검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 424

        1.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we examined the effects of gamma irradiation dosage on the mycelial growth of Auricularia auriculajudae and performed analyses of fruiting body yield, growth characteristics, taste, fragrance, and mineral composition. Assessments of mycelial growth in response to gamma irradiation at different intensities revealed an enhancement in the growth of fungi exposed to irradiation at 200 Gy. Fruiting body yield was also highest at 200 Gy, followed by 800 Gy and the control group. On the basis of these observations, we subsequently applied gamma ray doses of 200 and 800 Gy to examine the effects of irradiation on fungal quality characteristics. In terms of the taste of fruiting bodies, we detected no significant differences among the control, 200 Gy, and 800 Gy groups. Contrastingly, with respect to fragrance, we found that fungi treated with 200 Gy were characterized by a pattern that differed from those of the control and other treatment groups. Furthermore, whereas we detected no significant difference among treatments with respect total dietary fiber content, calcium content was found to be higher in the treatment groups compared with the control group, with the highest content being measured in fungi exposed to 800 Gy irradiation. Copper content was confirmed to be higher in the control group, whereas there were no significant differences between the fungi irradiated with 200 and 800 Gy. Contrastingly, the highest levels of zinc were detected in response to 200 Gy irradiation, followed by 800 Gy. Collectively, our findings thus indicate that gamma irradiation can contribute to promoting increases in the fruiting body yield and mineral contents of mushrooms.
        4,000원
        2.
        2023.11 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        ZnO/Cu/ZnO (ZCZ) thin films were deposited at room temperature on a glass substrate using direct current (DC) and radio frequency (RF, 13.56 MHz) magnetron sputtering and then the effect of post-deposition electron irradiation on the structural, optical, electrical and transparent heater properties of the films were considered. ZCZ films that were electron beam irradiated at 500 eV showed an increase in the grain sizes of their ZnO(102) and (201) planes to 15.17 nm and 11.51 nm, respectively, from grain sizes of 13.50 nm and 10.60 nm observed in the as deposited films. In addition, the film’s optical and electrical properties also depended on the electron irradiation energies. The highest opto-electrical performance was observed in films electron irradiated at 500 eV. In a heat radiation test, when a bias voltage of 18 V was applied to the film that had been electron irradiated at 500 eV, its steady state temperature was about 90.5 °C. In a repetition test, it reached the steady state temperature within 60 s at all bias voltages.
        4,000원
        3.
        2023.11 구독 인증기관·개인회원 무료
        Most of the C-14 produced is in the organic form, generated as methane (14CH4), methanol (14CH3OH), formaldehyde (14CH2O), and formic acid (14CO2H2). When analyzing C-14, it is transformed into the form of 14CO2, and its concentration is determined using LSC. Typical examples include the wet oxidation method, the combustion or Pyrolysis. The wet oxidation method uses strong acids and involves repeated operations, which generates large amounts of acid waste and secondary radioactive waste. The combustion method uses high temperatures, which requires an oxygen device. Pyrolysis also requires high temperature in a vacuum and catalysts. Catalysts are expensive because they are platinum-based. To compensate for these shortcomings, a C-14 analysis method using UV irradiation was developed. In this study, 100 mL of distilled water mixed with formic acid (CO2H2), potassium persulfate (K2S2O8), and silver nitrate (AgNO3) was irradiated with a 320-390 nm UV lamp to conduct a CO2 production reaction experiment. The UV range was measured using a photometer (UV Power puck II). The beaker was made of quartz in 150 mL size with three inlets : a temperature measurement, a sample inlet, and a collection tube connector. We changed the UV lamp used from a 450 W halogen lamp to a 100 W LED, which has a lower temperature and is safer. As a result of the experiment, CO2 bubbles were generated in the collection tube, due to the UV irradiation react, which uses oxidizer and catalysts. The maximum temperature of the solution irradiated with the LED UV lamp was less than 56°C. It confirmed the rate of bubble generation changed depending on the lamp distance, the amount of sample, oxidizer, and catalyst. In an experiment to confirm the reaction caused by heat, it was found that although a reaction occurred due to heat, the reaction was significantly lower than when using a UV lamp. The reproducibility experiment was conducted three times in total under the same conditions. It showed the same pattern. In the future, we plan to select mock samples, collect 14CO2 in Carbo- Sorb, and analyze them using LSC. The results of this research will be used as a technology to recover C-14 more safely and efficiently and will also be used to expand its application to the treatment of other wastes such as waste liquid and waste resin through simulated samples.
        4.
