduction to reduce increasing O&M cost with aging water facilities is on the rise. Therefore, asset inventory classification is necessary as the first step for AM plan construction. In this study, all assets of YW water treatment plant(WTP) were classified as 5 steps. In addition, specific code name was given to each asset which can increase compatibility in constructing the AM programs among WTPs. In the future, codes for attribute and status of asset will be allocated, which can facilitate proper AM operation.
본 연구는 탐방객 인식에 기반한 보다 분석적인 접근의 국립공원 시설관리방안을 제시하고자 하였다. 덕유산국립공 원과 태안해안국립공원 탐방객 대상 총 214매를 유효표본으로 기술분석과 중요도-성취도 분석 실시 결과 태안해안국립 공원은 지속적 관리노력 필요 항목이 4개, 저우선순위 항목이 3개, 과잉 노력 지양항목이 2개로 평가되었다. 덕유산국립 공원은 지속적 관리노력 필요 항목이 3개, 우선시정 필요 항목 1개, 저우선순위 항목이 4개로 나타났다. 관리상태에 대한 전반적인 만족도는 2개소 모두 긍정적이며 국립공원 이용에 대한 종합적인 만족도 또한 3점 이상으로 나타났으나 덕유산국립공원이 태안해안국립공원에 비해 두 분야 모두 더 높게 평가되었다. 태안해안국립공원은 세부 관리속성 모두에서 관리상의 미진한 점이 나타났다. 이는 산악형 국립공원과는 상이한 해상해안형 국립공원의 탐방특성에 기인 한 결과로 보이며 국립공원 유형별로 상이한 이용특성의 분석에 기초한 시설관리가 탐방만족 제고를 위한 필수요건으 로 판단된다.