        2023.11 구독 인증기관·개인회원 무료
        Notice of the NSSC No.2021-14 defines the term ‘Neutron Absorber’ as a material with a high neutron absorption cross section, which is used to prevent criticality during nuclear fission reactions and includes neutron absorbers as target items for manufacture inspection. U.S.NRC report of the NUREG-2214 states that the subcriticality of spent nuclear fuel (SNF) in Dry Storage Systems (DSSs) may be maintained, in part, by the placement of neutron absorbers, or poison plates, around the fuel assemblies. This report mentions the need for Time-Limited Aging Analysis (TLAA) on depletion of Boron (10B) in neutron absorbers for HI-STORM 100 and HISTAR 100. Also, this report mentions that 10B depletion occurs during neutron irradiation of neutron absorbers, but only 0.02% of the available 10B is to be depleted through conservative assumptions regarding the neutron flux or accumulated fluence during irradiation, which supports the continued use of the neutron absorbers in the SNF dry storage cask even after 60 years of evaluated period. There are several types of commercially available neutron absorbers, broadly classified into Boron Carbide Cermets (e.g., Boral®), Metal Matrix Composites (MMC) (e.g., METAMIC), Borated Stainless Steel (BSS), and Borated Al alloy. While irradiation tests for neutron absorbers are primarily conducted during wet storage systems, there are also some prior studies available on irradiation tests for neutron absorbers during dry storage systems. For examples, there is an analysis of previous research on high-temperature irradiation test of metallic materials and identification of limitations in existing methodologies were conducted. Furthermore, an improvement plan for simulating the high-temperature irradiation damage of neutron absorbers was developed. In report published by corrosion society summarizes the evaluation results of the degradation mechanisms for Stainless Steel- and Al-based neutron absorbers used in SNF dry storage systems.
        5.
        2023.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Sulfur and nitrogen co-doped carbon dots (NSCDs) were quickly synthesized by the microwave-assisted method from triammonium citrate and thiourea. NSCDs showed a quantum yield of 11.5% with excitation and emission bands at 355 and 432 nm, respectively. Also, a fluorescence quenching was observed in the presence of Pb(II) ions, and the as-synthesized CDs were used as a sensitive probe for detecting Pb(II) in water and food samples. The results showed the optimal conditions for Pb(II) determination were CDs concentration of 0.02 mg mL− 1 at pH 6.0–7.0 and an incubation time of 20 min. The relative fluorescence intensity of NSCDs was proportional to Pb(II) concentrations in the range of 0.029–2.40 and 2.40–14.4 μmol L− 1 with a correlation coefficient (R2) of 0.998 and 0.955, respectively, and a detection limit of 9.2 × 10– 3 μmol L− 1. Responses were highly repeatable, with a standard deviation below 3.5%. The suggested method demonstrates the potential of a green, fast, and low-cost approach for Pb(II) determination in water, tea, and rice samples with satisfying results.
        4,000원
        6.
        2023.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        An irradiation hardening of Inconel 718 produced by selective laser melting (SLM) was studied based on the microstructural observation and mechanical behavior. Ion irradiation for emulating neutron irradiation has been proposed owing to advantages such as low radiation emission and short experimental periods. To prevent softening caused by the dissolution of ' and '' precipitates due to irradiation, only solution annealing (SA) was performed. SLM SA Inconel 718 specimen was ion irradiated to demonstrate the difference in microstructure and mechanical properties between the irradiated and non-irradiated specimens. After exposing specimens to Fe3+ ions irradiation up to 100 dpa (displacement per atom) at an ambient temperature, the hardness of irradiated specimens was measured by nanoindentation as a function of depth. The depth distribution profile of Fe3+ and dpa were calculated by the Monte Carlo SRIM (Stopping and Range of Ions in Matter)-2013 code under the assumption of the displacement threshold energy of 40 eV. A transmission electron microscope was utilized to observe the formation of irradiation defects such as dislocation loops. This study reveals that the Frank partial dislocation loops induce irradiation hardening of SLM SA Inconel 718 specimens.
        4,000원
        8.
        2023.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 실험은 마이크로웨이브 처리가 상추 유묘의 생육 변화와 이차대사산물 함량의 변화를 알아보고자 수행되었다. 파종 후 3주째 상추 유묘에 2.45GHz 주파수와 200W의 마이크로 웨이브를 0, 4, 8 및 12초 동안 처리하고, 4주간 식물공장에서 재배한 후 생육 및 성분 분석을 수행하였다. 지하부와 지상부 의 생체중과 건물중, 엽면적, 엽장 및 엽수는 마이크로웨이브 처리시간이 증가할수록 감소하였다. 4초 처리구와 비교하여 12초 처리구에서 chlorophyll a, chlorophyll b 및 총 carotenoids 의 함량이 증가되었으며 총 페놀 함량은 감소하였다. 무처리 구와 비교하여 8초 처리구에서 총 플라보노이드 함량이 감소 하였다. 이러한 결과들은 산화적 스트레스에 의해 이차대사 산물 함량이 변화된 것으로 사료된다. 총 플라보노이드 함량 을 제외한 이차대사산물 함량은 각 처리구에서 무처리구와 비 교하여 유의한 차이가 없었지만, 각 처리구 사이의 유의한 차 이는 200W와 2.45GHz의 마이크로웨이브 처리가 4주 후 상 추의 이차대사산물 함량에 영향을 줄 수 있다는 것을 시사한다.
        4,000원
        9.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated durian (Durio zibethinus) peels to produce powdered activated carbon (DPAC). The influence of process variables such as carbonization temperature, activation time, contact time, CO2 flow rate, and adsorption dosage was optimized using response surface methodology (RSM). A six-factor and two levels Box–Behnken design (BBD) was used to optimize the parameters. The independent variables were activation temperature (°C), duration (min), CO2 flow rate during the activation process (L/min), irradiation of adsorbent (kGy), irradiation duration (min), and adsorbent dosage (g) while phenol removal (mg/L) was the dependent variable (response). Following the observed correlation coefficient values, the design was fitted to a quadratic model (R2 = 0.9896). The optimal removal efficiency (97.25%) was observed at an activation temperature of 900 °C, activation time of 30 min, CO2 flow rate of 0.05 L/min, irradiation dose of 100 kGy, contact time of 35 min and adsorption dosage of 0.75 g. The optimal DPAC showed a BET surface of 281.33 m2/ g. The removal efficiency was later compared with a commercially available activated carbon which shows a 98.56% phenol removal. The results show that the durian peel could be an effective precursor for making activated carbon for phenol removal, and irradiation can significantly enhance surface activation.
        4,000원
        10.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Some plant pathogenic bacteria species are environmentally high-risk organisms that have a negative impact on agricultural production. Experiments with these pathogens in a biosafety laboratory require safety protocols to prevent contamination from these pathogens. In this work, we investigated the efficacy of using UV-C irradiation for the purpose of sterilizing an important plant pathogenic bacterium, Erwinia pyrifoliae, in a laboratory setting. For the test, the pathogen (1.71 × 108 CFU/ml) was inoculated on the surface of Potato Dextrose Agar (PDA) and the inoculated media were placed on a work surface in a biosafety cabinet (Class 2 Type A1) as well as on three different surfaces located within the laboratory: a laboratory bench, a laboratory bench shelf, and the floor. All the surfaces where the media were placed were in range of the UV-C beam projected by the UV lamp installed in the ceiling of the BSL 2 Class biosafety laboratory. Measurements of the reduction rate of bacteria under UV-C irradiation were conducted at different time intervals: after 10 minutes, 30 minutes, 1 hour, 2 hours, and 3 hours, respectively. The reduction rate of bacteria ranged from 90% to 99% after 10min irradiation, from 97.8% to 100% after 30 minutes of irradiation, from 99.1% to 100% after 1 hour of irradiation, and from 99.99% to 100% after 2 hours of irradiation. After 3 hours of irradiation, the pathogen was completely killed in all the test conditions. In the cases of the laboratory bench and the shelf of the laboratory bench, the effectiveness of UV-C irradiation differed slightly between the site where the bacteria located vertically under the lamp and the site where the bacteria were located 1 meter away horizontally from the site under of the lamp.
        4,000원
        11.
        2023.05 구독 인증기관·개인회원 무료
        Since 2018, Central Research Institute of Korea Hydro & Nuclear Power (KHNP–CRI) has been operating an X-ray irradiation system with a maximum voltage of 160 kV and 320 kV X-ray tube to test personal dosimeters in accordance with ANSI N13.11-2009 “Personnel Dosimetry Performance- Criteria for Testing”. This standard requires that dosimeters for the photon category testing be irradiated with the X-ray beams appropriate to the ISO beam quality requirements. KHNP-CRI has implemented the fourteen X-ray reference radiation beams in compliance with ISO-4037-1, 2, and 3. When installing the X-ray irradiation system, KHNP-CRI evaluated the uncertainties of dose conversion coefficients for deep and shallow doses, based on “Catalogue of X-ray spectra and their characteristic data – ISO and DIN radiation qualities, therapy and diagnostic radiation qualities, unfiltered X-ray spectra” published by Physikalisch Technische Bundesanstalt (PTB). A CdTe detector (X-123, AMPTEK) with disk type collimators made of tungsten was used to acquire X-ray spectra. The detector was located at 1 m from the center of the target material in the Xray tubes. Six uncertainty factors for the dose conversion coefficients for the fourteen X-ray beams were chosen as follows; the minimum and maximum cut-off energies Emin and Emax, the air density (ρ), the accuracy of the high-voltage of the X-ray tube, statistics of the pulse height spectra and the unfolding method. For example, uncertainty of each quantity for a HK30 beam was calculated to be 0.3%, 2.32%, 0.19%, 1.25%, and 0.13%, and 0.18%, respectively. The combined standard uncertainty for the deep dose conversion coefficient of the HK30 beam was calculated to be 2.67%. The coverage factor corresponding to a 95 percent confidence interval was obtained as k = 1.8 using a Monte Carlo method, which is slightly lower the coverage factor of k = 1.95 for a Gaussian distribution. This seems to result from that two dominant uncertainties, the unfolding uncertainty and minimum cut-off energy uncertainty, follow a rectangular distribution.
        12.
        2023.05 구독 인증기관·개인회원 무료
        The radiolytic decomposition of oxalic acid was investigated using gamma irradiation for decontamination of nuclear power systems. The study used high-purity analytical grade chemicals, with initial concentrations of oxalic acid prepared at 1, 2, 5, and 10 mM, and the initial pH was adjusted to 2-3 at each test condition. Gamma irradiation was performed using a high-level Co-60 source, and absorbed doses were 5, 10, 20, 30, and 50 kGy. The results showed that the efficiency of gamma irradiation decreased with longer gamma exposure time, and the G-value increased with the initial concentration of oxalic acid. Interestingly, the G-value decreased with accumulated radiation dose, but the removal increased. The dose constant ranged from 0.1695 to 0.0536 kGy-1 at different initial concentrations, and the G-value was inversely proportional to the dose constant. The study concluded that oxalic acid was successfully degraded by gamma irradiation, and 92% removal was obtained at the initial concentration of 10 mM. The mineralization of oxalic acid at higher concentrations was more difficult due to the great number of generated intermediates.
        13.
        2023.05 구독 인증기관·개인회원 무료
        Korea Atomic Energy Research Institute (KAERI) has been operating the Post Irradiation Examination Facility (PIEF) for spent fuel. The facility has pools and hot cells for handling and examining fuel assemblies and rods. In the first hot cell, non-destructive tests such as visual inspection, defect detection, oxide layer thickness measurement, and gamma scanning are performed on a full-length fuel rod. Then, the fuel rod is transported to the next hot cell for measuring the rod internal pressure (RIP). After the RIP measurement, the fuel rod is cut by a cutting machine to make samples for destructive tests. Currently, the existing cutting machine is broken, so a new machine needed to be designed and manufactured. The major considerations for designing the cutting machine were convenience of remote handling and decontamination. The machine was modularized and its handling parts were designed to be easily controlled by manipulators. The cover was designed to prevent radioactive contamination of the surrounding area.
        15.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        High-risk microbial pathogens are handled in a biosafety laboratory. After experiments, the pathogens may remain as contaminants. To safely manage a biosafety laboratory, disinfection of microbial contaminants is necessary. This study was carried out to evaluate the effect of UV-C irradiation for the disinfection of a high-risk plant pathogenic bacterium Erwinia amylovora in a laboratory setting. For the test, the bacterium (8.7 × 106 CFU/ml) was embedded on the surface of PDA and placed on the work surface in a biosafety cabinet (Class 2 Type A1), and on the three different surfaces of the laboratory bench, laboratory bench shelf, and the floor which were positioned in a straight line from the UV lamp installed in the ceiling of the biosafety laboratory (BSL 2 class). UV-C irradiation was administered for 10min, 30min, 1 hr, 2hr, 3 hr, and 4hr, respectively. The reduction rate of bacteria ranged from 95% to 99% in regard to 10 min irradiation, from 97% to 99% in regard to 30 min irradiation, from 99.8% to 99.9% in regard to 1 hr irradiation, and higher than 99.99% in regard to 2 hr irradiation. The bacterium was completely inactivated after 3 hr irradiation. A similar UV-C irradiation effect was obtained when the bacterium was placed at a distance of 1 m from the three different surface points. Bacterial reduction by UV-C irradiation was not significantly different among the three different surface points.
        4,000원
        16.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Magnetically separable and reusable zinc ferrite/reduced graphene oxide ( ZnFe2O4/rGO) nanocomposite has been prepared by hydrothermal method. The results illustrate that the construction of ZnFe2O4 and rGO occur concurrently in a hydrothermal reaction that initiates the formation of rGO-wrapped ZnFe2O4 nanospheres. The morphological and structural features of the ZnFe2O4/ rGO nanocomposites reveal that the rGO nanosheets anchored to the ZnFe2O4 sphere act as a self-protective clamping layer to avoid the photo corrosion effect under photo irradiations. The nanocomposites express the soft magnetic behavior with high saturation magnetization under annealing temperature at 300 °C, which may attribute to the well-defined crystalline structure and surface defects. In addition, the GZF 300 nanocomposites exhibit the enhanced photocatalytic degradation over Rhodamine B dye which is 3.4, 1.15, and 1.32 times higher than that of ZF, GZF, and GZF 600 over under visible irradiation in 120 min. The GZF 300 nanocomposites demonstrate their ability to degrade RhB efficiently, even after several photocatalysis cycles with high catalyst recovery by its magnetically separable behavior. The high densities of oxygen defects improvise electron transfer from ZnFe2O4 to rGO and delay the recombination process of the nanocomposite, resulting in enhanced visible photocatalytic activity. The strong magnetic properties of rGO wrapped ZnFe2O4 nanocomposite catalysts the easy separation from the suspension system for multiple usages in water treatment.
        4,300원
        17.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Ion-beam irradiation(IB) on HfO2 surface induced high-performance liquidcrystal(LC) driving at a 1-V threshold with vertical alignment of liquid crystals(LC). The high-k materials Atomic layer deposition was used to obtain LC orientation on ultra thin and high-quality films of HfO2 layers. To analyze surface morphological transition of HfO2 which can act as physic alignment effect of LC, atomic force micro scopy images are employed with various IB intensities. The contact angle was measured to elucidate the mechanism of vertical alignment of LC on HfO2 with IB irradiation. Contact angle measurements show the surface energy changes via IB intensity increasing.
        4,000원
        18.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Carbon fibers (CFs) are considered promising composite materials for various applications. However, the high cost of CFs (as much as $26 per kg) limits their practical use in the automobile and energy industries. In this study, we developed a continuous stabilization process for manufacturing low-cost CFs. We employed a textile-grade polyacrylonitrile (PAN) fiber as a low-cost precursor and UV irradiation technique to shorten the thermal stabilization time. We confirmed that UV irradiation on the textile-grade PAN fibers could lower the initial thermal stabilization temperature and also lead to a higher reaction. These resulted in a shorter overall stabilization time and enhancement of the tensile properties of textilegrade PAN-based CFs. Our study found that only 70 min of stabilization time with UV irradiation was required to prepare textile-grade PAN-based low-cost CFs with a tensile strength of 2.37 ± 0.22GPa and tensile modulus of 249 ± 5 GPa.
        4,000원
        19.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The ZnO–Na2Ti6O13 composites were synthesized by facile solution combustion method with different molar concentrations of sodium titanate which is prepared by hydrothermal route. The formation of the composites was confirmed by the X-ray diffraction (XRD) analysis. Field emission scanning electron microscope (FESEM) and transmission electron microscope (TEM) results revealed that the synthesized composites exhibit porous morphology, whereas the pristine Na2Ti6O13 nanoparticles have whisker like morphology. Diffuse reflectance spectroscopy (DRS) and photoluminescence (PL) studies were utilized to compute the bandgap and the presence of defects in the composites respectively. The photocatalytic activity of ZnO–Na2Ti6O13 catalyst was investigated through the degradation of 4-nitrophenol under solar light over a period of 180 min and the composite with 0.05 M of Na2Ti6O13 showed higher degradation efficiency (96%) than the other concentrations of Na2Ti6O13 and pristine ZnO. The reduced bandgap, high charge transfer, more oxygen vacancies and the production of high superoxide anion radicals have profound effect on the higher photocatalytic efficiency of the composite with 0.05 of M Na2Ti6O13.
        4,000원
        20.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Individual multi-walled carbon nanotubes (MWCNTs) were exposed to the electron beam of 200 kV energy and high resolution transmission electron micrographs were recorded at several time intervals. Interestingly, the nucleation of diamond nanoparticles with in the highly disordered MWCNT matrix upon electron-irradiation is observed. This happens without any assistance of high pressures and temperatures. High pressure X-ray diffraction experiments were performed on core/shell structures which suggest that even the closed structures of carbon resist any inward pressure, thereby ruling out the possibility of a hypothetical internal pressure under the electron irradiation conditions. Our experiments suggest that the transformation of graphitic carbon into diamond in the size window of a few nanometers is possible due to the stability of the diamond and a selective dissolution effect of 200 kV electrons on graphite. A mechanism for the same is proposed.
        4,300원
        1 2 3 4 5